Technical Guide M. MMultiSlide Doors. Technical Guide M1

Similar documents
MultiSlide Doors. Seamless Indoor/Outdoor Spaces. Nelson Cabin - courtesy Stefan Hampden of CAST architecture

Landmark Builders of Montana LANDMARK RESIDENCE TECHNICAL GUIDE L LIFTSLIDE DOORS

Technical Guide E. EDouble/Single Hung Windows. Technical Guide E1

Lift & Slide W6400. (rev )

MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION

WA7000. (rev )

WA7000. (rev )

COMMERCIAL SOLUTIONS. Commercial door solutions

LEADING WINDOW & DOOR SYSTEMS

Marvin Patio Doors VALUE THROUGH AND THROUGH

about us PLYGEM

INTRODUCING NEW SIZES FOR MARVIN DOORS

General Information... Elevation Notes... Elevation Notes Transom... Light Cut Information... Clear Opening Design Data Table 1 & 2 Panel...

STEEL WINDOWS & DOORS PRODUCT GUIDE

Featuring classic style combined with the latest in innovative window technology, the Sierra Pacific aluminum clad. Carmel Double Hung

FOLDING GLASS WALL SYSTEMS

CLEAR GLASS WALL SYSTEMS

CLEAR GLASS WALL SYSTEMS

HH Windows & Doors German engineered. American made. the horizontal pivot window

WOOD AND CLAD ULTIMATE SLIDING FRENCH DOOR. Table of Contents

Superior by Design. Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL FOLDING SLIDING STACKING PIVOT

YSD 400 Sliding Door System Installation Manual

System Width. Panel Width

Masonite Steel Entry Doors

Weather Shield Awning and Scena Vu Wood Window Parts Reference Catalog

k o l U l t r a P o c k e t D o u b l e H u n g

NEW ULTIMATE CASEMENT AND AWNING COLLECTION

UNIVERSITY SERIES Fixed, Projected and Casement Steel Windows

Series 7650 Installation Instructions Sliding Glass Door

Quote D: Richards Lake Home Project: studio b elements Printed: 6/9/2014 2:47:45 PM

Imagine a front entrance that is distinctively yours. Upstate Door will work with

Architectural detail manual Classic Wood Awning Windows

Wood Facade Systems. Made in the U.S.A. Curtain Walls Skylights & Structures Doors & Windows.

UNIT SECTIONS Aluminum-Clad Exterior Wood Collection

Alfresco LIVING. Just got better DESIGNERLINE PRODUCT RANGE QUEENSLAND

Series 9000 Vinyl Horizontal Slider

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

Product Presentation

ASPEN 530 T SINGLE HUNG. Each lite of glass was channel glazed with a reducing vinyl gasket.

Andersen Complementary Clad Casement Windows (2005 to Present)

KEY FEATURES HARDWARE ICON BI-FOLD OPERATOR

Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing)

Product Samples. Window and Patio Door Sample options. SECOND TO NONE.

SovereignSeries. SovereignSeries

INSTALLATION GUIDE WOOD PIVOTING CIRCLE/ OVAL

DF COLLECTION. Architectural Detail Guide Double-Hung Window DF 3604 TABLE OF CONTENTS

SERIES 5001 SLIDING GLASS DOOR PATIO DOORS INSTALLATION GUIDE

Architectural detail manual Double-Hung window DF3604

System Width O X X O. Primary Panel. Exterior View DUE TO SYSTEM EXCEEDING JOB NAME 300", SPLITS WILL BE PRESENT IN THE TOP/BOTTOM TRACKS.

182.1 INTRODUCTION SERIES 462 ARCHITECTURAL COMMERCIAL SLIDING WINDOW. Design Features : Australian Registered Design.

Mira Premium Series Bi-Parting French Sliding Patio Door Installation Instructions

Panel Assembly and Installation

Series 9000 Vinyl Single Hung

TESTED FOR Report No. : A04H-009 Date : February 10, 2004 FLEETWOOD ALUMINUM PRODUCTS, INC. Page : 1 of Railroad Street Corona, CA 91720

Est Aluminium Profile Stockists

7500/7550 Series Casement Windows (2002 to 2010)

1010 Sliding Mall Front

Andersen Complementary Clad French Casement Windows (2005 to Present) What's in This Section. Clad French Casement Windows...

Door & Window Systems

Architectural Information Page: Series 541 Sliding Door Introduction

Series 6000 Vinyl Horizontal Slider

SITELINE CLAD-WOOD WINDOW CASEMENT TABLE OF CONTENTS

System Width. Primary Panel. System Height. Panel Height " Finger Pulls Ht. from F.F. AWLS - PX - Exterior Elevation

E N T R A N C E W A Y S

170 Sliding Patio Door available Styles

Installation Guidelines for all Quaker products with nail fins New Construction nail fin installation with a Zip sheathing system.

