RCMS460 and RCMS490 Series

Similar documents
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

ISOMETER IRDH575. Approvals

Measuring current transformers of the W AB(P) series

ISOMETER iso685- -B. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet

Measuring current transformers of the W, W series

ISOMETER iso685- Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Technical data Insulation fault location system Device components

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

The Power in Electrical Safety

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PEM353. Universal measuring device

27/04/2015

ISOMETER iso685-d-p. Device features

Measuring current transformers of the W B series

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Power Quality and Energy Measurement PEM330/PEM333

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Power Quality and Energy Measurement PEM575

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Power Quality and Energy Measurement PEM735

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Power Quality and Energy Measurement PEM533

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Control module CP-A CM

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Three-phase monitoring relays

Power Quality and Energy Measurement PEM575

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories


Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Single phase meter with direct connection and pulse or Modbus RS485 output

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Electronic timer CT-SDS.22

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Supplemental Motor Protection Devices Table of Contents

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Three-phase monitoring relay CM-PFS

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Electronic timer CT-TGD.22

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Electronic timer CT-MFS.21

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

Installation / Monitoring Technique

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Thermistor motor protection relays

Monitoring Relay MR 50

Liquid level monitoring relay CM-ENS.2x

05/09/2012

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Control module CP-A CM

JUMO Wtrans Receiver with Wireless Data Transmission

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Protection components

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

3-phase meter with direct connection and pulse or Modbus RS485 output

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Three-phase monitoring relays CM-PFE and CM-PFE.2

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

02/11/2015

Electronic relays. Monitoring. Monitoring

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Product overview Residual current monitoring

Type CP-S, CP-C & CP-A Switch mode

02/11/2015

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Transcription:

4 T M RCMS460 and RCMS490 Series Digital Multi-Channel Ground Fault Monitor / Ground Fault Relay Grounded and High-Resistance Grounded AC/DC Systems Technical Bulletin NAE1042060 / 04.2013

BENDER Inc. 700 Fox Chase, Coatesville PA 19320 Ph: 800-356-4266 / 610-383-9200 Fax: 610-383-7100 RCMS460 / RCMS490 Series Multi-Channel Ground Fault Monitors for Grounded AC, DC, and AC/DC Systems RCMS460-D / -L and RCMS460-D / -L Device features Selectably monitor either pure AC, pure DC, or AC/DC mix on each separate channel True RMS value measurement 12 separate monitoring channels, each with its own settings adjustment AC ground fault detection up to 2000 Hz Fast parallel scanning for all channels Response ranges 10 ma 10 A (DC or AC/DC mix) 6 ma 20 A (AC only systems) Latching or non-latching operation Three separately adjustable time delays Adjustable frequency behavior for protec tion of persons, fire protection and plant protection History memory with date and time stamp for 300 data records Data logger for 300 data records / channel Analysis of harmonics, DC, THD Two Voltage-free SPDT contacts for entire device RCMS490: Additionally one voltage-free SPST contact for each channel Selectable between normally energized and normally de energized operation TEST / RESET button, internal / external -D version: Digital backlit LCD display Data exchange via BMS bus Password protection Continuous CT connection monitoring Conforms to RoHS Approvals Description The RCMS460 and RCMS490 monitor for ground faults in multiple grounded and high-resistance grounded AC, DC, and AC/DC systems. The RCMS460 and RCMS490 are specifically designed to provide advanced warning of developing ground faults without the problems associated with high sensitivity nuisance tripping. Each RCMS device can monitor up to 12 circuits. Each channel can be separately adjusted to whether it is monitoring pure AC, pure DC, or mixed AC/DC. Setpoints are also separately adjustable on each channel. AC systems up to 2000 Hz can be monitored. Values are read as true RMS values. The RCMS460 has 2 common SPDT contacts for the device. The RCMS490 has 2 common SPDT contacts, as well as separate SPST contacts for each channel. The common SPDT contacts may be set for normally energized or de-energized operation, as well as latching or non-latching operation. The -D series features a high quality, backlit LCD display. Detailed analyses are available for each separate channel, as well as for any harmonics that may be on the system. A fullfeatured onboard menu combines ease of use with flexibility of settings. In addition, the RCMS series can be used for over- and undercurrent protection on single conductors. An option to use an x/5 ratio current transformer (programmable into the device) allows for a wide range of load currents to be monitored. Applications Ground fault detection on multiple systems with single- or three-phase AC (up to 2000 Hz), pure DC, or mixed of AC and DC power Generators Motors and motor control centers Industrial controls Heat tracing systems Over- and undercurrent protection on single conductors Function Measurements of the system's ground fault current are taken via external current transformers. On the -D version, each channel's current value is displayed in graphical form. If the measured value exceeds the response value for one or more channels, the common main alarm SPDT contact will switch over, and an alarm message for that channel will display on the LCD screen. The common alarm LED will also illuminate. On the RCMS490, the channel's corresponding SPST contact will also switch over. If the channel is set to non-latching mode and the ground fault clears, the alarms will then clear. If the channel is set to latching mode, the alarms will not clear until the device is reset manually or the supply voltage is lost. The device features three separately adjustable time delays: Startup delay (while RCMS is starting), response delay (after alarm is found), and delay on release (after alarm clears). The TEST function allows for an internal operation testing of the device. The device's easy to use onboard menu manages all settings via the detailed LCD display. An optional password protection setting protects unauthorized users from changing settings. One current transformer is required for each channel. All legs / phases are placed through the current transformer. Depending on the type of circuit being monitored, one of the following CTs is required (CTs are interchangeable for each separate channel): AC-only systems: W series (circular type) WR series (rectangular type) WS series (split-core type) DC or mixed AC/DC systems: WAB series In addition, for each set of 6 WAB transformers, one AN420 is required. 2

