Seapoint Rhodamine Fluorometer

Similar documents
Visible & IR Femtowatt Photoreceivers Models 2151 & 2153

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

COOLED InGaAS DETECTOR HEAD MODEL 71887

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

UV AQUAtracka. In-situ PMT Fluorimeter

Cyclops Integrator User s Manual

Model 7000 Low Noise Differential Preamplifier

Solids Content Sensor OUS 41 / OUS 41-W

INDEX OPERATING PRINCIPLE... 3 Power Supply... 4 Replacing the Batteries... 4 GENERAL PHOTOMETER OPERATION... 4 Operating Modes... 4 SYSTEM MODE...

PSW-002. Fiber Optic Polarization Switch. User Guide

80-MHz Balanced Photoreceivers Model 18X7

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

CLEANING CALIBRATION INTERVAL

PSI MIN MODULATOR BIAS CONTROLLER BOARD

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

AUTOMATION. Operator s Manual. ACF-10 Series Acoustical Flow Sensor for Solids. Rev. 1a, 2/03

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

AMP-13 OPERATOR S MANUAL

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.

Model MV106J/MV116J. ±10nVdc to ±11Vdc Precision DC Voltage Standard Source. Operating Manual

EN SERIES NEMA CASED DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

1.5µm PbSe Power Detector

USER MANUAL FOR VISIBLE SPECTROPHOTOMETER

Balanced Photoreceivers Models 1607-AC & 1617-AC

QL55 Series Luminescence Sensor

Model Hz to 10MHz Precision Phasemeter. Operating Manual

80-MHz Balanced Photoreceivers Model 18X7

Radiant Pro 2500 Video Light (Cat. No. 6047)

TRANSDUCER IN-LINE AMPLIFIER

KPS Turbidity Meter User s Manual

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

High Precision 2.5 V IC Reference AD580*

Amplified High Speed Photodetectors

DIN Thermocouple Conditioner MODEL 5M14(V)

Model 34A. 3Hz to 2MHz 2-Channel Butterworth/Bessel HP, LP, BP, BR Plug-In Filter Card for Model 3905/3916 Chassis.

Photosynthetically Active Radiation (PAR) Smart Sensor (Part # S-LIA-M003)

instructions for Models QC-10 and QC-20 Sound Calibrators MODELS QC-10/QC-20 SOUND CALIBRATORS GENERAL DESCRIPTION

Amplified Photodetectors

INTRODUCTION 提夫自控技术 ( 上海 ) 有限公司 LAS laser sensors cover measurement ranges from 1 to mm. The integrated micro-controller delivers an accur

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

CS105 BAROMETRIC PRESSURE SENSOR

AMP-12 OPERATOR S MANUAL

QL50 Luminescence Sensor

80i-110s AC/DC CURRENT PROBE

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

15-GHz & 25-GHz Photodetectors Models 1480-S & 1481-S

Zoom Stereo Microscope NYMCS-360 Instruction Manual

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

HHMA2 DC / TRUE RMS AC NON-CONTACT MILLIAMMETER

LINEARPYROMETER LP4. Technical Documentation KE November TN

Model BiConiLog Antenna. User Manual

Manual. Operators. DeVORE AVIATION CORPORATION OF AMERICA. Flash Measuring Gun. Patent #5,654,794

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

PCS-150 / PCI-200 High Speed Boxcar Modules

TONE DECODER / PHASE LOCKED LOOP PIN FUNCTION 1 OUTPUT FILTER 2 LOW-PASS FILTER 3 INPUT 4 V + 5 TIMING R 6 TIMING CR 7 GROUND 8 OUTPUT

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

FIBER OPTIC DISPLACEMENT SENSORS. with Analog Output

Waterproof RGB Pixel Control LED Neon Part Number: PLN-RGB-20

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

Models 1421 and 1422 User s Manual. Broadband Amplifiers

225 Lock-in Amplifier

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Holography Transmitter Design Bill Shillue 2000-Oct-03

