Universal Controller

Similar documents
Electronic Air / Fuel Ratio Control System

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Differential pressure sensors

Electronic Thermostat TE-1 Version according to EN

Self-learning Room Temperature Controller Receiver

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Outside Temperature Sensors

Room Sensors. for relative humidity and temperature

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Impulse system MPT 700. Manual Edition GB

RS /M MZ SERIES

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

RS /E-EV BLU SERIES

ASZ... Potentiometers. Siemens Building Technologies HVAC Products. ASZxx.7xx or ASZxx.8xx

Non-Spring Return DuraDrive Modulating Actuator

NRT 105: Electronic fan-coil controller, equiflex

Control solutions Biofloor

Overcurrent Protection / 7SJ45

Instruction manual SMART 96-2 / WG-2 ph

Room sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Spring Return DuraDrive Proportional Actuator

Room Temperature Controller

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

Sauter Components

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Type CP-S, CP-C & CP-A Switch mode

Speed and Key Monitor Specifications

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

ASZ... Potentiometers. Building Technologies HVAC Products. ASZxx.3x

INSTAT 868 Radio Frequency Single-Room Controls

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Analogue temperature controllers

R7420B. MicroniK 100 HONEYWELL TEMPERATURE CONTROLLER PRODUCT DATA GENERAL FEATURES

Wireless multizone receiver RDE-MZ6

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

OpenAir Linear actuators GDB/GLB...2 Technical basics. CE1Z4664en Building Technologies

B850 Boiler House Energy Monitor

s Climatix extension module 26 I/Os POL985.00/XXX

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

ABB ph/orp analyzer and probe package

Electromotoric actuators

RS /E-EV BLU SERIES

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

Shaft Absolute Vibration Monitor Specifications

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Instruction manual SMART 96-2 / WG-2 LF

Drive Electronics pq11

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Rotary actuators for ball valves

Power supply CP-D 24/4.2 Primary switch mode power supply

Microprocessor-based Temperature Controller

ELECTRONIC THERMOSTAT: T920

Temperature Input Module for Zone 1 Series 9482/32

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Wireless Room Thermostat Installation and Operation Y6630D1007

Power supply CP-D 24/1.3

Type Nominal voltage (V) Code HSV V

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

TZIF 4. Current-to-Pulse Converter 10/ EN

B850 Boiler House Energy Monitor

Analog amplifier RA. RE Edition: Replaces:

Automation System TROVIS 6400 Industrial Controller TROVIS Mounting and Operating Instructions EB 6497 EN. Electronics from SAMSON

RS /E-EV BLU SERIES

EY-EM 527: Remote I/O module, ecolink527


TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

CAN-IO Custom IO remote module

MANUAL FOR OPERATION AND CALIBRATION MODULATOR SIEMENS RWF 40.

QPM Series Indoor Air Quality Duct Sensors

AC 01.2 HART Technical data Actuator controls

Power supply CP-E 24/0.75

Functional data Factory settings Variable Settings

TLC3-BCR-U Series Thermostat

Electronic Circuit Breaker with reset input ESS20-1..

POINTAX 6000L2 Point Recorder

Actuators SQN7... Siemens Building Technologies HVAC Products. for air dampers and control valves of oil or gas burners

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

ECM3 EARTH CONTINUITY RELAY

KS 40-1 burner Universal Burner Controller

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

COMPACT-LINE. Transmitter for ph-value

Power supply CP-D 12/2.1

XUA1 - AC Voltage and phase balance relay

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Valve amplifier for proportional pressure valves

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

Transcription:

7 863 Universal Controller POLYGYR RWF32... ISO 9001 RWF32... with casing ARG61.01 The RWF32... is a universal digital boiler temperature / pressure controller designed for use in oil- and / or gas-fired heat generating plant. The controller and this data sheet are intended for use by OEMs that integrate the RWF32... in their products! Use The RWF32... is designed specifically for the control of the boiler temperature or steam pressure in oil- or gas-fired heat generating plant. It is also suited as a universal controller for other controlled variables. Functions The RWF32... is a combination of units with the following functions: Digital PID controller that acts on the modulating burner via its three-position output. Using an external operating mode selector, the controller can be switched over and used as a two-position controller for the control of a two-stage burner, for example for oil-firing of a dual-fuel burner Automatic control thermostat (or pressurestat) function in the burner's low-flame operation (with an adjustable reaction threshold for activating high-flame operation, which means low-flame priority) Shift controller for weather-dependent shifting of the setpoint Minimum limiter for the boiler temperature, in the case of weather-dependent shifting of the setpoint Landis & Staefa CC1N7863E January 05, 1998 1/10

Mechanical design The RWF32... is supplied as a plug-in unit with coding plates and labels. Type references AC 230 V version RWF32.000 AC 110 V version RWF32.000A17 Casings, to be ordered as separate items For control panel mounting Individual casing ARG61.00 Casing (attachable) ARG61.04 Flush panel mounting (attachable) ARG61.01 The front of the casings is protected by a transparent plastic cover, which can be swung downward. The terminal base is at the rear. The controller is matched to the controlled variable and the required setpoint setting range by means of setting range inserts, which carry the setpoint setting scale. The setting unit is an integral part of the controller, but switching over to a remote setting unit is possible. All the other setting elements are easily accessible and located behind the unit's front plate. The control parameters can be set and fine-tuned while the burner is running. The settings are analog and can be read directly although the controller provides digital operation. LEDs on the front of the unit indicate the following operational statuses: Control ON/ OFF The positioning pulses OPEN and CLOSE for the actuator of the burner's air damper with modulating burner control, or "Stage I" / "Stage II" in the case of two-stage burner control The digital display below the LEDs shows the deviation of the actual value from the setpoint as a percentage of the range insert's setting range. If a deviation exceeds + 19 % or - 19 %, symbols and appear in place of digits. Measurements and displays are made at 2-second intervals and in increments of 1 %. 2/10 CC1N7863E January 05, 1998 Landis & Staefa

Technical data Operating voltage AC 230 V ±15 % Neutral zone selectable with jumper NZ AC 110 V -15 % / +10 % 1 % or 2 %* (factory setting: 1 %) Frequency 50...60 Hz Power consumption 4.5 VA Slope 0...3 Safety extra low voltage 24 V Safety class II to VDE 0631 Reaction threshold for switching over to high-flame operation, Q 1...33. integral of Perm. loading of control outputs control deviation (in K) x time (in s) (relays K1...K3) - For up to 2 x 10 5 switching cycles Recommended running time of actuator 15...60 s 2 A, AC 24...240 V - For up to 10 7 switching cycles Protection standard of casing 0.1 A, AC 24...240 V - Front IP42, DIN 40050 - Base IP10, DIN 40050 Radio interference protection N to VDE 0875 Proportional band Xp 3.7...150 %* Mounting position optional Integral action time tn 20...250 s Terminals for 2 x 1.5 mm² or 1 x 2.5 mm² Derivative action time tv (D-part) 0...5, (with no unit) Switching differential SD 3...19 %* Weight - Without casing 410 g - With casing 760 g Environmental conditions: CE conformity - Transport IEC 721-3-2 According to the directives of the European Union Climatic conditions class 2K2 Electromagnetic compatibility EMC Temperature range -50...+60 C 89/336 EEC incl. 92/31 EEC Humidity < 95 % r.h. Gas appliance directive 90/396 EEC Mechanical conditions class 2M2 Emissions EN 50081-1 - Operation IEC721-3-3 Immunity EN 50082-2 Climatic conditions class 3K5 Temperature range -20...+60 C Humidity < 95 % r.h. Condensation, formation of ice and ingress of water are not permitted * % of setting range of setting range insert AZW61... Warning notes If the geographical areas where DIN standards are in use, the installation must be in compliance with VDE requirements, particularly with the standards DIN / VDE 0100 and 0722! All regulations and standards applicable to the particular application must be observed! Installation and commissioning work must always be carried out by qualified personnel! The electrical wiring must be made in compliance with national and local standards and regulations! Burner ignition cables must always be laid separately, maintaining the greatest possible distance to the unit and other cables! Check wiring carefully before putting the unit into operation! The RWF32... must be completely isolated from the mains before performing any work on it! Ensure protection against electric shock on the unit and on all electrical connections through appropriate mounting! Electromagnetic emissions must be checked from an application point of view! Landis & Staefa CC1N7863E January 05, 1998 3/10

