15W Single Output Industrial DIN Rail ower Supply MODEL:DR-15-24 OUTUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 RILE & NOISE 1: 150 mp-p (Max ) I/: 230AC 1: 72.4 mp-p (Max ) O/:FULL LOAD 2 OUTUT OLTAGE ADJUST RANGE CH1: 21.6~ 26.4 I/: 230 AC I/: 115 AC O/:MIN LOAD 20.81 20.81 ~ ~ 28.39 28.39 / 230 AC / 115 AC 3 OUTUT OLTAGE TOLERANCE 1: 1%~ -1 % (Max) I/: 100 AC / 264 AC O/:FULL/ MIN LOAD 1: 0.08 %~ -0.08 % 4 LINE REGULATION 1: 1 %~ -1 % (Max) I/: 100AC ~ 264 AC O/:FULL LOAD 1: 0.08 %~ -0.08 % 5 LOAD REGULATION 1: 1 %~ -1 % (Max) I/: 230 AC O/:FULL ~MIN LOAD 1: 0.05 %~ -0.05 % 6 SET U TIME 230AC: 115 AC: 1000 1000 (Max) (Max) I/: 230 AC I/: 115 AC O/:FULL LOAD 230AC/ 115AC/ 126 126 7 RISE TIME 230AC: 50 (Max) I/: 230 AC 230AC/ 48 115AC: 50 (Max) I/: 115 AC 115AC/ 46 O/:FULL LOAD 8 HOLD U TIME 230AC: 115AC: 70 16 (TY) (TY) I/: 230 AC I/: 115 AC O/:FULL LOAD 230AC/ 115AC/ 93 19 9 OER/UNDERSHOOT TEST < +5% I/: 230 AC O/:FULL LOAD 10 DYNAMIC LOAD 1: 2400 mp-p I/: 230 AC O/:FULL /Min LOAD 90%DUTY/ 1KHZ TEST: < 5 % 222 mp-p Model: DR-15-24 Test Report 1 / 5
15W Single Output Industrial DIN Rail ower Supply INUT FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 INUT OLTAGE RANGE 85AC~264 AC I/:TESTING O/:FULL LOAD I/: LOW-LINE-3= 82 HIGH-LINE+15%=300 O/:FULL/MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF ) 63~264 TEST: OK 2 INUT FREQUENCY RANGE 47HZ ~63 HZ OSC I/: 100 AC ~ 264 AC O/:FULL~MIN LOAD TEST: OK 3 EFFICIENCY 85 % (TY) I/: 230 AC 86.04% O/:FULL LOAD 4 INUT CURRENT 230/ 0.48 A(TY) I/: 230 AC I = 0.14 A/ 230 AC 115/ 0.88 A (TY) I/: 115 AC I = 0.28 A/ 115 AC O/:FULL LOAD 5 INRUSH CURRENT 230/ 65 A(TY) I/: 230 AC I = 40 A/ 230 AC 115/ 35 A(TY) I/: 115 AC I = 20 A/ 115 AC COLD START O/:FULL LOAD ROTECTION FUNCTION TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 OER LOAD ROTECTION 105 %~ 160 % I/: 230 AC I/: 115 AC O/:TESTING 133%/ 230 AC 133%/ 115 AC Current Limiting 2 OER OLTAGE ROTECTION CH1: 27.6~ 32.4 I/: 230 AC I/: 115 AC O/:MIN LOAD 29.5/ 230 AC 29.5/ 115 AC Shut off o/p voltage,clamping by zener diode 3 SHORT ROTECTION SHORT EERY OUTUT 1 HOUR I/: 264 AC O/:FULL LOAD Hiccup Mode Model: DR-15-24 Test Report 2 / 5
15W Single Output Industrial DIN Rail ower Supply ENIRONMENT TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 TEMERATURE RISE TEST MODEL:DR-15-24 1. ROOM AMBIENT BURN-IN:2 HRS I/: 230AC O/: FULL LOAD Ta= 28.1 2. HIGH AMBIENT BURN-IN: 1 HRS I/: 230AC O/: FULL LOAD Ta= 52.9 NO osition /N ROOM AMBIENT Ta= 28.1 HIGH AMBIENT Ta= 52.9 1 LF1 LF LF510-R1 52.1 73.9 2 BD1 2A/800 GLASS KB208G 53.9 76.2 3 C5 33u/400 105 KMG 48.4 71.9 4 D1 FRD 1A/1K FR107 59.0 82.0 5 T1 MT TF1910 EE-22 69.1 90.5 6 D100 SFRD HER303 3A/200 70.9 92.1 7 C110 100U/35 YXF 54.7 76.7 8 LF101 TR574-R1 47.4 69.6 9 C105 220U/35 60.0 80.8 10 C40 47U/25 YXM 57.0 79.7 11 C36 22U/50 5KH KY 58.3 80.6 12 U1 TO254EN 63.3 90.5 2 OER LOAD BURN-IN TEST 1 HOUR ( MIN ) 3 LOW TEMERATURE TURN ON