Timing Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start

Similar documents
Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Bulletin 700-HX Multifunction Digital Timing Relay

Multi-function 11 pin Plug-in for use with 90 series sockets

Solid-state Timer H3DS

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

87 Series - Modular timers 5-8 A. Features

Solid-state Twin Timer

Solid-state Timer H3DE

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Multi-function 11 pin Plug-in for use with 90 series sockets

Section. Timers. Selection Guide... G-2. Timing Diagrams Overview... G-4. W G RTE Series Analog Timers... G-8 Accessories... G-11 Dimensions...

Multifunction Devices CIM1, CIM12, CIM13, CIM14

02/11/2015

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

Solid-state Timer H3DE

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

83 SERIES. 83 Series - Modular timers A. Features

MULTI-RANGE ANALOG TIMER

Solid-state Timer H3DS

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291

Solid-state Timer H3DS

PART NUMBERING SYSTEM

Multi-voltage Multi-function. Wiring diagram (without control signal)

Contents H3DS. DIN Track Mounted, Standard 17.5-mm Width Timer Range. Broad Line-up of H3DS Series. Solid-state Timer. Common to ALL Timers H3DS-X

PART NUMBERING SYSTEM

83 Series - Modular timers 16 A. Features

22/10/2012

Chronos 2 electronic timers mm

Multi Function Timer with Free power, Compact size W38 H42mm

Modular timers A

Switching & Controls Timers

17.5mm Chronos 2 Timers

02/11/2015

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Programmable Digital Timer

Chronos 2 electronic timers - Plug-in 8-pin (35 mm)

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Assembly of Contacts 700-FS A 3 A U23. Function Contact Outputs Time Ranges Supply Voltages All functions: Z12 12V DC

CompoBus/D-type Digital Controller

Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)

GT3D Series Digital Timers

NPN PNP NPN PNP NPN PNP

Railway applications. Relays Time relays Monitoring relays Sockets

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Self-powered Counter

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

DIN48 SIZE MULTI-RANGE ANALOG TIMER. Protective construction. Time range IP65 IP50 IP selectable ranges 1s to 500h IP50 IP65 IP50

DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

MasterINTERFACE 39 Series - Relay interface modules

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

VAC V AC/DC, +/-10%, 45-65Hz Hz VDC max 1W ; 24VAC 2.5VA, 48VAC 4.46VA ; 110VAC 1.76 VA ; 220VAC 2.53 VA

MasterINTERFACE 39 Series - Relay interface modules

Timers/Time Switches/Counters/Hour Meters

87 Series Modular Timers 5-8 A

RENF22R2MMW Zelio Timer Relay - Modular

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Monitoring voltages of 3-phase 4 wires with a single unit

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

WHEN A PLC IS TOO MUCH, AND SPACE FOR

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

DIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

08/07/2015

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Model Number Structure

Bulletin 700-RTC Solid-State Timing Relay

T ime Delay Relays General information

onlinecomponents.com

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Programmable Digital Timer

Model Number Structure

GEMINI PRESETTABLE DUAL RATE INDICATOR WITH RATIO (A/B)

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

62 Series - Power relays 16 A. Features / /

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

40 Series - Miniature P.C.B. Relays A

Solid-state Timer. Operation/resetting system Time-limit contact Time ranges Model

Analog Timer TTL Series

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03

Transcription:

Bulletin -HR Plug-in iming Relays Product election/catalog Number Explanation Bulletin ON-Delay iming Relays ocket or Panel Mounted iming Range From. s h -pin base for socket cat. nos. -HN, -HN, -HN rigger: on Reset: off iming Mode upply Voltage rigger Options Reset Options s Cat. No. ON-Delay (A) V AC/DC V AC V DC On Off V AC On Off PD imed + Instantaneous Contact DPD DPD PD imed + Instantaneous Contact -HRCU -HRMU -HRMA -HRCA iming mode description A ON- Delay D OFF- Delay E One hot B Repeat Cycle OFF- B Repeat Cycle ON- C ignal ON/OFF- Delay J One hot Bulletin -HRF Repeat Cycle iming Relays ocket or Panel Mounted Independently adjustable on- and off-time -Pin base for socket cat. nos. -HN, -HN, and -HN DPD contact outputs rigger: on Reset: off Cat. No. Explanation HRF a imer ype Repeat cycle with adjustable ON/OFF times b Function Repeat cycle with OFF start Repeat cycle with ON start HRF D Z a b c d e c Contact DPD A d Z ime Range Z D. s hr U e upply Voltage V AC, / Hz V AC, / Hz; V DC V DC V DC Publication A-CAA-EN-P -

