How to get a good centration during SMILE?

Similar documents
SCHWIND AMARIS. We have redefined perfection for you

MEL 80 Excimer Laser. When you want to see better performance

What you should know about LASIK and Femto-LASIK Understanding Laser Vision Correction. Patient information

Transferring wavefront measurements to ablation profiles. Michael Mrochen PhD Swiss Federal Institut of Technology, Zurich IROC Zurich

Overview of Commercially Available Femtosecond Lasers in Refractive Surgery

Fitting Manual Use with kerasofttraining.com

ORIGINAL ARTICLE. Dan Z. Reinstein, MD, MA(Cantab), FRCOphth; Marine Gobbe, MST(Optom), PhD; Timothy J. Archer, MA(Oxon), DipCompSci(Cantab)

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

ifs 150 khz IntraLase Technology

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

Aberration Interaction In Wavefront Guided Custom Ablation

Focus on performance. The SCHWIND AMARIS product family TREAT

Surgical data reveals that Q-Factor is important for good surgical outcome

Fitting Manual Use with

Focus on performance. The SCHWIND AMARIS product family TREAT

Corneal refrac+ve surgery: Are we trea+ng the wrong loca+on with the wrong correc+on?

NON-LINEAR ASPHERIC ABLATION PROFILE FOR PRESBYOPIC CORNEAL TREATMENT USING THE MEL80/90 AND CRS MASTER PRESBYOND MODULE

Optimized Profiles for Astigmatic Refractive Surgery

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

What s New in Ocular Biomechanics?

Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information

DESIGNED FOR SUCCESS...GUARANTEED TO FIT

Contents. Corneal Markers, Scleral Depressors

Refractive Power / Corneal Analyzer. OPD-Scan III

Advanced Technology IOLs

AHEAD Superior technology, thoughtfully designed with you in mind for an intelligent approach to cataract surgery.

Sets distance refraction. Moves camera forward / backward. Moves camera up / down. Moves camera left / right. Starts image acquisition (HRT 3 only)

Trust your eyes. Presbyopic treatment methods on the cornea. PresbyMAX Decision criteria and patient s acceptance

Optical Connection, Inc. and Ophthonix, Inc.

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

Dawn of a New Era Modern LASIK Results. Christopher L. Blanton, MD April 28, 2018

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

Corporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome

ROTATIONAL STABILITY MAKES THE DIFFERENCE

Optical Zone Diameters for Photorefractive Corneal Surgery

4/2/2015. Bonnie An Henderson MD Clinical Professor of Ophthalmology Tufts University School of Medicine Ophthalmic Consultants of Boston

Amico Yasna Pars. What s Inside. Leader in Healthcare Specialty Markets. Ophthalmology Newsletter.

Dr. Magda Rau Eye Clinic Cham, Germany

family of lens designs fitting guide ICD is Exclusively Manufactured In

ULTRA-THIN CUSTOM CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS

Refractive Surgery: Vance Thompson, MD, FACS Refractive Surgeon. Oculeve Wavetec Zeiss Mynosys LRG Equinox Precision Lens ORA Amaken EXCELLens

ULTRA-THIN SPECIALIST CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS

This is the author s version of a work that was submitted/accepted for publication in the following source:

RETINOSCOPY LABORATORY MICHAEL DAVIDSON RON OFRI

The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST - KEY

WITH ACCUMULATING EXPERIENCE AND CONtinuing

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

The Aberration Structure of the Keratoconic Eye

When I began my career as an ophthalmologist,

The influence of the aspheric profiles for transition zone on optical performance of human eye after conventional ablation

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Long-term quality of vision is what every patient expects

Improving outcomes LENSTAR LS 900. Biometry

Corneal Mapping over the Contact Lens. Challenge: Getting the Most out of Soft Contact Lens Multifocals

Schwind Amaris 1050 Smart Pulse Technology

Optical Profile Following High Hyperopia Correction With a 500-Hz Excimer Laser System

Effects of Pupil Center Shift on Ocular Aberrations

CONTACT LENSES FOR KERATOCONUS & ALL IRREGULAR CORNEAS

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

FEMTO LDV Z8 IMAGE-GUIDED SURGERY ENHANCE YOUR SURGICAL PLANNING

Technicians & Nurses Program

Introducing an enlightened scleral lens designed specifically for regular corneas.

HIGH DEFINITION VISION SOLUTIONS THE COMPLETE GUIDE TO LASER VISION CO R R EC T I O N

Centration axis in refractive surgery

FITTING GUIDE PRACTITIONER S ROSE K2 KC ROSE K2 NC ROSE K2 IC ROSE K2 PG NIPPLE CONE IRREGULAR CORNEA POST GRAFT

HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design

Customized intraocular lenses

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST

Unique Aberration-Free IOL: A Vision that Patients

Treatment of Presbyopia during Crystalline Lens Surgery A Review

VARILUX FITTING GUIDE GUIDELINES FOR SUCCESSFULLY FITTING VARILUX LENSES

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results

Introduces The OK -EX -Total Tear Layer Control- Features. What is the OK-EX? Multi-Axis Toric Option.

