Installation Guide Index

Similar documents
Installation Guide for PermaSnap Coping & PermaSnap Plus Coping

Installation Guide for PermaSnap Plus Coping

PROVEN DEPENDABLE SUSTAINABLE

DMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988

DESIGNER SERIES GUTTER SYSTEM INSTALLATION INSTRUCTIONS

Paraguard Roof Perimeter Systems ANSI/SPRI ES-1 Test Reports UL. Classified Products

SLATE & SHINGLE INSTALLATION

Perimeter Edge Metal Brochure (COMGN296) Updated: 7/18

DW HORIZONTAL INSTALLATION

400 SERIES VERTICAL INSTALLATION

SECTION SHEET METAL FLASHING AND TRIM

MAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.

Dura-Lock Roof System

HOUSE PARTS PACKED IN HOUSE BOX PARTS IN PLASTIC BAG (HARDWARE) PARTS IN SMALL PLASTIC BAG (FLOOR CLIPS) PARTS PACKED IN BUNDLE

900 SERIES WALL PANELS

KS SERIES - VERTICAL INSTALLATION

TABLE OF CONTENTS A-1

Locker Pedestal Installation Instructions

Parts list continues on Page 2 HOUSE PARTS PACKED IN HOUSE BOX PARTS IN SMALL PLASTIC BAG (HARDWARE) POST PARTS PACKED IN THIS BOX (LARGE PLASTIC BAG)

Construction details: Master-C type profiles and joints:

DW VERTICAL INSTALLATION

Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes

LUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February

WALL MOUNT LOCKER ASSEMBLY. 208 Chestnut St, Reading, PA (610)

KS42 MF SERIES - HORIZONTAL INSTALLATION


COMPACT DECK. Compact Deck Project Plan #850 Sheet 1 of Riverside Dr., Suite 212 Metairie, LA SouthernPine.com SouthernPineDecks.

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

METALWORKS Linear (Interior & Exterior Applications)

#11179 Wellington ARBOR

SINGLE PIECE MASONRY HANGERS

IMPORTANT -- SPECIAL INSTALLATION INSTRUCTIONS

TIOGA Table of Contents

4 1/2" [114.3mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

METALWORKS Linear (Interior & Exterior Applications)

Installation Instructions for. Before You Begin TOOLS REQUIRED

Horizontal Cable Systems

Assembly Instructions 10 X 10 Aluminum Roof Support

Post & Rail. Includes: Crossbuck, 2-Rail, 3-Rail and 4-Rail POST SUPPORT OPTIONS

CARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)

Oxford Stalls Installation Instructions

FlexLoc. Technical/Installation Information

MobileTrak5 Installation Instructions

HANDRAIL HEIGHT PER LOCAL CODE AUTORITY

Please read these instructions thoroughly prior to beginning the Acrovyn Z-Clip Wall Panel installation!

METALWORKS Concealed. Installation Instructions

ROOF FLASHING FEATURES & BENEFITS PRODUCT DESCRIPTION

TABLE OF CONTENTS A. PBR

CertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS. Fence Installation Guide 3', 4' & 6' High

Installation Guide. Capped Cellular PVC Fencing. Table of Contents. Storage and Handling Tools Needed Fence Layout and Locating Posts

Installation Guide 2016

Pilaster with J-Channel Back Plate

Siding Components. Installation Guide

THERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE)

PEDESTAL INSTALLATION. Guidelines for installing adjustable height pedestals

ROOFING APPLICATION STANDARD (RAS) No. 130

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

SPRINGLOK SPRINGLOK FLASHING SYSTEM PRODUCT BROCHURE ENGINEERED PRODUCT SYSTEMS

INSTALLATION PROCEDURE

OHearneAssociates.com

TECHNICAL BULLETIN. 7/2017 CertainTeed Corporation

Installation Instructions for. Handrail Component System

CRASH RAIL INSTALLATION HEIGHT

ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION

SunTrackerTwo Preparation

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET

ALUMINUM RAILING INSTALLATION INSTRUCTIONS. 1) Check Contents Of Packages: Verify that all parts have arrived and that they match the packing list.

