Bulletin -HR Plug-in iming Relays Product election/catalog Number Explanation Bulletin ON-Delay iming Relays ocket or Panel Mounted iming Range From. s h -pin base for socket cat. nos. -HN, -HN, -HN rigger: on Reset: off iming Mode upply Voltage rigger Options Reset Options s Cat. No. ON-Delay (A) V AC/DC V AC V DC On Off V AC On Off PD imed + Instantaneous Contact DPD DPD PD imed + Instantaneous Contact -HRCU -HRMU -HRMA -HRCA iming mode description A ON- Delay D OFF- Delay E One hot B Repeat Cycle OFF- B Repeat Cycle ON- C ignal ON/OFF- Delay J One hot Bulletin -HRF Repeat Cycle iming Relays ocket or Panel Mounted Independently adjustable on- and off-time -Pin base for socket cat. nos. -HN, -HN, and -HN DPD contact outputs rigger: on Reset: off Cat. No. Explanation HRF a imer ype Repeat cycle with adjustable ON/OFF times b Function Repeat cycle with OFF start Repeat cycle with ON start HRF D Z a b c d e c Contact DPD A d Z ime Range Z D. s hr U e upply Voltage V AC, / Hz V AC, / Hz; V DC V DC V DC Publication A-CAA-EN-P -
Accessories Bulletin -HR Plug-in iming Relays Accessories Pkg. Qty. Cat. No. Cat. No. -HN crew erminal ube Base ocket Panel or DIN Rail Mounting; Guarded erminal Construction. -Pin for use with Bulletin -HR and -HX timing relays. -HN crew erminal ube Base ocket Panel or DIN Rail Mounting; Open tyle Construction. - Pin for use with Bulletin -HR and -HX timing relays. No retainer clip required. -HN Cat. No. -HN crew erminal ube Base ockets Panel or DIN Rail Mounting; Guarded erminal Construction. -pin for use with PD -HA relays. -HN Cat. No. -HN crew erminal ube Base ockets Panel or DIN Rail Mounting; Open tyle erminal Construction. -pin for use with PD -HA relays. No retainer clip required. -HN Cat. No. -HN DIN (#) symmetrical hat rail x. x m -DR Cat. No. -DR pecialty ocket -pin backwired socket with solder terminals for use with -HR timing relays. Order or multiples of. -HN Cat. No. -HN pecialty ocket -pin back-wired socket with solder terminals for use with Bulletin -HR timing relays. -HN Cat. No. -HN Publication A-CAA-EN-P -
Bulletin -HR Plug-in iming Relays Accessories Pkg. Quantity Cat. No. Cat. No. -HN Frame Adapter For flush or door mounting of all Bulletin -HR and -HX timers. -HN Retainer Clip for Cat. Nos. -HN and -HN ockets with all -HR iming Relays ecures timer in socket. -HN Note: Not required for installation ample Retainer Clips Cat. No. -HN Protective Cover Helps prevent tampering of timing and mode settings. Provides a degree of protection against water and dirt from entering the front of the relay. For use with all Bulletin - HRs and -HX timing relays. Pre-Printed Identification ags contains sheets of pre-printed and blank tags. Each sheet contains sets of the markings CR CR, R R, M M, F, R,, and blank tags. ags are peel-off with sticky backing for easy placement on relays. -HN -N Blank Identification ags contains sheets of blank identification tags for customer specialized printing. Each sheet contains blank tags. ags are peel-off with sticky backing for easy placement on relays. -N Bulletin -HR Multi-function, Multi-Range Dial iming Relay, ocket, Retainer Clip Reference Chart imer ype -HR, -HR, -HRV, -HRQR -HR, -HR, -HRP, -HRC, -HRM, -HRF, -HRY, -HRQN Design of these sockets holds the timing relays securely and does not require retainer clips. pins. + pins. ocket Cat. No. Retainer Clip Cat. No. -HN -HN -HN Not Required -HN Not Applicable -HN -HN(ee note above) -HN Not Applicable -HN Not Required - Publication A-CAA-EN-P