Function of the controller when used for burner control Control thermostat or pressurestat function When controlling the burner in low-flame operation, the RWF32 basically operates like a control thermostat or pressurestat, that is, it operates as a two-position controller, maintaining the setpoint by switching the burner on and off. To do this, the controller closes the start control loop at terminals Q13 and Q14, which causes signal lamp «0 - I» to light up. The switching differential for this two-position operation can be adjusted within a wide range. This means that the burner's switching ratio can be selected such that low wear operation will be assured. If, during on / off operation, the demand for heat increases, causing the actual value to occasionally drop below the switch-on limit (Sdon) of the selected switching differential, the controller does not immediately switch to high-flame operation, but first checks and ascertains the dynamics of the control deviations and switches to high-flame only when an adjustable limit - the reaction threshold «Q» - is exceeded («Q» is the integral of the control deviation(s) x time). This adjustable reaction threshold is another feature of the RWF32... aimed at reducing the burner's switching ratio if permitted by the control accuracy called for. The function diagrams on the next pages give more details. Changeover of operating mode Two-stage two-position control With an AC 230 V signal fed to terminal «L9», it is determined if, in high-flame operation («Q» exceeded), the RWF32 provides modulating («L9» = 0 V) or two-stage («L9» = AC 230 V) operation. As a modulating controller, the RWF32 operates as a PID controller with a three-position output. In two-stage operation, the selected switching differential «SD» also determines the switching on and off of the second stage, which is indicated by signal lamps «I» and «II». Half of the selected switching differential lies above and half below the setpoint. When the load decreases, the burner will be shut down as soon as the actual value exceeds the setpoint by the total of the switching differential. Operating principle. For connection of fuel valves, refer to "Connection diagram" 4/10 CC1N7863E January 05, 1998 Landis & Staefa

Modulating control With modulating control - in contrast to two-position control - one third of the selected switching differential «SD» lies below and two thirds lie above the setpoint. If the same ratio as with two-position control is required (fifty / fifty), wire link «B2» on the printed circuit board must be cut away. Also, in the case of modulating control, an adjustable neutral zone «NZ», which is 1 % or 2 % of the range insert's setting range, is active. If control deviations exceed the neutral zone, the controller's microprocessor ascertains not only the direction of the positioning pulses (indicated by the signal lamps and ), but also their optimum duration, down to pulse durations of 1/10 second. Adjustable are the P-band, and the derivative and integral action times. Also, as with twoposition control, the controller continuously indicates the deviation of the actual value from the setpoint (as a percentage of the range insert's setting range) so that the plant operator always obtains a clear picture of the accuracy and stability of the control. If, during modulating burner operation, the actual value exceeds the switch-off limit of the selected switching differential, the controller will shut the burner down and resume control operation only when the actual value falls again below the switch-on limit, starting with the control thermostat or pressurestat function, that is, in low-flame operation. If, however, after a long off period, for example, the control deviation is more than twice the selected switching differential, modulating operation will start immediately. This, of course, applies analogously to the above described two-stage burner. Function as a universal controller To provide this function with a freely selectable detector / setting range insert combination of the POLYGYR control system, plug «J1» on the controller's printed circuit board must be removed. Potentiometer «Q», which is required for burner control, is put out of operation by the same action. This means that over the entire control range, the RWF32 now operates as a PID controller with a three-position output and an adjustable neutral zone, which is 1 % or 2 % of the setting range insert's range. The manipulated variable is increased via terminal «Y1», and decreased via terminal «Y2». When using this function, relay «K3» becomes a limit value signalling device. Its contact closes (signal lamp «0 - I» lit) when the actual value falls below the switch-on limit of the selected switching differential and reopens only when the actual value reaches the switch-off limit. One third of the selected switching differential lies below the setpoint and two thirds lie above it. When wire link «B2» is cut, the ratio is fifty / fifty. External setpoint shift External setpoint shift can be accomplished by feeding a DC 0...10 V signal to terminal «Z1 / M». In that case, the setpoint setting slider must be set to «ext». At +5 V, the authority is 0 %. An increase of 1 V raises the setpoint, the shift being 10 % of the setting range insert's range, a decrease of 1 V lowers the setpoint by 10 %. In the case of weather-dependent setpoint shift, a signal at terminal «Z1» will not, however, change the compensation curve, but the minimum limit value set with the slider of the setting range insert! Landis & Staefa CC1N7863E January 05, 1998 5/10