Installation Guidelines

K.D. LOCKER ASSEMBLY INSTRUCTIONS

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01

Table of Contents Light Gauge Metal Roof & Wall Panels

Horizontal Cable Systems

ProSnap 100 STANDARD DETAILS

Shapes Siding. Perfection Shingles. Chalk Line

SHEET METAL FLASHING AND TRIM Christ on the Mountain

ALUMINUM RAILING INSTALLATION INSTRUCTIONS. 1) Check Contents Of Packages: Verify that all parts have arrived and that they match the packing list.

NOTE: Top section pole (Q) is packed INSIDE bottom section pole (S)

Turada Hardwood Shingles and Shakes Installation instructions

mila-wall (Series100) General Operating Instructions page 1 of 15

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

Track Rack. * Track Racks are not lockable

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

System 3000 specifications

CLWP6048. Classic Sign Family Wall Panel. Part Number / Specifications. 60" Wide x 48" High CHPL Panel Wall Mount. ISO / Perspective View.

Ekoroof LiteTile Dimensions

Fireball Fab Welded Baluster Insert Panel System Installation Instructions

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

Installation Instructions for Siding

INSTALLATION INSTRUCTIONS

Installation Manual SOLID CORE SIDING

ALL SEASON PATIO COVER

ELEVEN COLLABORATIVE. CONFERENCE TOPS Assembly Instructions

REGAL. Installation Manual

3 1/2" [88.9mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

INS TA L L AT I O N IN S T R U C T I O N S F O R BEF O R E YO U BE G I N TOOLS REQUIRED

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

Intex Engineered Pergola System Installation Instructions. NOTE: See Appendix for Foundation Requirements

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11

Transcription:

Installation Guide for FlintEdge Coping & Coping+ Straight Parapets 6" through Wide ANSI/SPRI ES-1 TESTE Also included: Installation Guides for Radius Parapets 6" through Wide Vaulted Parapets 6" through Wide Special Wall Conditions 6" through Wide Installation Guide Index General Information Coping iagrams Straight Parapet Installation Radius Parapet Installation Vaulted Parapet Installation Special Condition Installation CERTAINTEE ING 750 E. Swedesford Road - Valley Forge, PA 1948 - Phone: (800) 345-1145 www.certainteed.com

COPING IAGRAMS O NOT USE SEAANT AT JOINT SPICES FACE SIZES to 4-1/" POP-RIVETS SUPPIE PACE FASTENERS IN A PRE PUNCHE HOES. REFER TO STEP 1 ON BACK PAGE FOR MORE INFO. SPICE AN CIP FASTENERS, 1-1/" SS RING SHANK NAIS SUPPIE** COPING JOINT SPICE ANCHOR CIP *3/8" *3/4" ING MEMBRANE FACE SIZES 4-1/" up to 6" 1" min. PER SMACNA SPICE FASTENERS, 1-1/" SS RING SHANK NAIS SUPPIE** #9 x 1-1/" SS SCREW w/ NEOPRENE WASHER, TYP. of (4) 6" to less than 0" (Anchor Clip esign) Small wall and/or small face size detail *3/4" *3/8" FACE SIZES 6" to 1" 1" min. PER SMACNA CIP FASTENERS, 1-1/" SS RING SHANK NAIS SUPPIE** 0" or Greater (Anchor Clip esign) arge wall and/or large face size detail *IMENSION WI VARY WITH WITH VARIATION ** FOR SUBSTRATES OTHER THAN WOO, CONTACT WP HICKMAN FOR FASTENER RECOMMATIONS Clip = Wall + 3/8" Joint Splice = Wall + 5/8" Cap = Wall + 3/4"

STRAIGHT PARAPET INSTAATION A O NOT USE SEAANT AT JOINT SPICES POP-RIVET F or 1-1/" SS RING SHANK NAIS SUPPIE* B C (4) SCREWS PER CIP TOP E (1) NAI PER IN CORNER SUPPORT TOP H G () FASTENERS* PER CIP FOR FACE SIZES GREATER THAN 4-1/" * 1-1/" SS RING SHANK NAIS SUPPIE. CONTACT MANUFACTURER FOR FASTENERS IN NON-WOO SUBSTRATES. H () NAIS PER OUT CORNER SUPPORT FACE OUT CORNER IN CORNER A. Formed Coping Cap 10'-0" engths B. 6" Wide Concealed Joint Splice One (1) at Each Clip ocation C. 1" Wide Galv. Anchor Clip 6" < Wall Width < 17" Install @ 60" on center 17"< Wall Width < Install @ 40" on center. Corner Supports (Inside & Outside) Used to Support Outside and Inside Miters E. #9 x 1-1/" SS Screw w/ Neoprene Washer Four (4) Per Clip Top F. Splice Fasteners Pop-Rvets Supplied Two () Per Joint Splice if FACE is to 4-1/" 1-1/" SS Ring Shank Nails Supplied Two () Per Joint Splice if FACE is >4-1/" G. Clip Fasteners 1-1/" SS Ring Shank Nails Supplied Two () Per Clip if FACE is >4-1/" H. Corner Support Fasteners 1-1/" SS Ring Shank Nails Supplied Two () Per Outside Corner Support Face One (1) Per Inside Corner Support Top