Bulletin -HR Plug-in iming Relays pecifications -HR, - HR, -HRV -HRP -HRC -HRM -HRF -HRY -HRQ Electrical Ratings Pilot Duty Rating NEMA B -HR (ransistor s) hermal Current (I th ) A ma @ V DC max. V AC A Make V AC A V AC A Break V AC. A Hp at V / Hp (. kw) / Hp (. kw) / Hp (. kw) / Hp (. kw) / Hp (. kw) Hp at V / Hp (. kw) Resistive Load A at V AC/V DC Inductive Load AC- @ V AC, A/DC- @ V DC,. A Accuracy of Operating ime ±. % F max. (±. % ± ms max. in a range of. s) etting Error ± % F ± ms (he value is ± % F + ms to - ms max. when the C or D mode signal of the -HRVs are OFF.) Influence of Voltage ±. % F max. (±. % ± ms max. in a range of. s) Influence of emperature ± % F max. (± % ± ms max. in a range of. s) Permissible Leakage Current Consumption -HR, -HR -HRV -HRP, -HRC -HRM -HRF -HRY -HRQ -HR V AC, ON. VA. VA. VA. VA VA VA. VA V AC, OFF. VA. VA. VA. VA VA VA. VA V DC, ON. W. W. W. W. W. W. W V DC, OFF. W. W. W. W. W. W. W Design pecifications V AC (V AC for -HR), / Hz for min (contact to frame) V AC (V AC for -HR), / Hz for min (between control output terminals and operating circuit) Dielectric trength V AC, / Hz for min (pole-to-pole) V AC, / Hz for min (between contacts not located next to each other) V AC, / Hz for min (contact to coil) Mechanical Vibration Resistance Malfunction: Hz with. mm double amplitude each in three directions for ten minutes each hock Resistance Malfunction: m/s ( G) Environmental m/s ( G) Noise Immunity ±. kv for ±V DC ±V for V DC tatic Immunity Malfunction: kv Ambient emperature Operating: - C (with no icing) torage: - C (with no icing) Ambient Humidity Operating: % Construction Life Rxpectancy (Min. Operations) Mechanical:. (under no load at operations/h) Electrical: ( A at V AC, resistive load at operations/h) m/s ( G) m/s ( G) ±kv for V DC Mech: Electrical: (EMI) EN- Emission Enclosure:EN Group class A Emission AC Mains: EN Group class A (EM) EN- Immunity ED:EN--: kv contact discharge (level ) kv air discharge (level ) EMC Immunity RF-interference from AM Radio Waves: ENV: V/m ( MHz GHz) (level ) Immunity RF-interference from Pulse-modulated Radio Waves:ENV: V/m ( ± MHz) (level ) Immunity Conducted Disturbance:ENV: V (. MHz) (level ) Immunity Burst:EN--: kv power-line (level ) Immunity urge:en-- kv I/O signal-line (level ) kv line to line kv line to ground (level ) Degree of Protection IP (panel surface) Weight Approx. g Certifications CA Certified (File No. ), UL Recognized (File No. E Guide No. NRN), CE Marked, C-ick Marked tandards UL, CA C. No., EN -, EN --, -- m/s ( G) ±. kv for ±V DC Publication A-CAA-EN-P -
Bulletin -HR Plug-in iming Relays iming Module Examples imer Functions -HR Multifunction imer indicator (orange) (Lit when energized) indicator (green) (Flashes when imer operates; lit when imer stops operating) Operating mode display window Operating mode selector elect a mode from: A, B, B, C, D, and E (-HR, -HRV, and HR ) A, E, B, and J (-HR, -HRP, and -HR) cale range display windows ime Range selector (select one from.,,, and at full scale.) ime setting knob (set time) ime unit display window ime unit selector (select one from sec, min, hrs, and h) -HRC -HRM On-Delay imer indicator (orange) (Lit when energized) indicator (green) (Flashes when imer operates; lit when imer stops operating) cale range display windows ime Range selector (select one from.,,, and at full scale.) ime setting knob (set time) ime unit display window ime unit selector (select one from sec, min, hrs, and h) -HRF win imer OFF indicator (green) Lit when the output is OFF. ON indicator (orange) Lit when the output is ON. cale range display windows ime range selector (select one from.,,, and at full scale.) OFF-time unit display OFF-time unit selector (select one from sec. s, min., and hrs ON-time setting knob (with orange pointer) For ON-time setting OFF-time setting knob (with green pointer) For OFF-time setting ON-time unit display ON-time unit selector (select one from sec. s, min., and hrs -HRY tar-delta imer tar operation indicator (green) Delta operation indicator (orange) cale range display windows ime unit display (sec. is fixed) ime setting knob (for setting star operation time) -HRQ rue Off-Delay imer tar operation time range selector (select one from,, and at full scale.) tar-delta transfer time unit display tar-delta transfer time selector (select one from. s,. s,. s, and. s) cale range display windows indicator (red) ime setting knob (for setting OFF-delay time) ime range selector (select one from.,.,, and at full scale.) - rue OFF-Delay time unit display Publication A-CAA-EN-P
