USB BACNET COMMUNICATION OPTION MANUAL

Similar documents
USB BACNET COMMUNICATION OPTION MANUAL

IF96014 BACnet COMMUNICATION PROTOCOL. BACnet Protocol Implementation Conformance Statement

Nemo D4-L+ BACNET COMMUNICATION PROTOCOL. BACnet Protocol Implementation Conformance Statement. Date: March, 30 th 2012 Vendor Name:

BACnet Protocol Implementation Conformance Statement

Electronic pressure-independent characterised control valve with energy monitoring

Sensor BACnet PICS. Contents. 1. Operating elements for addressing and parametrization 2 2. Protocol Implementation Conformance Statement - PICS 3

BAS Integration Manual

BACnet Protocol Implementation Conformance Statement

RF-RXS-B SonNet Wireless Receiver BACnet IP

Communicative heating and cooling controller, BACnet MS/TP UB200. Summary

BAC-IO9 BACnet MS/TP Input / Output Modules, Wall Mounted

SKDESC-xB Series Electronic Steam Controller

BACnet communication module for TCX2: AEX-BAC

BACnet Integration Manual

Electronic pressure-independent characterised control valve with energy monitoring

PIR Ready SE7200, SE7300 & SER7300 Series

Belimo Gateway MP to BACnet MS/TP - UK24BAC

EPC3000 Programmable Controller

PIR Ready VT72xx & VT(R) 73xx Series 24 Vac Fan Coil and Zoning Thermostats For Commercial and Lodging HVAC Applications

Ocean Controls KT-5221 Modbus IO Module

CALEC ST II BACnet MS/TP

SRC-110 Series Zone Controllers. BACnet MS/TP. Product sheet CT2.143 SRC-110-BAC

Gas Fired Humidifier SKG Series

BACnet communication module for TCX2: AEX-BAC

BACnet- MS/TP COMMUNICATION V

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

SPECIFICATION. Online UPS 3000VA

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

BACnet PTEC Controller VAV with CO2 Monitoring, Parallel Fan and AOV or Floating Point Heating, Application 6682

MINI and MIX Series I/O modules

SKE Series Steam Humidifier

IP I/O Communication Module Specification and Installation Instructions

BACnet PTEC Controller Dual Duct 2 AVS - Constant Volume with Two Inlet Sensors and Optional Reheat, Application 6665

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Modbus communication module for TCX2: AEX-MOD

DTS BACnet MSTP Map Version 3.2U TABLE OF CONTENTS

I-2533CS series User Manual

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

DEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description

R&D TECHNICAL SPECIFI

JBUS/MODBUS communication card

B850 Boiler House Energy Monitor

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

Harris IRT Enterprises, Inc. Digital Resistance Tester Model A

USER MANUAL Z-10-D-OUT. Via Austria, PADOVA ITALY. Tel Fax

SAFETY PRECAUTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

B850 Boiler House Energy Monitor

EVCB14NIT4X. BACnet Communication Module User Guide

Bulletin B1243: RIBTW24B-BCAI RIBMNW24B-BCAI

TOSHIBA International Corp

UNIVERSAL INPUT RESISTANCE OUTPUT

InfraStruXure Manager v4.x Addendum: Building Management System Integration

OVEN INDUSTRIES, INC. Model 5C7-362

Brushless DC Motor Controller Specification Assemblies 025F0248

Fluke 125. Getting Started. Industrial ScopeMeter

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

WBT900. User s Manual. 900 MHz Wireless BACnet MSTP Radio. Page 1

ioselect Z-NET Z-4RTD 4 Channel RTD Input Module

DTAP. universal programmable controller. Универсален програмируем контролер

SC1000 DGPS USCG Dual Transmitter

Generator Speed Controller Model GSC 1

SMR5000F. User Manual. Smart Radio Data Repeater. Web Site: P.N.: Book 092

User Guide. EVCB14NIT4X-V410-BACnet Guide-EUA docx

CFO900 Series. User Manual. Audio/Data/Current Loop Mux/Demux CSX111, CSX123 & CSX222. CFO CSX series user manual, , rev003

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

MODBUS Protocol for CS101 network card family

UPS Communication Protocol

Looking For A High Power, Low Profile Power Supply? KEPCO. Has More Than One Way To Help Make Your Decision Easier! AN ISO 9001 COMPANY

ISOLATED AC/DC POWER SUPPLY

CAP6637A AC-DC Open Loop Converter

MULTISTACK The Modular Water Chiller

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

ADAM-4022T Serial Base Dual Loops PID Controller User s Manual

Sales and Engineering Data Sheet ED

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

HD 48V01T... HD 4977T...

The MP SERIES CONTROLLER. User s Manual. ISE, Inc.

