SINEAX V604s Programmable multifunctional transmitter

Similar documents
SINEAX V 604s Programmable multifunctional transmitter

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

SINEAX TV809, 1 channel Programmable Isolating Amplifier

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX G 537 Transducer for Phase Angle Difference

SINEAX I 552 Transducer for AC current

SINEAX U 553 Transducer for AC Voltage

SINEAX G 536 Phase Angle or Power Factor Transducer

KINAX 2W2 Programmable Transmitter for Angular Position

SINEAX B 811 Power Pack with additional Functions

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

KINAX WT 717 Programmable Transmitter for Angular Position

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits

Description of functions Controller system VR660 / A200R

Temperature transmitter itemp PCP DIN rail TMT 121

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

SINEAX VC 603, Programmable combined transmitter/alarm unit

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

KINAX SR 719 Programmable Transmitter for Position Feedback

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Temperature Input Module for Zone 1 Series 9482/32

Plug-in module SIRAX TI 807 Passive DC signal isolator

SINEAX V 604 Programmable universal transmitter

Assembly. Front view. Parametrization interface. Power Bus

itemp HART DIN rail TMT112

Isolators A3/1.

CONTA-ELECTRONICS. Converter Units

EURAX VC 603 Programmable combined transmitter/alarm unit

SINEAX TI 807 Passive DC signal isolator

P5201 Universal Programmable Transmitters with Galvanic Isolation

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

0 2 1 â Ó. itemp HART TMT182. Technical Information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Temperature head transmitter itemp PCP TMT 181

0 2 1 â Ó. itemp HART TMT182. Technical Information

MULTIFUNCTION GRAPHICAL UNIT MGU 800

MODEL: M1EXT. with Display M1E Series

Process displays For standard signals, temperature, resistance measurement

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

Temperature Transmitters - DIN Rail Mounted

itemp PA TMT184 Technical information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Rudder or propeller angular position transmitter KINAX WT720

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

EURAX UI 505, Combined Transducer for AC current and AC voltage

KINAX 3W2 Transmitter for angular position

SINEAX / EURAX 2I1 Passive DC signal isolator

EMBSIN 281 G Power factor transducer

N30P DIGITAL PANEL METER

27/04/2015

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

Digital indicator for panel mounting With multi-function input Model DI25

Electronic alarm signalling unit TES 20. for temperature and standard signals ENA EN

Temperature Transmitters - Head Mounted

USB-2404-UI Specifications

Temperature Transmitter itemp RTD DIN rail TMT 127

Operating instructions. SINEAX VC604s Programmable Safety Value Converter

Theta 20A / 20V. Technical Data Sheet. Special Features

DIGITAL PANEL METER N24 AND N25 METER SERIES

XIOC technology and networking modules

RE92. CHECKMATE. Dual loop controller for industry purpose.

5 years! Modular Housings. VariTrans P Warranty

SHIMADEN DIGITAL INDICATORS

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

B850 Boiler House Energy Monitor

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

POINTAX 6000L2 Point Recorder

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

RMA42. Technical Information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

General Specifications

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Technical Information Barrier RB223

Modicon Momentum automation platform 0

S200 I/O System Units

JUMO Wtrans Receiver with Wireless Data Transmission

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

General Specifications

N24, N25 DIGITAL PANEL METER

Temperature Measuring Amplifier IM34-11Ex-i IM34-12Ex-Ri 1-channel

Transcription:

