Materials Science Devices Life Science Advanced Applications

Similar documents
INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

Cutting-edge Atomic Force Microscopy techniques for large and multiple samples

Asylum Research. MFP-3D Infinity. Endless Applications. Unlimited Potential. Performance / Versatility / Support

NanoFocus Inc. Next Generation Scanning Probe Technology. Tel : Fax:

Nanosurf easyscan 2 FlexAFM

Park NX20 The leading nano metrology tool for failure analysis and large sample research.

Indian Institute of Technology Bombay

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

10 Things to Consider when Acquiring a Nanopositioning System

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+)

SPM The Industry s Performance Leader High Resolution Closed-loop System Fast, Easy Tip & Sample Exchange Versatility and Value Powerful Research

The NanomechPro Toolkit: Accurate Tools for Measuring Nanoscale Mechanical Properties for Diverse Materials

The Most Accurate Atomic Force Microscope. Park NX20 The leading nano metrology tool for failure analysis and large sample research.

Optical Microscope. Active anti-vibration table. Mechanical Head. Computer and Software. Acoustic/Electrical Shield Enclosure

MFP-3D-BIO. Asylum Research. The only full-capability AFM on an inverted optical microscope

Electronic Characterization of Materials Using Conductive AFM

Advanced Nanoscale Metrology with AFM

University of MN, Minnesota Nano Center Standard Operating Procedure

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

SENSOR+TEST Conference SENSOR 2009 Proceedings II

Atomic Force Microscopy (Bruker MultiMode Nanoscope IIIA)

Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry

Lecture 20: Optical Tools for MEMS Imaging

Nanoscale Material Characterization with Differential Interferometric Atomic Force Microscopy

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

LOW TEMPERATURE STM/AFM

R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS

Lateral Force: F L = k L * x

nanovea.com PROFILOMETERS 3D Non Contact Metrology

Park XE7 The most affordable research grade AFM with flexible sample handling.

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

Options and Accessories for Asylum Research MFP-3D AFMs

; A=4π(2m) 1/2 /h. exp (Fowler Nordheim Eq.) 2 const

Coherent Laser Measurement and Control Beam Diagnostics

PICO MASTER 200. UV direct laser writer for maskless lithography

Park NX10. The most accurate and easiest to use Atomic Force Microscope.

taccor Optional features Overview Turn-key GHz femtosecond laser

OPTICS IN MOTION. Introduction: Competing Technologies: 1 of 6 3/18/2012 6:27 PM.

Supplementary Figure 1

Manufacturing Metrology Team

Synergy ESPM 3-D Environmental Scanning Probe Microscope Operation Manual

Microscopic Structures

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

Investigate in magnetic micro and nano structures by Magnetic Force Microscopy (MFM)

NOVA S12. Compact and versatile high performance camera system. 1-Megapixel CMOS Image Sensor: 1024 x 1024 pixels at 12,800fps

Imaging Carbon Nanotubes Magdalena Preciado López, David Zahora, Monica Plisch

The Most Accurate Atomic Force Microscope. Park XE15 Power and versatility, brilliantly combined.

Nanosurf Nanite. Automated AFM for Industry & Research.

AFM of High-Profile Surfaces

Introduction of New Products

Park NX-Hivac The world s most accurate and easy to use high vacuum AFM for failure analysis.

Figure for the aim4np Report

7 CHAPTER 7: REFRACTIVE INDEX MEASUREMENTS WITH COMMON PATH PHASE SENSITIVE FDOCT SETUP

Atomic Force Microscopes

ATOMIC FORCE MICROSCOPY

Keysight 9500 AFM. Data Sheet

1.6 Beam Wander vs. Image Jitter

Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera

Large Signal Displacement Measurement with an Asylum SA Atomic Force Microscope Rev B

Standard Operating Procedure

ASM Webinar Digital Microscopy for Materials Science

Rebirth of Force Spectroscopy: Advanced Nanomechanical, Electrical, Optical, Thermal and Piezoresponse Studies

Ionscope SICM. About Ionscope. Scanning Ion Conductance Microscopy. Ionscope A brand of Openiolabs Limited

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Information & Instructions

Instructions for easyscan Atomic Force Microscope

Fully depleted, thick, monolithic CMOS pixels with high quantum efficiency

PicoMaster 100. Unprecedented finesse in creating 3D micro structures. UV direct laser writer for maskless lithography

Constant Frequency / Lock-In (AM-AFM) Constant Excitation (FM-AFM) Constant Amplitude (FM-AFM)

Atomic Scale Patterning Made Easy

Dual-channel Lock-in Amplifier Module

Technical Explanation for Displacement Sensors and Measurement Sensors

Radial Polarization Converter With LC Driver USER MANUAL

Basic methods in imaging of micro and nano structures with atomic force microscopy (AFM)

Zeta-300 3D OPTICAL PROFILER

Suivie de résonance: méthodes à fréquences multiples. Romain Stomp Application Scientist, Zurich Instruments AG. ZI Applications

Microscopy. The dichroic mirror is an important component of the fluorescent scope: it reflects blue light while transmitting green light.

