LI-6200 Condensed Reference

Similar documents
Visa Smart Debit/Credit Certificate Authority Public Keys

LI-250A. Light Meter Instruction Manual. Publication Number March, 2004

LI Superior By Design

CS105 BAROMETRIC PRESSURE SENSOR

C Mono Camera Module with UART Interface. User Manual

MATHCOUNTS. 100 Classroom Lessons. August Prepared by

Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev.

Secret Key Systems (block encoding) Encrypting a small block of text (say 128 bits) General considerations for cipher design:

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION

Function Block DIGITAL PLL. Within +/- 5ppm / 10 years (Internal TCXO Stability) 1 External Reference Frequency Range: 10MHz +/- 100Hz

The Standard for over 40 Years

MX200 Sensor Controller Manual

MODEL 1450A/02-AH Synthesizer

8WD4 Signaling Columns

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 6410A

CSci 127: Introduction to Computer Science

Wireless Data Logger RTR-500 Series Data Loggers Features and Specs

1523, 1524 Thermometer Readout User s Guide

LI-6252 CO 2 Analyzer INSTRUCTION MANUAL

INTRODUCTION Laser Particle Sensor Module PM2007

LI-1500 Light Sensor Logger

LI-6400XT System. Photosynthesis, Fluorescence, Respiration

ETSI TS V ( )

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

H ~ 580 mm Paper used: 0,26 mm gr ("cardstock") 0,15 mm gr Glue: PVA

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION

DEGEN DE1103 FM / MW / SW RECEIVER FM / AM / SSB / CW MODES OPERATING MANUAL

PIECAL 211 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

General regulation functions ElectroStatic Discharge (ESD) ultra high-speed switching High-frequency applications

ALPHASENSE USER MANUAL. Toxic Sensor Evaluation Board Issue 4

General Specifications

Proportional pressure controller

400W, 5V - 188V Surface Mount Transient Voltage Suppressor

Temp / RH / CO 2 Hand-Held Meter

Agilent N7509A Waveform Generation Toolbox Application Program

5520A. Multi-Product Calibrator. Extended Specifications 2005

5520A. Multi-Product Calibrator. Extended Specifications

Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter. Reference Guide

Keysight Noise Sources: 346C and N4002A (All Serial Numbers) Instructions for Setting Bias Current

LI-3000C Portable Area Meter

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater

MT Alliance Temperature Sensor Calibration Procedure

VT1586A Rack Mount Terminal Panel Installation and User s Manual

DATA SHEET. BZX884 series Voltage regulator diodes DISCRETE SEMICONDUCTORS. Product data sheet Supersedes data of 2003 May Mar 26 BOTTOM VIEW

Low Power (na Current Consumption) KHz ME831, ME832, ME833, ME834 Series

High Speed Strain Gauge Amplifier/Isolator User Manual

General Specifications

High Precision 10 V Reference AD587

Document # Logos: Purch-11B Purchasing Use ONLY: How to Change a Vendor in Logos Original Author Karrie Revolinski Date 5/10/13 Updated Author Date

User s Guide EWS-RH. Relative Humidity/Temperature Transmitter. Shop online at. omega.com

INSTRUCTION MANUAL. HMP45C212 Temperature & Relative Humidity Probe. March Copyright 2007 Campbell Scientific (Canada)Corp.

PIECAL 211 Automated RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

This Errata Sheet contains corrections or changes made after the publication of this manual.

5500A. Multi-Product Calibrator. Extended Specifications 2005

SIREC D MP SIREC D200 SIREC D300 SIREC D400 : MP , CA 01. : E86060-D4001-A110-C (CD-ROM) E86060-D4001-A510-C (DVD) SIREC D

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course!

High-precision process calibrator Model CED7000

CIRAS-3. Portable Photosynthesis System. Photosynthesis Chlorophyll Fluorescence Soil Respiration Canopy Assimilation.

