Nanoscale Imaging with Extreme Ultraviolet Lasers

Similar documents
k λ NA Resolution of optical systems depends on the wavelength visible light λ = 500 nm Extreme ultra-violet and soft x-ray light λ = 1-50 nm

Reflection mode imaging with nanoscale resolution using a compact extreme ultraviolet laser

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

Diffractive optical elements based on Fourier optical techniques: a new class of optics for extreme ultraviolet and soft x-ray wavelengths

Water-Window Microscope Based on Nitrogen Plasma Capillary Discharge Source

Analysis of extreme ultraviolet microscopy images of patterned nanostructures based on a correlation method

Sub 400 nm spatial resolution extreme ultraviolet holography with a table top laser

Talbot lithography: Self-imaging of complex structures

Discovering Electrical & Computer Engineering. Carmen S. Menoni Professor Week 3 armain.

Applications of Optics

EUV and Soft X-Ray Optics

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004

On-line spectrometer for FEL radiation at

Major Fabrication Steps in MOS Process Flow

Exam 4. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question.

PHY 431 Homework Set #5 Due Nov. 20 at the start of class

Zoneplate lenses for EUV microscopy. EUVL workshop 2009 Iacopo Mochi, Kenneth A. Goldberg, Erik H. Anderson, Sungmin Huh

Lensless diffractive imaging using tabletop, coherent, high harmonic soft x- ray beams

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

Confocal Microscopy and Related Techniques

EUVL Activities in China. Xiangzhao Wang Shanghai Inst. Of Opt. and Fine Mech. Of CAS. (SIOM) Shanghai, China.

SUPPLEMENTARY INFORMATION

Low Voltage Electron Microscope

Development of a fast EUV movie camera for Caltech spheromak jet experiments

EUV Plasma Source with IR Power Recycling

Exam 3--PHYS 102--S10

Sub-50 nm period patterns with EUV interference lithography

Practice Problems for Chapter 25-26

Chapter 25. Optical Instruments

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Mechanical Engineering Department. 2.71/2.710 Final Exam. May 21, Duration: 3 hours (9 am-12 noon)

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

OPTICS DIVISION B. School/#: Names:

Chapter 17: Wave Optics. What is Light? The Models of Light 1/11/13

Zone-plate-array lithography using synchrotron radiation

Recent Activities of the Actinic Mask Inspection using the EUV microscope at Center for EUVL

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

INTRODUCTION THIN LENSES. Introduction. given by the paraxial refraction equation derived last lecture: Thin lenses (19.1) = 1. Double-lens systems

PHYSICS. Chapter 35 Lecture FOR SCIENTISTS AND ENGINEERS A STRATEGIC APPROACH 4/E RANDALL D. KNIGHT

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

Resolution Characterization and Nanofabrication for Soft X-ray Zone Plate Microscopy. Weilun Chao

LOS 1 LASER OPTICS SET

PHYS 202 OUTLINE FOR PART III LIGHT & OPTICS

Tabletop coherent diffractive microscopy with extreme ultraviolet light from high harmonic generation

FULL-FIELD microscopes are the most versatile and widely

Section 2: Lithography. Jaeger Chapter 2 Litho Reader. The lithographic process

MICROCHIP MANUFACTURING by S. Wolf

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

Section 2: Lithography. Jaeger Chapter 2 Litho Reader. EE143 Ali Javey Slide 5-1

A novel High Average Power High Brightness Soft X-ray Source using a Thin Disk Laser System for optimized Laser Produced Plasma Generation

Low Voltage Electron Microscope. Nanoscale from your benchtop LVEM5. Delong America

Digital Camera Technologies for Scientific Bio-Imaging. Part 2: Sampling and Signal

Chapter Ray and Wave Optics

Testing Aspheric Lenses: New Approaches

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

Random lasing in an Anderson localizing optical fiber

Design and Fabrication of an Efficient Extreme Ultraviolet Beam Splitter

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Introduction of New Products

Diffraction, Fourier Optics and Imaging

2. Pulsed Acoustic Microscopy and Picosecond Ultrasonics

Light Microscopy. Upon completion of this lecture, the student should be able to:

EUV Interference Lithography in NewSUBARU

Chapter 18 Optical Elements

Chapter 36: diffraction

Flatness of Dichroic Beamsplitters Affects Focus and Image Quality

Sensitive measurement of partial coherence using a pinhole array

Fabrication of Probes for High Resolution Optical Microscopy

Numerical analysis to verifying the performance of condenser magnetic lens in the scanning electron microscope.