History memory in RCMS460-D, RCMS490-D The -D version features a history memory storing up to 300 data records per channel (date, time, channel, event code, measured value) in nonvolatile memory. Data can be accessed either on board the device or through one of BENDER's protocol converters. Analysis of harmonics The analysis of the harmonics of the measured currents can be selected via a menu item in the -D versions. The DC component, the THD factor and the current value of the harmonics (1 40 at 50 / 60 Hz, 1 5 at 400 Hz) are displayed numerically and graphically. Model variations RCMS460-D The RCMS460-D utilizes a digital, backlit LCD display with a full-featured menu for settings for each separate channel. Graphs of each separate channel as well as the harmonics can be displayed. In addition, one RCMS460 can apply settings across multiple interconnected RCMS devices. A common DPDT contact is available on the device. RCMS460-L The RCMS460-L utilizes a two-digit 7 segment display where the address of this device is displayed within the BMS bus. The alarm LEDs indicate the measuring where the response value has been exceeded. This unit requires at least one -D be on the system. RCMS490-D / RCMS490-L The RCMS490-D and -L versions correspond with the RCMS460 units above. In addition, one SPST contact is available for each channel. Overview of device types Distinctive device features RCMS460-D RCMS460-L RCMS490-D RCMS490-L Ground fault setpoint ranges DC and mixed AC/DC, AB type curernt transformers (type B) AC-only system, standard current transformers (type A) 10 ma 10 A 6 ma 20 A 10 ma 10 A 6 ma 20 A 10 ma 10 A 6 ma 20 A 10 ma 10 A 6 ma 20 A Allows for digital inputs Backlit, digital LCD display -- -- 7-segment display and LED line -- -- Paramater setting onboard device -- -- Password protection -- -- Display error code Address range 1 90 1 90 1 90 1 90 Master / slave operating principle Internal clock -- -- Common alarm relay(s) for all channels 2 SPDT contacts 2 SPDT contacts 2 SPDT contacts 2 SPDT contacts Alarm relay per channel -- -- 12 SPST contacts 12 SPST contacts Analysis of harmonics I Δn, DC, THD --* --* History memory 300 data records (overall) -- -- Data logger for 300 data records (per channel) -- -- PRESET function --* --* Number of measuring channels 12 12 12 12 Enclosure type XM460 XM460 XM490 XM490 * only in combination with RCMS4 -D 3

Operating and display elements: RCMS460-D / -L and RCMS490-D / -L 1 2 3 4 5 6 7 8 10 9 1 - LED ALARM 2 : Illuminates when the measured value "Alarm" of any channel has been exceeded. 2 - LED ALARM 1 : Illuminates when the measured value "Prewarning" of any channel has been exceeded. 3 - LED ON : Illuminates when power is received to the unit. 4 - Backlit LCD display 5 - INFO key: Displays pertinent system information (does not apply to RCMS4 -L) ESC key: Exits the menu without changing parameters 6 - TEST button: Activates self-test Arrow up key: Scrolls up inside device's menu 7 - RESET button: Resets device Down key: Scrolls down inside device's menu 8 - MENU key: Toggles between the standard display, the device's internal menu, and alarm display. (does not apply to RCMS4...-L) SET key: Sets addresses of -L devices on the system Enter key: Confirm change inside device's menu 9 - Alarm LEDs 1 12 : Illuminate when the corresponding channel has a ground fault. Flashes when the corresponding channel has a current transformer connection error. (-L only) 10 - Seven-segment display for device address and error codes (-L only) 4