Agilent Technologies 355C, D, E, F VHF Attenuators. Operating and Service Manual

Meriam Model M ma Loop Calibrator Operating Instructions

General Specifications

H(T)U(F)3500 SERIES Analog Relative Humidity module with Temperature output

IP-OptoAD16. Opto-Isolated 16-bit A/D Conversion IndustryPack. User s Manual

POINTAX 6000L2 Point Recorder

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

LI Portable Photosynthesis System. Advancements in Gas Exchange and Fluorescence Research

LI-6262 CO 2 /H 2 O Analyzer INSTRUCTION MANUAL

MEMOCAL 2000/2000S. Hand-held calibrator

User s Guide EWS-BP-A. Barometric Pressure Transmitter. Shop online at omega.com

ZG07 CO2 Module. ZG07 series CO2 Module. User Manual

SPM-50 RF Spectrum Power Meter PC Software User Manual

XDC 6000 Watt and Watt Series Digital Programmable DC Power Supply. Operating Manual

SMD /RSGHBHC1-S03/2T

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Audit Attestation Microsec ETSI Assessment 2017 No. AA

Sensor Troubleshooting Application Note

Agilent N6700 Modular Power System Family

AUTOMATION. Operator s Manual. IRU-2xx4/3xx4 Series. Rev. A2, 11/08 Doc

Math 412: Number Theory Lecture 6: congruence system and

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description

Features. Bottom View Equivalent Circuit. Top View Pin Out Configuration. Part Number Case Packaging DMN80H2D0SCTI ITO220AB (Type TH) 50 pieces/tube

User s Guide. PCL1000 Multi-Function Calibrator. Shop online at omega.com. For latest product manuals:

S8 Residential pin header

CS8904 Quad 10Base-T Ethernet Transceiver Technical Reference Manual

MAR2100 MARADIN MEMS DRIVE AND CONTROL

ULPSM-RESPIRR

Features. Applications

GM8036 Laser Sweep Optical Spectrum Analyzer. Programming Guide

Rotel RSX-1056 RS232 HEX Protocol

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course! Shop online at omega.com SM

Fan and Pump AC Inverter

Micro Motion Model 2700 Transmitters with Configurable Input/Outputs 2700***B 2700***C. Configuration and Use Manual Supplement

Precision, Low Power, Micropower Dual Operational Amplifier OP290

Carbon Monoxide (CO) and Carbon Dioxide (CO 2 ) Meter With Air Temp/RH Measurements and Dew Point/Wet Bulb calculations

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter

RHS SERIES RH Set Point Controller/Probe

HTG3500 SERIES Relative Humidity and Temperature Module

Transcription:

LI-6200 Condensed Reference

The LI-6200 Condensed Reference Software Revision 2.00 August, 1990 LI-COR Box 4425 / 4421 Superior St. Lincoln, Nebraska 68504 USA Phone: 402-467-3576 Toll-free: 1-800-447-3576 (U.S. & Canada) FAX: 402-467-2819 e-mail: envsales@env.licor.com www.licor.com

PRINTING HISTORY New editions of this manual will incorporate all material since the previous editions. Update packages may be used between editions which contain replacement and additional pages to be merged into the manual by the user. The manual printing date indicates its current edition. The printing date changes when a new edition is printed. Preliminary Release - August 1986 Revision 1 - March 1987 Revision 2 - September 1987 August 1990 Copyright 1987, LI-COR, Inc. NOTICE The information contained in this document is subject to change without notice. LI-COR MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. LI-COR shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without prior written consent of LI-COR, Inc. 2

TABLE OF CONTENTS Files... 5 Exec Lists... 6 Preoperation... 7 Reminders... 8 User Format Codes... 9 0x Channels... 10 1x Channels... 11 2x Channels... 12 3x Channels... 13 Ax Constants... 14 Bx Constants... 15 Cx Constants... 16 6x Programs... 17 7x Programs... 19 Conversions... 21 Troubleshooting... 22 Notes... 24 3

