VIP Current & Power Multimeter

Similar documents
Installation & Operation Manual ELNet VIP

ElNet VIP Current & Power Multimeter

TNM96-ETL Energy Meter & Electrical Powermeter

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

DPF-MAC Auto power factor controller

Data Sheet. RISH Master Record %THD

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PM-PA/PM-PAC POWER ANALYZER

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

Digital Multifunction Instrument - Rish Master 3440

Elnet GR\PQ. Electrical Measurements & Power Quality. Ver. 1.7

Installation and Operating Instructions

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Monitoring Electric Network Via Internet

SUPPLY NETWORK ANALYZER CVM-96 SERIES

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

RTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03

These parameters are available only on EMC-D3b-485 model and readable only by RS485 interface.

PLA 33. Power line analyzer. User and service manual. version 2.4

Ziegler EM 1320/30/40

Contents. Introduction and description Package contents Device identification PM Options... 80

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Centrale de mesure Power Meter PM500 Merlin Gerin

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Power analyzers and Energy Meters Power Analyzer Type WM14-96

ULTRA RAPID POWER QUALITY ANALYZER

Tegra 710 and 810 Digital metering with RS485 Modbus TM o/p

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202

RISH Master 3440i/3440iDL 0.2S

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

POWER ANALYZER CVM-MINI SERIES INSTRUCTION MANUAL M A CIRCUTOR, SA

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

Technical Data Sheet AMIK 300 / 301

ASCO 5210 Digital Power Meter. Operator s Manual DANGER

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

AMIK 200 / 201 Technical Data Sheet

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems

Operating Manual RISH EM 1320/30/ _Rev. C - 9/2014

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

-EMM-4h. INSTRUCTION MANUAL IM442-U-M v0.6 ELECTRICAL MULTIFUNCTION METER

Energy Management Modular Smart Power Transducer Type SPT-90

Integra 1560 and 1580 Digital Transducer Systems

ma/bcd Converter Model MFC-201 ma/bcd The MFC-201 ma/bcd Converter is a device designed to convert a DC current signal into BCD (8421) signals.

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

ELECTRICAL MULTIFUNCTION METER

Energy Management Energy Meter Type EM21 72R Retro-Fit

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

USER S MANUAL EMPOWER POWER METER TRINITY. Empower Operational Manual

PROCESS & TEMPERATURE CONTROLLERS

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

Energy Management Three-phase energy meter with output modules Type EM4-DIN

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

FCR 06, FCR 12. Power factor correction controller. User and service manual

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Position Indicator model MFC-300/IP. Technical Manual. Licht

Operating Guide October 2006

Metasys Integrator Power Measurement Ltd. Application

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

SUPPLY NETWORK ANALYZER

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

HSIANG CHENG ELECTRIC CORP.

Technical Data Sheet. x1000. kwh R Y B

PEM353. Universal measuring device

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

DUCATI INSTRUMENTS COMPARISON TABLE

3-phase meter with direct connection and pulse or Modbus RS485 output

Energy Management Energy Meter Type EM340

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

Energy Management Energy Analyzer Type EM111

Acuvim-X Series Multifunction Power Meter

Metasys Integrator ESAM E as VND device Application

V Pg. M1: V, V, V Pg. M1 R1: Relay 1 Pg. M1 R2: Relay 2 (three-phase only) output status output status KW Pg. M2:,, Pg. M2n: neutral Pg. M3: P1, P2, P

Energy Management Modular Power Analyzers Type WM2-96

Energy Management Energy Meter Type EM112

Energy Management Energy Meter Type EM111

N30P DIGITAL PANEL METER

EIG DNP V3.0 Protocol Assignments

LARSEN & TOUBRO LIMITED

C u t l e r- H a m m e r. IQ Analyzer START Q U I C KS TA RT G U I D E

Technical Data Sheet

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

MODBUS RS485 SERIAL PROTOCOL

NETWORK ANALYZERS Analyzers

ZHUHAI PILOT TECHNOLOGY CO., LTD.

APPENDIX APPENDIX A 1

JBus/Modbus Communication Card

Energy Management Modular Smart Power Quality Analyzer Type WM3-96

Transcription:

VIP Current & Power Multimeter Rev 1.6

Table of Contents 1. Mechanical Installation... 3 2. Wiring diagram... 4 3. Specifications... 5 Technical Specifications... 5 3.2 Measuring Specifications... 5 4. Current transformer ratio settings... 6 5. Measured values display... 6 6. Peaks display... 7 7. Indication led... 7 8. Communication Settings:... 8 8.1 Communication Address:... 8 8.2 Baud Rate:... 8 8.3 Available Baud Rates for the ElNet VIP... 8 Parity:... 8 8.5 Set up Communication... 9 9. No volt relay... 10 9.1 General:... 10 9.2 No volt alarm setting:... 10 9.3 Phase order alarm:... 10

Dear customer, thank you for selecting the VIP Multimeter for measurements of voltage, current, power and power factor. 1. Mechanical Installation Comment: Please do not install the VIP Multimeter close to electrical bars. Please leave enough space for approaching the device from its back side for providing technical support. 1.1 Please choose the proper place for installation in panel and prepare a square hole according to exhibit below. Height 90 mm Width 90 mm Space in the electrical panel 1.2 Please insert the VIP Multimeter into the suitable space which is to be prepared in advance. Make sure that the device is inserted in the right direction. The device has a plastic knob which adjusts itself for installation in electrical panels. The thickness of the panel door should be less than 4 mm.