Dear Contractor, I am glad that you are interested in our window rebate program.

2.01 Standard Entrances Description

System Width. AWLS - OXX with 2 Screens - Exterior Elevation

Style Line Series. Vinyl Windows. Architectural Manual

COMMERCIAL STEEL AND ALUMINUM SECTIONAL DOORS

JAMESTOWN175 SERIES Fixed, Projected and Casement Steel Windows

4300Wi WOOD INTERIOR CASEMENT VINYL WINDOW gerkin.com

Air Infiltration The amount of air leaking in and out of a building through cracks in walls, windows, and doors.

Visions 2000 Single Hung Tilt Window Parts Reference Catalog

AA TM 3900 THERMAL SLIDING DOOR

Series 424 CentreGLAZE Framing

WOOD AND CLAD COMMERCIAL DOOR WOOD AND CLAD 2 1/4 COMMERCIAL DOOR. Table of Contents

Quantum Sliding Door. Features & Benefits. Trend Windows & Doors Design Manual Q-Mk-1 May 2014

Built to Order. Stiles. StileLine. Steel Storefront. Features. Glass. Finishing. Section Contents

Definitions and Design Considerations... W-CR-2

Architectural Manual. Vinyl Windows & Patio Doors

6400, 8400 and 9400 Series Sliding Patio Door

ASSEMBLY AND INSTALLATION INSTRUCTIONS for Multi-Slide Door Systems (JII043) IMPORTANT INFORMATION AND GLOSSARY. Considerations Before Installation:

THE SMART ALTERNATIVE TO VINYL. 100 SERIES WINDOWS & DOORS

Contemporary 3 Panel Classic 5 Panel French Panel

Curtain Wall Installation Guide

Bovard Studios Inc. Section April 6, 2004 Page 1

EPICVUE CLAD-WOOD WINDOW CASEMENT TABLE OF CONTENTS

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL

L A N D M A R K K. C O M R E S I D E N T I A L A R C H I T E C T U R E

Rhino series thermally broken 2 3/8" aluminum windows Information book

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

Legend W White B Bronze S Silver (Gray) K Black M Mill. Figure

Architectural Information Page: Series 602 Magnum Sliding Window Introduction. Design Features : Date: Aug 03 Replaces: Scale: Not to scale

POCKETING MULTI-SLIDE DOOR SYSTEM

CUSTOM VINYL WINDOWS

STANDARD ENTRANCES TECHNICAL MANUAL

VINYL-COMPOSITE SWING DOOR SYSTEMS

Designed for Your Life. Guaranteed. Premium Vinyl Replacement Windows

Transcription:

Technical Guide M MultiSlide Doors M Technical Guide M1

Loewen MultiSlide MultiSlide doors provide large dramatic openings for the transition from indoor and outdoor living spaces. With an easy, smooth and quiet operation, using stainless steel tracks, MultiSlide interlocking sliding panels provides secure and weatherproof options in large openings. A large selection of custom configurations and design options are available, including bi-parting and hidden pocketing. Loewen narrow stile and rail panels provide a contemporary look with a narrow stile 2 face width. This width is narrower than many sliding door programs while still incorporating an available flush handle and multipoint locking mechanism. Also available in the wide 4 5/16 stile. The panel construction, using authentic Loewen door components, results in a cohesive aesthetic with other Loewen product lines. Standard Features Standard panel heights up to feet. Standard panel widths up to 5 feet; custom sizes available. Natural Douglas Fir interior (no visible finger joints). LowE insulated tempered glazing. 2 " (58 mm) thick sliding panels. Extruded aluminum cladding in all palette colors including anodized. Standard bronze anodized sill with built in drainage system. Metal clad jamb fillers and frame cladding match clad door panels. Glass & Glazing A wide variety of glazing options available including triple glazed. LowE Double and LowE Triple. Exterior Simulated Divided Lites options available in Putty, Ogee and Square. Interior SDL and stops options include Ogee, Square and Putty. Hardware Multipoint locking door handles are available in a variety of styles and finishes. See section A. Our unique 2 ¼ thick panel adds superior thermal performance, as well as strength and durability. The high structural integrity and raised threshold options allow MultiSlide doors to be located in areas of moderate to high exposure where homeowners want a broad view with no visual interference mountain, hillside or lake-front vistas. Multi track thermally broken frame and sill is available in raised sill with no riser, 1 riser and 1 riser for best performance. Doors can be clad in a variety of colors from the extensive Loewen palette, and are available in Douglas Fir or in Mahogany interiors. Simulated Divided Lites (SDL) Ogee Profile. Putty Profile. Square Profile (interior only) Track Assembly Available in bronze anodized finish only. Multi track thermally broken frame and sill is available in raised sill with no riser, 1 riser and 1 riser. Metal Clad Color Spectrum All palette colors including anodized. M2 Technical Guide