Accessories Bulletin -HR Plug-in iming Relays Accessories Pkg. Qty. Cat. No. Cat. No. -HN crew erminal ube Base ocket Panel or DIN Rail Mounting; Guarded erminal Construction. -Pin for use with Bulletin -HR and -HX timing relays. -HN crew erminal ube Base ocket Panel or DIN Rail Mounting; Open tyle Construction. - Pin for use with Bulletin -HR and -HX timing relays. No retainer clip required. -HN Cat. No. -HN crew erminal ube Base ockets Panel or DIN Rail Mounting; Guarded erminal Construction. -pin for use with PD -HA relays. -HN Cat. No. -HN crew erminal ube Base ockets Panel or DIN Rail Mounting; Open tyle erminal Construction. -pin for use with PD -HA relays. No retainer clip required. -HN Cat. No. -HN DIN (#) symmetrical hat rail x. x m -DR Cat. No. -DR pecialty ocket -pin backwired socket with solder terminals for use with -HR timing relays. Order or multiples of. -HN Cat. No. -HN pecialty ocket -pin back-wired socket with solder terminals for use with Bulletin -HR timing relays. -HN Cat. No. -HN Publication A-CAA-EN-P -

Bulletin -HR Plug-in iming Relays Accessories Pkg. Quantity Cat. No. Cat. No. -HN Frame Adapter For flush or door mounting of all Bulletin -HR and -HX timers. -HN Retainer Clip for Cat. Nos. -HN and -HN ockets with all -HR iming Relays ecures timer in socket. -HN Note: Not required for installation ample Retainer Clips Cat. No. -HN Protective Cover Helps prevent tampering of timing and mode settings. Provides a degree of protection against water and dirt from entering the front of the relay. For use with all Bulletin - HRs and -HX timing relays. Pre-Printed Identification ags contains sheets of pre-printed and blank tags. Each sheet contains sets of the markings CR CR, R R, M M, F, R,, and blank tags. ags are peel-off with sticky backing for easy placement on relays. -HN -N Blank Identification ags contains sheets of blank identification tags for customer specialized printing. Each sheet contains blank tags. ags are peel-off with sticky backing for easy placement on relays. -N Bulletin -HR Multi-function, Multi-Range Dial iming Relay, ocket, Retainer Clip Reference Chart imer ype -HR, -HR, -HRV, -HRQR -HR, -HR, -HRP, -HRC, -HRM, -HRF, -HRY, -HRQN Design of these sockets holds the timing relays securely and does not require retainer clips. pins. + pins. ocket Cat. No. Retainer Clip Cat. No. -HN -HN -HN Not Required -HN Not Applicable -HN -HN(ee note above) -HN Not Applicable -HN Not Required - Publication A-CAA-EN-P

Bulletin -HR Plug-in iming Relays pecifications -HR, - HR, -HRV -HRP -HRC -HRM -HRF -HRY -HRQ Electrical Ratings Pilot Duty Rating NEMA B -HR (ransistor s) hermal Current (I th ) A ma @ V DC max. V AC A Make V AC A V AC A Break V AC. A Hp at V / Hp (. kw) / Hp (. kw) / Hp (. kw) / Hp (. kw) / Hp (. kw) Hp at V / Hp (. kw) Resistive Load A at V AC/V DC Inductive Load AC- @ V AC, A/DC- @ V DC,. A Accuracy of Operating ime ±. % F max. (±. % ± ms max. in a range of. s) etting Error ± % F ± ms (he value is ± % F + ms to - ms max. when the C or D mode signal of the -HRVs are OFF.) Influence of Voltage ±. % F max. (±. % ± ms max. in a range of. s) Influence of emperature ± % F max. (± % ± ms max. in a range of. s) Permissible Leakage Current Consumption -HR, -HR -HRV -HRP, -HRC -HRM -HRF -HRY -HRQ -HR V AC, ON. VA. VA. VA. VA VA VA. VA V AC, OFF. VA. VA. VA. VA VA VA. VA V DC, ON. W. W. W. W. W. W. W V DC, OFF. W. W. W. W. W. W. W Design pecifications V AC (V AC for -HR), / Hz for min (contact to frame) V AC (V AC for -HR), / Hz for min (between control output terminals and operating circuit) Dielectric trength V AC, / Hz for min (pole-to-pole) V AC, / Hz for min (between contacts not located next to each other) V AC, / Hz for min (contact to coil) Mechanical Vibration Resistance Malfunction: Hz with. mm double amplitude each in three directions for ten minutes each hock Resistance Malfunction: m/s ( G) Environmental m/s ( G) Noise Immunity ±. kv for ±V DC ±V for V DC tatic Immunity Malfunction: kv Ambient emperature Operating: - C (with no icing) torage: - C (with no icing) Ambient Humidity Operating: % Construction Life Rxpectancy (Min. Operations) Mechanical:. (under no load at operations/h) Electrical: ( A at V AC, resistive load at operations/h) m/s ( G) m/s ( G) ±kv for V DC Mech: Electrical: (EMI) EN- Emission Enclosure:EN Group class A Emission AC Mains: EN Group class A (EM) EN- Immunity ED:EN--: kv contact discharge (level ) kv air discharge (level ) EMC Immunity RF-interference from AM Radio Waves: ENV: V/m ( MHz GHz) (level ) Immunity RF-interference from Pulse-modulated Radio Waves:ENV: V/m ( ± MHz) (level ) Immunity Conducted Disturbance:ENV: V (. MHz) (level ) Immunity Burst:EN--: kv power-line (level ) Immunity urge:en-- kv I/O signal-line (level ) kv line to line kv line to ground (level ) Degree of Protection IP (panel surface) Weight Approx. g Certifications CA Certified (File No. ), UL Recognized (File No. E Guide No. NRN), CE Marked, C-ick Marked tandards UL, CA C. No., EN -, EN --, -- m/s ( G) ±. kv for ±V DC Publication A-CAA-EN-P -