2. Wiring diagram

3. Specifications 3.1 Technical Specifications Item Description Power requirements 110 or 220 VAC ± 10%, 60/50 Hz, 20VA Dimensions (HxWxD) 96x96x80 mm Shipping Weight 514 gr. Voltage limits 1000VAC Current limits 50A Enclosure material ABS + Antiflame Operating temperature -20 - + 70 C Storage temperature -20 - + 80 C Humidity 0-90 RH% Voltage input terminals VL E10 1708 Mounting Front panel mounting Digital Output (optional) Dry contact 3.2 Measuring Specifications Measurement Parameter Display Range in direct connection (scaling factor 1) Measuring in direct connection (scaling factor 1) Display Range Current 0.01 6A 0.01 6A 0.01 999KA Neutral Current 0.01 6A 0.01 6A 0.01 999KA (calculated ) Voltage L-N 0.00 650 V 0.00 650 V 0.01 999KV Voltage L-L 0.00 650 V 0.00 650 V 0.01 999KV Frequency (Hz) 45.1-65.1 Hz 45.1-65.1 Hz 45.1-65.1 Hz Active power total\phase 0.00W 999KW Reactive power total\phase 0.00VAR - 999KVAR Apparent power total\phase 0.00VA - 999KVA Power Factor (cap.\ind.) -1.00 1.00-1.00 1.00-1.00 1.00

4. Current transformer ratio settings 4.1 Press the "Enter" button for about 6 seconds. 4.2 The enter password screen will appear: "COD". 4.3 Use " " button to change the code to "1" and press Enter. 4.4 The current transformer set screen will appear. 4.5 The headline "SET" will be displayed on the screen, on the second line the secondary value of current transformer (5A), the third line allows to define the value of the primary current transformers with the " " buttons. At the end press Enter. 5. Measured values display 5.1 Use the " " buttons to browse among all the display screens including three-phase display of voltage, current, power, frequency, power factor and integrated screens of voltage, current and power factor for each phase.

6. Peaks display 6.1 Pressing the Hi/Lo button (each press replaces screens circularly), enables you to browse among the screens specifying the peak of voltage and current that were ever measured for each phase. The first screens display the highest values measured of voltage and current (Hi); the next screens display the lowest values measured of voltage and current (Lo) and then respectively high and low frequency and power factor for each phase. 7. Indication led 7.1 The indication led easily enables to identify whether there is voltage in phases L1, L2, L3. In case there is voltage in phases connections the led will be turned on (50 VAC at least).

8. Communication Settings: In order to connect the ElNet VIP Power Multimeter to a PC or other device, for successful communications, both Communication Setup parameters must match; i.e. the PC port and the configuration settings of the Power meter, Address, Baud Rate, Parity must match. 8.1 Communication Address: Each Power meter in a communication system must have its own unique address. ElNet VIP works on MODBUS protocol, so the available addresses are - from 1 to 247. 8.2 Baud Rate: The Baud Rate is the communication speed in Bits per second (BPS) for communication between ElNet VIP with the PC or other device. The better the communication line quality, the faster the communications may be (higher Baud Rate value). If the communication line is routed through a noisy environment, it may be necessary to decrease the Baud Rate. 8.3 Available Baud Rates for the ElNet VIP Are: 300; 600; 1200; 2400; 9600; 19200 bps. 8.4 Parity: The parity can be defined as ODD, NONE or EVEN.

8.5 Set up Communication 8.5.1 Press the "Enter" button for about 6 seconds until the insert password screen will appear. 8.5.2 Use the " " to change the password (COD) to "2" and press "Enter". 8.5.3 The message "SET" will blink on the screen. On the second line, you will find the functions that require setting. Figure 6.1 Communications settings 8.5.4 Use the " " buttons to chose the required communication feature and press "Enter": Address "Adr" can be changed by using " " buttons from 1 to 255, when finished press "Enter". Baud "bud" use the " " buttons to choose 300,600,1200,2400,4800,9600,19200. Parity "PAr" - use the " " buttons to choose from: O81 - ODD, 8 data bit, 1 Stop bit. E81 - EVEN, 8 data bit, 1 Stop bit. n81 - NONE, 8 data bit, 1 Stop bit.

9. No volt relay 9.1 General: When the voltage is proper (above 50VAC, adjustable) and the phases' order is proper the indication relay is closed, as appears at the wiring diagram. The maximum current that is possible to transfer through this relay is 150ma which is enough to operate a regular control relay. 9.2 No volt alarm setting: 9.2.1 In order to set the minimum voltage value for the no volt relay press the "Enter" button for about 6 seconds. 9.2.2 Use the " " buttons to change the password to "code 21" and press "Enter". 9.2.3 "SET AL" will appear and it would be possible to set the min. voltage ratio by using the " ". After setting this value save it by pressing the "Enter" button. 9.3 Phase order alarm: 9.3.1 In order to turn ON/OFF the phase order relay, press the "Enter" button for about 6 seconds. 9.3.2 Use the " " buttons to "code 31" and press Enter. 9.3.3 The phase order screen will appear and it would enable you to select YES/NO (equivalent to ON/OFF). After setting the desirable option save it by pressing the "Enter" button.