Nanopatterning in a compact setup using table top extreme ultraviolet lasers

Fiber-optic Michelson Interferometer Sensor Fabricated by Femtosecond Lasers

NIST EUVL Metrology Programs

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

Microscopy Techniques that make it easy to see things this small.

Reflectors vs. Refractors

Section 2: Lithography. Jaeger Chapter 2. EE143 Ali Javey Slide 5-1

Bridging the Gap Between Tools & Applications

Computer Generated Holograms for Optical Testing

Compact EUV Source for Metrology and Inspection

EE119 Introduction to Optical Engineering Spring 2002 Final Exam. Name:

Diffraction. Interference with more than 2 beams. Diffraction gratings. Diffraction by an aperture. Diffraction of a laser beam

:... resolution is about 1.4 μm, assumed an excitation wavelength of 633 nm and a numerical aperture of 0.65 at 633 nm.

Vision 1. Physical Properties of Light. Overview of Topics. Light, Optics, & The Eye Chaudhuri, Chapter 8

Single-photon excitation of morphology dependent resonance

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.

Vertical External Cavity Surface Emitting Laser

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

Study of self-interference incoherent digital holography for the application of retinal imaging

Product Information Version 1.0. ZEISS Xradia 810 Ultra Nanoscale X-ray Imaging at the Speed of Science

Laser Speckle Reducer LSR-3000 Series

Printing Beyond srgb Color Gamut by. Mimicking Silicon Nanostructures in Free-Space

Effects of spherical aberrations on micro welding of glass using ultra short laser pulses

Laser Beam Analysis Using Image Processing

plasmonic nanoblock pair

S200 Course LECTURE 1 TEM

Improving the Collection Efficiency of Raman Scattering

Vision. The eye. Image formation. Eye defects & corrective lenses. Visual acuity. Colour vision. Lecture 3.5

Laser-Produced Sn-plasma for Highvolume Manufacturing EUV Lithography

Pulse Shaping Application Note

Transcription:

Nanoscale Imaging with Extreme Ultraviolet Lasers C. Brewer *, G. Vaschenko, F. Brizuela, M. Grisham, Y. Wang, M. A. Larotonda, B. M. Luther, C. S. Menoni, M. Marconi, and J. J. Rocca. NSF ERC for Extreme Ultraviolet Science and Technology and Department of Electrical and Computer Engineering, Colorado State University, Fort Collins, CO, 80523 and W. L. Chao, J. A. Liddle, E. H. Anderson, and D. T. Attwood NSF ERC for Extreme Ultraviolet Science and Technology and Center for X-ray Optics, Lawrence Berkeley National Laboratory and University of California, Berkeley, CA A tabletop, extreme ultraviolet (EUV) imaging system with nanometer-scale resolution has been developed. This system is based on a very compact capillary-discharge Ne-like Ar laser emitting in the EUV part of the spectrum at a wavelength of 46.9 nm. Imaging was demonstrated in both transmission and reflection modes to obtain a spatial resolution better than 140 nm. This is the best resolution obtained with a compact coherent source to date. These results, which are scalable to shorter wavelengths and higher resolution, foretell the feasibility of compact imaging tools to further developments in nanoscience and nanotechnology. Abilities of this microscope, such as investigating structural materials on nanoscales, aiding in the lithographic process of the next-generation of integrated circuits with nanoscale feature sizes, and seeing nanofeatures of miniature systems as they are designed, will allow spacecraft and space exploration techniques to reach a previously unsurpassed level. k λ NA r Nomenclature = a constant that is dependent on the coherence of the illumination source and quality of the optics = wavelength of the illumination source = numerical aperture of the objective = outer zone width of a zone plate I. Introduction ANOTECHNOLOGY carries the undeniable promise to lead to previously unimaginable possibilities and N discoveries in science and technology. According to NASA s Center for Nanotechnology Nanotechnology is the creation of functional materials, devices and systems through control of matter on the nanometer length scale (1-100 nanometers), and exploitation of novel phenomena and properties (physical, chemical, biological, mechanical, electrical...) at that length scale (http://www.ipt.arc.nasa.gov/). As the science and technology take a journey into the nano-world, possibilities such as integrated circuits reaching feature sizes smaller than 100 nm, nanostructures being developed, and material properties on the nanometer length scale being discovered and manipulated, will be achievable. This nanoscience and nanotechnology revolution opens a myriad of opportunities for spacecraft design and space exploration techniques. As nanotechnology rapidly progresses, compact, fast, and practical tools that allow us to see nanometer-scale features are highly desired. Several high-resolution imaging techniques currently exist, such as electron microscopy and various scanning probe techniques. An alternative method, optical microscopy, is advantageous to the other techniques in that the investigated sample requires little preparation, images are rendered rapidly, and the sample s environment can be varied. (e.g., by varying the electromagnetic field to study the reactions of a material or * Student Research Assistant, Department of Electrical and Computer Engineering, brewerca@holly.colostate.edu. Colorado Space Grant Consortium 1