Wiring diagram: RCMS460-D / -L Wiring diagram: RCMS490-D / -L 2 2 9 1 8 6 7 1 8 3 4 5 6 7 3 4 5 1 - External supply voltage used to power device 6 A fuse recommended for internal short circuit protection 2 - Connections for current transformers CT1 CT12. Either Type A or Type B measuring current transformers can be selec ted for each measuring channel. Six W AB series measuring current transformers require one AN420-2 power supply unit. 3 - RS-485 interface (using the BMS bus protocol) 4 - External reset button (normally de-energized contact) 5 - External test button (normally de-energized contact); the external T / R cannot be connected in parallel to other devices. 6 - Alarm relay K1: ALARM 1, common alarm for prewarning or alarm device error 7 - Alarm relay K2: ALARM 2, common alarm for prewarning or alarm device error 8 - R on / off: Activate or deactivate the BMS bus terminating resistor (120 Ω) 9 - SPST contacts (normally de-energized operation, 490 only) 5

Wiring, current transformers: W, WR, WS series (AC-only systems, type A) Example: W series Wiring diagram, current transformers: WAB series (DC and AC/DC mix, type B) Wiring, current transformers: WF series Wiring: digital inputs Current Transformer WF... 1 2 Loads Signal Converter RCC420 Ground Fault Monitor RCMS460 / RCMS490 Optional analog output 1 - Voltage-free contact 0 > 250 Ω I < 100 Ω 2 - Current transformer input for next channel 6

Example system: RCMS460-D monitoring 7 channels of differing types Current transformers for AC/DC loads (0 2000 Hz) Grounded System Current transformers for AC loads (42 2000 Hz) 1 Frequency settings The frequency response of the equipment can be set to a linear frequency response (up to the maximum frequency of 2000 Hz) if used for fire protection or to a frequency response in accordance with IEC 60990 for personnel protection. For plant protection, the ground fault current is measured up to the rated system frequency. The figure below shows the corresponding frequency response. Frequency curves and filter settings 1 2 3 4 Response factor = I / I n (I ) Ground fault current: Measured value at which the RCMS responds. (I n) Rated ground fault current: Set response value 1 - Menu selection 50 Hz Plant protection: Only evaluates the fundamental component of the ground fault current. 2 - Menu selection 60 Hz Plant protection: Only evaluates the fundamental component of the ground fault current. 3 - Menu selection IEC Touch current for let-go (protection of persons) in accordance with IEC 60990 4 - Menu selection None Fire protection: Response factor remains the same over the entire frequency range. 7