Weather-dependent setpoint shift Weather-dependent setpoint shift is activated as soon as the QAC... outside detector is connected. The lower reference value is not adjustable and represents the "pivot" for the heating curve. Potentiometer «H» is used to set the slope of the heating curve. With weather-dependent setpoint shift, the slider of the setting range insert is used for setting the minimum limitation (e.g. the minimum boiler temperature), whereby the value set (level of switch-on limit) represents the selected switching differential. ϑa H ϑk SD ϑkmin Outside temperature Slope of heating curve Boiler temperature (example) Selected switching differential Minimum boiler temperature Setting range of heating curve slope with weather-dependent shifting of setpoint by the QAC... outside detector in connection with the setting range insert AZW61.113-t30/130 (example). The lower setting value of the setting range insert determines the "pivot" of the heating curve (at 30 C in the above example). ** Characteristic of curve when potentiometer «H» is set to 2.3 and minimum limitation of boiler temperature is set to 65 C (with setpoint setting slider) 6/10 CC1N7863E January 05, 1998 Landis & Staefa

Function diagrams Modulating (PID) control (e.g. for modulating burner), with automatic on / off function in low-flame operation. Two-position control, two-stage, e.g. for two-stage oil-fired burner The diagrams show the control thermostat / pressurestat function on the left (on / off operation). Since the control deviations «q» remain under the reaction threshold «Q» set on the controller, switchover to high-flame operation (two-stage or modulating) will not take place. When the actual value falls repeatedly below the switch-on threshold, the controller adds up the «q»-deviations and switches over to high-flame when the set «Q»-value is reached. However, if the setpoint is reached in low-flame operation, the counter will be reset to zero. At «A», the set reaction threshold is reached and the controller immediately switches to high-flame operation, e.g. it changes to modulating control (top) or two-stage burner control (bottom). This modulating or two-stage burner control will remain operative until the actual value exceeds the setpoint by the value of the set switching differential - independent of the extent of further control deviations. This means burner and control are switched off at «B». Automatic burner restart as soon as the actual value falls below the switching differential. Another change to modulating or two-stage burner control is made at «A», because reaction threshold «Q» is again exceeded. w Adjusted setpoint on Burner on SD Selected switching differential off* Stage I or II off NZ Neutral zone with PID control off Burner off Landis & Staefa CC1N7863E January 05, 1998 7/10