SPECIAL SPECIFICATION Inch LED Traffic Signal Lamp Unit

655 nm Precision Optical Reflective Sensor Technical Data

OP735. Benchtop Optical Power Meter Instruction Manual

Model 3102D 0-2 kv H.V. Power Supply

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Variable Gain Photoreceiver Fast Optical Power Meter

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

Non-amplified Photodetectors

10-MHz Adjustable Photoreceivers Models 2051 & 2053

ALM473 DUAL MONO \ STEREO AUDIO LEVEL MASTER OPERATION MANUAL IB

TECHNICAL INFORMATION BLUEMAXX Rechargeable Forensic Lights Catalog Nos. BM500, BM500220

TRANSDUCER IN-LINE AMPLIFIER

MFJ SIGNAL ENHANCER II

Non-amplified High Speed Photodetectors

Global Water Instrumentation, Inc.

Model BSI-1A BIPHASIC STIMULUS ISOLATOR

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

CEC VIBRATION TRANSMITTER

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Fits Tiger 320 Series UNIVERSAL FREQ/COUNTER INPUT MODULE

RING CUTTING SYSTEM OPERATION MANUAL

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

LXE300. Four Mounting Holes on Base. Compliant IEC. Warranty

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PUV3402 LED multiwave photometer A new approach to online process photometry

10-Gbit/s 850-nm VCSEL Model 1780

UVA/B Light Meter. Instruction Manual. UVA/B Light Meter Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

User s Guide. RP7000 Series Active Probe. Dec RIGOL Technologies, Inc.

APD110A, APD110A2, APD110C

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MICROSCANNER TM D-Series

How-to guide. Working with a pre-assembled THz system

Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver

OPERATING MANUAL. 100 MHz CENTER FREQUENCY OFF AXIS ACOUSTO-OPTIC BEAM DEFLECTOR MODEL NUMBER: DEG-.51 DOCUMENT NUMBER: 51A12229A

Displacement Follower

NA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation

Transcription:

Seapoint Rhodamine Fluorometer User Manual Standard Version 6/00

Dimensions Open Configuration (no pump) 2.5" (6.4 cm) 6.6" (16.8 cm) 5.1" (13.0 cm) Pumped Configuration Figure 1. 1/2 Scale Drawing. Page 2 6/00

Specifications Power Requirements: 8.5-20 VDC, 15mA avg, 27mA pk Output: 0-5.0 VDC Output Time Constant: 0.1 sec Power-up Transient: 0.6 sec RMS Noise (typ.): 30x gain: 3 mv 10x gain: 1 mv 3x gain: <1 mv 1x gain: <1 mv Excitation Wavelength: 540 nm peak, 20 nm FWHM Emission Wavelength: 610 nm peak, 40 nm FWHM Sensing Volume: 340 mm 3 Sensitivity/Range : 30x gain: 1.0 V/(µg/l) 5 µg/l 10x gain: 0.33 V/(µg/l) 15 µg/l 3x gain: 0.1 V/(µg/l) 50 µg/l 1x gain: 0.033V/(µg/l) 150µg/l Min. Detectable Level: 0.02 µg/l Temperature Coefficient: < 0.3 %/ C Operating Temperature: 0 C to 65 C Depth Capability: 6000 m Length: 16.8 cm Body Diameter: 6.4 cm Sensor Weight (dry): 1000 g Specified sensitivities and ranges are nominal values. Instrument should be calibrated for quantitative measurements. Page 3