HOOK FRONT SNAP BACK SPICE FASTENERS CENTER FASTENERS IN SOTTE HOE 60" O.C. OR 40" O.C. (AS REQUIRE) OUT CORNER IN CORNER STEP 4: Installing Coping Miters Hook the face of the coping miter over the outside face leg of the clips, rotate the coping miter over the top of the clips and snap the roof side leg by pressing down. TOP VIEW SCREW OR RIVET (BY INSTAER) SEAANT BY OTHERS TERM =3 1/4" - for wall widths 16" wide =9 1/4" - for wall widths > 16" and wide =custom for wall widths > wide STEP 1: Installing Anchor Clips at Corners & Along the Parapet For face sizes to 4-1/" pop-rivet splices to A clips through pre punched holes. ocate anchor clips as shown. Pull clips snugly against the outside face. Place four (4) screw fasteners in the top of the clip. For faces >4-1/" place two () ss ring shank nails in the clip face (outer holes). Position the joint splice over the center of the clip and install as shown. For faces >4-1/" place two () ss ring shank nails thru aligning holes. Joint splices should be installed at A clip locations. CIP NOT SHOWN STEP 5: Installing End Caps and End Terms Install end caps and end terms by hooking face and snapping back into place. End caps must be restrained from moving by securing the end cap to the clip using a stainless steel screw or rivet (by installer) through the roof side leg of the end cap. End terms should be restrained similarly if no fasteners are previously installed in the end term wall flange. COPING STRAIGHT ENGTH STEP : Installing Anchor Clips at Wall Ends Install the first anchor clip approximately " from the wall end as shown. Install the second anchor clip 4" on center from the wall end. (If end cap leg is other than 4" adjust clip placement accordingly.) OUT CORNER IN CORNER STEP 3: Installing Corner Support Clips Two () corner support clips are to be placed at all corners to support the cap. Secure clips using 1-1/" ss ring shank nails. Set each clip away from the corner approximately. COPING MITER HOOK FRONT SNAP BACK STEP 6: Installing Coping Straight engths Begin installing from the corners and ends working inward to the center. Allow a 1/4" gap between the coping sections for thermal expansion. Review lengths of all straight pieces prior to cutting to avoid creating relatively short sections of cap adjacent to full length sections. There should be an anchor clip and joint splice at least every 60" O.C. (40" O.C. when wall is 17"- wide) and at every joint. Every fifth 10-foot section of coping should be secured to the clip using a single stainless steel screw or rivet (same procedure as STEP 5) to isolate movement within a containment zone.

RAIUS PARAPET INSTAATION A O NOT USE SEAANT AT JOINT SPICES POP-RIVET F or 1-1/" SS RING SHANK NAI B (4) SCREWS PER CIP TOP C E (1) NAI PER IN CORNER SUPPORT TOP H F () FASTENERS* PER CIP FOR FACE SIZES GREATER THAN 4-1/" * 1-1/" SS RING SHANK NAIS SUPPIE. CONTACT MANUFACTURER FOR FASTENERS IN NON-WOO SUBSTRATES OUT CORNER RAIUS TO STRAIGHT H () NAIS PER OUT CORNER SUPPORT FACE IN CORNER RAIUS TO STRAIGHT A. Radius Coping Cap 60" engths Typ. (engths May Vary) B. 6" Wide Concealed Joint Splice One (1) at Each Clip ocation C. 1" or 6" Wide Galv. Steel Anchor Clip 6"< Wall Width <17" Install @ 60" on center 17"< Wall Width < Install @ 30" on center. Corner Supports (Inside & Outside) Used to Support Outside and Inside Corners E. #9 x 1-1/" SS Screw w/ Neoprene Washer Four (4) Per Clip Top F. Splice Fasteners Pop-Rvets Supplied Two () Per Joint Splice if FACE is to 4-1/" 1-1/" SS Ring Shank Nails Supplied Two () Per Joint Splice if FACE is >4-1/" G. Clip Fasteners 1-1/" SS Ring Shank Nails Supplied Two () Per Clip if FACE is >4-1/" H. Corner Support Fasteners 1-1/" SS Ring Shank Nails Supplied Two () Per Outside Corner Support Face One (1) Per Inside Corner Support Top