Specifications Standards Most units have been tested by an independent laboratory for air and water infiltration, structural performance and thermal performance. Manufactured from Coastal Douglas Fir kiln-dried lumber. The entire Loewen product line is also available in optional Mahogany. Preservative Treated All wood parts are dipped in approved low VOC preservative. Door s panel is equipped with two sets of adjustable ball bearing tandem rollers. Sash is 2 " (58 mm) thick for extra strength and durability. Glazing With countless glazing configurations and LowE coating options, we ensure that you can choose the perfect blend of protection and comfort. Insulating Glass Double or triple insulating tempered glass configuration, with " ( mm) airspace. LowE Systems LowE best describes the benefits of the product that incorporates glazing coatings and Argon gas. LowE systems help reduce heating and cooling costs, providing superior energy efficiency. Simulated Divided Lites (SDL) Standard SDL complete with airspace grilles. Grille bars are permanently applied to the interior and exterior. Flush handle Exterior pull Multipoint handle system Sample Configurations STACKING POCKETED 0XX PXX 0XXX 0XXXX X 0XXXXXXX XXXXX 0X - X0 PXX - XXP 0XX - XX0-0XXX - XXX0 X - X X = Operating 0=Fixed P=Pocket Standard Features Stacking: 8 panels max (left or right in a single direction) Metal Cladding Heavy duty exterior metal cladding comprised of extruded aluminum is available in a variety of palette colors. Interiors of door are natural wood, unfinished or primed. Metal clad units are supplied ready-to-install complete with optional metal nailing flange. Sill Track Extruded metal sill with stainless steel cap over operating track for ease of operation and long-lasting performance. An internal weep system with drainage holes keeps water out of the interior trough. Hardware Multi-point locking hardware, in patio and flush handle styles. The locking hardware is also available in several optional finishes. Stainless steel roller assemblies are optional. Bi-Parting: 4 panels left, 4 panels right (8 in total) Pocket: max 8 panels stacking or bi-parting Technical Guide M3

Multislide Narrow Stile Stacking 48 [1224] 69 [1762] 72 [1859] 5 [2674] 8 7/16 [3517] 171 [4358] 204 3/4 [5201] 237 [42] 271 [6884] 120 [3052] 177 5/16 [4504] 234 [5957] 289" [7341] System 47 [1199] 68 [1737] 71 [1807] 4 [2649] 7 7/16 [3492] 170 [4333] 203 3/4 [5176] 2 [17] 270 [6859] 119 [3027] 176 5/16 [4479] 233 [5932] 288 [7315] 24 [6] 24 [6] 59 7/16 [15] R.O Jamb 7 [188] 7 [188] 16 [416] 19 [492] 22 [569] 25 [645] 7 [188] 16 [416] 39 [994] 38 [981] X X XX XX XXX XXX XXXX X 63 [14] 62 [1591] X X XX XX XXX XXX XXXX X 87 [2214] 99 [2518] 86 11/16 [2201] 98 84 [24] 96 [2438] X X X XX X XX XX XXX XX XXX XXX XXXX XXX XXXX X X 111 [2823] 1 [28] 8 [2743] X X XX XX XXX XXX XXXX X 123 [3128] 122 [3115] 120 [3048] X X XX XX XXX XXX XXXX X Minimum Dimensions - 2' x 3' Minimum Dimensions - 5 x Maximum System - 24' Note: The preparation of the rough opening for large openings such as those required by, but not limited to, LiftSlide, Bifold and MultiSlide doors have unique requirements. Structural headers that allow for deflection no greater than along the unsupported length once the header is fully loaded are required. Special care needs to be taken when installing any unit including transoms above such large opening units. Loewen is not responsible for site measurements or the determination of structural and architectural requirements for the installation of large opening products such as but not limited to, LiftSlide, Bifold and MultiSlide doors. Site specifications are the responsibility of building professionals or engineers to determine. M4 Technical Guide

Multislide Wide Stile Stacking 46 [1184] 66 [1683] 70 [1794] 2 [2597] 3 [3401] 165 [4204] 197 [5008] 228 3/4 [5811] 2 7/16 [6614] 118 [30] 174 [4426] 229 [5839] 285 [7252] System 45 [1159] 65 [1658] 69 [1769] 1 [2572] 2 [3375] 164 [4179] 196 [4982] 227 3/4 [5786] 259 7/16 [6589] 117 [2988] 173 [4401] 228 [5814] 284 [7227] 24 [6] 24 [6] R.O Jamb 7 [188] 7 [188] 16 [416] 19 [492] 22 [569] 25 [645] 7 [188] 16 [416] 39 [994] 38 [981 X X XX XX XXX XXX XXXX X 63 [14] 62 [1591 X X XX XX XXX XXX XXXX X 87 [2214] 99 [2518] 86 11/16 [2201 98 [2505 84 [24] 96 [2438] X X X XX X XX XX XXX XX XXX XXX XXXX XXX XXXX X X 111 [2823] 1 [28 8 [2743] X X XX XX XXX XXX XXXX X 123 [3128] 122 [3115] 120 [3048] X X XX XX XXX XXX XXXX X Minimum Dimensions - 2' x 3' Minimum Dimensions - 5 x Maximum System - 24' Note: The preparation of the rough opening for large openings such as those required by, but not limited to, LiftSlide, Bifold and MultiSlide doors have unique requirements. Structural headers that allow for deflection no greater than along the unsupported length once the header is fully loaded are required. Special care needs to be taken when installing any unit including transoms above such large opening units. Loewen is not responsible for site measurements or the determination of structural and architectural requirements for the installation of large opening products such as but not limited to, LiftSlide, Bifold and MultiSlide doors. Site specifications are the responsibility of building professionals or engineers to determine. Technical Guide M5