Connection diagram (basic diagram) Note For temperature or pressure control in connection with a dual-fuel burner. Burner control and supervision are provided by a burner control LAL... or LFL... (example). The AC 24 V power supply available at terminals «G» and «M» may only be used for powering the QBE61.6... pressure detector! The voltage for the control signal at terminal «L9» must be picked up at terminal «L» Loads, such as signal lamps, relays, hours run meters, etc., may not be connected to terminal «L9»! Legend a Limit changeover switch for QAC... Outside detector for weather-dependent air damper position fully OPEN shifting of setpoint BS Operation selector QAE... Immersion temperature detector 1 = gas (modulating burner control) QBE... Pressure detector 2 = oil (2-stage burner control) R Boiler control thermostat or pressurestat BV... Fuel valve RV Gas regulating damper FZA... Remote setting unit (becomes operative when SQ... Actuator of burner s air damper and gas setting the built-in setting unit to «ext») control damper K1, K2 Output relays for the control loop's regulating ST Connections of burner control's start unit (in this case: actuator) control loop K3 Limit value relay (potential-free) v Auxiliary changeover switch for the L... Burner control release of the second fuel valve LK Burner's air damper depending on the position of the air L9 See «BS» damper m (MIN) Auxiliary changeover switch for the control W Thermal (or manual) reset limit thermostat of the flow-flame stage or pressure monitor z Limit changeover switch for the fully Z1 Input terminal for reference signal from CLOSED position of the air damper of air / building automation system or similar fuel ratio control Location of plugs «TA», «J1» and «NZ» mentioned in the text, and of wire link «B2» on the controller's printed circuit board B2 Wire link for changing the level of switching differential SD in relation to the setpoint with PID control (B2 cut away = ½ - ½ in place of ¹/ ³ - ²/ ³ ; refer to text) NZ Plug for neutral zone 1 % or 2 % TA When connecting the QAC... outside detector to several (max. 4) controllers in parallel, plug «TA» may be plugged into only one of the controllers J1 When using the RWF32... as a universal controller, plug «J1» must be removed, thus making potentiometer «Q» inoperative The signal delivered by the QAC... outside detector may be fed to a maximum of four RWF32... controllers (parallel connection to controller terminals «B4» and «M»). With this application, plug «TA» may be plugged into only one of the controllers! 8/10 CC1N7863E January 05, 1998 Landis & Staefa

Setting range inserts The setting range inserts are used for determining the controlled variable and the setting range of the RWF32. controller. If the controlled variable required lies within the range of several setting range inserts, the insert with the narrowest range is to be used. For example: a boiler temperature of 180 C requires a setting range of 100...200 C, and not 0...250 C! Controlled variable Setpoint Setting range insert setting range Type reference Temperature 0...130 C AZW61.117-t130 30...95 C AZW61.131t95 30...130 C ** AZW61.113-t30/130 100...200 C ** AZW61.118-t100/200 0...250 C AZW61.114-t250 150...450 C * AZW61.115-t450 Pressure 0...0,5 bar AZW61.292-p0,5 0...2 bar AZW61.292-p2 0...10 bar AZW61.292-p10 0...20 bar AZW61.292-p20 0...40 bar AZW61.292-p40 * For non-landis & Staefa products using sensing elements Pt 1000 Ω ** 1 C = 1 % EB (range of setting range insert) Refer to data sheet 3428 Remote setting unit The remote setting unit becomes automatically active when the setting unit integrated in the controller is set to «ext». Designed for flush panel mounting, measuring 48 x 48 mm. Angular rotation can be locked and limited. The remote setting unit is supplied with a set of scales for all measuring ranges. Refer to data sheet 1981 FZA21.11 Temperature detectors Sensing element: Ni 1000 Ω/0 C Pt 1000 Ω/0 C E.g. type reference QAC22... outside detector refer to data sheet 1811 QAE22... temperature detector refer to data sheet 1791 QAD22... clamp-on detector refer to data sheet 1801 Pressure detectors Use Measuring range Overload-proof up to Type reference Water (ph max. 10) 0...0.5 bar 0.75 bar QBE61.1-p0,5 Water vapour 0...2 bar 3 bar QBE61.1-p2 Compressed air and similar 0...10 bar 15 bar QBE61.1-p10 with a linearized signal DC 0...10 V 0...20 bar 30 bar QBE61.1-p20 0...40 bar 60 bar QBE61.1-p40 Water trap pipe 4 286 1652 0 Refer to data sheet 1901 Landis & Staefa CC1N7863E January 05, 1998 9/10

Dimensions Dimensions in mm RWF32.000/ARG... 1997 Landis & Staefa Produktion (Deutschland) GmbH 10/10 CC1N7863E January 05, 1998 Landis & Staefa