SPICE FASTENERS CENTER FASTENERS IN SOTTE HOE TOP VIEW 60" O.C. OR 40" O.C. (AS REQUIRE) OUT CORNER HOOK FRONT SNAP BACK SCREW OR RIVET (BY INSTAER) IN CORNER STEP 4: Installing Radius to Straight Coping Miters Hook the face of the coping miter over the outside face leg of the clips, rotate the coping miter over the top of the clips and snap the roof side leg by pressing down. TERM SEAANT BY INSTAER 60" O.C. (AS REQUIRE) =3 1/4" - for wall widths 16" wide =9 1/4" - for wall widths > 16" and wide =custom for wall widths > wide STEP 1: Installing Anchor Clips at Corners & Along the Parapet For face sizes to 4-1/" pop-rivet splices to A clips through pre punched holes. ocate anchor clips as shown. Pull clips snugly against the outside face. Place four (4) screw fasteners in the top of the clip. For faces >4-1/" place two () ss ring shank nails in the clip face (outer holes). Position the joint splice over the center of the clip and install as shown. For faces >4-1/" place two () ss ring shank nails thru aligning holes. Joint splices should be installed at A clip locations. CIP NOT SHOWN STEP 5: Installing End Caps and End Terms Install end caps and end terms by hooking face and snapping back into place. End caps must be restrained from moving by securing the end cap to the clip using a stainless steel screw or rivet (by installer) through the roof side leg of the end cap. End terms should be restrained similarly if no fasteners are previously installed in the end term wall flange. RAIUS COPING 1/4" OUT CORNER IN CORNER STEP : Installing Corner Support Clips Two () corner support clips are to be placed at all corners to support the cap. Secure clips using 1-1/" ss ring shank nails. Set each clip away from the corner approximately. TERMINATION " " 4" 4" STEP 3: Installing Anchor Clips at Wall Ends Install the first anchor clip approximately " from the wall end as shown. Install the second anchor clip 4" on center from the wall end. (If end cap leg is other than 4" adjust clip placement accordingly.) STEP 6: Installing Radius Coping engths Begin installing from the corners and ends working inward to the center. Allow a 1/4" gap between the coping sections for thermal expansion. Review lengths of all radius pieces prior to cutting to avoid creating relatively short sections of cap adjacent to full length sections. There should be an anchor clip and joint splice at least every 60" O.C. (clip spacing may vary) and at every joint. Every fifth 60" section of coping should be secured to the clip using a single stainless steel screw or rivet (same procedure as STEP 5) to isolate movement within a containment zone.

VAUTE PARAPET INSTAATION COPING ANCHOR CIP #9 x 1-1/" SS SCREW w/ NEOPRENE WASHER, TYP. OFFSET 1-1/" SS RING SHANK NAI Clip = Wall + 3/8" Cap = Wall + 1-1/4" Wall ING MEMBRANE A B (4) SCREWS PER CIP TOP C () NAIS PER CIP FACE IF FACE IS >4-1/" VAEY Vaulted to Flat Wall Transition Miter A. Vaulted Coping Cap 60" engths Typ. (engths May Vary) B. Galvanized Steel Anchor Clip 6" or 1" Wide at 60" On Center Typ. (Clip Spacing May Vary) C. #9 x 1-1/" SS Screw w/ Neoprene Washer Four (4) Per Clip Top. 1-1/" SS Ring Shank Nail Supplied Two () Per Clip Face if Face is >4-1/" Two () Per Outside Corner Support Face One (1) Per Inside Corner Support Top