SINAX V60s for direct currents, direct voltages, temperature sensors, teletransmitters or potentiometers SINAX V60s is a multifunctional transmitter for tophat rail assembly with the following main characteristics: Measurement of C voltage, C current, temperature (RT, TC) and resistance Sensor connection without any external jumpers inputs (e.g. for sensor redundancy or difference formation) outputs (U and / or I) C energy meter function (with S0 output) inputs can be linked with each other and allocated to the outputs which enables calculations and sensor monitoring (e.g. prognostic maintenance of sensors). System capability: Communication via Modbus interface Freely programmable relay, e.g. for limit or alarm signalling igital output (optional) AC/C widerange power supply unit Pluggable highquality screw or spring cage terminals All settings of the instrument can be adapted to the measuring task by PC software. The software also serves visualising, commissioning and service. Table : Input variables, measuring ranges Type of measurement Measuring range Minimum span C voltage [mv] 000 000 mv mv C voltage [V] 600 600 V ) > V C current [ma] 50 50 ma 0. ma Resistance [Ω] 0 5000 Ω Ω RT Pt00 00... 50 C 0 K RT Ni00 60... 50 C 5 K TC Type B 0... 0 C 65 K TC Type 0... 000 C K TC Type J 0... 00 C 9 K Type of measurement Measuring range Minimum span TC Type K 0... C 50 K TC Type L 00... 900 C K TC Type N 0... 00 C K TC Type R 50... 6 C 59 K TC Type S 50... 6 C 65 K TC Type T 0... 00 C 50 K TC Type U 00... 600 C 9 K TC Typ W5ReW6Re 0... 5 C 5 K TC Type WReW5Re 0... 5 C 6 K ) In case of anterior device versions, the measuring range or the overload capacity is only 00...00V. Please check device version on the nameplate or with the PC software CBManager. Camille Bauer Metrawatt ata sheet V60s Le 0.5

SINAX V60s Technical data Measuring input irect voltage Measuring range mv For limits see table Ri > 0 MΩ, continuous overload max. ±00 mv Measuring range V For limits see table (only in corresponding Ri = MΩ, device type) continuous overload max. ±600 V ) irect current Measuring range ma For limits see table Ri = Ω, continuous overload max. ±50 ma Resistance thermometer RT Resistance measurement types Pt00 (IC 605), adjustable Pt0 Pt000 Ni00 (IN 60), adjustable Ni50 Ni000 Measuring range limits See table, or wire connection Measuring current 0. ma Line resistance 0 Ω per line, in wire connection adjustable or calibratable Thermocouples TC Thermocouples Type B,, J, K, N, R, S, T (IC 605) Type L, U (IN 60) Type W5ReW6Re, WRe W5Re (ASTM 990) Measuring range limits See Table Cold junction compensation Internal (with installed Pt00), with Pt00 on terminals or external with reference junction 0 0 C Resistance measurement, teletransmitter, potentiometer Measuring range limits See table, or wire connection Resistance teletransmitter Type WF and WF IN Measuring current 0. ma Line resistance 0 Ω per line, in wire connection adjustable or calibratable Measuring input irect current Measuring range ma Same as measuring input (only in corresponding device type) irect voltage Measuring range mv Same as measuring input Resistance thermometer RT Same as measuring input except: or wire connection Thermocouples TC Same as measuring input Resistance measurement, teletransmitter, potentiometer Same as measuring input except: or wire connection Please note The following device types are available: a) V60s with measuring input for x direct current [ma] and x high direct voltage [V] The direct voltage [V] and direct current [ma] measuring methods can be allocated to Input or Input here. b) V60s with measuring input for x direct current [ma] The different device types are fi rm and cannot be reprogrammed! The measuring inputs and are galvanically connected. If input sensors or input variables are used, observe combination options in Table and circuit instructions contained in the operating instructions! Analog outputs and The two outputs are galvanically connected and have a common earth. Voltage and current output softwareconfi gurable. irect current Output range ± 0 ma, range may be freely set Burden voltage max. V Open circuit voltage < 0 V Limit Adjustable, max. ± ma Residual ripple <% pp related to 0 ma irect voltage Output range ± 0 V, range may be freely set Load max. 0 ma Current limit Approx. 0 ma Limit Adjustable, max. ± V Residual ripple <% pp related to 0 V Output settings Limit Gain/offset trimming Inversion Relay contact output Variant Relay: Contact Switching capacity Variant digital output: Contact Switching capacity pole, normally open contact (NO) AC: A / 50 V C: A / 0 V Transistor, normally open contact (NO) max. VC/mA atenblatt V60s Le 0.5 Camille Bauer Metrawatt