Imaging and Spectroscopy Applications Guide

Cavity QED with quantum dots in semiconductor microcavities

Frequency Response Analyzers for Stability Analysis and Power Electronics Performance Testing

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

attocube systems Probe Stations for Extreme Environments CRYOGENIC PROBE STATION fundamentals principles of cryogenic probe stations

Things to check before start-up.

Supporting Information 1. Experimental

ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation

Micro-manipulated Cryogenic & Vacuum Probe Systems

ScanArray Overview. Principle of Operation. Instrument Components

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

Study of shear force as a distance regulation mechanism for scanning near-field optical microscopy

Akiyama-Probe (A-Probe) guide

Figure 4.1 Vector representation of magnetic field.

MS260i 1/4 M IMAGING SPECTROGRAPHS

Electro-optic Spectral Decoding Measurements at FLASH

Large Signal Displacement Measurement with an MTI Photonic Sensor Rev B

FlexDDS-NG DUAL. Dual-Channel 400 MHz Agile Waveform Generator

Comparison of resolution specifications for micro- and nanometer measurement techniques

Akiyama-Probe (A-Probe) guide

Nanosurf easyscan 2 Your Modular Scanning Probe Microscopy System

Angular Drift of CrystalTech (1064nm, 80MHz) AOMs due to Thermal Transients. Alex Piggott

Transcription:

TM

Head XY Scanner Base Technical Innovations TM Sensored, closed loop positioning for high resolution imaging, accuracy, and reproducibility. Pioneering all-digital controller for open software adaptability, power and flexibility. Built-in advanced features such as real-time 3D rendering, nanolithography/nanomanipulation, and Dual AC Mode for dual resonance and harmonic imaging. Designed for flexibility and expandability, with a wide range of available system, environmental and application options to enhance capabilities, including nanoindentation and Piezoresponse Force Microscopy (PFM). Please refer to the MFP-3D Options data sheet for details. Materials Science Devices Life Science Advanced Applications Aggregate of colloidosomes formed from the flash-curing of methacrylate emulsion droplets that are stabilized with 400nm PMMA latex spheres, 50μm scan. Iomega Zip 1GB drive write head. The MFM phase signal was overlaid on top of the topography, 20μm scan. Shewanella oneidensis strain MR-1 bacteria showing conductive bacterial nanowires, 5µm scan. Sample courtesy M. El-Naggar, USC and Y. Gorby, J. Craig Venter Institute. Nanoindentation on silicon, 1µm scan.

Designed by Scientists Who Understand the Demands of Your Research. Roger Proksch Jason Cleveland Co-founders Asylum Research was founded by scientists with the simple goal of creating the world s best research instrumentation for other scientists. We offer the most technically advanced Atomic Force Microscopes for applications such as materials science, life science, polymers, nanolithography, electrical/ magnetic measurements, and nanoindenting. Asylum Research sets the bar for AFM performance. Personalized, Exceptional Support Once you begin your research, our staff scientists are here to help you get the most out of your MFP-3D AFM. We extend this personalized support by being virtually in your lab with OnSight a remote support system that lets us view, diagnose and control your system over the Internet. Our easy, secure, web-based system enables shared screen, mouse and keyboard control of your AFM, making it ideal for training and troubleshooting. Asylum AFMs Have the Lowest Cost of Ownership A full one-year warranty is included with the MFP-3D-SA. Because of our robust, reliable systems, you can be sure that the cost of ownership will remain low even beyond the warranty period.

MFP-3D Head Low noise, eliminates interference Sensored optical lever with diffraction limited optics and a low coherence light source virtually eliminates interference artifacts. The NPS TM sensored Z axis provides precise measurements of the cantilever position for accurate force and topography measurements. Piezo Position Sensitive Detector Light Path Cantilever Z Flexure Stage Flexure Hinge Piezo Nanopositioning System (NPS) Sensor Optical Path L c =87nm 117 146 175 203 232 262 292 50 pn To Cameras Cold Mirror MFP-3D XY Scanner Precision and accuracy unlike any tube scanner The MFP-3D uses a flexured scanner and patented NPS sensors which measure the exact position of each axis (X-Y). They correct for hysteresis and creep, providing flat scans and the ability to accurately zoom and offset with one mouse click. Recollimation Lens Sample 0 50 100 150 200 Extension (nm) Mechanical Unfolding of Protein XY Flexure Hinge NPS Allows Precise Zooms NPS Sensor Piezo