Bulletin -HR Plug-in iming Relays iming Module Examples imer Functions -HR Multifunction imer indicator (orange) (Lit when energized) indicator (green) (Flashes when imer operates; lit when imer stops operating) Operating mode display window Operating mode selector elect a mode from: A, B, B, C, D, and E (-HR, -HRV, and HR ) A, E, B, and J (-HR, -HRP, and -HR) cale range display windows ime Range selector (select one from.,,, and at full scale.) ime setting knob (set time) ime unit display window ime unit selector (select one from sec, min, hrs, and h) -HRC -HRM On-Delay imer indicator (orange) (Lit when energized) indicator (green) (Flashes when imer operates; lit when imer stops operating) cale range display windows ime Range selector (select one from.,,, and at full scale.) ime setting knob (set time) ime unit display window ime unit selector (select one from sec, min, hrs, and h) -HRF win imer OFF indicator (green) Lit when the output is OFF. ON indicator (orange) Lit when the output is ON. cale range display windows ime range selector (select one from.,,, and at full scale.) OFF-time unit display OFF-time unit selector (select one from sec. s, min., and hrs ON-time setting knob (with orange pointer) For ON-time setting OFF-time setting knob (with green pointer) For OFF-time setting ON-time unit display ON-time unit selector (select one from sec. s, min., and hrs -HRY tar-delta imer tar operation indicator (green) Delta operation indicator (orange) cale range display windows ime unit display (sec. is fixed) ime setting knob (for setting star operation time) -HRQ rue Off-Delay imer tar operation time range selector (select one from,, and at full scale.) tar-delta transfer time unit display tar-delta transfer time selector (select one from. s,. s,. s, and. s) cale range display windows indicator (red) ime setting knob (for setting OFF-delay time) ime range selector (select one from.,.,, and at full scale.) - rue OFF-Delay time unit display Publication A-CAA-EN-P

Bulletin -HR Plug-in iming Relays rigger ignal Examples pecifications for, Gate, Reset ignal (Cat. Nos. -HR, -HR, -HRV, -HRQR), Reset, and Gate signals are typically contact closures or signals from a solid-state sensor. (R) Reset ignal he reset signal is not required for normal operation. Reset can be accomplished by removing power from the timing relay. o reset the timer without removing power, a signal must be applied which resets the timing cycle and returns the output contacts to their shelf state. he reset signal will override both the start signal and gate signal. he reset signal can be either momentary or maintained. (G) Gate ignal he gate signal is not required for normal operation. he gate signal provides a pause or retentive timing function. When the gate signal is applied the timing cycle is momentarily interrupted. When the signal is removed, the timing cycle resumes timing at the point the cycle was interrupted and will continue timing until the time delay is completed or the gate signal is re-applied. to iming Relay Reset ignal iming Cycle iming Relay to iming Relay Gate (pause) iming Cycle iming Relay t < t t t t +t = Contact ignal Cat. Nos. -HR, -HR, -HRQR Contact closure provides signal to timer. A low energy signal is generated by the -HR timing relay. For optimum reliability, use contacts designed for low energy switching (V, ma) (Bul. F-X V, -X V). No external voltage should be connected to the contact signal. R G v, ma Contact ignal Cat. No. -HRV For use in applications where it is not possible to use contacts designed for low energy switching. Contact closure provides signal to timer. A signal is generated by the -HR timing relay, and is the same potential as the supply voltage of the timing relay. No external voltage should be connected to contact signal. -HRVU supply voltage:...v AC,...V DC / -HRVA supply voltage:...v AC,...V DC. olid-tate ignal Cat. Nos. -HR, -HR iming relay is suitable for use with a -wire NPN...V DC sensor. upply voltage potential of sensor must be the same as the supply voltage potential of the timing relay. Permissible off-state leakage current from sensor:. ma max. U U ( ) ( + ) +...V DC COM.mA R G COM ( ) (+)...V DC olid-tate ignal Cat. No. -HRV iming relay is suitable for use with a -wire NPN or PNP...V DC sensor. upply voltage potential of sensor must be the same as the supply voltage potential of the timing relay. Permissible off-state leakage current from sensor:. ma max. +...V DC COM +... V DC COM COM( ) COM( ) PNP Wiring Diagram (+)...V DC NPN Wiring Diagram (+)...V DC Publication A-CAA-EN-P -