APPY EVEN PRESSURE FACE VAUTE VAUTE FAT FAT STRAIGHT 60" (AS REQUIRE) PAN VIEW 60" STEP 1: Installing Anchor Clips at Valleys & Along the Parapet ocate anchor clips as shown. Pull clips snugly against the outside face. Place four (4) screw fasteners in the top of the clip with fasteners centered in slotted holes. Place two () ss ring shank nails in the clip face if face is >4-1/". O NOT place anchor clip at joint locations, see diagrams above to determine anchor clip locations. 7" SEE CIP SPACING BEOW =3 1/4" - for wall widths 16" wide =9 1/4" - for wall widths > 16" and wide =custom for wall widths > wide 19" " EEVATION VIEW 7" (CIP TO CIP) OFFSET " " TYPICA CIP SPACING 1/4" GAP 7" OFFSET TYPICA VAUT TO FAT MITER CIP BEOW 19" " FACE OF STEP 3: Installing Coping Miters Place miter over installed anchor clips at valleys. Hook the face on the straight side of the miter onto the clip. Rotate the miter over the top of the clip and snap the roof side leg by pressing down. Then apply even pressure to the vaulted legs of the miter until both legs are fully engaged on the clip. SCREW OR RIVET (BY INSTAER) TERM SEAANT BY INSTAER () CIPS UNER STEP 4: Installing End Caps and End Terms Install end caps and end terms by placing the cap in the correct location over the anchor clips. Apply even pressure on both legs of the cap until both legs are fully engaged on anchor clips. End caps must be restrained from moving by securing the end cap to the clip using a stainless steel screw or rivet (by installer) through the roof side leg of the end cap. End terms should be restrained similarly if no fasteners are previously installed in the end term wall flange. 1/4" 1/4" PAN VIEW PAN VIEW TERMINATION OFFSET OFFSET TOP OF VAUT 7" 7" 7" 19" EEVATION VIEW " 19" " EEVATION VIEW STEP : Installing Anchor Clips at Wall Ends Install the first anchor clip approximately " from the wall end as shown. Install the second anchor clip 19" on center from the wall end. O NOT place second clip at joint location. (If end cap leg is other than 30" adjust clip placement accordingly.) Install third anchor clip 7" from second as shown above. 7" EEVATION VIEW STEP 5: Installing Vaulted Coping engths Begin installing from the valleys and the lower most part of the vaults at the wall ends working toward the upper/top of the vault. Allow a 1/4" gap between the coping sections for thermal expansion. Review lengths of all vaulted pieces prior to cutting to avoid creating relatively short sections of cap adjacent to full length sections. There should be at least () two anchor clips under each coping cap (Clip spacing may vary). Every fifth 60" section of coping should be secured to the clip using a single stainless steel screw or rivet (same procedure as STEP 4) to isolate movement within a containment zone.

SPECIA CONITION INSTAATION CEATS ONY SHOW FOR CARITY. EXAMPE 1 CENTER CEATS UNER S 1 WIE 1 '1' '' EXAMPE " ININE TRANSITION NOTE: Instructions are for face leg and back leg offsets. STEPS: 1. Install cleat 1 " from offset, only if wide wall cap leg length is longer than 0".. Install cleats centered under cap ends. CORNER SUPPORTS '1' PIER TRANSITION NOTE: Instructions are for face leg and back leg offsets. STEPS: 1. Install cleat 1 only if '' is longer than 1". Eles use corner support as shown.. For '1' cleats and corner supports, see below. 3. Install cleats centered under cap ends. '1' > 1" '1' < 1" '' CORNER SUPPORTS 1 '' Install corner supports as shown in EXAMPE Install cleat as shown in EXAMPE 1 CORNER SUPPORTS 'Z' MITER NOTE: Instructions work for face leg on either side. '1' EXAMPE 1 1 '' STEPS: 1. Install cleat 1 only if '' is longer than 14".. Install cleats centered under cap ends. 3. Install appropriate corner supports in designated areas. EXAMPE '1' '' CORNER SUPPORTS PIER ININE TRANSITION NOTE: Instructions are for face leg and back leg offsets. STEPS: 1. Install cleat 1 only if '' is longer than 1". Else use corner support as shown.. For '1' procedures see table below. 3. Install cleats centered under cap ends. '1' > 1" '1' < 1" Install corner supports as shown in EXAMPE Install cleat as shown in EXAMPE 1