To Cameras Bottom View Objective MFP-3D Base Three configurations for illuminating and viewing your sample Top view for opaque samples Bottom view for transparent samples Dual view for both viewing options Fiber Port for Köhler Illumination All-Digital Controller and Software Flexibility All-digital configuration allows virtually the entire system operation to be controlled through the MFP software interface (IGOR Pro) for easy addition of new microscope capabilities. What Kind of User Are You? New Experienced Power Built-in Features ModeMaster TM - A library of standard and user-defined operation modes such as AC, Contact, Phase, EFM, LFM, PFM, Force Mode, Nanolithography SmartStart TM - Auto configures any peripheral that interfaces with the controller for plug and play operation 25+ megapixel resolution MicroAngelo TM - Nanolithography and manipulation ARgyle TM - Real3D rendering both on and offline Channel Overlay Overlay data such as EFM or phase channel on topography IGOR Command and macro language at your disposal Edit and create your own automated MacroBuilder routines Software control of signal routing through crosspoint switch All-Digital ARC2 Controller 100% digital for low noise, fast operation, and flexibility Field Programmable Gate Array (FPGA) and Digital Signal Processor (DSP) Fast analog-to-digital/digital-to-analog conversions ARgyle Channel Overlay, Second Mode (Dual AC) Amplitude Image of ZnO, 1µm Scan.