biological specimen). Unfortunately conventional visible light microscopes are limited in resolution. The spatial resolution capability of a light microscope is given by the Rayleigh criterion, k λ Spatial resolution =, (1) NA where λ is the wavelength of the illumination source, NA is the numerical aperture of the objective, and k is a constant that is determined by the objective s aberrations and coherence of the source. 1,2 For an aberration free objective and incoherent illumination, k = 0.61. Spatial resolution is therefore limited to ~200 nm at best with a visible light source (λ= 400 nm). The ability to resolve 100-nm scale features can thus be achieved by using shorter wavelength extreme ultraviolet (EUV) or even soft-x-ray sources. The best resolution thus far, 20 nm, was obtained using 2.07 nm wavelength synchrotron radiation in transmission mode. 2 This imaging system has been used to obtain spectacular images of biological cells, magnetic structures, and other objects with impressive quality and detail. 3-5 Unfortunately the very small number and extremely high demand of synchrotron sources limits the widespread use of this powerful technology. We have developed a more compact and practical high-resolution imaging system with a tabletop capillarydischarge pumped EUV laser source, which is only a small fraction of the size of a synchrotron. This system can be potentially used for imaging in nanotechnology applications and can be accommodated in a small-scale university lab or in an industrial setting, thus enabling much wider use of the nanoscale optical imaging. Unlike other existing EUV installations our microscope can operate not only in transmission mode, but also in the more challenging reflection mode. Due to low reflectivity of materials in the EUV part of the spectrum only one proof-of-principle experiment on the reflection mode imaging has previously been published. 6 Our microscope is capable of this feature due to the high brightness of the source. This functional imaging system has successfully resolved features smaller than 140 nm. 7,8 which is the highest resolution obtained to date using a compact coherent source. The resolution can be further improved beyond 100 nm by using the readily available higher resolution optics and shorter wavelength laser light. Objective zone plate 46.9 nm laser Schwarzschild condenser Test pattern CCD Figure 1. A schematic representation of the 46.9 nm compact extreme ultraviolet imaging system set up in transmission mode. Colorado Space Grant Consortium 2