Introduction The Seapoint Rhodamine Fluorometer is a high-performance, low power instrument for in situ measurements of Rhodamine WT. Its small size, very low power consumption, high sensitivity, wide dynamic range, 6000 meter depth capability, and open or pump-through sample volume options provide the power and flexibility to measure Rhodamine WT in a wide variety of conditions. The instrument has good ambient light rejection and a low temperature coefficient. The Seapoint Rhodamine Fluorometer can be operated with or without a pump. The small sensing volume of approximately 340 mm 3 can be left open to the surrounding water, or, with the use of the supplied cap, can have water drawn through it using a pump. The total water volume inside the cap is approximately 45 ml. Two control lines allow the user to externally set the sensitivity of the Seapoint Rhodamine Fluorometer by choosing one of four gains. This provides an easy means to set the sensitivity to provide the range and resolution required for a particular application. Sensitivities of 0.033, 0.1, 0.33, and 1 V/(µg/l) are possible. The Seapoint Rhodamine Fluorometer is constructed of rugged, corrosion-free materials, surface mount electronics, and solid-state lamps and detector for excellent durability and high reliability. The Seapoint Rhodamine Fluorometer uses the same Impulse AG-206/306 connector as the Seapoint Turbidity Meter and the Seapoint Chlorophyll Fluorometer, and the these instruments are pin-compatible. Page 4

Optical Design Figure 2 shows the Seapoint Rhodamine Fluorometer optics. Lenses Green Blue LED Excitation Filter/Window Approximate Sensing Volume Photodetector Emission Filter Detector Window Excitation Filter/Window Blue Green LED Figure 2. Seapoint Rhodamine Fluorometer Optics The green LED lamps direct light through the green excitation filter/windows illuminating the sensing volume. Rhodamine WT present in the sensing volume is excited with the green light and fluoresces orange light, a portion of which passes through the detector window. This fluorescent light is then collimated with a lens so that it passes through the emission filter nearly normal to the filter. A second lens then focuses the fluorescent light onto the detector. The end plate of the instrument (or the cap in pumped operation) prevents ambient light from reaching the detector directly. The narrow bandwidth of the emission filter further reduces the amount of ambient light reaching the detector. The sensing volume of the instrument is defined by the intersection of the lamp beams and the detector's cone of reception. This volume is nearly a cylinder of approximately 340 mm 3. Page 5

Electronic Design The Seapoint Rhodamine Fluorometer has an electronic design that achieves high sensitivity while consuming very little power. Surface mount components are used for high reliability and compact design. Low quiescent current components are used, allowing all but about 3 milliamps of the total current drawn by the instrument to drive the lamps. Overall power requirements are 8.5-20 VDC, 15 ma average, 27 ma peak. The instrument is stable with temperature and time. The LED lamps and the detector have low temperature coefficients at their respective operating wavelengths. The overall temperature coefficient of the instrument is less than 0.3%/ C. Degradation of the lamps with operating time will result in about 10% reduction in sensitivity after 5000 hours of operation. Stable output of the instrument occurs at approximately 0.6 seconds after power up. The light source is modulated at 700 Hz and synchronous detection is used to extract the fluorescent signal from the unwanted portion of the signal resulting from ambient light and electronic noise. Achieving high sensitivity using low power was accomplished by paying careful attention to proper circuit board layout to prevent any stray coupling of signals synchronous with the modulation of the light source into the detection circuitry. The offset voltage is proportional to the selected gain. Page 6

Operation Electrical Connections The Seapoint Rhodamine Fluorometer requires 8.5 to 20 VDC input and will draw an average of 15 ma current with a peak current draw of 27 ma. Output is 0 to 5.0 VDC with a 0.1 second time constant. Warning: Applying voltages to the output pin or powering the instrument with a voltage greater than 20 V will result in damage to the instrument. The Impulse AG-306 bulkhead (connector end of sensor) and the mating AG-206 connector (included with pigtail) should be cleaned and lubricated with 3M Silicone Spray, Dow Corning #111 Valve Lubricant or equivalent prior to connecting. The pin numbering on the AG-306 is shown in Figure 3. Note that Pin 1 is larger than the other pins. The AG-206 connector has two raised bumps which align with Pin 1 to make connection with the AG-306 easy. The AG-206 pigtail is supplied with a locking sleeve which screws onto the AG-306 connector after the pigtail is plugged in. 1 2 6 3 5 4 Figure 3. AG-306 Pin numbering. Page 7

