Tailored Insulations for High Transmission Rate Data Cable

Similar documents
Chapter 12: Transmission Lines. EET-223: RF Communication Circuits Walter Lara

COAX 101. Author: Rob Wessels. Vice President of Engineering

ECE 528 Understanding Power Quality

Field Instrument Cable. Electrical Noise

S-Link. RF Cable Solution

ACR (Attenuation to Crosstalk Ratio) ACR-F. Alien Crosstalk. Attenuation (signal attenuation, conductor attenuation)

DATA TRANSMISSION. ermtiong. ermtiong

Class 4 ((Communication and Computer Networks))

NETWORK CONNECTIVITY SYSTEMS

TERM PAPER OF ELECTROMAGNETIC

Media. Twisted pair db/km at 1MHz 2 km. Coaxial cable 7 db/km at 10 MHz 1 9 km. Optical fibre 0.2 db/km 100 km

Figure 4-1. Figure 4-2 Classes of Transmission Media

A Few (Technical) Things You Need To Know About Using Ethernet Cable for Portable Audio

COPPER + LWL RAW CABLES

Cable Testing TELECOMMUNICATIONS AND NETWORKING

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

Objectives of transmission lines

n Proper pin termination at each end n Continuity to the remote end n Shorts between any two or more conductors n Transposed pairs: n Crossed pairs.

HIGH PRESSURE MOULDING TECHNOLOGY

Point-to-Point Communications

OMNETICS CONNECTOR CORPORATION PART I - INTRODUCTION

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

Recent Innovations in 48 AWG Micro-Coaxial Design & Manufacturing

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Influence of Aging Effects on Cables. Influence of Aging Effects on RF behavior Including Mode Conversion of STP and UTP Cables

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

Application Bulletin 240

Transmission Media. Transmission Media 12/14/2016

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

William Stallings Data and Computer Communications 7 th Edition. Chapter 4 Transmission Media

EMI Filters Demystified. By William R. Bill Limburg February 21, 2018 Phoenix Chapter, IEEE EMC Society

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Physical Test Setup for Impulse Noise Testing

G019.A (4/99) UNDERSTANDING COMMON MODE NOISE

Copper and Fiber Optic Cables

Revisions to ASTM D7310 Standard Guide for Defect Detection and Rating of Plastic Films Using Optical Sensors

Power Quality. Case Study. Conrad Bottu Laborelec January 2008

A6.6 9 th International Conference on Insulated Power Cables A6.6

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

TONGFENG FLEXIBLE CONDUIT TONGFENG FLEXIBLE CONDUIT

CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH

Transmission Media. - Bounded/Guided Media - Uubounded/Unguided Media. Bounded Media

Understanding and Inspecting THE DIGITAL BUS. by Jim Sparks

Approach for Probe Card PCB

Crosstalk Coupling between Cable Pairs

EXCELLENT ELECTRICAL PERFORMANCES

Channel Characteristics and Impairments

Product Bulletin. Belden DataTwist 4800 Cables

Computer Networks Lecture -4- Transmission Media. Dr. Methaq Talib

William Stallings Data and Computer Communications. Bab 4 Media Transmisi

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Contents. Telecom Service Chae Y. Lee. Data Signal Transmission Transmission Impairments Channel Capacity

Scotchlok UR2 Connector

Books: 1. Data communications by William L Schweber 2. Data communication and Networking by Behrouz A F0rouzan

DIELECTRIC HEATING IN INSULATING MATERIALS AT HIGH DC AND AC VOLTAGES SUPERIMPOSED BY HIGH FREQUENCY HIGH VOLTAGES

Contents. ITS323: Introduction to Data Communications CSS331: Fundamentals of Data Communications. Transmission Media and Spectrum.

ITS323: Introduction to Data Communications CSS331: Fundamentals of Data Communications

Optimization of Layer Thickness to Yield Predetermined Shielding Performance of Multilayer Conductor Electromagnetic Shield

Maximum date rate=2hlog 2 V bits/sec. Maximum number of bits/sec=hlog 2 (1+S/N)

GLOSSARY. Aramid Yarn Generic name for a tough synthetic material that is often used in cable construction to provide tensile strength.

