Overview of types. Technical data

Similar documents
Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Functional data Factory settings Variable Settings

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Technical data. Parameterisable damper actuator in the

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Technical data sheet. Technical data. Safety notes

Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Technical data. Safety notes

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

Power consumption Operation At rest Wire sizing

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Brief description. Type overview

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

Extension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A..

Type overview. Technical data

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

EY-EM 527: Remote I/O module, ecolink527

Brief description. VAV-Compact MP en-gb Changes reserved 1. Application. Pressure measurement. Actuator

Electromotoric actuators

GMU24. Technical data. Dimensions [mm] For operation of air control dampers in HVAC system Torque: 40Nm Nominal voltage: AC/DC 24V Control: Open/Close

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Rp [ ] [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Adaptive control system for duct and room pressure applications. Table of Contents

EY-EM 522, 523: Remote I/O module, ecolink522, 523

DN [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

AC 01.2 Modbus TCP/IP

Spring Return DuraDrive Proportional Actuator

1-phase AC current Voltages/frequencies Volt Volt 110, 115, , 230, 240 Hz Hz 60 50

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Electromotoric actuators for stroke valves

Explosion proof rotary actuator - On/Off or programmable regulating actuator

AC 01.2 HART Technical data Actuator controls

Actuators for modulating control AME 85, AME 86

Non-Spring Return EconoDrive Proportional Actuator

NRT 105: Electronic fan-coil controller, equiflex

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

1-phase AC current Voltages/frequencies Volt Volt 110, 115, , 230, 240 Hz Hz 60 50

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Power supply CP-D 24/1.3

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Rotary actuators for ball valves

1-phase AC current voltages/frequencies Volt Volt

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

LM Series Direct Coupled Actuator

Type 3374 Electric Actuator

Technote. Actuator Frese OPTIMA. Application. Features actuator DN15-DN32. Features actuator DN40-DN50. Approval.

Output Signal Active Temperature. Electrical data Power Supply DC V, ±10%, 0.5 W

Actuator for modulating control AME 435

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

Technical Instructions Document No EA GQD June 23, OpenAir

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

GLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V

Installation of VAV-Compact Retrofit with ZDMS-..

Rotary gear motor series AG8...

Output Signal Active Note. Output Signal Temperature 22UTH-51 DC V, DC V

Power supply CP-E 24/0.75

Power supply CP-D 24/4.2 Primary switch mode power supply

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Rotary actuators for ball valves

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Type Overview. Technical Data. Outdoor Humidity, Temperature Sensor

Room Sensors. for relative humidity and temperature

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

ph or ORP Transmitter

Power supply CP-E 24/2.5

Rotary actuators for ball valves

Power supply CP-D 12/2.1

Power supply CP-E 24/20.0

Electromotoric actuators for valves

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

Transcription:

echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control dampers up to approx. m Actuating force N Nominal voltage AC/DC V Control: modulating DC... V or variable Position feedback DC... V or variable Lenght of stroke, or mm Communication via BELIMO -Bus Conversion of sensor signals Overview of types ype Stroke (adjustable in steps of mm) Operating range Weight SHA- p to max. mm DC... V... mm. kg SHA- p to max. mm DC... V... mm.7 kg SHA- p to max. mm DC... V... mm. kg echnical data Electrical data Nominal voltage AC V, /6 Hz / DC V Nominal voltage range AC 9.... 8.8 V / DC.6... 8.8 V Power consumption In operation, W @ nominal force At rest. W For wire sizing VA Connection Cable m, x.7 mm Functional data Factory settings Variable Settings Actuating force Min. N @ nominal voltage %, %, 7% reduced... Control Control signal DC... V, input impedance k Open-close, -point (AC only), modulating (DC... V)... Operating range DC... V Start point DC.... V (See also «Overview of types») End point DC.... V... Position feedback (Measuring voltage ) DC... V, max., ma Start point DC.... 8 V End point DC.... V... Position accuracy ±% Stroke See «Overview of types» Direction of stroke at = V Reversible with switch resp. Electronically reversible... Manual override Gearing latch disengaged with pushbutton, can be locked Stroke adjustment Max. 6,, or mm, adjustable in steps of mm, can be limited at both ends with mechanical adjustable end stops Running time s / mm... 6 s / mm... Automatic adjustment of the operating range and the measuring signal to match the mechanical stroke adjustment Override control Manual triggering of the adaption by pressing the «Adaption» button or with the PC-ool MAX (maximum position) = % MIN (minimum position) = % ZS (intermediate position, AC only) = % Sound power level Max. db (A) With a running time Safety Protection class Degree of protection EMC III Safety extra-low voltage / L Class Supply IP in any mounting position NEMA, L Enclosure ype CE according to /8/EC Automatic adaption whenever the supply voltage is switched on, or manual triggering... MAX = (MIN %)... % MIN = %... (MAX %) ZS = MIN... MAX... s = db (A) 6 s = db (A) www.belimo.com -SHA-.. en v. 8.9 Subject to changes / 7