II. Imaging System Setup The high resolution microscope configured for transmission mode of operation is schematically depicted in Fig. 1. It consists of a compact EUV laser followed by a reflective Schwarzschild condenser, which focuses the light onto the sample. A diffractive zone plate objective then forms a magnified image of the sample onto an EUVsensitive CCD detector. To implement the reflection mode of imaging the sample is turned at 45 with respect to the beam, whereas the objective and the CCD are placed in the reflected beam at 90. The condenser, sample, and objective are all mounted on motorized translation stages and assembled in a vacuum chamber that is typically maintained at a pressure of ~10-5 torr. A. Laser Source A very compact capillary-discharge Ne-like Ar laser that emits radiation at a wavelength of 46.9 nm was used as the illumination source (Fig. 2). 9 This laser that was recently developed at Colorado State University is the brightest source of coherent EUV light available today, with the average output power exceeding 3 mw. Lasing is obtained here by exciting a plasma column in a ceramic capillary with a fast 200 ka current pulse. The length of the capillary determines the laser output pulse energy and degree of spatial coherence. In this experiment a relatively short 18 cm capillary was used, providing a pulse energy of ~ 100 µj. This choice of capillary length ensured a sufficient photon flux while keeping the spatial coherence of the laser beam relatively low to avoid diffraction fringes and speckle in the images. The laser pulses have duration of ~1.2 ns and a repetition rate of 1 Hz. This laser is well-suited for high resolution microscopy due to its short wavelength, high photon flux, narrow spectral bandwidth, and controllable spatial coherence. Microscope 46.9 nm Laser Figure 2. A picture of the 46.9 nm imaging system with the tabletop capillary-discharge Ne-like Ar laser (right) and the microscope chamber (left). B. Condenser One of the specific features of the EUV spectral range is that even a thinnest layer of any material absorbs most of the EUV radiation. Therefore the conventional refractive lenses can not be used at EUV. Instead, only reflective, such as multilayer coated mirror, or diffractive, such as zone plate, optics can be used in the design of a microscope. A Sc/Si multilayer coated Schwarzschild objective was developed in this work to condense the light onto the sample. This Schwarzschild contains a primary convex mirror of 10.8 mm in diameter and a 50 mm secondary concave mirror. Together these two mirrors produce a hollow cone of 46.9 nm light that is focused onto the sample, which is placed ~2.5 cm from the output of the condenser. The Schwarzschild condenser has a numerical aperture (NA) of 0.18 and a throughput of only ~1%. This low throughput could be improved by at least one order of magnitude by using the best available Sc/Si multilayer coatings with ~40 % reflectivity at this wavelength. 10 C. Objective A diffractive zone plate was used as an objective. A zone plate consists of alternating opaque and transparent concentric rings (Fig. 3). 11 When the radiation skims the edges of the opaque regions it bends, or diffracts, at an angle that is directly proportional to the wavelength of the illumination and indirectly proportional to the zone width. Thus the smaller the zone width, the more the light bends. The radius of each of these rings is chosen such that the diffracted radiation has the same phase for constructive interference, and is directed towards a focal point. To achieve this, the radius of each subsequent transparent zone must have an optical path length difference towards the Colorado Space Grant Consortium 3