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

REQUEST FOR INFORMATION (RFI) RFI NO: /WJG

Our wires. & cables INDEX. Insulated wires p2-p3. TAU cables p12-p15. Twisted wires p4-p7. TFA cables p16-p19. Shielded wires p8-p11

SMART LASER SENSORS SIMPLIFY TIRE AND RUBBER INSPECTION

Bill Ham Martin Ogbuokiri. This clause specifies the electrical performance requirements for shielded and unshielded cables.

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

SMD Pulse Transformer for Ethernet Applications. The New Reference LAN Pulse Transformer

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

Chapter 2: Computer Networks

Tru products are now under the Tru-Win brand from Winchester Interconnect.

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

EMI AND BEL MAGNETIC ICM

AVA5-50FX. Product Classification. Standards And Qualifications. Construction Materials. Dimensions. Electrical Specifications

SMD Pulse Transformer for Ethernet Applications. The New Reference LAN Pulse Transformer

AESA TECHNOLOGY OF LAN CABLE

In this section of my blog, I will be discussing different transmission methods and why those particular methods are used in particular situations:

Impact of etch factor on characteristic impedance, crosstalk and board density

LC31L-BAT Link Coupler

CIR (Crush & Impact Resistant) VFD Power Cable

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

The below identified patent application is available for licensing. Requests for information should be addressed to:

MULTIMEDIA & DATA TRANSMISSION

SPORTCRAFT ANTENNAS. INSTALLATION INSTRUCTIONS for FLUSH WINGTIP COM ANTENNAS

Physical Layer. Networked Systems Architecture 3 Lecture 6

Telecommunication Wiring Questions

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

Solution of EMI Problems from Operation of Variable-Frequency Drives

Taking MIM Tooling To the Next Level. Originally published in The American Mold Builder Magazine, February 2014

Transmission Medium/ Media

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

Module 2. Studoob.in - Where Learning is Entertainment

Technician License. Course

Cable Solutions for Servo and Variable Frequency Drives (VFD)

The shunt capacitor is the critical element

Physical Layer. Networked Systems 3 Lecture 5

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

Transcription:

Tailored Insulations for High Transmission Rate Data Cable Ann Watson William Fajardo Ann Watson Borealis Polymers, Belgium William Fajardo Borealis Compounds Inc, ABSTRACT Even with the spread of fibre optical cables into the communication access network, copper symmetrical twisted pair data cables are still at the forefront of today s designs. As transmission rates increase, older multi-purpose insulations may not meet these new demands. Recent tailored solid polyethylene (PE) and polypropylene (PP) formulations for unscreened twisted pair (UTP) cables have provided some distinct advantages for the cable manufacturer. Foamed PE for screened data cables has seen recent advances in the quality of these insulations for Category 7 and Category 7A designs. Physical foaming insulations specifically designed for data cable can now allow manufacturers to optimise their line speeds and minimise scrap rates. This presentation will focus our experience with an optimised range of solid and foamed data cable insulation materials and a new enhanced PP solid insulation for Cat 6A designs. Keywords: data, insulation, solid, foam Figure 1. Evolution of data transmission rates Introduction Historically the first data cable designs evolved from symmetrical multi pair telephone cable or coaxial radio frequency designs, but soon the 4 pair symmetric design became the design of choice for data cables. These cables were initially used to link computer systems together in Local Area Networks (LAN) but now are used for commercial networks, industrial cabling and residential cabling. As the transmission demands have increased so has the data cable operating frequencies. Data cables are therefore categorised according to their working frequencies. The vast majority of data cables installed today are category 6 through to category 7a however newer designs to transmit more data over potentially shorter lengths will operate at 2000MHz or higher. Category Category 3 Category 4 Category 5e Category 6 Category 6a Category 7 Category 7a Category 8 Operating frequency 16 MHz 20 MHz 100 MHz 250 MHz 500 MHz 600 MHz 1000MHz 2000 MHz Figure 2. Data cable categories and operating frequencies 530