Connections for the Impulse AG-206/306 are as follows: Pin 1 white: Power Ground Pin 2 black: Signal Output Pin 3 blue: Signal Ground Pin 4 orange: Power In Pin 5 green: Gain Control A Pin 6 red: Gain Control B The two independent gain control lines A and B are used to select one of four possible gain settings (see Table 1). These wires can be hardwired for the desired gain or interfaced with a microprocessor, using 5 volt logic, to allow gain to be controlled through software. Hardwiring the gain does not require an external voltage source. To hardwire a line to +5V, simply leave it open, which allows an internal pull-up to hold it at +5 VDC. To set a line to 0V, tie it to the power ground. A B Gain Sensitivity Range +5 V +5 V 30X 1 V/(µg/l) 5 µg/l +5 V 0 V 10X 0.33 V/(µg/l) 15 µg/l 0 V +5 V 3X 0.1 V/(µg/l) 50 µg/l 0 V 0 V 1X 0.033 V/(µg/l) 150 µg/l Table 1. Truth Table for Switching Gains The sensitivities and ranges given in Table 1 are nominal values for a typical instrument, and therefore the user should calibrate the instrument as described in the calibration section of this manual before making quantitative measurements. Page 8

Considerations for Choosing Gain Choosing an appropriate gain for a particular application will depend on a number of factors including expected Rhodamine concentrations, resolution of the data recorder's A/D converter, and whether smoothing will be applied to the data. The noise level of the instrument at 30X gain will be above the resolution of the A/D converters in most data loggers. Therefore, for most applications 1X, 3X or 10X gain will be most appropriate. Filtering the Output for Improved Resolution The Seapoint Rhodamine Fluorometer has a low-pass filter with a 0.1 second time constant on its output (1.6 Hz cutoff frequency). In some applications, smoothing the data with a low-pass filter with a time constant greater than 0.1 second will be helpful in reducing the instrument noise thereby allowing lower Rhodamine WT concentrations to be detected. Analog filters can be constructed and placed between the instrument output and the A/D converter to smooth the output. Digital filtering can accomplish this as well, either before storing the data or during analysis of the data. Some data loggers have built-in averaging or smoothing functions which make this especially easy. Figure 4(a) shows several time series of the instrument output at 30x gain. The top series shows the instrument output without any external filtering. The underlying series show the effects of applying low-pass analog filtering to the instrument output. Frequency responses of the filters used are shown in Figure 4(b). Figure 5(a) shows more time series of the instrument output at 30x gain. The top series shows the instrument output sampled Page 9

at 0.11 second intervals. The underlying series were generated by digitally filtering the series with moving averages, as described by: N y n = 1 N k=0 x i k Figure 5(b) shows the frequency responses of the moving mean filters. Page 10

None 10 mv/division RC=0.3 Sec. RC=1.0 Sec. RC=3.0 Sec. 0 100 200 300 400 500 Time (Seconds) (a) 0 RC=0.3 Sec. db -20 RC=1.0 Sec. RC=3.0 Sec. -40 0.01 0.1 1 10 Frequency (Hz) (b) Figure 4. (a) Time series of fluorometer output at 30x gain with and without low-pass analog filtering. (b) Frequency response of single pole RC filter. Page 11

Sample Interval = 0.11 sec None 10 mv/division N=10 N=30 N=100 0 100 200 300 400 500 Time (Seconds) (a) 0 N=100 N=30 N=10 db -20-40 1 0.001 1 0.01 1 0.1 1 1 1000 t 100 t Frequency (b) 10 t 2 t Figure 5. (a) Time series of fluorometer output at 30x gain with and without digital filtering. (b) Frequency response of moving average digital filter. Page 12