Multislide Stacking Door Detail Head & Sill Detail Optional Risers METAL CLAD - NARROW STILE (OX) METAL CLAD - WIDE STILE (OXX) Plan View Glazing Stop Profiles Double METAL CLAD - NARROW STILE (OX) Triple METAL CLAD - WIDE STILE (OXX) Note: Drawings shown are typical details. Additional sizes and configurations available. Screen options may be available depending on size and configuration. All dimensions to have +/- 1/16" (2 mm) tolerance. The preparation of the rough opening for large openings such as those required by, but not limited to, LiftSlide, Bifold and MultiSlide doors have unique requirements. Structural headers that allow for deflection no greater than along the unsupported length once the header is fully loaded are required. Special care needs to be taken when installing any unit including transoms above such large opening units. Loewen is not responsible for site measurements or the determination of structural and architectural requirements for the installation of large opening products such as but not limited to, Liftslide, Bifold and MultiSlide doors. Site specifications are the responsibility of building professionals or engineers to determine. M6 Technical Guide

Multislide Narrow Stile - Stacking With Pocket 52 [44] 74 [1883] 76 [1953] 1 [2795] 143 [] 176 5/16 [4478] 209 7/16 [5320] 242 [6162] 275 3/4 [7004] 289 [7341] 124 [3172] 182 1/16 [4625] 239 [76] 289 [7341] System 51 [19] 71 [1818] 75 [1927] 9 [2769] 142 [11] 175 5/16 [4533] 208 7/16 [5295] 241 [67] 274 3/4 [6979] 288 [7215] 123 [3147] 181 1/16 [4599] 238 [51] 288 [7315] Framed 27 " [709] 49 [1247] 39 [] 73 1/16 [1855] 6 [2697] 9 5/16 [3539] 172 [4381] 205 [5223] 238 3/4 [65] 254 [6457] 63 [1623] 121 1/16 [3075] 178 [4527] 229 R.O 24 [6] 24 [6] 33 3/4 [858] 58 [1487] Pocket 4 7 [178] 4 7 [178] [254] [330] 16 [406] 19 [483] 22 [559] 25 [635] 4 7 [178] [254] [330] Jamb 4 [111] 7 [187] 4 [111] 7 [188] 16 [416] 19 [492] 22 [569] 25 [645] 4 [111] 7 [187] 39 [994] 38 [981] PX XP PXX XXP PXX XXP X X XX XX XXX XXX XXX XXX XXXXX XXXXX PXX XXP X X 63 [14] 62 [1591] PX XP PXX XXP X X XX XX XXX XXX XXX XXX XXXXX XXXXX PXX XXP X X 87 [2214] 99 [2518] 86 11/16 [2201] 98 [2505] 84 [24] 96 [2438] X X X X XX XX XX XX XXX XXX XXX XXX XXX XXX XXX XXX XXXXX XXXXX PXX XXP XXXXX XXXXX PXX XXP X X X X 111 [2823] 1 [28] 8 [2743] X X XX XX XXX XXX XXX XXX XXXXX XXXXX PXX XXP X X 123 [3128] 122 [3115] 120 [3048] X X XX XX XXX XXX XXX XXX XXXXX XXXXX PXX XXP X X Minimum Dimensions - 2' x 3' Minimum Dimensions - 5 x Maximum System - 24' Note: The preparation of the rough opening for large openings such as those required by, but not limited to, LiftSlide, Bifold and MultiSlide doors have unique requirements. Structural headers that allow for deflection no greater than along the unsupported length once the header is fully loaded are required. Special care needs to be taken when installing any unit including transoms above such large opening units. Loewen is not responsible for site measurements or the determination of structural and architectural requirements for the installation of large opening products such as but not limited to, LiftSlide, Bifold and MultiSlide doors. Site specifications are the responsibility of building professionals or engineers to determine. Technical Guide M7