Data cable principle design requirements For category data cables there are two generic types of data cable design: unshielded twisted pair (UTP) and shielded twisted pair designs. These are described below in Figure 1. Acronym UTP Full name Unshielded Twisted Pairs 2. Return loss Return loss is a measure of the reflected signals produced by variations or discontinuities in the cable structure in relation to the signal sent, i.e. it is a measure of the reflected energy from a transmitted signal. In a cabling system, return loss also reflects mismatches in the components of the cabling system, including cables, connectors and panels. 3. Internal crosstalk FTP S/FTP S/STP Foil Twisted Pairs Screened / Foil Twisted Pairs Screened / Screened Twisted Pairs Figure 3. Acronyms for unshielded and shielded data cable designs This is the unwanted coupling of signals in adjacent or nearby pairs within a cable. Several different types of crosstalk have been defined. When the degree of reduction in signal strength in the disturbed pair is measured at the same end as the signal input in the disturbing pair, it is called near-end crosstalk (NEXT). Far end crosstalk (FEXT) refers to the measuring of the unwanted signal coupling between pairs in the same cable when the disturbing signal is measured at the receiving end. Both types of crosstalk are related to interference within one symmetric data cable. Several electrical parameters are crucial to monitor to ensure a fit for purpose data cable. 1. Characteristic impedance This is defined as sum of all effects that will impede/inhibit the flow of electricity along the cable. It combines inductive and capacitance (reactive effects) with resistance. The characteristic impedance is a function of the insulation permittivity (dielectric constant) and the cable geometry and is determined by size and spacing of the respective conductors in the pair and the type of dielectric between them. Theoretically impedance is independent of frequency and shielding strongly reduces the impedance. Foamed insulation with lower permittivity is therefore necessary for shielded designs in order to achieve the required dielectric properties within a given insulation diameter. Unshielded Pair Impedance The effect of this unwanted coupling can be controlled or even eliminated by destructive interference between the fields generated by each wire. This is achieved by twisting together the send and return legs of a pair. Similarly, the twist also causes cancelling currents to flow in receiving pairs. However, the twist must be different between interacting pairs, to prevent cumulative coupling occurring at regular intervals along the length of the cable. Shorter lay lengths due to tighter twisting of data cable cores will improve crosstalk but the practical implications in the manufacturing steps can be significant especially with cellular insulation cores that are less resilient than the solid cores in the twinning and twisting processes. 4. Alien Crosstalk This characteristic quantifies the unwanted signal coupling between one or more pairs from one symmetric data cable to an adjacent disturbed data cable. The most effective route identified for minimizing the effect of alien crosstalk is the shielding of pairs, individually or all together. 5. Attenuation Shielded Pair Impedance Attenuation ( ) is defined as the loss in power of an electrical signal, i.e. decrease of signal amplitude as it travels along a pathway. This signal loss is due to limited conductivity of the conductor and dielectric losses. The following equation may be used to calculate attenuation for an unscreened pair. Parameter definitions Permittivity of dielectric ( ) Conductor diameter (d) Conductor separation (s) Distance between balanced pair and ground (h) UTP designs such as cat 6a and below therefore required a solid insulation and shielded designs such as cat 7 and 7a require a foamed insulation. 531 A B are constants Frequency ( ) Permittivity of dielectric ( ) Conductor diameter (d) Conductor separation (s) Di i ti f t

The attenuation defined in decibels (db) is exponential with respect to the cable length. In addition, the attenuation is very dependent on the frequency of cable operation and the dielectric losses are of increasing importance with increased frequency. There are four generic insulation designs for manufacturing telecommunication cable insulation, but only two of which are commonly used today for data cable i.e. the solid and the skin/ foam/skin designs. The next table summarises the variables that can influence a particular electrical property. Some of them have a direct relationship to the dielectric permittivity and even those influential parameters that have a geometric aspect are indirectly influenced by the choice of insulation. Processability and crush resistance will all play a part in the final geometry of the twisted pairs. Solid Foam Electrical property Influential parameter Impedance Return loss Dielectric insulation Permittivity Conductor separation Conductor adhesion Conductor spacing Conductor size Manufacture Impedance (consistency) Foam / Skin Skin/Foam/skin Crosstalk Twisting Shielding Attenuation Frequency Dielectric insulation Permittivity Dissipation factor Total length Shielding Conductor size Insulation thickness Figure 5. Insulation core types Data cable insulation cores At first sight one could ask then why foam an insulation but the key is the decrease in permittivity as the foaming degree increases as illustrated in Figure 4. Foamed insulations are manufactured in one of two ways: chemically or physically foamed. Chemically foamed insulation compounds contain a blowing agent that is activated during the extrusion and thereby releasing a gas which can result in maximum insulation expansion levels up to 45-50%. Physically foamed insulation is achieved through the gas injection process. Today, the vast majority of foamed data cable is Skin/ Foam / Skin design using a triple head gas injection line. A gas injection point in a physical foaming insulation extruder ensures higher expansion level possibilities to lower the permittivity even further than in conventional chemically foamed telecom cores. Optimal material selection can then achieve S/F/S data cable designs with expansion levels between 35-65%. Figure 4. Permittivity (dielectric constant) versus expansion degree for HDPE 532