8 Technical data Insulation coordination acc. to IEC 60664-1 / IEC 60664-3 Rated insulation voltage 250 V Rated impulse voltage / pollution degree 4 kv / III Protective separation (reinforced insulation) between (A1, A2) (k1 / l k12 / R / RT / T, AB) (11, 12, 14) (21, 22, 24) Voltage test according to IEC 61010-1 2.21 kv Supply voltage Supply voltage U S see ordering information Frequency range U S see ordering information Power consumption 5 VA (RCMS460) / 8 VA (RCMS490) Measuring circuit External current transformer W, WR, WS series (Type A) W AB series (Type B) CT monitoring on / off (on)* Load 68 Ω Rated insulation voltage (measuring current transformer) 800 V Operating characteristic acc. to IEC 60755 Type A and Type B depending on the CT type (Type A)* Rated frequency 0 2000 Hz (Type B) / 42 2000 Hz (Type A) Cut-off frequency none, IEC, 50 Hz, 60 Hz (none)* Measuring range 0 30 A (CT Type A) 0 20 A (CT Type B) crest factor up to 10 A = 4, up to 20 A = 2 Rated residual operating current I Δn2 (Alarm) 10 ma 10 A (Type B) 6 ma 20 A (Type A) (100 ma overcurrent)* Rated residual operating current I Δn1 (prewarning) 10 100 % x I Δn2 min 5 ma (50 %)* Digital input 1 < 100 Ω 0 > 250 Ω Preset for alarm Offset: 0 20 A (30 ma)* and I Δ x factor 1 99 (3)* Preset for digital input 0 / I (I)* Relative percentage error 0-20 % Hysteresis 2 40 % (20 %)* Factor for additional CT 1 10; x 1 250 (x 1)* Number of measuring channels (per device / system) 12 / 1080 Specified time Starting delay t (startup) per device 0 99 s (0 ms)* Response delay t on per channel 0 999 s (200 ms)* Release delay t off per channel 0 999 s (200 ms)* Operating time t ae at IΔn = 1 x IΔn1 / 2 180 ms Operating time t ae at IΔn = 5 x IΔn1 / 2 30 ms Response time t an (IΔn) tan = tae + ton1 / 2 Operating time I / 0 inputs < 3,5 s Scanning time for all channels (I Δn) 180 ms Recovery time t b 500 600 ms Displays, memory Display range measured value 0 30 A (CT Type A) 0 20 A (CT Type B) Display accuracy ± 10 % LEDs ON / ALARM (RCMS4 -D) ON / ALARM / channel 1 12 (RCMS4 -L) LC display backlit graphical display (RCMS4 -D) 7-segment display 2 x 7.62 mm (RCMS4 -L) History memory 300 data records (RCMS4 -D) Data logger 300 data records per channel (RCMS4 -D) Password off / 0 999 (off)* Language D, GB, F (GB)* Fault memory alarm relay on / off (off)* Inputs / outputs TEST / RESET button internal / external Cable length for external TEST / RESET button 0 32 ft (0 10 m) Interface Interface / protocol RS-485 / BMS Baud rate 9600 baud Cable length 0 1200 m Recommended cable (shielded, shield on one side connected to ground) J-Y(ST)Y min. 2 x 0.8 Terminating resistor 120 Ω (0.25 W) can be connected via DIP switch Device address, BMS bus (RCMS -D / -L) 1 90 (2)* Cable lengths for measuring current transformers W, WR, WS Single wire AWG 18 (0.75 mm 2 ) 0... 3 ft (0 1 m) Single wire, twisted AWG 18 (0.75 mm 2 ) 0... 32 ft (0 10 m) Shielded cable AWG 20 (0.5 mm 2 ) 0... 130 ft (0 40 m) Recommended cable (shielded, shield on one side to terminal l, not connected to ground) J-Y(ST)Y min. 2 x 0.8 Cable lengths for measuring current transformers W AB Single wire AWG 18 (0.75 mm 2 ) 0 32 ft (0 10 m) Connection plug-in connector, recommended WXS Switching elements Number of changeover contacts 2 SPDT contacts (RCMS460) 2 SPDT contacts, 12 SPST contacts (RCMS490) Operating principle normally energized or de-energized Electrical service life under rated operating conditions 10.000 switching operations Contact data acc. to IEC 60947-5-1 Utilization category AC-13 AC-14 DC-12 DC-12 DC-12 Rated operational voltage 230 V 230 V 24 V 110 V 220 V Rated operational current 5 A 3 A 1 A 0.2 A 0.1 A Minimum contact load 1 ma at AC / DC 10 V Environment / EMC EMC IEC 62020: 2003-11 Operating temperature - 13 F + 131 F (- 25 C + 55 C ) Climatic class acc. to IEC 60721 Stationary use (IEC 60721-3-3) 3K5 (except condensation and formation of ice) Transport (IEC 60721-3-2) 2K3 (except condensation and formation of ice) Long-time storage (IEC 60721-3-1) 1K4 (except condensation and formation of ice) Classification of mechanical conditions IEC 60721 Stationary use (IEC 60721-3-3) 3M4 Transport (IEC 60721-3-2) 2M2 Long-time storage (IEC 60721-3-1) 1M3 Connection Connection screw terminals rigid / flexible AWG 24 12 / 24... 14 Multi-conductor connection (two conductors of the same cross section) rigid / flexible AWG 24 12 / 24 12 Stripping length 8 9 mm Tightening torque 0.5 0.6 Nm Other Operating mode continuous operation Position of normal use any Degree of protection, internal components (IEC 60529) IP30, NEMA 1 Degree of protection, terminals (IEC 60529) IP20, NEMA 1 Enclosure material polycarbonate Flammability class UL94V-0 Screw mounting 2 x M4 DIN rail mounting acc. to IEC 60715 Standards IEC 62020 Technical manual TGH 1393 Weight 0.8 lb (RCMS460) 1.2 lb (RCMS490) ( )* Factory setting