USER MANUAL Z-3A0. Via Austria, PADOVA ITALY. Tel Fax

PROCESS & TEMPERATURE CONTROLLERS

SUBMITTAL MACH-ProWebSys

Tarocco Closed Loop Motor Controller

The first RADIO Communication Module designed for the weighing industry

USER MANUAL Z-8TC. Via Germania, Z.I. CAMIN PADOVA ITALY. Via Svizzera, Z.I. CAMIN PADOVA ITALY

SFP CWDM 1G 120km LC datasheet A-GEAR World Wide Manufacturing Product Specification

IP1 Datasheet PWM OUTPUT WITH SINGLE CHANNEL ADC MODULE FEATURES DESCRIPTION CONNECTOR DETAILS

JBus/Modbus Communication Card

10Gb/s DWDM Single-mode SFP+ Transceiver

SonoMeter 31 Energy Meters

Model 3102D 0-2 kv H.V. Power Supply

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Analog Module D1-15P User Manual

CONTROLS CS-I. MFDC/AC Inverter Weld Control

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

SX (400 V) System configuration

SX (690 V) System configuration

USER'S GUIDE. Vaisala HUMICAP Humidity and Temperature Transmitters HMW90 Series M211399EN-H

Infocal 9 Energy calculator

This Datasheet is for the IC693ALG220. Analog Voltage Input - 4 Channel.

Transcription:

USB BACNET COMMUNICATION OPTION MANUAL 175W - 750W SINGLE PHASE Series LV EMERGENCY LIGHTING CENTRAL INVERTER Myers Power Products, Inc. 44 South Commerce Way, Bethlehem, PA 18017 1-800-526-5088 (610) 868-3500 Fax: (610) 868-8686 Service: (610) 868-5400 www.myerspowerproducts.com 115194A LV BACnet Communication Option

Table of Contents SECTION 1... 2 BACnet Communication Option Board... 2 SECTION 2... 2 Description of Operation... 2 SECTION 3... 3 Settings... 3 Termination, Baudrate and MAC Address:... 3 Factory Defaults:... 3 SECTION 4... 4 Object Summary... 4 Object Summary (con t)... 5 SECTION 5... 6 Protocol Implementation... 6 BACnet Standardized Device Profile (Annex L)... 6 BACnet Interoperability Building Blocks Supported (Annex K)... 6 Segmentation Capability... 6 Standard Object Types Supported... 6 Data Link Layer Options... 6 Device Address Binding... 6 Networking Options... 6 Character Sets Supported... 6 1 115194A - LV BACnet Communication Option

SECTION 1 BACnet Communication Option Board The BACnet Communication Option Board for the Series LV Emergency Lighting Central Inverter has two internal connections, the RS485 communication bus, one external connection, a RS485 output connector, and dip jumpers that setup the baud rate and address. See Figure 1 for locations of the connections. COM RS485 P2 COM RS485 Figure 1 Outline of BACnet Communication Board. SECTION 2 Description of Operation EBI acts as a simple B-ASC server device. It supports a total of 112 Analog Input (AI), 67 Binary Input (BI) and 3 File (FI) objects. EBI is a full MS/TP master device. The MS/TP MAC address is configurable via seven DIP switches, or optionally using a soft-configured MAC address. EBI supports baud rates of 9600, 19200, 38400, 57600 and 115200. The device requires external network biasing and termination resistors when it is used as an end-of-line device. The MS/TP transceiver is optically isolated and the isolated ground is provided along with + and - EIA-485 terminations. You may configure the Device Object_Name and Object_Identifier and Max_Master by writing to the appropriate Device object properties. The built-in objects have a mostly fixed configuration of Object_Names, engineering units and state text. AI objects have only required properties. BI objects include fixed Inactive_Text and Active_Text property values, as well as all required properties. Objects BI52 through BI67 correspond to input and output contact statuses. The Object_Name property for these 16 objects are writable. File objects include a writable Archive property. Files are used to access one of three dynamic logs of Alarms, Tests and Events. 2 115194A - LV BACnet Communication Option

SECTION 3 Settings Termination, Baudrate and MAC Address: Off = factory defaults On = normal On On On = use soft baudrate (A) ( RX ) (B) ( TX ) ( COM ) On On Off = 9600 On Off On = 19200 On Off Off = 38400 Off On On = 57600 Off On Off = 115200 Off Off On = reserved Off Off Off = reserved Off = use soft MAC address On = use sw 1..7 for MAC 7 bit Mac (0..127) On = 0 Off = 1 Example is MAC 01 Factory Defaults: device.object_name EBI device.object_identifier Device 560000 device.max_master 127 device.macaddress 01 device.baudrate 38400 device.description device.database_revision 1 BI52.Object_Name Input Contact Status 1 BI58.Object_Name Input Contact Status 8 BI59.Object_Name Output Contact Status 1 BI67.Object_Name Output Contact Status 8 3 115194A - LV BACnet Communication Option