OpenStax-CNX module: m Vision Correction * OpenStax

Aberrations and Visual Performance: Part I: How aberrations affect vision

OCULUS Pentacam AXL Always an Axial Length Ahead

G.P. MULTIFOCAL LENSES: A FITTING WORKSHOP

Clinical Update for Presbyopic Lens Options

Chapter 3: LENS FORM Sphere

FITTING GUIDE. Applications. Design Options THE CRISP, CLEAR VISUAL ACUITY OF A GP LENS MEETS THE HYDRATING COMFORT OF A SOFT LENS

What is Wavefront Aberration? Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World?

Goldmann Visual Field. Humphrey Visual Field 4/25/2017. What s So Special About Special Testing?! Houston, we have a problem.

Eschenbach Low Vision Training Program

Trouble Shooting Guide for Ortho-K lenses

FOR PRECISE ASTIGMATISM CORRECTION.

Today s subject Auto Refractometer & Auto Ref / Keratometer AR-1 & ARK-1

Irregular Cornea. ROSE K2 Soft TM. Practitioner s Fitting Guide

Evaluate Your Patient s Total Visual System With the OPD-Scan III


Headline. SL 130 Slit Lamp. Subline. Maximum quality for optimum performance

Table of contents. 5 Swiss precision for clear vision. 6 What types of defective eyesight are there? 8 What is refractive eye surgery?

Aberrations Before and After Implantation of an Aspheric IOL

ATLAS Corneal Topography System

Principles and clinical applications of ray-tracing aberrometry (Part II)

The pupil of the eye is a critical limiting factor in the optics

UNITY VIA PROGRESSIVE LENSES TECHNICAL WHITE PAPER

Keratoconus contact lenses

Financial Disclosure. Acufocus. Presbyopia Surgery. Inlay Concept 8/14/17. Presbyopia Correction: The Holy Grail of Ophthalmology

Transcription:

How to get a good centration during SMILE? Walter Sekundo Apostolos Lazaridis Department of Ophthalmology, Philipps University of Marburg, Germany. Prof.Sekundo is a consultant Carl Zeiss Meditec AG

Centration and Tracking Femtolasik Aktive eyetracker Logged on at the pupil centre Can be adjusted by the surgeon according to the 1st Purkinje reflex ReLEx Self-centration: the patient is asked to observe a blinking light during the suction and the surgery Excimer laser VisuMax fs-laser

Mental state of the surgeon Femtolasik ReLEx www.freiheitlich.me www.sueddeutsche.de Excimer laser: I am in charge using sophisticated machinery VisuMax fs-laser: I, the surgeon, have to (partially) rely on the patient

Patient data Groups Patients Mean Age Total Eyes OD OS Gender Full Correction Eyes Mean SEQ (Dpt) Mean Cylinder (Dpt) Mean central Simulated Keratometer readings (Dpt) (n=1.3375) ReLEx 36 37 (22 to 55) 34 35 16 20 51-5.96 (-1.25 to -10) -0.95 (0 to -4.0) 43.53 fs-lasik 36 34 (23 to 65) 33 36 16 20 63-4.96 (-0.75 to -10) -1 (0 to -4.5) 43.43 Surgical data Groups Mean SEQ of the correction (Dpt) Mean Cylinder of the correction (Dpt) Mean Flap/Cap Thickness (μm) Mean Flap/Cap Diameter (mm) Mean Lenticule Thickness/ Ablation Depth (μm) Mean Lenticule/ Ablation Diameter (mm) ReLEx -5.76 (-1.25 to -10) -0.79 (0 to -4.0) 118 (100 to 120) 7.8 (7.5 to 8.0) 120 (48 to 164) 6.7 (6.2 to 7.0) fs-lasik -4.88 (-0.75 to -10) -0.91 (0 to -4.5) 113 (100 to 120) 8.36 (8.0 to 8.5) 103 (22 to 165) 6.32 (6 to 6.75) Lazaridis et al JRS, 2014

Methods Centration Analysis by pachymetry differential maps: Distance of the thickest point from apex (vertex*) and pupil centre ReLEx Smile (OD) Mean Spherical Equivalent of the Correction -4.75 Dpt Decentration from Apex: 0.297mm Decentration from Pupil centre: 0.180 mm Thickest point 1. Find the thickest point (x,y) on the pachymetry diff. map after 3 measurements 2. Estimate the distance between the thickest point and pre-op corneal apex 3. Estimate the distance between the thickest point and pre-op pupil centre as defined by Pentacam using Pythagorean theorem (d= x²+y²) * Close approximation of the visual axis. Pande M, Hilman JS, Ophthalmology 1993

Example Femto-Lasik Fs-LASIK (OD) Mean Spherical Equivalent of the Correction - 5.38 Dpt Decentration from Apex: 0.533 mm Decentration from Pupil Centre: 0.421 Thickest point Fs-LASIK (OS) Mean Spherical Equivalent of the Correction - 5.38 Dpt Decentration from Apex: 0.149 mm Decentration from Pupil Centre : 0.041 mm Thickest point