SINAX V60s Bus/programming connection Interface, protocol RS5, Modbus RTU Baudrate 9.6...5. kbaud, adjustable Transmission behaviour Measured quantities for the outputs Input Input Input input Input input Input input Input input Minimum value, maximum value or mean value of input and input Sensor redundancy Input or input Transmission functions Linear, Absolute amount, scaling (gain/ offset), magnifi er function (zoom) userspecifi c via basic value table ( basic values per measured variable) Settling time: Adjustable 0 s Limit values and monitoring Number of limitvalues Measured variable for the limit values Input Input Measured variable for outputs Input input (e.g. drift monitoring in case of sensors) Input input (e.g. drift monitoring in case of sensors) Meter Functions Absolute amount Gradient dx/dt (e.g. temperature gradient monitoring) Time delay Adjustable 0 600 s Signalling Relay contact or digital output, alarm L, status Meter and pulse output Meter : Number Meter source Measured variables for outputs or Settings Mode (pos., neg.), unit (prefi x, s/min/h), meter reset / set Pulse output (variant digital output) Standard: S0 interface according to IC/N 605 Settings Pulse duration (0...50ms), pulse rate Signalling igital output Sensor breakage and short circuit monitoring measuring input Signalling Relay contact or digital output, alarm L, status Output value in case of a fault Signalling to alarm L In case of a sensor error, the defective input ( or ) is signalled by the number of fl ashes of the alarm L (x or x). In case of a failure at both inputs: Alarm L does not fl ash. Other monitoring operations rift monitoring Monitoring of measured value difference between input sensors for a certain period of time (e.g. due to different sensor response times). If the limit value is exceeded for this time, an alarm is signalled. (See limit values and ) Sensor redundancy Measurement with temperature sensors; if sensor fails (fault) sensor is activated for bridging (see measuring quantities for outputs) Alarm signalling Relay contact or digital output Alarm L Time delay Output value in case of a fault Power supply With closed contact, the yellow L shines, invertible alarmfunction Adjustable 0 60 s For sensor breakage and short circuit, value adjustable 0 0% Rated voltage UN Tolerance 0 V C ±5% 00 0 V AC, 50 00 Hz ±5% Power consumption > W or VA isplays at the instrument L Color Function ON green Power on green fl ashing Communication activ RR red Alarm yellow Relais on Configuration, programming Operation with PC software «CBManager» Camille Bauer Metrawatt atenblatt V60s Le 0.5

SINAX V60s Accuracies (according to N/IC 600) Reference conditions Ambient temperature Power supply Reference value Settings Installation position C ± K V C Span Input : irect voltage mv, 0 000 mv Output : 0 ma, burden resistance 00 Ω Mains frequency 50 Hz, Setting time s Input, output, relay, monitoring off or not active, for voltage output: range 0...0 V, burden resistance kω Vertically, detached Basic accuracy At reference conditions ±0.% Other types of measurement and input ranges: RT Pt00, Ni00 ±0.% ±0. K Resistance measurement ±0,% ±0. Ω TC Type K,, J, T, N, L, U ±0.% ±0. K, measurement value > 00 C TC Type R, S ±0.% ±. K TC Type B ±0.% ±. K, measurement value > 00 C TC W5ReW6Re, WReW5Re ±0.% ±.0 K C voltage mv ±0.% ±0.05 mv C voltage V U 00V ±0.% ±0.005 V U > 00V /0.5%0.005V C current ma ±0.% ±0.005 ma Additional error (additive) High range minimum value (Minimum value >0% of maximum value): ±0.% of maximum value Small output range ±0.% * (reference range / new range) Cold junction compensation internal ± K Magnifi er function ± Zoom factor x (basic accuracy additional error) Zoom factor = measured variable range / zoom range Influencing factors Ambient temperature ±0.% per 0 K at reference conditions other settings: basic accuracy and additional errors per 0 K Longterm drift ±0.% Common mode/ series mode infl uence ±0.% Ambient conditions Operating temperature 5 55 C Storage temperature 0 0 C Relative humidity 5%, no condensation Range of utilisation Internal room up to 000m above sea level Installation details esign imensions Assembly Tophat rail housing U Combustibility class V0 according to UL 9 See dimensional drawing For snapon fastening on tophat rail (5 x 5 mm or 5 x.5 mm) according to N 50 0 Terminals Pluggable,.5 mm Front plug spring terminal.5 mm Weight 0. kg Product safety, regulations lectromagnetic compatibility Ingress protection (acc. IC 59 or N 60 59) N 6 0006 / 6 0006 Housing IP 0 terminal IP0 lectric design Acc. IC or N 6 00 egree of pollution Between power supply and all circuits Between the measuring input () and all circuits Between output ( ) and relay contact resp. digital output Between output ( ) and the bus connection Reinforced insulation overvoltage category III operating voltage 00 V test voltage. kv AC rms Reinforced insulation overvoltage category III operating voltage 00 V overvoltage category II operating voltage 600 V test voltage. kv AC rms Reinforced insulation overvoltage category II Working voltage 00 V Test voltage. kv AC rms Functional insulation Working voltage <50 V Test voltage 0.5 kv AC rms nvironmental tests N 6006// N 6006 Shock: 50g, ms, sawtooth, halfsine N 60066 Vibration: 0.5mm/g, 0...50Hz, 0 cycles atenblatt V60s Le 0.5 Camille Bauer Metrawatt