Multislide Wide Stile - Stacking With Pocket 52 [44] 72 [1844] 76 [1953] 8 [2756] 140 [35] 176 5/16 [4478] 203 [5166] 235 1/16 [5970] 266 11/16 [6774] 289 [7341] 124 [3172] 180 [4586] 2 [00] 289 [7341] System 51 [19] 71 [1818] 75 [1927] 7 [2730] 9 [3534] 175 5/16 [4533] 202 [5141] 234 1/16 [5945] 265 11/16 [6748] 288" [7315] 123 [3147] 179 [45] 235 [5974] 288 [7315] Framed 27 [709] 47 [1208] 39 [] 71 [1816] 3 [2620] 9 1/16 [3539] 166 [4226] 198 1/16 [5030] 229 11/16 [5834] 253 [6457] 63 [1623] 119 [30] 175 [4450] 228 R.O 24 [6] 24 [6] 34 [858] 59 7/16 [15] Pocket 4 7 [178] 4 7 [178] [254] [330] 16 [406] 19 [483] 22 [559] 25 [635] 4 7 [178] [254] [330] Jamb 4 [111] 7 [187] 4 [111] 7 [188] 16 [416] 19 [492] 22 [569] 25 [645] 4 [111] 7 [187] 39 [994] 38 [981] PX XP PXX XXP PXX XXP X X XX XX XXX XXX XXXX XXXX XXXXX XXXXX PXX XXP X X 63 [14] 62 [1591] PX XP PXX XXP PXX XXP X X XX XX XXX XXX XXXX XXXX XXXXX XXXXX PXX XXP X X 87 [2214] 99 [2518] 86 11/16 [2201] 98 [2505] 84 [24] 96 [2438] PXX XXP PXX XXP X X X X XX XX XX XX XXX XXX XXX XXX XXXX XXXX XXXX XXXX XXXXX XXXXX PXX XXP XXXXX XXXXX PXX XXP X X X X 111 [2823] 1 [28] 8 [2743] PXX XXP X X XX XX XXX XXX XXXX XXXX XXXXX XXXXX PXX XXP X X 123 [3128] 122 [3115] 120 [3048] PXX XXP X X XX XX XXX XXX XXXX XXXX XXXXX XXXXX X X XX XX Minimum Dimensions - 2' x 3' Minimum Dimensions - 5 x Maximum System - 24' Note: The preparation of the rough opening for large openings such as those required by, but not limited to, LiftSlide, Bifold and MultiSlide doors have unique requirements. Structural headers that allow for deflection no greater than along the unsupported length once the header is fully loaded are required. Special care needs to be taken when installing any unit including transoms above such large opening units. Loewen is not responsible for site measurements or the determination of structural and architectural requirements for the installation of large opening products such as but not limited to, LiftSlide, Bifold and MultiSlide doors. Site specifications are the responsibility of building professionals or engineers to determine. M8 Technical Guide

Multislide Stacking With Pocket Door Detail Head & Sill Detail METAL CLAD - NARROW STILE (X) METAL CLAD - WIDE STILE (PX) Plan View METAL CLAD - NARROW STILE (X) METAL CLAD - WIDE STILE (PX) Note: Drawings shown are typical details. Additional sizes and configurations available. Screen options may be available depending on size and configuration. All dimensions to have +/- 1/16" (2 mm) tolerance. The preparation of the rough opening for large openings such as those required by, but not limited to, LiftSlide, Bifold and MultiSlide doors have unique requirements. Structural headers that allow for deflection no greater than along the unsupported length once the header is fully loaded are required. Special care needs to be taken when installing any unit including transoms above such large opening units. Loewen is not responsible for site measurements or the determination of structural and architectural requirements for the installation of large opening products such as but not limited to, Liftslide, Bifold and MultiSlide doors. Site specifications are the responsibility of building professionals or engineers to determine. Technical Guide M9

Multislide Narrow Stile - Bi-Parting 93 [2384] 1 [3459] 141 3/4 [00] 208 [5283] 274 5/16 [6967] 237 1 [40] 289 [7341] System 92 [2359] 5 [3434] 140 3/4 [3575] 207 [5258] 273 5/16 [6942] 2 1 [15] 288 [7315] 24 [6] 24 [6] 49 [1257] R.O Jamb 7 [188] 7 [188] 7 [188] 39 [994] 38 [981] OX-XO OXX-XXO OX-XO OXX-XXO - OX-XO OXX-XXO 63 [14] 62 [1591] OX-XO OXX-XXO OX-XO OXX-XXO - OX-XO OXX-XXO 87 [2214] 99 [2518] 86 11/16 [2201] 98 [2505] 84 [24] OX-XO OXX-XXO - OX-XO OXX-XXO 96 [2438] OX-XO OXX-XXO - OX-XO OXX-XXO 111 [2823] 1 [28] 8 [2743] OX-XO OXX-XXO - OX-XO OXX-XXO 123 [3128] 122 [3115] 120 [3048] OX-XO OXX-XXO - OX-XO OXX-XXO Minimum Dimensions - 2' x 3' Minimum Dimensions - 5 x Maximum System - 24' Note: The preparation of the rough opening for large openings such as those required by, but not limited to, LiftSlide, Bifold and MultiSlide doors have unique requirements. Structural headers that allow for deflection no greater than along the unsupported length once the header is fully loaded are required. Special care needs to be taken when installing any unit including transoms above such large opening units. Loewen is not responsible for site measurements or the determination of structural and architectural requirements for the installation of large opening products such as but not limited to, LiftSlide, Bifold and MultiSlide doors. Site specifications are the responsibility of building professionals or engineers to determine. M Technical Guide