Data cable insulation material requirements properties Due to the fundamental design requirement of equidistant conductors and the resulting mechanical stresses imposed on the cores during the complete cable manufacturing process; high deformation resistant insulations are a prerequisite to any good data cable. Polyethylene (PE) and to a lesser extent polypropylene (PP) are used today for category data cable insulations. Both have intrinsically low dielectric constants and careful selection can ensure that they have excellent conductor adhesion and good crush resistant properties. The insulation must exhibit good and consistent conductor adhesion as varying adhesion levels will cause geometric imbalances in the core, thereby destroying the data cable s electrical performance. Traditionally, the lower the PE density the better the conductor adhesion, however, the latest HDPE insulations designed specifically for data cable have even better adhesion properties than conventional low density compounds historically used in telephone wire. HDPE insulations have the added benefit of mechanical strength and good Shore D hardness properties to provide protection to the cores during the twinning and twisting manufacturing steps. PP insulations used for data cable insulation generally exhibit good mechanical properties and the latest PP to come onto the data cable market also has very good adhesion properties. Figure 7. Skin/foam/skin cross section with tailored HDPE skin layers encapsulating homogeneous HDPE foam PP can also provide some other benefits, which are becoming more attractive as data cables continue to increase in frequency in order to transmit more information. Individual cores will still be manufactured to geometric tolerances of > 95% but tighter lay lengths will be needed in UTP designs to avoid alien crosstalk and thus more crush resistant insulation materials will be required. The conductor diameters will probably increase to maintain the impedance, thereby higher frequency UTP cable could become bulkier and less easy to install. Potential downsizing of these the insulation by using PP could be a possibility. Newer applications such as power over the internet will mean potentially higher operating temperatures and thereby the selected insulations need to be suitably protected, but still retaining their intrinsic insulation capabilities. Unit PP HDPE Density kg/m3 912 945 Figure 6. Relative conductor adhesion properties using ASTM D 4565, part 19:2004. Conductor Preheater at 140 C for PP and 100 C for the other PE grades Conductor adhesion is critical for solid UTP designs, but perhaps even more so for skin/ foam/ skin designs. In such designs the inner conductor skin separating the conductor from the foam can be as little as 20micron thick and needs to be consistently applied at line speeds of up to 1800 m/min. For foamed insulation, the bubble size and consistency is key to a shielded data cables electrical performance. Careful selection of the insulation compound and compatible inner and outer skin materials is the first step, and learning how best to process the compound on each particular gas injection line is also crucial to achieving the optimal foam structure. The best foamed insulations have thin inner and outer skins, which are of a constant thickness encompassing a strong homogeneous foam structure full of small, fully formed bubbles that provide crush resistance during the downstream twinning / twisting processes. Such an example is as illustrated in figure 7. MFR2 (230 C) MFR2 (190 C) g/10min 3.0 - g/10min - 0.7 Dielectric C At 1MHz 2.26 2.32 Shore D 15sec Tensile strength* Tensile Elongation* 70 58 Mpa 56 35 % 780 700 Table 8. Comparison of critical material properties for a Solid PP and HDPE data cable insulation * Performed on stripped cable isolation, Cu 0.53mm / OD 0.94mm PP processing at has the reputation of being more difficult that HDPE and this can be the case, but with the use of optimised temperature profiles and tooling this issue can be resolved. To illustrate we extruded both solid PP and HDPE data cable insulations on a pilot line. 533