Bulletin -HR Plug-in iming Relays rigger ignal Examples pecifications for, Gate, Reset ignal (Cat. Nos. -HR, -HR, -HRV, -HRQR), Reset, and Gate signals are typically contact closures or signals from a solid-state sensor. (R) Reset ignal he reset signal is not required for normal operation. Reset can be accomplished by removing power from the timing relay. o reset the timer without removing power, a signal must be applied which resets the timing cycle and returns the output contacts to their shelf state. he reset signal will override both the start signal and gate signal. he reset signal can be either momentary or maintained. (G) Gate ignal he gate signal is not required for normal operation. he gate signal provides a pause or retentive timing function. When the gate signal is applied the timing cycle is momentarily interrupted. When the signal is removed, the timing cycle resumes timing at the point the cycle was interrupted and will continue timing until the time delay is completed or the gate signal is re-applied. to iming Relay Reset ignal iming Cycle iming Relay to iming Relay Gate (pause) iming Cycle iming Relay t < t t t t +t = Contact ignal Cat. Nos. -HR, -HR, -HRQR Contact closure provides signal to timer. A low energy signal is generated by the -HR timing relay. For optimum reliability, use contacts designed for low energy switching (V, ma) (Bul. F-X V, -X V). No external voltage should be connected to the contact signal. R G v, ma Contact ignal Cat. No. -HRV For use in applications where it is not possible to use contacts designed for low energy switching. Contact closure provides signal to timer. A signal is generated by the -HR timing relay, and is the same potential as the supply voltage of the timing relay. No external voltage should be connected to contact signal. -HRVU supply voltage:...v AC,...V DC / -HRVA supply voltage:...v AC,...V DC. olid-tate ignal Cat. Nos. -HR, -HR iming relay is suitable for use with a -wire NPN...V DC sensor. upply voltage potential of sensor must be the same as the supply voltage potential of the timing relay. Permissible off-state leakage current from sensor:. ma max. U U ( ) ( + ) +...V DC COM.mA R G COM ( ) (+)...V DC olid-tate ignal Cat. No. -HRV iming relay is suitable for use with a -wire NPN or PNP...V DC sensor. upply voltage potential of sensor must be the same as the supply voltage potential of the timing relay. Permissible off-state leakage current from sensor:. ma max. +...V DC COM +... V DC COM COM( ) COM( ) PNP Wiring Diagram (+)...V DC NPN Wiring Diagram (+)...V DC Publication A-CAA-EN-P -
Bulletin -HNC Plug-in iming Relays rigger ignal Examples/ iming Charts Circuit Impedance -OFF Reset ignal Duration ignal Options ignal pecifications Circuit impedance can be used to calculate the maximum wiring distance from the signal switch to the timing relay, for example. Permissible signal-on impedance: kω max. Permissible signal-off impedance: kω min. Min. power-off time:. s, Reset Voltage: % max. of rated voltage Min. pulse width:. s -HR -HR -HRV -HRQR X X X NA Reset X X NA X Gate X X NA NA Nomenclature iming Charts Mode A ON-Delay a. Needs continuous input power applied. b. iming is initiated by the leading edge of the start signal. c. Contacts change state after timing is complete. d. Additional start signals during timing don't reset timing or contacts. e. When the input power is removed contacts return to shelf state. LED Mode B Repeat Cycle, Off b. iming is initiated by the leading edge of the start signal. Additional start signals during timing do not reset timing or contacts. c. For the first time period the contacts