Bulletin -HNC Plug-in iming Relays rigger ignal Examples/ iming Charts Circuit Impedance -OFF Reset ignal Duration ignal Options ignal pecifications Circuit impedance can be used to calculate the maximum wiring distance from the signal switch to the timing relay, for example. Permissible signal-on impedance: kω max. Permissible signal-off impedance: kω min. Min. power-off time:. s, Reset Voltage: % max. of rated voltage Min. pulse width:. s -HR -HR -HRV -HRQR X X X NA Reset X X NA X Gate X X NA NA Nomenclature iming Charts Mode A ON-Delay a. Needs continuous input power applied. b. iming is initiated by the leading edge of the start signal. c. Contacts change state after timing is complete. d. Additional start signals during timing don't reset timing or contacts. e. When the input power is removed contacts return to shelf state. LED Mode B Repeat Cycle, Off b. iming is initiated by the leading edge of the start signal. Additional start signals during timing do not reset timing or contacts. c. For the first time period the contacts remain in their shelf state. When that time period is complete contacts change state for the same time period (time on = time off). d. his cycle repeats itself until input power is removed or reset signal is applied. When the input power is removed or reset signal is applied contacts return to the shelf state. LED b. iming is initiated by the leading edge of the start signal. Additional start signals during timing do not reset timing or contacts. c. For the first time period the contacts change state. When that time period is complete contacts return to the shelf state for the same time period (time on = time off). d. his cycle repeats itself until input power is removed or reset signal is applied. When the input power is removed or reset signal is applied contacts return to the shelf state. LED - Publication A-CAA-EN-P

Bulletin -HNC Plug-in iming Relays iming Charts Mode C Watchdog monitor (rigger = ignal On/Off) b. Contacts change state immediately when start signal is applied or when start signal is removed (only if timing cycle was complete). c. iming is initiated at the leading edge of the start signal. After the first timing cycle is complete, timing is initiated by the trailing edge of the start signal. d. At the end of the time period contacts return to the shelf state. e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state. f. When the input power is removed contacts return to the shelf state. t< t LED Mode D Off-Delay (rigger=ignal Off) b. Contacts change state immediately when start signal is applied. c. iming is initiated by the trailing edge of the start signal. d. At the end of the time period contacts return to the shelf state. e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state. f. When the input power is removed contacts return to the shelf state. t t< LED Mode E One-hot (rigger=ignal On) -HR, -HRV, and -HR b. iming is initiated by the leading edge of the start signal. c. Contacts change state immediately when start signal is applied. d. At the end of the time period contacts return to the shelf state. e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state. f. When the input power is removed contacts return to shelf state. t t< LED Mode E One-hot (rigger = On) -HR, -HRP, and -HR b. iming is initiated when the input power is applied. c. At the end of the time period contacts return to the shelf state. d. Relay timing is reset when input power is removed. t< imed imed LED Publication A-CAA-EN-P -

Bulletin -HNC Plug-in iming Relays iming Charts Mode J Delayed One-hot (rigger= On) b. No start signal applied. c. iming is initiated when input power is applied. c. Contacts change state after the timing for a fixed time of s +/-.s d. At the end of the sec period the contacts return to the shelf state. e. When the input power is removed contacts return to the shelf state. s ±.s s ±.s LED LED Mode tar-delta b. No start signal required. iming is initiated when input power is applied. c. tar ouput contact changes state when input power is applied. d. After timing is complete star output contact returns to the shelf state then both the star & delta contacts remain in shelf states until transfer time setting is complete. e. Delta output contact changes state after transfer time is complete. f. Instantaneous contact changes state when input power is applied. g. All contacts return to the shelf state when input power is removed. t t t t Instantaneous -, LED -, LED -, LED -, LED Mode rue Off-Delay (rigger= Off) a. Continuous input power is NO required. b. No start signal applied. c. Contacts change state immediately when input power is applied. d. iming starts when input power is removed. e. At the end of the time period contacts return to the shelf state. f. Relay timing is reset when input power is reapplied while the relay is timing. Contacts remain in energized state. t t< Relay On LED Relay On LED - Publication A-CAA-EN-P