SHA-.. Multifunctional linear actuators, AC/DC V, N, echnical data (Continued) Safety Certification clus according to L 67-A and L 67-- and CAN/CSA E67-: Certified to IEC/EN 67- and IEC/EN 67-- Mode of operation ype Rated impulse voltage.8 kv Control pollution degree Ambient temperature... C Non-operating temperature... 8 C Ambient humidity 9% r.h., non-condensating Maintenance Maintenance-free Dimensions / Weight Dimensions See «Dimensions» on page 6 Weight See «Overview of types» on page Safety notes! he actuator is not allowed to be used outside the specified field of application, especially not in aircraft or any other form of air transport. Assembly must be carried out by trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. he cable must nut be removed from the device. he rotary supports and coupling pieces available as accessories must always be used if lateral forces are likely. In addition, the actuator must not be tightly bolted to the application. It must remain movable via the rotary support (refer to «Assembly notes»). If the linear actuator is exposed to severely contaminated atmosphere, appropriate precautions must be taken on the system side. Excessive deposits of dust, soot etc. can prevent the gear rack from being extended and retracted correctly. If not installed horizontally, the gear disengagement pushbutton may only be actuated when there is no pressure on the gear rod When calculating the required actuating force, the specifications supplied by the damper or slide valve manufacturers (cross section, design, installation site), and the air flow conditions must be observed. If a rotary support and/or coupling piece is used, losses in the actuation force are to be expected. he device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. Product features Mode of operation Converter for sensors Parameterisable actuators Simple direct mounting Manual override Conventional operation: he actuator is controlled with a standard modulating signal of DC... V and travels to the position defined by the control signal. Measuring voltage serves for the electrical display of the damper position... % and as slave control signal for other actuators. Operation on the -Bus: he actuator receives its digital positioning signal from the higher level controller via the -Bus and travels to the position defined. Connection serves as communication interface and does not supply an analogue measuring voltage. Connection option for a sensor (passive or active sensor or switching contact). he actuator serves as an analogue/digital converter for the transmission of the sensor signal via -Bus to the higher level system. he factory settings cover the most common applications. Input and output signals and other parameters can be altered with the MF-H parameterising device or the BELIMO Service ool, MF-P. he actuator can be directly connected with the application using the enclosed screws. he head of the gear rod is connected to the moving part of the ventilation application individually on the mounting side or with the Z-KS coupling piece provided. Manual operation is possible with the pushbutton (the gearing latch remains disengaged as long as the pushbutton is pressed or detented). / 7 -SHA-.. en v. 8.9 Subject to changes www.belimo.com

SHA-.. Product features Accessories Stroke adjustment High functional reliability Home position Multifunctional linear actuators, AC/DC V, N, (Continued) he stroke of the gear rack can be adjusted on both sides in increments of mm by means of mechanical end stops. he actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. When the supply voltage is switched on for the first time, i.e. at commissioning or after pressing the «gear disengagement» switch, the actuator travels to the home position. Pos. direction of stroke switch = = Home position extended retracted he actuator then moves into the position defined by the control signal. Description Data sheet Electrical accessories Parameterising device MF-H - MF-H PC-ool MF-P - MF-P Position sensor SGA, SGE and SGF - SG.. Digital position indication ZAD - ZAD Mechanical accessories Rotary support to compensate lateral forces Z-DS - Z-SH..A.. Coupling piece Z-KS - Z-SH..A.. Mechanical limiter set Z-AS - Z-SH..A.. Electrical installation Notes Connection via safety isolating transformer!! Other actuators can be connected in parallel. Please note the performance data! Wiring diagrams Conventional operation Operation on the -Bus Control signal Measuring voltage Sensor Cable colours: = black = red = white = orange Assembly notes Application without lateral forces Application with lateral forces Caution If a rotary support and/or coupling piece is used, losses in the actuation force are to be expected.! he linear actuator is screwed directly to the housing at three points. Afterwards, the head of the gear rod is fastened to the moving part of the ventilation application (e.g. damper or slide valve). he coupling piece with the internal thread (Z-KS) is connected to the head of the gear rod. he rotary support (Z-DS) is screwed to the ventilation application. Afterwards, the linear actuator is screwed to the previously mounted rotary support with the enclosed screw. Afterwards, the coupling piece, which is mounted to the head of the gear rod, is attached to the moving part of the ventilation application (e.g. damper or slide valve). he transverse forces can be compensated for to a certain limit with the rotary support and/or coupling piece. he maximum permissible swivel angle of the rotary support and coupling piece is, laterally and upwards. www.belimo.com -SHA-.. en v. 8.9 Subject to changes / 7