Ambient Light Concerns The combined optical filtering and synchronous detection give the Seapoint Rhodamine Fluorometer good ambient light rejection, and ambient light will not be a concern when the instrument is capped and operated with a pump. When operating with an open sample volume, strong fluctuating light may cause a noisy signal. This can happen under fluorescent or incandescent lighting or in surface waters in bright sunlight. Laboratory lighting usually will not increase instrument noise as long as the detector window faces down, away from the lights. If the noisy output persists, shade the instrument or perform tests or calibrations in a vessel with opaque walls. If field measurements are to be made near the water surface with an open sample volume, it is a good idea to experiment with the instrument beforehand, and try to determine if the noise caused by the ambient light will be significant. Again, ambient light rejection will be best with the detector window facing down. If the noise is indeed a concern, consider constructing a baffle to shade the instrument. Measurement Configurations The Seapoint Rhodamine Fluorometer may be configured for open or pumped measurements of Rhodamine WT in water. Please note that the instrument is designed only for measurements in water. Never immerse the instrument in solutions that might damage the instrument body and windows. The Seapoint Rhodamine Fluorometer is supplied in the open sensing volume configuration. In this configuration, as the Page 13

surrounding water flows past the instrument, it will also flow through the instrument's sensing volume The Seapoint Rhodamine Fluorometer also comes with a cap which can be placed over the end of the instrument so that water may be drawn through the instrument with a pump. To install the cap, take off the end plate by removing the two screws that hold it in place. Slip the large O-ring over the lamp towers so that it rests on the reduced diameter of the instrument body. Then slip the cap over the lamp towers so that it presses the O-ring in place. Secure the cap with the two screws which have small O-rings to prevent leaking. The cap has nipples for 3/8" tubing. These nipples can be replaced to accommodate other tubing sizes. When using the instrument in pumped operation in the laboratory, care should be taken to assure that air bubbles are eliminated before making measurements. In this regard, drawing water through the sample volume generally is more effective that pushing it through with the pump. Page 14

Calibration The Seapoint Rhodamine Fluorometer is adjusted at the factory for the nominal range and sensitivity at a given gain setting as specified in this manual. However, for accurate quantitative measurements, user calibrations are required. The Seapoint Rhodamine Fluorometer is stable, with very little change in sensitivity over time. Nonetheless, frequent calibration of the instrument is recommended. Some decrease in sensitivity can be expected after extended use due to decreased output of the lamps (about a 10% decrease in output after 5000 hours of operation) and scratched window surfaces. Page 15

Care The Seapoint Rhodamine Fluorometer is a rugged instrument that should provide years of reliable performance with minimal care. After using, rinse the instrument and clean the windows with water and mild detergent if necessary (avoid using organic solvents). Rhodamine stains can be removed with a weak bleach solution. If the detector window becomes scratched, it may be polished using a cloth buffing wheel with polishing compound, or returned to Seapoint Sensors, Inc. for refinishing or replacing. The connectors should be lubricated before each use with 3M silicone Spray, Dow Corning #111 Valve Lubricant or equivalent. The Seapoint Rhodamine Fluorometer contains no user serviceable electronics and must be returned to the factory if it does not operate properly. Limited Warranty Seapoint Sensors, Inc. warrants this Rhodamine Fluorometer to be free of defects of materials and workmanship under normal use and service for a period of 1 year from the date of shipment. This warranty extends only to the original purchaser. In the event the product fails to operate according to our published specifications during the warranty period, Seapoint Sensors, Inc. will repair or replace the instrument at our discretion. If it is determined that the failure was due to other than normal use or service, repairs will be billed and estimate will be submitted prior to repair work. Shipping costs must be prepaid. Seapoint Sensors, Inc. accepts no responsibility for damage during return shipment. Page 16

87 North Road Kingston, NH 03848-3056 USA Tel: (603) 642-4921 Fax: (603) 642-4922 seapoint@seapoint.com