Data core construction: 0.53 mm copper diameter 0.94 mm outer core diameter. Extruder type: Francis Shaw (licence Davis Standard) 63,5mm, 22 L/D with a medium compression screw with no mixing devices. Drive was 40bhp (29, 8 kw) geared to 100rpm maximum screw speed Reference HDPE data cable insulation was extruded at approximately 1000m/min with a screw speed of 54 rpm. Using the same tooling, and a conventional gradient PP temperature profile we could maintain 1000m/min but at the machine maximum of 100rpm. The screw output per revolution (specific output) of the PP was lower than the HDPE and in order to increase the line speed further we had to address this. This was done by using a reverse temperature profile shown in table 9 and now a reduced screw speed of 81rpm was required to reach 1000m/min. The next step was to modify the die and we increased the die diameter from 0.95 to 1.00 mm and the die body length from 25 mm to 30 mm. These die modifications in combination with the reverse temperature allowed the PP specific output to increase further and only 51rpm were required to achieve 1000m/min. Material HDPE Data impact of processing parameters PP DATA PPDATA impact of die size Conclusions Extruder Temperat ure Profile [ C] 170-190- 200-170 Die Length Diamet er Extr. Line Press Speed. [m/mi [bar] n] 460 1025 54 Scre w Spee d [rpm] 490 1000 100 409 1016 81 (30mm PP DATA 266 1006 51 1m Table 9. Pilot line study to optimise PP line speed By using tailor made insulations robust data cable designs are possible that not only meet the increasing transmission demands, but can be produce at the fast line speeds used on the newest data cable insulating lines. Superior conductor adhesion is critical for a data cable s performance and the development of tailor made HDPE for solid insulation for UTP designs has ensured excellent adhesion along with a mechanical resilience during manufacture. This HDPE data cable insulation is unique in that it is also successfully used as both the inner and outer skin of skin / foam/ skin insulation used for physically foamed shielded designs. These cores are mechanically stronger to face the downstream mechanical forces exerted on the insulated wires as they are twinned and twisted into 4 twisted pairs. The use of just one skin material for both layers simplifies the insulating line material logistics. A new PP insulation specifically designed for UTP cable satisfies the superior adhesion requirements, and the extra mechanical robustness allows for new smaller lay length designs to be manufactured. Finally the current generation of physical foamed HDPE is providing the process stability and fine and homogeneous cell structure that are required to produce cat 7 and Cat 7a cores at speeds of 1500m/min or more. This material is also supporting the realisation of new Cat 8 designs. 9. Authors Bill Fajardo Bill has a broad background in the wire and cable industry over the past twenty-five years through polymers, mineral fillers and compounding. Bill s background experience in LDPE, PP and EVA resins with Rexene Resins along with compounding experience in both rubber and plastic based materials are a good fit to providing technical support for cable applications. For the past 15 years Bill has been with Borealis Compounds Inc. He has had the technical responsibility for support to the Telecommunication, Power Cable, Low Voltage, and Automotive markets. Bill has a B.Ch.E. in Chemical Engineering from the University of Dayton and is an active member in the Institute of Electrical and Electronics Engineers (IEEE), and is on several working groups within the Power Engineering Society Insulated Conductors Committee (PES-ICC), the Society of Automotive Engineers (SAE) and the Society of Plastics Engineers (SPE). Email: bill.fajardo@borealisgroup.com Ann Watson Ann Watson studied Chemical Engineering at Heriot-Watt University in Edinburgh. Graduating in 1987, she joined Neste Chemicals in Beringen, Belgium as a Process Engineer for the start up of their Spheripol polypropylene plant. In 1990 she moved to BP Chemicals as a Process Development Engineer in the wire and cable LDPE plant in Antwerp, supporting the reactor and compounding process and product development. This plant subsequently became part of Borealis in 1994 and since then Ann has remained within the Borealis wire and cable business in both technical and commercial functions. Today as Application Technology Manager she specialises in the application of materials for communication cable and also provides technical service to communication and power cable manufacturers in Europe. Email: ann.watson@borealisgroup.com 534