SECTION 4 Object Summary objectid object name notes AI1 INPUT VOLTAGE PHASE 1 VAC AI4 OUTPUT VOLTAGE PHASE 1 VAC AI7 OUTPUT CURRENT PHASE 1 A AC AI10 BATTERY VOLTAGE V AI11 AMBIENT TEMPERATURE C AI16 SYSTEM DAYS days (0..65535) AI17 UPS RUN TIME min (0..65535) AI18 INPUT CURRENT PHASE 1 A AC AI21 INPUT FREQUENCY Hz AI23 BATTERY TEMPERATURE C AI24 HEATSINK TEMPERATURE C AI25 BATTERY CURRENT A DC AI27 UPS EVENTS no units (0..65536) BI3 BATTERY CHARGING STATUS 1=charging BI4 BATTERY POWER STATUS 1=battery power BI6 NORMALLY OFF ACTIVE 1=Normally Off Active BI7 ON UTILITY 1=Utility Powering Load BI8 SHUTDOWN 1=Shutdown Mode Active BI9 STANDBY 1=Unit is in Standby BI10 BATTERY CHARGING BULK 1=Bulk Charging Mode BI11 BATTERY CHARGING 1=Absorption Charging Mode ABSORPTION BI12 BATTERY CHARGING FLOAT 1=Float Charging Mode BI13 MONTHLY TEST 1=Monthly Test Active BI14 YEARLY TEST 1=Yearly Test Active BI15 MANUAL TEST 1=Manual Test Active BI16 LOAD REDUCTION CALIBRATION 1=Load Reduction Calibration Active BI19 Short Circuit 0=normal 1=alarm BI20 Overcurrent 0=normal 1=alarm BI21 Low Voltage Disconnect 0=normal 1=alarm BI22 Heatsink Over Temp 0=normal 1=alarm BI23 Input Fuse Failed 0=normal 1=alarm BI24 Input not Present 0=normal 1=alarm BI25 Input fuse Failed 0=normal 1=alarm BI26 Battery Low 0=normal 1=alarm BI27 RTC Error 0=normal 1=alarm BI28 High Ambient Temperature 0=normal 1=alarm BI29 Low Ambient Temperature 0=normal 1=alarm BI30 High Battery Temperature 0=normal 1=alarm 4 115194A - LV BACnet Communication Option

Object Summary (con t) objectid object name notes BI31 Low Battery Temperature 0=normal 1=alarm BI32 Overload 0=normal 1=alarm BI34 Battery Not Connected 0=normal 1=alarm BI35 Battery Probe Not Connected 0=normal 1=alarm BI36 PLL Error 0=normal 1=alarm BI37 Input Frequency Low 0=normal 1=alarm BI38 Input Frequency High 0=normal 1=alarm BI39 Input Voltage Low 0=normal 1=alarm BI40 Input Voltage High 0=normal 1=alarm BI41 Output Voltage Low 0=normal 1=alarm BI42 Output Voltage High 0=normal 1=alarm BI43 Battery Charger 0=normal 1=alarm BI46 Load Reduction 0=normal 1=alarm BI49 Summary Contact 0=normal 1=alarm BI50 Year Test failed 0=normal 1=alarm BI51 Month Test Failed 0=normal 1=alarm BI52* Input Contact Status 1 0=normal 1=active BI53* Input Contact Status 2 0=normal 1=active BI54* Input Contact Status 3 0=normal 1=active BI55* Input Contact Status 4 0=normal 1=active BI56* Input Contact Status 5 0=normal 1=active BI57* Input Contact Status 6 0=normal 1=active BI58* Input Contact Status 7 0=normal 1=active BI59* Input Contact Status 8 0=normal 1=active BI60* Output Contact Status 1 0=normal 1=active BI61* Output Contact Status 2 0=normal 1=active BI62* Output Contact Status 3 0=normal 1=active BI63* Output Contact Status 4 0=normal 1=active BI64* Output Contact Status 5 0=normal 1=active BI65* Output Contact Status 6 0=normal 1=active BI66* Output Contact Status 7 0=normal 1=active BI67* Output Contact Status 8 0=normal 1=active FI1 AlarmLog FI3 TestLog * Object_Name is writable for these objects. 5 115194A - LV BACnet Communication Option

SECTION 5 Protocol Implementation Vendor Name: Myers Power Products, Inc. Product Name: EBI Product Model Number: PCB404303P00 Applications Software Version: v2.00 Firmware Revision: v1.03 BACnet Protocol Revision: 12 BACnet Standardized Device Profile (Annex L) EBI is capable of supporting the B-ASC profile and lower. BACnet Interoperability Building Blocks Supported (Annex K) DM-DDB-B, DM-DCC-B, DM-DOB-B,DM-TS-B, DM-RD-B, DS-RP-B, DS-WP-B Segmentation Capability EBI does not support segmentation. Standard Object Types Supported No object types may be dynamically created or deleted. EBI supports the following object types: Analog Input, Binary Input, Device and File. Optional Properties Supported: Device OBJECT_NAME writable 32 chars OBJECT_IDENTIFIER writable DESCRIPTION writable 64 chars Binary Input INACTIVE_TEXT read-only ACTIVE_TEXT read-only BI52..BI67 OBJECT_NAME writable 32 chars File ARCHIVE writable Data Link Layer Options MS/TP master (Clause 9): 9600, 19200, 38400, 57600, and 115200 baud Device Address Binding Static binding is not supported. Networking Options EBI does not provide router or Annex H tunneling or BBMD functionality. Character Sets Supported UTF-8 6 115194A - LV BACnet Communication Option