Ordering information Type Supply voltage U S* Art. No. RCMS460-D-1 DC 16 94 V AC 42 460 Hz 16 72 V B 9405 3001 RCMS460-D-2 DC 70 276 V AC 42 460 Hz 70 276 V B 9405 3002 RCMS460-L-1 DC 16 94 V AC 42 460 Hz 16 72 V B 9405 3003 RCMS460-L-2 DC 70 276 V AC 42 460 Hz 70 276 V B 9405 3004 RCMS490-D-1 DC 16 94 V AC 42 460 Hz 16 72 V B 9405 3005 RCMS490-D-2 DC 70 276 V AC 42 460 Hz 70 276 V B 9405 3006 RCMS490-L-1 DC 16 94 V AC 42 460 Hz 16 72 V B 9405 3007 RCMS490-L-2 DC 70 276 V AC 42 460 Hz 70 276 V B 9405 3008 Type Supply voltage U S* Art. No. AN420-2 DC 70 276 V / B 9405 3100 (power supply unit for six W AB) AC 42 460 Hz 70 276 V Accessories Type Art. No. Mounting clip for enclosure XM420 B 9806 0008 (1 piece per device) Snap-on mounting for W20 / W35 B 9808 0501 Snap-on mounting for W60 B 9808 0502 For further information about measuring current transformers, please refer to the respective data sheets. Dimensions: RCMS Dimensions in inches (mm) 2.9 (74) 1.9 (47.5) 1.2 (31) 4.25 (108) Connector cable for RCMS, "AB" type current transformers, and AN420 power supply Type Length in ft (m) Ordering No. WXS-100 3' (1) B 5111 00028 WXS-250 8' (2.5) B 5111 00029 WXS-500 16' (5) B 5111 00030 WXS-1000 32' (10) B 5111 00027 WXS-1500 50' (15) B 5111 00035 2.7 (67.5) 1.8 (45) Ø 0.18 (4.5) 3.9 (98) 3 (77) 3.5 (90) Current transformers, DC and AC/DC mix (Type B) Type Inside diameter in inches (mm) Ordering No. W20AB ø 0.75" (20) B 9808 0008 W35AB ø 1.35" (35) B 9808 0016 W60AB ø 2.25" (60) B 9808 0026 W120AB ø 4.7" (120) B 9808 0041 W210AB ø 8.25" (210) B 9808 0040 2.7 (67.5) 1.8 (45) 2.9 (74) 1.9 (47.5) 1.2 (31) 6.4 (162) 3 (77) 3.5 (90) Current transformers, AC-only system (Type A) Type Inside diameter in inches (mm) Ordering No. W20 ø 0.75" (20) B 9808 0003 W35 ø 1.35" (35) B 9808 0010 W60 ø2.25" (60) B 9808 0018 W120 ø 4.7" (120) B 9808 0028 W210 ø 8.25" (210) B 9808 0034 WR70x175 2.75" x 6.9" (70 x 175) B 9808 0609 WR115x305 4.5" x 12" (115 x 305) B 9808 0610 WS20x30 (split-core) 0.75" x 1.35" (20 x 30) B 9808 0601 WS50x80 (split-core) 2" x 3.1" (50 x 80) B 9808 0603 WS80x120 (split-core) 3.1" x 4.7" (80 x 120) B 9808 0606 Other current transformer types on request. Ø 0.18 (4.5) Dimensions: AN420 Dimensions in inches (mm) Open the front plate cover in direction of arrow. 5.9 (98) 2.66 (67.5) 1.77 (45) 2.78 (70.5) 1.87 (47.5) 1.42 (36) 1.22 (31.1) 3.54 (90) 9

USA Coatesville, PA Toll-Free: 800-356-4266 Main: 610-383-9200 Fax: 610-383-7100 E-mail: info@bender.org T M bender.org bender.org/mobile Canada Mississauga, ON Toll-Free: 800-243-2438 Main: 905-602-9990 Fax: 905-602-9960 E-mail: info@bender-ca.com Document NAE1042060 / 04.2013 / Bender Inc.