4

FILES # TYPE FCT: 1 PAGE E7 Data and page parameters 2 SYSTM E3 1x, 2x, 3x, Bx 3 I/O 51 I/O parameters 4 ASCII 56 General purpose 5 PPARM 41 Page parameters 6 OPARM 42 Operating parameters 7 CO2 45 CO 2 calibration list 8 FLOW 46 Flow calibration list 9 RH 47 Cal list 10 SENSR E2 0x, Cx 11 SFORM D8 System format 12 UFORM D9 User format 13 KEYS E1 User key definitions 14 KBUFF ED Key buffer 15 VWSEQ EC Miniview sequence 16 PROG E8 Log key program 5

EXEC LISTS 40 **SETUP** 50 **COMM** 41 set pg parms 51 set I/O parms 42 set opr parm 52 terminal 43 set clock 53 dump pages 44 set QNTM cal 54 binary dump 45 set CO2 cal 55 binary load 46 set FLOW cal 56 ascii capture 47 set RH cal 57 ascii dump 48 zero FLOW 58 binary index 49 CO2 ref 59 4A leaf area 5A 4B aux data 5B 4C 5C 4D 5D 4E 5E 4F 5F D0 ***MEM*** E0 **CONFIG** D1 delete fiels E1 set keys D2 renum files E2 set sensors D3 mem status E3 set sys prog D4 file status E4 reset E2, E3 D5 file index E5 recompute D6 STORE PAD E6 CLEAR PAD D7 edit loop E7 view D8 set sys fmt E8 program D9 set user fmt E9 log DA view labels EA sys reset DB EC set mini view DC DE set kbuff DD ED set kbuff DE EE EXEC KBUFF DF clear mem EF SWAP TERM 6

PREOPERATION 1. Work through the SETUP execute list (SETUP, or FCT 40), which covers the following: Page parameters Operating parameters Set the clock Quantum sensor cal constant CO 2 analyzer cal list Flowmeter cal list RH sensor cal list Set analyzer reference 2. Check each sensor to make sure it is responding as expected: Quantum sensor Air and leaf temp matched? IRGA temp Flowmeter CO 2 concentration Relative humidity 3. Set the ZERO and SPAN for the CO2 analyzer. 4. ZERO the flowmeter (FCT 48). 5. Check the humidity sensor against a standard you can trust. 6. Check system for leaks. 7. Desiccant test (K Test). 7

REMINDERS EVERY 10-15 MINUTES... Shake the desiccant tube EVERY 30-60 MINUTES... Zero the flowmeter Check the CO 2 analyzer zero Test the desiccant (K Test) EVERY DAY... Preoperation procedure Clean chambers LI-6250 fan filter Re-charge used batteries EVERY FEW WEEKS... Check soda lime LI-6250 filter #2 EVERY YEAR... LI-6250 filter #3 LI-6250 internal soda/desiccant OR Return to factory for complete recalibration 8

USER FORMAT CODES HDR PAG DAY MON HOU MIN SEC TIM DAT NOB SYS APR.n AXD.n EOL<.n> SPA<.n> Entire header Page number Day (numeric) Month (numeric) Hour Minute Second Time in HH:MM:SS Date in DD MMM # observations System number nth auxiliary data prompt nth auxiliary data End of line (or n EOLs) Space (or n spaces) Ax Parameters (AA thru AF) 1x.n nth sample of channel 1x 1x.nM nth mean obs of channel 1x 1x.nR nth range of obs of channel 1x 2x.n nth obs of channel 2x 3x.n nth obs of channel 3x OB.n nth observation # LOOP...ENDLOOP Use * for obs. 9

0x CHANNELS 00 LOW reserved 01 LOW TA Chamber temp (mv) 02 LOW TL Leaf temp (mv) 03 LOW RH Relative humidity (mv) 04 LOW TC IRGA temp (mv) 05 HIGH C2 CO 2 signal (mv) 06 LOW QN Qntm (mv) 07 LOW FL Flowmeter signal (mv) 08 OFF Spare channel 1 (mv) 09 OFF Spare channel 2 (mv) 0A OFF Spare channel 3 (mv) 0B OFF Spare channel 4 (mv) 0C OFF Spare channel 5 (mv) 0D OFF Spare channel 6 (mv) 0E LOW BA Battery Voltage (V) 0F LOW reserved Accessed by FCT E2. 10