focal point of one wavelength. A zone plate is advantageous due to its high spatial resolution capability and small size. The spatial resolution of a zone plate can be estimated as: Spatial resolution 2 k r, (2) where r is the width of the outermost zone and k has the same meaning as in Eq. 1. The zone plate for this microscope was manufactured at Lawrence Berkeley National Laboratory using electron beam lithography in a thin nickel foil. Normally zone plates designed for shorter wavelength are supported by a very thin (~100 nm) silicon nitride (Si 3 N 4 ) substrate. Because 46.9 nm radiation is rapidly absorbed by most materials, the zone plate for our imaging system was fabricated to be freestanding to maximize throughput. This was accomplished by adding random pseudo support structures connecting the rings and then etching out the substrate. Fig.4 is a computer aided design (CAD) image of a freestanding zone plate. It has an outer zone width of 200 nm, a diameter of 0.5 mm, a focal distance of 2.13 mm, and a numerical aperture of 0.12. The reason a zone plate was not used as the condenser instead of the Schwarzschild objective, which is large and has a throughput of only ~1%, is that it was impossible to manufacture a sturdy freestanding zone plate large enough to encompass the beam diameter at the condenser position, which was approximately 10 mm. Figure 3. An illustration of a diffractive zone plate. (from Ref. 11) Figure. 4. A CAD image of a freestanding zone plate with pseudo-random support structures connecting the zones. D. CCD Detector The images were collected on an EUV-sensitive CCD camera with a back-illuminated 1024 x 1024 array of 24 µm x 24 µm pixels. During the experiment the camera was thermoelectrically cooled to improve the signal-to-noise ratio. Typical distances between the zone plate and CCD were in the range from 0.5-1.60 m corresponding to magnifications between 250x-750x. III. Results To investigate the capabilities of the new imaging system we have tested it with a few samples with nanometerscale features. The first sample imaged was a specially designed test pattern containing concentric apertures as small as 100 nm. It was fabricated using electron beam lithography onto a nickel foil. Fig. 5(a) is an image of the test pattern acquired in transmission mode with a magnification of 470x. The illuminating beam was focused to a 20-30 µm diameter spot on the sample, and the laser was shot 10 times at a 1 Hz repetition rate, resulting in an exposure time of 10 s. An image obtained with the microscope set up in the reflection mode configuration at a magnification of 480x is shown in Fig. 5(b). To ensure complete illumination of the sample and reduce coherence effects in the image, the condenser was slightly defocused and its position was continuously scanned during the acquisition of 70 laser shots. Because the beam is not at normal incidence with respect to the sample, and the zone plate has a narrow focal depth of ~3.5 µm, only the central vertical portion of the image is well defined. The smallest 100 nm apertures in the inner circle are visible in both images. To illustrate one of the applications of reflection mode imaging, the second sample imaged in reflection mode was chosen to be a silicon wafer chip with patterned polysilicon lines. This chip was manufactured in an effort Colorado Space Grant Consortium 4

(a) 100 nm (b) 10 µm 10 µm Figure 5. Images of a sample test pattern obtained with a compact 46.9 nm wavelength microscope in (a) transmission mode with a 10 second exposure time, and in (b) reflection mode with a slighlty longer exposure time of 70 seconds to compensate for the low reflectivity of the Ni test pattern. The inner circle apertures are 100 nm wide. aimed towards optimizing the lithography process for chip manufacturing. Fig. 6 is an EUV image of the silicon sample acquired using 20 laser shots with a 480x magnification. In the upper right corner of the image, 100 nm polysilicon lines spaced by 800 nm are discernible. However, the line-width appears larger than 1/8 the value of the spaces, which is an indication that the 100 nm finest lines are narrower than the resolution limit of this system. In the lower right region of the image, 250 nm lines and spaces are well resolved. To determine the spatial resolution of the 46.9 nm wavelength microscope, an extra freestanding zone plate was imaged in transmission mode. Images were acquired at a magnification of 250x for the larger periodic circles toward the center of the zone plate (Fig. 7(a)), while a magnification of 750x was chosen for the smaller zones of 200 nm near the edge of the zone plate (Fig. 7(b)). Periodic structures are often used to determine the spatial resolution of a microscope. Here the size of the periodic zones at which the peak intensity modulation is reduced to 26.5%, according to the Rayleigh criterion, is the resolution of the microscope. 1 In these images, the intensity distribution of the smallest 200 nm zones at the edge of the zone plate still had a modulation depth of more than 90%. In the absence of a finer periodic structure a different, the knife-edge resolution test, was then applied. This test calculates the distance it takes at the edge of a structure for the intensity to drop from 90% to 10%. To apply this test, we took a typical cross section of the intensity distribution at the edge of the zone plate and found a local resolution of 126 nm, illustrated in Fig. 7(c). 100 nm lines/ 800 nm spaces 2 µm 250 nm lines/ 250 nm spaces Figure 6. A reflection mode image of a silicon wafer chip acquired in 20 seconds at a magnification of 480x. The lines in the upper right corner are 100 nm wide spaced apart by 800 nm, and in the lower right corner are 250 nm wide lines and spaces. Colorado Space Grant Consortium 5

