Spec Information. Reactances Per Unit Ohms

Similar documents
GENERATOR DATA JANUARY 30, 2015

Spec Information. Reactances Per Unit Ohms

S0L1-J1 - Technical Data Sheet

S4L1D-G41 Wdg Technical Data Sheet

S4L1S-D4 Wdg.17 - Technical Data Sheet

440 (12) 416 (12) 416 (12) 440 (12)

PARTNER ALTERNATORS LSA 40-4 Pole

Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

WDG 12 - Technical Data Sheet

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

WDG 71 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 61 - Technical Data Sheet

WDG 13 - Technical Data Sheet

WDG 07 - Technical Data Sheet

WDG 51 - Technical Data Sheet

TAL 044 Low Voltage Alternator - 4 pole

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 83 - Technical Data Sheet

TAL 049 Low Voltage Alternator - 4 pole

PI734C - Technical Data Sheet

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

TAL 047 Low Voltage Alternator - 4 pole

PI734A - Technical Data Sheet

Generator Advanced Concepts

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

Low Voltage alternators - 4 pole LSA 47.2

PM734B - Technical Data Sheet. Generator Solutions AS

Low Voltage alternators - 4 pole LSA 46.2

LSA Pole. R 726 Mains paralleling

PARTNER ALTERNATORS LSA Pole

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW

STEADY STATE REACTANCE

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

AGN 034 Alternator Reactance

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PART 1 OWNER/APPLICANT INFORMATION

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

Packaged Generators: New Kato Engineering Packaged Generator Line: Over 75 Years of Experience: Conformity: Service: Quality Standards:

Owner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

Class 300 Equipment CBS 305, 320 Current Boost Systems FEATURES. DESCRIPTION Page 2. SPECIFICATIONS Pages 2 through 4.

Code No: R Set No. 1

Technical Data Sheet for AvK-Alternators

SYNCHRONOUS MACHINES

Technical Data Sheet for AvK-Alternators

Introduction : Design detailed: DC Machines Calculation of Armature main Dimensions and flux for pole. Design of Armature Winding & Core.

Technical Data Sheet for AvK-Alternators

Initial Application Form for Connection of Distributed Generation (>10kW)

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

Technical Data Sheet for AvK-Alternators

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

APPENDIX B: Generation Interconnection Application Form

APPLICATION FOR INTERCONNECTION & OPERATIONS OF MEMBER-OWNED GENERATION

OPERATING, METERING, AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 2,000 KILOWATTS

Sizing Generators for Leading Power Factor

AGN 005 Fault Currents and Short Circuit Decrement Curves

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

Electrical Machines (EE-343) For TE (ELECTRICAL)

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

Conventional Paper-II-2013


Application Guidance Notes: Technical Information from Cummins Generator Technologies

Synchronous Generators II EE 340

PAPER-II (Subjective)

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

Overview of IAL Software Programs for the Calculation of Electrical Drive Systems

CERTIFICATES OF COMPETENCY IN THE MERCHANT NAVY MARINE ENGINEER OFFICER

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

VALLIAMMAI ENGINEERING COLLEGE

Synchronous Generator Subtransient Reactance Prediction Using Transient Circuit Coupled Electromagnetic Analyses & Odd Periodic Symmetry

Dhanalakshmi Srinivasan Institute of Technology, Samayapuram, Trichy. Cycle 2 EE6512 Electrical Machines II Lab Manual

HCM634G - Technical Data Sheet

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Type KLF Generator Field Protection-Loss of Field Relay

TABLE OF CONTENT

System Protection and Control Subcommittee

Placement Paper For Electrical

Generation Interconnection Study Data Sheet Synchronous Machines

Conventional Paper-II-2011 Part-1A

Motor Protection. May 31, Tom Ernst GE Grid Solutions

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

CERTIFICATES OF COMPETENCY IN THE MERCHANT NAVY MARINE ENGINEER OFFICER

R10. III B.Tech. II Semester Supplementary Examinations, January POWER SYSTEM ANALYSIS (Electrical and Electronics Engineering) Time: 3 Hours

Impact Assessment Generator Form

Transcription:

GENERATOR DATA Spec Information Generator Specification Frame: 1647 Type: SR5 No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel: 21.0 Connection: SERIES STAR Housing: 00 Phases: 3 No. of Leads: 6 Poles: 4 Wires per Lead: 4 Sync Speed: 1500 Generator Pitch: 0.6667 Generator Efficiency Per Unit Load kw Efficiency % 0.25 400.0 93.5 0.5 800.0 95.7 0.75 1200.0 96.0 1.0 1600.0 95.9 1.1 1760.0 95.8 Reactances Per Unit Ohms SUBTRANSIENT - DIRECT AXIS X'' d 0.1150 0.0092 SUBTRANSIENT - QUADRATURE AXIS X'' q 0.1438 0.0115 TRANSIENT - SATURATED X' d 0.2213 0.0177 SYNCHRONOUS - DIRECT AXIS X d 2.9750 0.2380 SYNCHRONOUS - QUADRATURE AXIS X q 1.7850 0.1428 NEGATIVE SEQUENCE X 2 0.1300 0.0104 ZERO SEQUENCE X 0 0.0275 0.0022 Time Constants Seconds OPEN CIRCUIT TRANSIENT - DIRECT AXIS T' d0 2.9100 SHORT CIRCUIT TRANSIENT - DIRECT AXIS T' d 0.2540 OPEN CIRCUIT SUBSTRANSIENT - DIRECT AXIS T'' d0 0.0460 SHORT CIRCUIT SUBSTRANSIENT - DIRECT AXIS T'' d 0.0240 OPEN CIRCUIT SUBSTRANSIENT - QUADRATURE AXIS T'' q0 0.2320 SHORT CIRCUIT SUBSTRANSIENT - QUADRATURE AXIS T'' q 0.0220 EXCITER TIME CONSTANT T e 0.0940 ARMATURE SHORT CIRCUIT T a 0.0450 Short Circuit Ratio: 0.42 Stator Resistance = 0.0013 Ohms Field Resistance = 0.5 Ohms Voltage Regulation Voltage level adustment: +/- Voltage regulation, steady state: +/- 5.0 % 0.5 % Voltage regulation with 3% speed change: +/- 0.5 % Waveform deviation line - line, no load: less 2.0 Excitation voltage: Excitation current Generator Excitation No Load Full Load, (rated) pf Series Parallel 12.0 Volts 46.86 Volts Volts 1.2 Amps 3.85 Amps Amps