SINAX V60s lectric connections Circuit Terminal Remarks Measuring input Output Output Relay contacts Power supply to (), ( ) 0 (), ( ) 9 (), () 5 (/~) 6 ( /~) See table, : polarity at digital output Note polarity at C Type of measurement Thermocouple with Pt00 at the terminals at the other input Input Input Pt00 Bus/ programming connection,, GN Front plug Resistance thermometer or resistance measurement wire RT, R Variant digital output: = Resistance thermometer or resistance measurement wire RT, R Table : Connection of inputs Please note: If input sensors or input variables are used, observe combination options in Table and circuit instructions contained in the operating instructions! Type of measurement irect voltage mv Input Input U [mv] Resistance thermometer or resistance measurement wire RT, R Ra 0% Rd Resistanceteletransmitter WF 00% Re Thermocouple with external cold junction thermostat or internally compensated Resistanceteletransmitter WFIN Ra Rd Re 0% 00% Thermocouple with Pt00 at the terminals at the same input Pt00 irect voltage V (only in corresponding device type) U [V] 6 Camille Bauer Metrawatt atenblatt V60s Le 0.5 5

SINAX V60s Type of measurement irect current ma (Input only in corresponding device type) Input Input 5 6 I [ma] imensional drawing Screw terminals Table : Measuring method combination options Input measuring method U [mv] earthed U [V] I [ma] TC ext. earthed TC int. earthed R L R L RT L RT L I [ma] Input Terminals, 6, 5,,,,,,,,,,, 6, measuring method U [mv], earthed U [V] 6, I [ma] 5, TC ext., earthed TC int., earthed,, R L, R L,, R L,,, RT L, RT L,, WF,, WF_IN,, RT L,,, Selectable only in device type x direct current [ma] and x high voltage [V] Selectable only in device type x direct current [ma].5 0 Spring cage terminals 0.5 0 Scope of supply SINAX V60s Safety Instructions 6 50 Software and ocuc 56 0 Accessories USBRS5 converter (for programming the V60s) Article No. 6 9 6 atenblatt V60s Le 0.5 Camille Bauer Metrawatt

SINAX V60s Ordering details Standard versions The following transmitter types programmed in basic confi guration are available as standard versions. An indication of the article number is suffi cient: Version Configuration Ordercode Article No. evice versions for high C voltages: C voltages of up to 600VC can be measured at one input. In addition, mv, RT, TC and resistance measurements are possible at both inputs. At one input ma. The device is supplied with screw terminals and a limit value relay. The following confi guration is preset: Input : 0 000 mv / Input : not used Output : 0 ma / Output : not used 60s0 AA0 000 6 9 evice version without a high C input: Contrary to the version for high voltages, ma signals can be processed simultaneously at both inputs of this device version. In addition, mv, RT, TC and resistance measurements are possible. The device is supplied with screw terminals and a limit value relay. The following confi guration is preset: Input : 0 ma / Input : 0 ma Output : 0 ma / Output : 0 ma 60S 0AC0 C0 696 Please note: This are two hardware platforms. A SINAX V60s with high C Voltage cannot be confi gured to x ma inputs afterwards, just as a SINAX V60s with x ma cannot measure a high C Voltage. V60s, Programmable 60s. Mechanical design Tophat rail housing. Version Standard with screw terminals Standard with spring cage terminals. Climatic rating Standard climatic rating. Test certificate without test certifi cate 0 with test certifi cate German with test certifi cate nglish 5. Configuration Basic configuration: G Hardware layout for measuring ma at both inputs. Voltage > VC up to 00 VC is not possible. Confi gured: Input : 0 ma / Input : 0 ma Output : 0 ma / Output : 0 ma Programmed to order A V60s, Programmable 60s 6. Mains ripple suppression 50Hz 60Hz. Input mv Input (range 000 000 mv) A [mv]: V Input (range 600 600 V) B [V]: ma Input (range 50 50 ma) C [ma]: Thermocouple (internal compensation) Resistance thermometer wire Resistance thermometer wire F Resistance thermometer wire G Resistance sensor wire H Resistance sensor wire J Resistance sensor wire K mv Input: minimum span mv V Input: minimum span > V ma Input: minimum span 0, ma Camille Bauer Metrawatt atenblatt V60s Le 0.5