Multislide Wide Stile - Bi-Parting 90 1 [2307] 129 [3301] 8 11/16 [3523] 201 [5129] 264 [67] 234 3/4 [5963] 289 [7341] System 89 1 [2281] 128 [3434] 7 11/16 [3497] 200 [54] 263 [6711] 233 3/4 [5937] 288 [7315] 24 [6] 24 [6] 50 [1283] R.O Jamb 7 [188] 7 [188] " 7 [188] 39 [994] 38 [981] OX-XO OXX-XXO OX-XO OXX-XXO - OX-XO OXX-XXO 63 [14] 62 [1591] OX-XO OXX-XXO OX-XO OXX-XXO - OX-XO OXX-XXO 87 [2214] 99 [2518] 86 11/16 [2201] 98 [2505] 84 [24] OX-XO OXX-XXO - OX-XO OXX-XXO 96 [2438] OX-XO OXX-XXO - OX-XO OXX-XXO 111 [2823] 1 [28] 8 [2743] OX-XO OXX-XXO - OX-XO OXX-XXO 123 [3128] 122 [3115] 120 [3048] OX-XO OXX-XXO - OX-XO OXX-XXO Minimum Dimensions - 2' x 3' Minimum Dimensions - 5 x Maximum System - 24' Note: The preparation of the rough opening for large openings such as those required by, but not limited to, LiftSlide, Bifold and MultiSlide doors have unique requirements. Structural headers that allow for deflection no greater than along the unsupported length once the header is fully loaded are required. Special care needs to be taken when installing any unit including transoms above such large opening units. Loewen is not responsible for site measurements or the determination of structural and architectural requirements for the installation of large opening products such as but not limited to, LiftSlide, Bifold and MultiSlide doors. Site specifications are the responsibility of building professionals or engineers to determine. Technical Guide M11