Specifications Operating Modes Contact Mode: Imaging using feedback on deflection. Height, deflection, and lateral force signals available. AC and Dual AC : Q-controlled imaging using feedback on amplitude. Signals include height, amplitude/phase, I/Q, deflection; both air and fluid. Force Mode: Force curve acquisition in contact or AC mode. All signals available. Lateral Force: Frictional force imaging. MicroAngelo: Built-in nanolithography/ nanomanipulation. EFM, Surface Potential, Conductive AFM (CAFM) with ORCA (optional); Magnetic Force Microscopy (MFM), Variable Field MFM (optional); Piezoresponse Force Microscopy, Vector PFM, Switching Spectroscopy PFM (high voltage optional); Scanning Kelvin Probe Microscopy (SKPM); Nanoindentation (optional); Dual AC Resonance Tracking (DART); Thermal Analysis (optional) Data Acquisition Data size is limited only by the memory on the PC (i.e., 10 million point force curves and >5k x 5k point images are possible). It is possible to capture data at 5MHz for up to two million points continuously. Scan Axes X&Y: 90µm travel in closed loop. Closed loop position control with sensor noise <0.5nm average deviation (Adev) in a 0.1Hz-1kHz bandwidth (BW) and sensor nonlinearity <0.5% (max deviation/full travel) at full scan. Z: >15µm sensored travel. Sensor noise <0.25nm Adev in a 0.1Hz-1kHz BW and sensor non-linearity less than 0.05% (max deviation/full travel) at full scan. Z height: noise <0.06nm Adev, 0.1Hz-1kHz BW. Optical Lever Noise <0.02nm Adev in a 0.1Hz to 1kHz BW. Controller Electronics ADCs: One 16-bit input operating at 5MHz with seven gains and a 16-bit offset. Used primarily for cantilever deflection, but also user accessible; Five 16-bit inputs operating at 100kHz. Typically three are used for the reading of the X, Y, and Z sensors and two are available for user inputs. Frequency Synthesizer: Outputs from two Direct Digital Synthesizers (DDS) are summed and available on a 16-bit, 10MHz DAC. Frequency: DC to 2.0MHz in 2mHz increments. Amplitude: 0 to 20V(p-p) in 0.6mV increments. Amplitude, phase, and frequency of the oscillator can be controlled from software at 100kHz update rates. DACs: Six high resolution, ultra low-noise, fast 24- bit channels updated at 100kHz: two for XY scanning (14kHz bandwidth); one for Z feedback (117kHz bandwidth); and three general purpose (56kHz bandwidth). Digital Lock-ins: The 5MHz ADC is the input to two fully digital lock-ins that provide quadrature ouputs. Both R/ϑ (amplitude/phase) and I/Q (Rcosϑ/ Rsinϑ) are available in output bandwidths up to 9kHz. DSP: Floating point processor running at 80MHz. Digital Q-control: for cantilevers from 2kHz to 2MHz; typically enhances or suppresses Q by 5X. Computer-to-Controller Communication: Universal Serial Bus (USB). X, Y, & Z High Voltage Outputs: -10 to +150V. Computer: High-performance dual-monitor Windows computer (inquire for latest specifications and custom configurations). Light Source Superluminescent diode (SLD) is classified as Class 1M. Viewing with an optical instrument within a distance of 100mm may pose an eye hazard. Stage Micrometer driven stage for mechanical alignment of the cantilever tip and sample. MFP Head Standard Head: Flexure-mounted optical lever system with low-coherence SLD, liquid-compatible and AC-capable cantilever holder, dichroic mirror and window for optical access to cantilever, 80-pitch engage screws, and Invar shell. Extended Head (optional): 40µm Z scan range. Top View Head (optional): Adds 10x, 0.28 NA long-working distance objective with focus and beam steering adjustments, allows high resolution optical imaging of tip and sample. Narrowband Source (optional): Eliminates interference with sensitive optical experiments. High Bandwidth Photodiode (optional): Increases photodiode bandwidth for deflection and lateral signals to 7MHz. Base Models Stand Alone (SA): Three models are available. All feature bright field microscopy with Köhler illumination, adjustable aperture and field diaphragm, remote 150W light source coupled via fiber bundle, dual 1/4" CCD s with 720µm and 240µm fields of view; integrated scanning and interconnect board, and rigid low-vibration construction. Top View: Uses infinity-corrected Mitutoyo objective in Top View head for imaging of opaque samples at 3µm resolution. Bottom View: For transparent samples only. Default configuration is 10x/0.25 NA infinitycorrected objective. Others available upon request. Dual View: Combines features of Top and Bottom View, with switchable shutters. Allows for transmitted light in either direction. Sample Holders For samples up to 3.4"x1.5", including glass slides and coverslips. Specialized sample holders including flow-through and heating available (see Options Data Sheet). Software Open user interface based on IGOR Pro incorporates professional-quality analysis and graphing capabilities. AFM analysis includes section, histogram, roughness, particle analysis, and masking. Features include but not limited to: Nonlinear curve fitting to arbitrary user-defined functions. Extensive image analysis including 2D FFT s, wavelet transformations, convolutions, line profiles, particle analysis, edge detection (eight methods, including Sobel), and thresholding (five methods, including fuzzy entropy). Automatic spectral fitting and calibration of cantilever spring constants using thermal noise and Sader method. Easy generation of scientific publication quality graphs and page layouts. MFP-3D-SA is a Class 1M Laser Product ARgyle: OpenGL 3D rendering technology for advanced image display. Generate, display, and visualize 3D images in real-time while you scan as well as off-line processing. Overlay alternate channel data with primary to view feature correlation. Independent scaling of axes for true 1:1 aspect ratio. Mouse-driven rotating, panning, scaling, and specular lighting control of images. Export 3D images to clipboard, JPEG, TIFF, BMP, PNG, STL, VRML 2.0. Stereo anaglyph creation from 3D images. Vibration Isolation Vibration isolation is recommended for all systems. See Options Data Sheet. Additional Options A wide range of system, environmental, and application options are available to enhance the capabilities of the MFP-3D-SA. See MFP-3D Options Data Sheets for additional information. 1 4 7 Cover Images 1. Nanoindenting of indium tin oxide, 800nm scan. 2. Block copolymer self-organized into a close-packed lattice of spherical microdomains. Lattice orientation (color) overlaid on height data (light/dark) illustrates grain boundaries and defects, 16µm scan. Sample courtesy of M. Trawick, Univ. of Richmond. 3. Type I collagen imaged using Dual AC mode. Fundamental resonance phase data overlaid on AFM topography, 4µm scan. 4. Strain-induced corkscrew pattern on MBE grown AlGaAs, 12µm scan. Sample courtesy of T. Daniels-Race, LSU. 5. EFM photoinduced charging rate map generated by plotting the inverse exponential time constant for photoinduced charging at each point from the AFM image (not pictured). Dark rings indicate regions of slower charging. Image courtesy of D. Coffey and D. Ginger, Univ. of Washington. 6. Sapphire crystal following annealing at 1400 C leaving a clean surface with atomic steps (~3Å tall ) and occasional defects, 12µm scan. Image courtesy of S. MacLaren, UIUC. 7. Lead titanate film with PFM phase data overlaid on AFM topography, 5µm scan. Image courtesy of A. Gruverman and D. Wu, UNL. Sample courtesy H. Funakubo. 8. SEBS spuncoat onto a silicon wafer. Phase data overlaid on AFM topography, 2µm scan. Sample courtesy of R. Segalman and A. Hexemer, Kramer Group, UCSB. 9. Quantum dot structure created on a GaAs wafer using oxidation lithography, 2.5µm scan. Courtesy of D. Graf and R. Shleser, Ensslin Group, ETH Zurich. ARC2, ARgyle, Dual AC, MFP-3D, MicroAngelo, ModeMaster, MacroBuilder, NPS, ORCA, Real3D, and SmartStart are trademarks of Asylum Research. Other trademarks are those of their respective owners. Represented by: 2 5 8 3 6 9 6310 Hollister Avenue Santa Barbara, CA 93117 voice: 805-696-6466 fax: 805-696-6444 Toll free: 888-472-2795 www.asylumresearch.com sales@asylumresearch.com Specifications subject to change without notice Atomic Force Microscopes 5-2012