Averaging together 25 different areas along the edge of the zone plate, the spatial resolution of the system was realized to be 137 + 15 nm. This is the best resolution ever obtained with a compact coherent illumination source. Referring to Eq. (1) for determining the resolution limit of a light microscope and plugging in λ= 46.9 nm for the illumination source wavelength, NA= 0.12 for the numerical aperture of the imaging zone plate, and k= 0.61 for the constant of an aberration-free zone plate and an incoherent illumination source, the estimated spatial resolution capability of our microscope is 238 nm. However, the experimentally determined resolution of this system was 137 ± 15 nm, which corresponds to k= 0.35. This low value for k is a result of partially coherent illumination of the sample and low aberrations in the imaging zone plate. 7 1 µm Intensity, a.u. 140 120 100 80 60 40 (b) 90 % 126 nm 20 10 % 0 0.0 0.5 1.0 1.5 2.0 Distance, µm Figure 7 (a) A tranmission mode image at the edge of a freestanding zone plate with 200 nm outermost zones. It was obtained using the 46.9 nm wavelength microscope in transmission mode with 10 laser shots at a magnification of 750x. (b) A sampled crossection of the intensity distribution at the edge of the zone plate s image. According to the knife-edge test, the 10-90% tansition local resolution is 126 nm. An average of 25 different areas along the edge of the zone plate resulted in a resolution of 137 + 15 nm. IV. Current Work According to Eq. (1), the most direct way to improve spatial resolution of an imaging system is to use a shorter wavelength illumination source. Recently a small-scale laser-pumped Ni-like Ag laser with an output wavelength of 13.9 nm was developed at CSU (Fig. 8). 12 This novel source produces very short pulses of light at 13.9 nm Figure 8. A picture of the recently-developed, small-scale, laser-pumped, Ni-like Ag laser with an output wavelength of 13.9 nm. Colorado Space Grant Consortium 6

wavelength as a result of ionization and heating silver plasma with high energy pulses from an infrared laser. We are currently developing a new imaging system that would work with this laser and that would have a sub-100 nm spatial resolution. The new imaging system is similar to the 46.9 nm wavelength system in Fig. 1. One difference is that because silicon nitride is not as absorbant at a wavelength of 13.9 nm, it is unnecessary for the zone plates to be freestanding. This combined with the fact that the 13.9 nm beam is smaller at the location of condenser allowing for a smaller condenser, makes it possible to manufacture sturdy zone plates for both the objective and condenser. A star test pattern consisting of converging thin nickel lines supported by a Si 3 N 4 substrate has been imaged in a preliminary experiment. Fig. 9 is an image of this pattern acquired with an exposure time as short as 20 seconds. The central part of the pattern shows lines of about 80 nm. This first imaging result demonstrates the feasibility of imaging with this newly developed EUV laser, and indicates the ability of this instrument to resolve feature sizes below 80 nm. 1 µm Figure 9. An image of a set of radial spokes obatined using 13.9 nm wavelength illumination with a 20 second exposure. The lines visible in the center of the pattern are ~80 nm wide. V. Conclusion In conclusion, we have achieved high resolution, real-time imaging in both transmission mode and the more challenging reflection mode by exploiting the high photon flux and high repetition rate of a capillary-discharge EUV laser emitting radiation at the short wavelength of 46.9 nm. The imaging system employs a Schwarzschild condenser, zone plate objective, and a CCD detector to resolve feature sizes as small as 137 + 15 nm. This result is impressive, as it is the best resolution ever obtained using a compact coherent EUV source. To achieve even better resolution, we are currently developing an imaging system that relies on the recently demonstrated 13.9 nm laser. By using an illumination source with a wavelength less than 1/3 of the 46.9 nm wavelength source, we expect to achieve a spatial resolution significantly better than 80 nm. Our future goals are to improve the performance of the imaging system using a better understanding of coherence effects, using zone plates with smaller outer zone widths, and moving to shorter wavelengths as compact sources are developed. We also plan to further scale down the size of the imaging system, thus making it more attractive for practical applications. These efforts are significant, as they will pave the way to realize a high-resolution, real-time, compact imaging tools for many applications. By investigating nanoscale properties of materials and systems, inspecting lithographic masks to produce integrated circuits with nanoscale feature sizes, and overall aiding in the development of nanoscience and nanotechnology, these instruments will serve as an important aide in advancing the space exploration and spacecraft design. Colorado Space Grant Consortium 7