Multislide Bi-Parting Door Detail MULTISLIDE DOOR: BI-PARTING DETAIL MULTISLIDE DOOR: BI-PARTING MULTISLIDE MULTISLIDE HEAD DETAIL AND DOOR: SILL DOOR: DETAIL BI-PARTING BI-PARTING DETAIL DETAIL Frame 11 11/16" [297mm] HEAD AND SILL DETAIL Jamb " [264mm] Head & Sill Detail 4 " [5mm] 3 " [98mm] HEAD HEAD AND AND SILL SILL DETAIL DETAIL " [16mm] 4 " [5mm] 3 " [98mm] 4 " [5mm] 3 " [98mm] 2 " [73mm] " [16mm] 2 " [73mm] " [16mm] 4 " [5mm] 3 " [98mm] 2 " [73mm] 2 " [73mm] Plan View Plan Plan View Plan View View Plan View Frame 11 11/16" [297mm] Frame 11 11/16" [297mm] Jamb " [264mm] Jamb " [264mm] Jamb " [264mm] 2 " 11/16" [73mm] [17mm] 2 " [73mm] " [16mm] 2 " [73mm] 2 " [73mm] Frame 11 11/16" [297mm] Frame Sill 1" [275mm] Sill 1" [275mm] Sill Sill 1" [275mm] 1" [275mm] METAL CLAD - NARROW STILE METAL CLAD -(OXX-XXO) NARROW STILE METAL CLAD METAL - NARROW CLAD - NARROW STILE STILE (OXX-XXO) (OXX-XXO) (OXX-XXO) Frame 1 5 " [142mm] 5 5/16" [5mm] Frame Frame " [16mm] 5 5/16" [5mm] 4 5/16" [1mm] 4 " [8mm] " [16mm] 5 " [142mm] Frame 8 11/16" [221mm] Frame 8 11/16" [221mm] Jamb 7 " [188mm] Frame 8 11/16" [221mm] 4 5/16" 5 " [1mm] [142mm] 4 " [8mm] 5 5/16" [5mm] 5 " [142mm] 5 5/16" [5mm] " [16mm] " [16mm] 4 5/16" [1mm] 4 " [8mm] 5 " [142mm] 4 5/16" [1mm] 5 5/16" [5mm] 4 " [8mm] Jamb 7 " [188mm] 1 " [32mm] Jamb 7 " [188mm] Jamb 7 " [188mm] 1 " [32mm] 1 " [32mm] " [16mm] 4 " [8mm] Sill 7 Sill 1" [199mm] 7 1" [199mm] Frame 8 11/16" [221mm] Jamb 7 " [188mm] Frame 8 11/16" [221mm] 4 5/16" [1mm] Screen Frame 1 " [32mm] Frame Screen 1 1/16" [28mm] Frame 1 1/16" [28mm] Screen Sill 7 1" [199mm] METAL CLAD - WIDE STILE VISTA METAL VIEW CLAD SCREEN - WIDE STILE METAL CLAD METAL - WIDE CLAD STILE - WIDE STILE VISTA (OX-XO) VIEW SCREEN VISTA VIEW VISTA SCREEN VIEW SCREEN (OX-XO) (OX-XO) (OX-XO) Optional Risers OPTIONAL RISERS OPTIONAL OPTIONAL RISERS RISERS Screen Frame Frame 1 " [29mm] 3/4" [19mm] 1 " [29mm] 3/4" [19mm] 1 " [29mm] 3/4" [19mm] 1 " [29mm] 3/4" [19mm] 1 1/16" [28mm] 1 1/16" [28mm] Sill 7 1" [199mm] Sill 7 1" [199mm] Screen 1 1/16" [28mm] 1 " [32mm] OPTIONAL RISERS 2 " [75mm] 2 " [75mm] 1 5/16" [33mm] " [264mm] 2 3/4" [70mm] 1 5/16" [33mm] 7 " [188mm] 1 5/16" [33mm] " [264mm] 2 3/4" [70mm] 1 5/16" [33mm] 7 " [188mm] 2 " [75mm] 2 " [75mm] 1 " [32mm] 5 " [140mm] 4 5/16" [1mm] 4 " [111mm] 6 7/16" [163mm] 6 7/16" [163mm] 2 " [75mm] 2 " [75mm] 2 " [75mm] 2 " [75mm] 4 1/16" [3mm] 11/16" 4 1/16" [17mm] [3mm] 2 " [75mm] 2 " [75mm] 2 3/4" [70mm] 1 " [32mm] 1 " [32mm] 1 5/16" [33mm] 7 " [188mm] 1 5/16" [33mm] " [264mm] 2 3/4" [70mm] 1 5/16" [33mm] 7 " [188mm] 1 5/16" [33mm] " [264mm] 4 1/16" [3mm] 4 1/16" [3mm] Frame 4 1/16" [3mm] 4 1/16" [3mm] R.O. Frame Frame 2 3/4" [70mm] 1 5/16" [33mm] 7 " [188mm] 1 " [32mm] R.O. R.O. 4 1/16" [3mm] METAL CLAD - NARROW STILE 4 1/16" [3mm] (OXX-XXO) METAL CLAD METAL - NARROW CLAD - NARROW STILE Screen STILE Frame (OXX-XXO) (OXX-XXO) Screen R.O. Screen Screen GLAZING STOP OPTIONS METAL CLAD - NARROW STILE (OXX-XXO) GLAZING GLAZING STOP OPTIONS STOP OPTIONS GLAZING STOP OPTIONS 4 5/16" [1mm] Screen 1 " [32mm] 5 " [140mm] 5 " [140mm] 5 " [140mm] 4 5/16" [1mm] 4 5/16" [1mm] 4 " [111mm] 4 " [111mm] 5 " [140mm] 2 " [75mm] 2 " [75mm] 4 5/16" [1mm] 4 " [111mm] Frame R.O. Frame Frame R.O. Frame R.O. METAL CLAD - WIDE STILE 4 " [111mm] VISTA VIEW SCREEN R.O. METAL CLAD - WIDE STILE (OX-XO) METAL CLAD - WIDE STILE VISTA VIEW SCREEN VISTA VIEW SCREEN METAL CLAD - WIDE STILE (OX-XO) (OX-XO) VISTA VIEW SCREEN (OX-XO) Frame 6 7/16" [163mm] 6 7/16" [163mm] 5 " [140mm] 5 " [140mm] 5 " [140mm] 2 " [75mm] 2 " [75mm] 2 " [56mm] 2 " [56mm] SQUARE SQUARE 2 " [56mm] 5 " [140mm] 2 " [56mm] 2 " [56mm] 5 " [140mm] 2 " [75mm] OGEE OGEE 2 " [75mm] 2 " [56mm] GLAZING STOP OPTIONS 2 " [56mm] 2 " [56mm] SQUARE 2 " [56mm] OGEE PUTTY PUTTY SQUARE 2 " [56mm] SQUARE 2 " [56mm] OGEE 2 " [56mm] PUTTY 2 " [56mm] PUTTY 2 " [56mm] PUTTY R.O. 2 " [56mm] Note: Drawings shown are typical details. Additional sizes and configurations available. METAL CLAD - WIDE STILE VISTA VIEW SCREEN (OX-XO) Screen options may be available depending on size and configuration. All dimensions to have +/- 1/16" (2 mm) tolerance. The preparation of the rough opening for large openings such OGEE as those required by, but not limited to, LiftSlide, Bifold and MultiSlide doors have unique requirements. Structural headers that allow for deflection no greater than along the unsupported length once the header is fully loaded are required. Special care needs to be taken when installing any unit including transoms above such large opening units. Loewen is not responsible for site measurements or the determination of structural and architectural requirements for the installation of large opening products such as but not limited to, Liftslide, Bifold and MultiSlide doors. Site specifications are the responsibility of building professionals or engineers to determine. M12 Technical Guide