than % Telephone influence factor: less than 50

Generator Mechanical Information Center of Gravity Dimension X -786.0 mm -30.9 IN. Dimension Y 0.0 mm Dimension Z 0.0 mm 0.0 IN. 0.0 IN. "X" is measured from driven end of generator and parallel to rotor. Towards engine fan is positive. See General Information for details "Y" is measured vertically from rotor center line. Up is positive. "Z" is measured to left and right of rotor center line. To the right is positive. Generator WT = 3945 kg * Rotor WT = 1644 kg * Stator WT = 2380 kg 8,697 LB 3,624 LB 5,247 LB Rotor Balance = 0.0508 mm deflection PTP Overspeed Capacity = 150% of synchronous speed Generator Torsional Data J1 = Coupling and Fan K1 = Shaft Stiffness between J1 + J2 (Diameter 1) J2 = Rotor TOTAL J = J1 + J2 + J3 K2 = Shaft Stiffness between J2 + J3 (Diameter 2) J3 = Exciter End J1 K1 Min Shaft Dia 1 J2 K2 Min Shaft Dia 2 J3 62.4 LB IN. s 2 280.6 MLB IN./rad 8.9 IN. 361.1 LB IN. s 2 137.2 MLB IN./rad 5.5 IN. 8.4 LB IN. s 2 7.05 N m s 2 31.7 MN m/rad 225.0 mm 40.8 N m s 2 15.5 MN m/rad 140.0 mm 0.95 N m s 2 Total J 431.9 LB IN. s 2 48.8 N m s 2

Generator Cooling Requirements - Temperature - Insulation Data Cooling Requirements: Temperature Data: (Ambient 40 0 C) Heat Dissipated: 68.4 kw Stator Rise: 125.0 0 C Air Flow: 150.0 m 3 /min Rotor Rise: 125.0 0 C Insulation Class: H Insulation Reg. as shipped: 100.0 MΩ minimum at 40 0 C Thermal Limits of Generator Frequency: 50 Hz Line to Line Voltage: 400 Volts B BR 80/40 1720.0 kva F BR -105/40 1957.0 kva H BR - 125/40 2150.0 kva F PR - 130/40 2150.0 kva H PR - 150/40 2279.0 kva H PR27-163/27 2365.0 kva

Starting Capability & Decrement Motor Starting Capability (0.4 pf) SKVA Percent Volt Dip 351 2.5 720 5.0 1,110 7.5 1,521 10.0 1,955 12.5 2,415 15.0 2,903 17.5 3,421 20.0 3,973 22.5 4,562 25.0 5,191 27.5 5,865 30.0 6,589 32.5 7,369 35.0 8,211 37.5 9,123 40.0 Decrement Data E Time Cycle Instantaneous 3 Phase Fault : 24993 Amps AMP 0.0 24,993 1.0 17,390 2.0 13,600 3.0 11,547 4.0 10,279 5.0 9,382 7.5 7,792 10.0 6,599 12.5 5,634 15.0 5,636 20.0 6,512 25.0 7,376 30.0 8,136 35.0 8,732 40.0 8,929 45.0 8,964 Instantaneous Line - Line Fault : 20319 Amps Instantaneous Line - Neutral Fault : 31643 Amps

Generator Output Characteristic Curves Open Circuit Curve Field Line - Line Volt 0.0 0 21.2 240 25.0 280 29.3 320 34.5 360 42.2 400 55.7 440 83.0 480 143.1 520 281.3 560 Short Circuit Curve Field Armature 0.0 0 59.1 1,732 68.9 2,021 78.7 2,309 88.6 2,598 98.4 2,887 108.3 3,175 118.1 3,464 128.0 3,753 137.8 4,041

Generator Output Characteristic Curves Zero Power Factor Curve Field Line - Line Volt 98.4 0 122.3 200 126.5 240 131.7 280 139.0 320 151.5 360 176.3 400 230.5 440 354.8 480 645.9 520 Air Gap Curve Field Line - Line Volt 0.0 0 21.0 240 24.5 280 28.0 320 31.5 360 35.0 400 38.5 440 42.0 480 45.5 520 49.0 560

Reactive Capability Curve Click to view Chart

General Information DM7825 Caterpillar SR5 Generators (50 Hz, 60 Hz) Data for 1400, 1600, 1700, 1800 and 1900 frames Caterpillar SR5 generators built by Leroy Somer - USA and Leroy Somer France. Refer to DM7821 for explanation of all generator data in Technical Marketing Information (TMI) except generator efficiency for which the explanation is given below. GENERATOR EFFICIENCY Generator efficiency is the percentage of engine flywheel (or other prime mover) power that is converted into electrical output. The generator efficiency shown is calculated by the summation of all losses method, and is determined in accordance with the IEC Standard 60034. The efficiency considers only the generator. There is no consideration of engine or parasitic losses here.