remain in their shelf state. When that time period is complete contacts change state for the same time period (time on = time off). d. his cycle repeats itself until input power is removed or reset signal is applied. When the input power is removed or reset signal is applied contacts return to the shelf state. LED b. iming is initiated by the leading edge of the start signal. Additional start signals during timing do not reset timing or contacts. c. For the first time period the contacts change state. When that time period is complete contacts return to the shelf state for the same time period (time on = time off). d. his cycle repeats itself until input power is removed or reset signal is applied. When the input power is removed or reset signal is applied contacts return to the shelf state. LED - Publication A-CAA-EN-P
Bulletin -HNC Plug-in iming Relays iming Charts Mode C Watchdog monitor (rigger = ignal On/Off) b. Contacts change state immediately when start signal is applied or when start signal is removed (only if timing cycle was complete). c. iming is initiated at the leading edge of the start signal. After the first timing cycle is complete, timing is initiated by the trailing edge of the start signal. d. At the end of the time period contacts return to the shelf state. e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state. f. When the input power is removed contacts return to the shelf state. t< t LED Mode D Off-Delay (rigger=ignal Off) b. Contacts change state immediately when start signal is applied. c. iming is initiated by the trailing edge of the start signal. d. At the end of the time period contacts return to the shelf state. e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state. f. When the input power is removed contacts return to the shelf state. t t< LED Mode E One-hot (rigger=ignal On) -HR, -HRV, and -HR b. iming is initiated by the leading edge of the start signal. c. Contacts change state immediately when start signal is applied. d. At the end of the time period contacts return to the shelf state. e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state. f. When the input power is removed contacts return to shelf state. t t< LED Mode E One-hot (rigger = On) -HR, -HRP, and -HR b. iming is initiated when the input power is applied. c. At the end of the time period contacts return to the shelf state. d. Relay timing is reset when input power is removed. t< imed imed LED Publication A-CAA-EN-P -
Bulletin -HNC Plug-in iming Relays iming Charts Mode J Delayed One-hot (rigger= On) b. No start signal applied. c. iming is initiated when input power is applied. c. Contacts change state after the timing for a fixed time of s +/-.s d. At the end of the sec period the contacts return to the shelf state. e. When the input power is removed contacts return to the shelf state. s ±.s s ±.s LED LED Mode tar-delta b. No start signal required. iming is initiated when input power is applied. c. tar ouput contact changes state when input power is applied. d. After timing is complete star output contact returns to the shelf state then both the star & delta contacts remain in shelf states until transfer time setting is complete. e. Delta output contact changes state after transfer time is complete. f. Instantaneous contact changes state when input power is applied. g. All contacts return to the shelf state when input power is removed. t t t t Instantaneous -, LED -, LED -, LED -, LED Mode rue Off-Delay (rigger= Off) a. Continuous input power is NO required. b. No start signal applied. c. Contacts change state immediately when input power is applied. d. iming starts when input power is removed. e. At the end of the time period contacts return to the shelf state. f. Relay timing is reset when input power is reapplied while the relay is timing. Contacts remain in energized state. t t< Relay On LED Relay On LED - Publication A-CAA-EN-P