1x CHANNELS 10 TIME 70 11 QNTM 06 C6 CC 64 65 12 TAIR 01 C3 64 13 TLEAF 02 C4 64 12 62 14 TCO2 04 C3 64 15 CO2 05 CB 64 CA 62 14 71 16 FLOW 07 C8 63 14 72 CF 64 17 RH 03 C7 64 73 18 EAIR 12 74 C2 65 17 64 19 DE/DT 6F 18 1A DC/DT 6F 15 1B - 1F Unused Accessed by FCT E3. 11

2x CHANNELS 20 Unused 21 W 12 75 A1 64 6D 2F 18 A0 65 22 FRACT 16 A5 65 23 FW/S 16 21 64 A1 65 C2 65 24 K A2 A6 22 64 63 19 64 2F 65 6D 25 66 23 64 67 25 E 25 A7 64 23 62 C1 21 63 65 26 GS 13 74 18 25 A0 A4 A3 76 79 27 DC A2 A0 64 1A 64 2F 65 15 25 64 62 28 A 23 15 64 27 C1 21 22 64 63 64 63. 2F (RTS) Accessed by FCT E3. 12

3x CHANNELS 30 PHOTO B0 28 64 31 COND B1 26 64 32 CINT 26 A4 A3 76 7A 25 15 28 7B 33 RS 12 75 A0 65 26 64 6D 34 66 B2 64 34 CS 34 B3 64 35-3F Unused Accessed by FCT E3. 13

Ax CONSTANTS A0 P(mb) A1 A(cm2) A2 Vt(cc) A3 BC(mol) A4 STMRAT A5 Fx(µmol) A6 Vg(cc) A7 Kabs A8 A8 A9 A9 AA AUX DATA 1 AB AUX DATA 2 AC AUX DATA 3 AD AUX DATA 4 AE AUX DATA 5 AF AUX DATA 6 Ax constants are accessed by FCT 41, or by FCT Ax. 14

Bx CONSTANTS B0 1.00 Photo multiplier B1 1.00 Cond multiplier B2 1.00 RS multiplier B3 1.00 CS multiplier B4 0.0 Unused B4 0.0 Unused B5 0.0 Unused B6 0.0 Unused B7 0.0 Unused B8 0.0 Unused B9 0.0 Unused BA 0.0 Unused BB 0.0 Unused BC 0.0 Unused BD 0.0 Unused BE 0.0 Unused BF 0.0 Unused Bx constants are accessed by FCT E3, or by FCT Bx. 15

Cx CONSTANTS C0 0.0 Unused C1 1.0 Unused C2 100.0 Unused C3 0.012207 Thermistor C4 0.00226 Thermocouple C1 C5 0 Unused C6?? Quantum cal C7 0.024414 Humidity C8?? Flow zero C9 0 CO 2 ppm CA 0 CO 2 mv CB 1.00 CO 2 gain factor CC 0.1790 Quantum gain CD 0.0 Unused CE 0.0 Unused CF 44.64 Flow Cx constants are accessed by FCT E2, or by FCT Cx. 16

6x STACK OPERATORS 60 Swap top 2 entries 61 Drop top entry off stack 62 + Add top two entries 63 - Subtract top two entries 64 Multiply top two entries 65 Divide top two entries 66 1/x Invert top entry 67 -x Change Sign of top entry 68 x 2 Square top entry 69 x 3 Cube top entry 6A x Square Root of top 6B Duplicate top entry 6C Fetch previous 1x, 0x value 6D Store top entry to 6E Fetch range obs of 1x 6F Slope channel flag 17

7x STACK OPERATORS 70 Time since pad cleared. Initial Stack: (top) Final Stack: time (s) (top) 71 CO 2 calibration function. I: Signal (mv) Temp (C) F: CO2 (ppm) 72 Flow calibration function. I: Signal (mv) Temp (C) F: Std Flow (cm 3 s -1 ) 73 RH Lookup Table. I: Measured RH (%) F: True RH (%) 74 Saturation Vapor Pressure I: Temp (C) F: Vapor pressure (mb) 75 8.314 (T + 273) I: T F: 8.314 (T + 273) 76 Boundary Layer Correction I: Stmrat BC F: Corrected BC 18