SINAX V60s V60s, Programmable 60s. Sensor Type Input Not used 0 Type B (Range 0 0 C) A Type (Range 0 000 C) B Type J (Range 0 00 C) C Type K (Range 0 C) Type L (Range 00 900 C) Type N (Range 0 00 C) F Type R (Range 50 6 C) G Type S (Range 50 6 C) H Type T (Range 0 00 C) J Type U (Range 00 600 C) K Type W5ReW6Re (Range 0 5 C) L Type WReW5Re (Range 0 5 C) M RT Pt 00 (Range 00 50 C) N RT Pt 000 (Range 00 50 C) O RT Ni 00 (Range 60 50 C) P RT Ni 000 (Range 60 50 C) Q Resistor (Range 0 5000 Ω) R [W]: Type B: minimum Span 65 K Type : minimum Span K Type J: minimum Span 9 K Type K: minimum Span 50 K Type L: minimum Span K Type N: minimum Span K Type R: minimum Span 59 K Type S: minimum Span 65 K Type T: minimum Span 50 K Type U: minimum Span 9 K Type W5ReW6Re: minimum Span 5 K Type WReW5Re: minimum Span 6 K RT Pt 00: minimum Span 0 K RT Pt 000: minimum Span 0 K V60s, Programmable 60s RT Ni 00: minimum Span 5 K RT Ni 000: minimum Span 5 K Resistor: minimum Span 9. Input Not used 0 mv Input (Range 000 000 mv) A [mv]: ma Input (Range 50 50 ma) C [ma]: Thermocouple (internal compensation) Resistance thermometer wire Resistance thermometer wire F Resistance sensor wire H Resistance sensor wire J mv Input: minimum Span mv ma Input: minimum Span 0, ma 0. Sensor Type Input Not used 0 Type B (Range 0 0 C) A Type (Range 0 000 C) B Type J (Range 0 00 C) C Type K (Range 0 C) Type L (Range 00 900 C) Type N (Range 0 00 C) F Type R (Range 50 6 C) G Type S (Range 50 6 C) H Type T (Range 0 00 C) J Type U (Range 00 600 C) K Type W5ReW6Re (Range 0 5 C) L Type WReW5Re (Range 0 5 C) M RT Pt 00 (Range 00 50 C) N RT Pt 000 (Range 00 50 C) O RT Ni 00 (Range 60 50 C) P RT Ni 000 (Range 60 50 C) Q atenblatt V60s Le 0.5 Camille Bauer Metrawatt

SINAX V60s V60s, Programmable 60s Resistor (Range 0 5000 Ω) R [W]: minimum Span ditto Sensor Type Input. Output signal / Measuring output current (Range 0 0 ma) [ma]: voltage (Range 0 0 V) [V]:. Output signal / Measuring output Not used 0 current (Range 0 0 ma) [ma]: voltage (Range 0 0 V) [V]:. Relay contact output Relay, normally open contact (NO), AC: A/50V, C: A/0V igital output for fast pulse (S0) Umax / Imax: VC / ma Basic configurations Type Standard, with measuring for x direct current [ma] Basic configuration Input and : 0mA Output and : 0mA Rely on us. Camille Bauer Metrawatt AG Aargauerstrasse CH560 Wohlen / Switzerland Phone: 56 6 Fax: 56 6 info@cbmag.com www.camillebauer.com Subject to changes Issue 0.5 ata sheet V60s Le