Acknowledgments C. Brewer thanks the Colorado Space Grant Summer Internship, the summer REU program at the Extreme Ultraviolet Engineering Research Center, and the Student Leaders of Engineering for their financial support. This work was also supported by the Engineering Research Centers Program of the National Science Foundation under NSF Award Number EEC-0310717. We extend our gratitude to AMD for providing the wafer samples, the W.M. Keck Foundation, and the US Civilian Research and Development Foundation (CRDF). References 1 Born, M., and Wolf, E., Principles of Optics, Cambridge University, New York, 1999, pp.461-472, 595-606. 2 Chao, W., Anderson, E., Denbeaux, G.P., Harteneck, B., Liddle, J.A., Olynick, D.L., Pearson, A.L., Salmassi, F., Song, C.Y., and Attwood, D.T., 20-nm-resolution soft x-ray microscopy demonstrated by use of multilayer test structures, Opt. Lett., Vol. 28, 2003, pp. 2019-2021. 3 Denbeaux, G., Fischer, P., Kusinski, G., Le Gros, M., Pearson, A., Attwood, D.T., A full field transmission X-ray microscope as a tool for high-resolution magnetic imaging, IEEE Trans. on Magnetics, Vol. 37, 2001, pp. 2764. 4 Magowan, C., Brown, J.T., Liang, J., Heck, J., Coppel, R.L., Mohandas, N., Meyer-Ilse, W., Intracellular structures of normal and aberrant Plasmodium falciparum malaria parasites imaged by soft x-ray microscopy, Proc. Nat. Acad. Sci. USA, Vol. 94, 1997, pp. 6222. 5 Schneider, G., Denbeaux, G., Anderson, E., Bates, W., Salmassi, F., Nachimuthu, P., Pearson, A., Richardson, D., Hambach, D., Hoffman, N., Hasse, W., and Hoffman, K., Electromigration in integrated circuit interconnects studied by X-ray microscopy, Nucl. Inst. And Meth. In Phys. Res., Vol. B199, No. 2, 2003, pp. 469. 6 DiCicco, D.S., Kim, D., Rosser, R., and Suckewer, S., First stage in the development of a soft-x-ray reflection imaging microscope in the Schwarzschild configuration using a soft-x-ray laser at 18.2 nm, Opt. Lett., Vol. 17, 1992, pp. 157-159. 7 Vaschenko, G., Brizuela, F., Brewer, C., Grisham, M., Mancini, H., Menoni, C.S., Marconi, M.C., and Rocca, J.J., Nanoimaging with a compact extreme ultraviolet laser, Opt. Lett., 2004, (to be published). 8 Brizuela, F., Vaschenko, G., Brewer, C., Grisham, M., Menoni, C.S., Marconi, M.C., and Rocca, J.J., Reflection mode imaging with nanoscale resolution using a compact extreme ultraviolet laser, Opt. Express, 2005, (to be published). 9 Benware, B.R., Macchietto, C.D., Moreno, C.H., and Rocca, J.J., Demonstration of a high average power tabletop soft x- ray laser, Phys. Rev.Lett., Vol. 81, 1998, pp. 5804-5807. 10 Uspenskii, Yu. A., Lavashov, V.E., Vinogradov, A.V., Fedorenko, A.I., Kondratenko, V.V., Pershin, Yu. P., Zubarev, E.N., and Fedotov, V. Yu., High-reflectivity multilayer mirrors for a vacuum-ultraviolet interval of 35-50 nm, Opt. Lett., Vol. 23, 1998, pp. 771-773. 11 Attwood, D.T., Soft X-Rays and Extreme Ultraviolet Radiation, Cambridge University, New York, 1999, Chap. 9. 12 Wang, Y., Larotonda, M.A., Luther, B.M., Alessi, D., Berrill, M., Shlyaptsev, V.N., and Rocca, J.J., Demonstration of saturated high repetition rate tabletop soft x-ray lasers at wavelengths down to 13.9 nm, Phys. Rev. Lett., 2004, (to be published). Colorado Space Grant Consortium 8