SHA-.. Multifunctional linear actuators, AC/DC V, N, Functions when operated on -Bus Connection on the -Bus Further actuators and sensors (max. 8) Supply and communication in one and the same -wire cable no shielding or twisting necessary no terminating resistors required Power topology here are no restrictions for the network topology (star, ring, tree or hybrid forms are permitted). Connection of active sensors Connection of external switching contact p Further actuators and sensors (max. 8) Further actuators and sensors (max. 8) Supply AC/DC A Output signal DC... V (max. DC... V) Resolution mv Switching current 6 ma @ V Start point of the operating range must be parameterised on the actuator as.6 V Connection of passive sensors Further actuators and sensors (max. 8) Sensor emperature range Resistance range Resolution Ni 8... 98 C 8... 6 P... C 8... 6 NC... 6 C (depending on type)... 6 k / 7 -SHA-.. en v. 8.9 Subject to changes www.belimo.com

SHA-.. Multifunctional linear actuators, AC/DC V, N, Functions with basic values (only in conventional mode) Override control with AC V with relay contacts a b c z.b. N 7 (DC... V) From controller Functions a b c % Override control with AC V with rotary control switch (DC... V) From controller z.b. N 7 Pos % Functions ZS % (intermediate position) ZS % (intermediate position) % % Control mode in accordance with Control mode in accordance with Remote control... % Minimum limit Z SGA SGF SGE Position sensor Z SGA SGF SGE Position sensor [V] (DC... V) From controller min [%] Master/Slave control (position-dependent) Control with... ma via external resistance DC... V Ω () ()... ma DC... V o the following actuator DC... V Master actuator Slave actuator he resistor converts the... ma current signal to a voltage signal DC... V Position indication Functional check Adapting the direction of rotation ZAD Procedure Apply V to connection and Disconnect connection : For direction of stroke : Actuator travels in the direction of For direction of stroke : Actuator travels in the direction of Short circuit connections and : Actuator travels in the opposite direction www.belimo.com -SHA-.. en v. 8.9 Subject to changes / 7

SHA-.. Multifunctional linear actuators, AC/DC V, N, Functions for actuators with specific parameters Override control and limiting with AC V with relay contacts a b c d e (DC... V) From controller Functions a b c d e CLOSE ) Override control and limiting with AC V with rotary switch Z ) MIN ZS MAX AF (DC... V) From controller z.b. N 7 z.b. N 7 MIN ZS (intermediate position) MAX OPEN Control mode in accordance with ) Caution! his function is only guaranteed if the start point of the operating range is defined as min..6 V -point control Open-close control a b z.b. N 7 Direction of stroke switch a b stop stop Dimensions [mm] Dimensional drawings 7 97 8 6 77 79 8 B 8 ype Max. stroke A B SHA-. 9.7 SHA-. 9.7 SHA-. 9.7 A 6 / 7 -SHA-.. en v. 8.9 Subject to changes www.belimo.com

SHA-.. Multifunctional linear actuators, AC/DC V, N, Operating controls and indicators Direction of stroke switch Switching over: Direction of stroke changes Pushbutton and green LED display Off: No voltage supply or malfunction On: Operation Press button: Switches on stoke adaption followed by standard operation Pushbutton and yellow LED display Off: Standard operation without bus On: Adaption or synchronising process active Blinking: Addressing request sent to master Press button: Acknowledgment of addressing Flickering: communication active. Gear disengagement switch Press button: Gear disengaged, motor stops, manual operation possible Release button: Gear engaged, synchronisation starts, followed by standard operation Service plug For connecting parameterising and service tools Check voltage supply connection a) Off and On Check the supply connections. Possibly and are swapped over. b) Blinking and Blinking www.belimo.com -SHA-.. en v. 8.9 Subject to changes 7 / 7

SH..A.. 779-.C SH..A. / SHA-MF.. / SHA-.. A x Ø max. 8mm mm mm mm B Z-KS M8 Z-KS mm mm ± M8 Z-KS mm Z-DS Z-DS. Z-DS. www.belimo.com M-SH..A.. v. 7.9 /

SH..A.. SHA-SR. / SHASR.. A x Ø max. 8mm B Z-KS M8 Z-KS ± Z-KS M8 Z-DS Z-DS. Z-DS. / M-SH..A.. v. 7.9 www.belimo.com

SH..A.. SH..A.. / SHA-SR. / SHA-MF.. / SHA-.. / SHASR.. N L N L N L AC V / DC V S S S...% SHA.. SHA-S.. AC... V! N L L N L L S S S S S S S S S SHA.. SHA-S.....% AC V / DC V DC V DC V DC V SHA-SR.. SHA-MF.. SHA-.. AC V N L SG.. DC... V DC... V SHASR.. www.belimo.com M-SH..A.. v. 7.9 /

SH..A.. SH..A..P Z-P 6 mm mm...6 mm ype - 6...8 mm ype - 8... mm ype - 6 max Nm / M-SH..A.. v. 7.9 www.belimo.com