Example ReLEx ReLEx Smile (OD) Mean Spherical Equivalent of the Correction - 6.75 Dpt Decentration from Apex: 0.103 mm Decentration from Pupil Centre: 0.243 Thickest point ReLEx Smile (OS) Mean Spherical Equivalent of the Correction - 8.25 Dpt Decentration from Apex: 0.863 mm Decentration from Pupil Centre: 1.062 Thickest point

Results Decentration in relation to the corneal apex (0,0) 1.50 OD, OS 1.50 OD, OS 1.00 1.00 0.50 0.50 0.00-1.50-1.00-0.50 0.00 0.50 1.00 1.50 0.00-1.50-1.00-0.50 0.00 0.50 1.00 1.50-0.50-0.50-1.00-1.00-1.50-1.50 ReLEx Mean Decentration: 0.315 fs-lasik Mean Decentration: 0.516

Results Decentration in relation to the pupil centre (0,0) 1.50 OD, OS 1.50 OD, OS 1.00 1.00 0.50 0.50 0.00-1.50-1.00-0.50 0.00 0.50 1.00 1.50 0.00-1.50-1.00-0.50 0.00 0.50 1.00 1.50-0.50-0.50-1.00-1.00-1.50-1.50 ReLEx Nasalisation of the fixation in relation to the pupil centre = positive angle κ Mean Decentration: 0.326 fs-lasik Centration is randomly distributed Mean Decentration: 0.452

Results: Summary 45 40 35 30 25 20 15 10 5 0 Decentration (mm) from pupil centre 42 35 23 16 9 10 1 2 0-0,2 0,2-05 0,5-1 >1 perfect good acceptable poor 35 30 25 20 24 ReLEx Fs-Lasik Decentration (mm) from corneal apex 32 28 31 15 10 9 12 5 0 0-0,2 0,2-05 0,5-1 >1 1 1

Discussion 1. The centration of the treatment zone as measured by Pentacam is in favour of patient controlled fixation during the ReLEx procedure compared to active eye-tracker assisted Femtolasik surgery. 2. Self-centration during ReLEx treatment shows a trend toward nasalisation of the treatment zone in relation to the pupil center (natural angle κ) and is closer to the corneal vertex. 3. Self-centration appears to work better in asian eyes* (mean 0.17 ± 0.09 mm; 100% within 0.50 mm ; 70% within 0.20 mm; and 90% were within 0.30 mm): Head tilt? *Li M. et al. Invest Ophthalmol Sci, May 2014 But does self-centration control cyclotorsion? And What is the degree of cyclotorsion?

Distribution of error and astigmatism Cyclotorsional Axis Error Astigmatism Assuming Normal distribution Mean cyclotorsion: 3.3 ± 2.4 Calculated from 9,887 eyes presenting for LASIK 0.25 D or more error in 11.8% of eyes 0.50 D or more error in 3.1% of eyes Courtesy of DZ Reinstein, London

Ways of cyclotorsion control The Danish method (Ivarsen et al, JRS 2014)

Study by Brar & Ganesh/India, 2016 Once centration achieved eye docked followed by application of suction With the suction on, the extent of cyclotorsion was determined using the reticule in the right eye piece Any cylotorsion was measured in degrees by noting the relative position of the limbal marks in relation to the 0-180 degree axis of the reticule/screen with protractor

PREOPERATIVE DATA Low cylinder ( 1.5D) High cylinder >1.5D NO OF EYES 71 72 Mean SE(D) -5.01 ± 2.45-5.14 ± 2.27 Mean Cylinder(D) -1.09D ± 0.509-2.46 D ± 0.705 Mean Cyclotorsion (Deg) 3.46 (0-15) 2.36 (0-10) Study by Brar & Ganesh/India, 2016

3 months post operative Low cylinder ( -1.5D) High cylinder ( >-1.5D) Mean SE(D) -0.24 ± 0.35-0.37 ± 0.36 Mean Cylinder(D) -0.20 ± 0.40-0.25 ± 0.23 Study by Brar & Ganesh/India, 2016

Study by Brar & Ganesh/India, 2016 CORRECTION INDEX=sia/tia= MEASURE OF AMOUNT OF CORRECTION (IDEAL= 1) <1:UNDERCORRECTION, >1:OVERCORRECTION Low cylinder=0.91 High cylinder=0.92

Study by Brar & Ganesh/India, 2016 Index of success(ios)- RELATIVE MEASURE OF SUCCESS OF CORRECTION, SMALLER THE VALUE, BETTER IOS Low cylinder=0.16 High cylinder=0.06

Ways of cyclotorsion control My current routine approach: Reticule in the eye-piece is in the non-dominant eye This reticule is aligned with the screen reticule Watch the Purkinje image in the 1 st position (observation) Applanate up to 90%, but not too hard, watching for rotational movements Marks at 3-9 o clock position outside the laser area, if cyl> 1.5D Adjust the head in the observation position (prior to suction) Correct if necessary by twisting the suction cone ( contact glass ) If possible use larger zones (6.5-6.8mm)