7x STACK OPERATORS cont'd 77 CO 2 Reference I: Ref (ppm) Temp (C) P (mb) F: Ref (ppm) Ref (mv) Gain Factor 78 CO 2 Slope I: Signal (mv) Temp (C) F: Cal Function Slope 79 Stomatal Conductance I: SL ea E P BC SL = Sat vap press of leaf (mb) ea = Vap press of air (mb) E = Transpiration (mol m -2 s -1 ) P = Pressure (mb) BC = Bound. layer cond (mol m -2 s -1 ) F: Cond (mol m -2 s -1 ) 7A Cond. to CO 2 I: g BC g = Stom. cond. (mol m -2 s -1 ) BC = Bound. layer cond (mol m -2 s -1 ) F: Cond CO 2 (mol m -2 s -1 ) 7B Intercellular CO 2 I: g E C A g = Stom. cond. (mol m -2 s -1 ) E = Transpiration (mol m -2 s -1 ) C = Ambient CO 2 (ppm) A = Assim. rate (µmol m -2 s -1 ) F: C i (ppm) 19

7x STACK OPERATORS cont'd 7C 7D 7E 7F Density Factor I: Temp (C) P (mb) F: (TP o )/(T o P) 5th Order Polynomial I: a b c d e f x F: a+bx+cx 2 +dx 3 +ex 4 +fx 5 DeltaT (Energy Balance) I: BC Ta TW E Rn BC = Bound. layer cond (mol m -2 s -1 ) Ta = Chamber air temp (C) TW = Chamber wall temp (C) E = Transpiration (mol m -2 s -1 ) Rn = Net radiation ( W m -2 ) F: (T leaf - T air ) Transpiration (Energy Balance) I: BC Ta Tl T W Rn BC = Bound. layer cond (mol m -2 s -1 ) Ta = Chamber air temp (C) Tl = Leaf temp (C) T W = Chamber wall temp (C) Rn = Net radiation (W m -2 ) F: Transpiration (mol m -2 s -1 ) 20

CONVERSIONS Photosynthesis µmol m -2 s -1 0.044 = mg m -2 s -1 µmol m -2 s -1 1.584 = mg dm -2 hr -1 mg m -2 s -1 36 = mg dm -2 hr -1 Transpiration mol m -2 s -1 18,000 = mg m -2 s -1 mol m -2 s -1 44,100 = W m -2 Conductance mol m -2 s -1 2.5 = cm s -1 Pressure mm Hg 1.333 = millibar kpa 10 = millibar 21

TROUBLESHOOTING Conductance Too Low Humidity reading too low. Flowmeter reading too low. (Re-zero?) Leaf area too high. Volume too low (if not steady state conditions). Bad contact between leaf thermocouple and leaf, with T leaf < T air. Did humidity rise during the measurement? Use a higher flow rate if possible. Conductance Too High or Negative Humidity reading too high. Flowmeter reading too high. (Re-zero?) Desiccant not adequate. Volume too high (if not steady state conditions). Leaf area too low. If it is low enough to make the leaf resistance come out smaller than the boundary layer resistance, then the stomatal resistance (and conductance) will be negative. Bad contact between leaf thermocouple and leaf, with T leaf > T air. Did humidity fall during the measurement? Use a lower flow rate. 22

TROUBLESHOOTING, Cont'd Photosynthesis Too Low (High) CO 2 analyzer calibrated correctly? Are you sure of your span gas? Volume too low (high). Leaf area too high (low). Pressure parameter too low (high). Intercellular CO 2 Too Low (High) Photosynthesis too high (low). Stomatal conductance too low (high). 23

NOTES 24

LI-COR, inc. 4421 Superior St. Lincoln, NE 68504 USA 402-467-3576 FAX: 402-467-2819 1-800-447-3576 (U.S. & Canada) envsales@licor.com www.licor.com