AFTER 2 HOUR TURN ON TEST I/: 230 AC O/:129 % LOAD I/: 230 AC O/: 100 % LOAD Ta= -25 4 HIGH HUMIDITY HIGH TEMERATURE HIGH OLTAGE TURN ON TEST 5 TEMERATURE COEFFICIENT AFTER 12 HOURS IN CHAMBER ON CONTROL 50 6 IBRATION TEST 1 Carton & 1 Set (1) Waveform: Sine Wave I/: 272 AC O/:FULL LOAD Ta= 50 HUMIDITY= 95 %R.H + 0.03 %(0~50 ) I/: 230 AC O/:FULL LOAD (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) + 0.001 %(0~50 ) Model: DR-15-24 Test Report 3 / 5
15W Single Output Industrial DIN Rail ower Supply SAFETY TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 WITHSTAND OLTAGE I/-O/: 3 KAC/min I/-O/: 3.6 KAC/min I/-O/: 1.087 ma 2 ISOLATION RESISTANCE I/-O/:500DC>100MΩ I/-O/: 500 DC 3 AROAL TU: Certificate NO : R50147188 UL: File NO :E183223 I/-O/: 30 GΩ E.M.C TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 HARMONIC EN61000-3-2 CLASS A 2 CONDUCTION EN55022 CLASS B 3 RADIATION EN55022 CLASS B 4 E.S.D EN61000-4-2 AIR:8K / Contact:4K I/: 230 /240/220AC/50HZ O/:100/75/50/25%LOAD I/: 230 AC (50HZ) O/:FULL/50% LOAD I/: 230 AC (50HZ) O/:FULL LOAD I/: 230 AC/50HZ O/:FULL LOAD ASS ASS Test by certified Lab ASS Test by certified Lab 5 E.F.T EN61000-4-4 INUT: 2K 6 SURGE IEC61000-4-5 L-N :2K L.N-E:4K I/: 230 AC/50HZ O/:FULL LOAD I/: 230 AC/50HZ O/:FULL LOAD 7 Test by certified Lab & Test Report repare M.T.B.F & LIFE CYCLE CALCULATION NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 CAACITOR LIFE CYCLE DR-15-24:SUOSE C105 IS THE MOST CRITICAL COMONENT I/: 230AC O/:FULL LOAD Ta= 25 LIFE TIME= 228355 HRS I/: 230AC O/:FULL LOAD Ta= 50 LIFE TIME= 53242 HRS 2 MTBF MIL-HDBK-217F NOTICES2 ARTS COUNT TOTAL FAILURE RATE: 1172.3K HRS 3 DMTBF/Accelerated Life Test Demonstration Mean Time Between Failure : Above 30,000 hours @ TA 50 Model: DR-15-24 Test Report 4 / 5
15W Single Output Industrial DIN Rail ower Supply COMONENT STRESS TEST NO TEST ITEM SECIFICATION TEST CONDITION RESULT ERDICT 1 ower Transistor ( D to S) or (C to E) eak oltage U1 Rated WM TO254EN 700/2.08A 2 Diode eak oltage D100 Rated HER303 3A/200 3 Clamp Diode eak oltage D1 Rated FRD 1A/1K 4 Control IC oltage Test U1 Rated WM TO254EN: 9 5 Input Capacitor oltage C 5 Rated 33u/400 105 KMG I/:High-Line +3 = 267 O/:(1)Full Load Turn on (2) Full Load (3)Output Short I/:High-Line +3 = 267 O/:(1)Full Load Turn on (2) Full Load (3)Output Short I/:High-Line +3 = 267 O/:(1)Full Load (2) Dynamic Load 90%Duty/1KHz I/:High-Line +3 = 267 O/:(1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change I/:High-Line +3 = 267 O/:(1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 600 (2) 584 (3) 588 (1) 173 (2) 140 (3) 151 (1) 420 (2) 382 (1) (2) (30 5.867 5.881 5.866 (1) 365.3 (2) 371.1 (3) 371 DATE SAMLE TEST RESULT TESTER AROAL 2008/12/26 RD SAMLE ASS SANFORD SU INCENT TSENG 2009/3/17 2009/4/10 RODUCT SAMLE W0901B01 RODUCT SAMLE W0903D01 ASS SANFORD SU INCENT TSENG ASS SANFORD SU INCENT TSENG 2003/12/12 A50-F023 Model: DR-15-24 Test Report 5 / 5