Multislide Narrow Stile - Bi-Parting With Pocket 3 [2623] 145 [99] 151 [3839] 217 7/16 [5523] 283 3/4 [7207] 289 [7341] 247 [6279] 289 [7341] System 2 [2597] 144 [73] 150 [38] 216 7/16 [5497] 282 3/4 [7182] 288 [7315] 246 [6253] 288 [7315] Framed 53 [52] 95 [2428] 77 [19] 143 7/16 [44] 209 3/4 [5328] 227 [5772] 125 [3180] 191 [4856] R.O 24 [6] 24 [6 29 [759] 47 [1217] Pocket 4 7 [178] 4 ] 7 [178] [254] [330] 4 7 [178] 39 [994] 38 [981] - X- X 63 [14] 62 [1591] - X- X 87 [2214] 99 [2518] 86 11/16 [2201] 98 [2505] 84 [24] 96 [2438] - - X- X X- X 111 [2823] 1 [28] 8 [2743] - X- X 123 [3128] 122 [3115] 120 [3048] - X- X Minimum Dimensions - 2' x 3' Minimum Dimensions - 5 x Maximum System - 24' Note: The preparation of the rough opening for large openings such as those required by, but not limited to, LiftSlide, Bifold and MultiSlide doors have unique requirements. Structural headers that allow for deflection no greater than along the unsupported length once the header is fully loaded are required. Special care needs to be taken when installing any unit including transoms above such large opening units. Loewen is not responsible for site measurements or the determination of structural and architectural requirements for the installation of large opening products such as but not limited to, LiftSlide, Bifold and MultiSlide doors. Site specifications are the responsibility of building professionals or engineers to determine. Technical Guide M

Multislide Wide Stile - Bi-Parting With Pocket 3 [2623] 142 [99] 151 [3839] 214 [5445] 277 [7041] 289 [7341] 247 [6279] 289 [7341] System 2 [2597] 141 [3595] 150 [38] 2 [5419] 276 [7015] 288 [7315] 246 [6253] 288 [7315] Framed 53 [52] 91 3/4 [2330] 77 [19] 9 [3546] 203 [5162] 225 [5725] 125 [3180] 189 [48] R.O 24 [6] 24 [6] 30 [782] 48 7/16 [1230] Pocket 4 7 [178] 4 7 [178] [254] [330] 4 7 [178] 39 [994] 38 [981] - X- X 63 [14] 62 [1591] - X- X 87 [2214] 99 [2518] 86 11/16 [2201] 98 [2505] 84 [24] 96 [2438] - - X- X X- X 111 [2823] 1 [28] 8 [2743] - X- X 123 [3128] 122 [3115] 120 [3048] - X- X Minimum Dimensions - 2' x 3' Minimum Dimensions - 5 x Maximum System - 24' Note: The preparation of the rough opening for large openings such as those required by, but not limited to, LiftSlide, Bifold and MultiSlide doors have unique requirements. Structural headers that allow for deflection no greater than along the unsupported length once the header is fully loaded are required. Special care needs to be taken when installing any unit including transoms above such large opening units. Loewen is not responsible for site measurements or the determination of structural and architectural requirements for the installation of large opening products such as but not limited to, LiftSlide, Bifold and MultiSlide doors. Site specifications are the responsibility of building professionals or engineers to determine. M14 Technical Guide

Multislide Bi-Parting Door Detail Head & Sill Detail Glazing Stop Options Double Triple METAL CLAD - NARROW STILE () METAL CLAD - WIDE STILE () Plan View METAL CLAD - NARROW STILE () METAL CLAD - WIDE STILE () Note: Drawings shown are typical details. Additional sizes and configurations available. Screen options may be available depending on size and configuration. All dimensions to have +/- 1/16" (2 mm) tolerance. The preparation of the rough opening for large openings such as those required by, but not limited to, LiftSlide, Bifold and MultiSlide doors have unique requirements. Structural headers that allow for deflection no greater than along the unsupported length once the header is fully loaded are required. Special care needs to be taken when installing any unit including transoms above such large opening units. Loewen is not responsible for site measurements or the determination of structural and architectural requirements for the installation of large opening products such as but not limited to, Liftslide, Bifold and MultiSlide doors. Site specifications are the responsibility of building professionals or engineers to determine. Technical Guide M15