LMT F14. Cut in Three Dimensions. The Rowiak Laser Microtome: 3-D Cutting and Imaging

Similar documents
Optical coherence tomography

LASER TECHNOLOGY. Key parameters. Groundbreaking in the laser processing of cutting tools. A member of the UNITED GRINDING Group

taccor Optional features Overview Turn-key GHz femtosecond laser

Romania and High Power Lasers Towards Extreme Light Infrastructure in Romania

Overview of Commercially Available Femtosecond Lasers in Refractive Surgery

Femtosecond laser microfabrication in. Prof. Dr. Cleber R. Mendonca

Fiber Laser Chirped Pulse Amplifier

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

FemtoFAB. Femtosecond laser micromachining system. tel fax Konstitucijos ave. 23C LT Vilnius, Lithuania

Maria Smedh, Centre for Cellular Imaging. Maria Smedh, Centre for Cellular Imaging

Title: Laser marking with graded contrast micro crack inside transparent material using UV ns pulse

pulsecheck The Modular Autocorrelator

Single-photon excitation of morphology dependent resonance

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION:

Designing for Femtosecond Pulses

Fabrication of microstructures on photosensitive glass using a femtosecond laser process and chemical etching

Ultrafast Lasers with Radial and Azimuthal Polarizations for Highefficiency. Applications

Imaging the Subcellular Structure of Human Coronary Atherosclerosis Using 1-µm Resolution

Dr. Rüdiger Paschotta RP Photonics Consulting GmbH. Competence Area: Fiber Devices

Vixar High Power Array Technology

3D light microscopy techniques

Ultrafast instrumentation (No Alignment!)

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

ESCC2006 European Supply Chain Convention

APE Autocorrelator Product Family

Manufacturing Metrology Team

THz-Imaging on its way to industrial application

Non-Descanned FLIM Detection in Multiphoton Microscopes

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS

Spider Pulse Characterization

Pulse Shaping Application Note

Biophysical Basis of Optical Radiation Exposure Limits. Bruce E. Stuck

7 CHAPTER 7: REFRACTIVE INDEX MEASUREMENTS WITH COMMON PATH PHASE SENSITIVE FDOCT SETUP

The Importance of Wavelengths on Optical Designs

Lumenis Array LaserLink Pattern Scanning Laser Technology RETINA

Laser Speckle Reducer LSR-3000 Series

A miniature all-optical photoacoustic imaging probe

Laser processing of materials. Laser safety

Fast Laser Raman Microscope RAMAN

:... resolution is about 1.4 μm, assumed an excitation wavelength of 633 nm and a numerical aperture of 0.65 at 633 nm.

MEL 80 Excimer Laser. When you want to see better performance

EnFocus Your Upgrade Path to High Performance Intrasurgical OCT

Explain what is meant by a photon and state one of its main properties [2]

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

H. Lubatschowski T. Ripken, U. Oberheide, C. Ziltz, G. Gerten. Femtosecond Laser Applications in the Huaman Lens

Continuum White Light Generation. WhiteLase: High Power Ultrabroadband

Data sheet for TDS 10XX system THz Time Domain Spectrometer TDS 10XX

Chapter 23 Study Questions Name: Class:

venteon Ultra-short pulse oscillators

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

Fastest high definition Raman imaging. Fastest Laser Raman Microscope RAMAN

Precision Cold Ablation Material Processing using High-Power Picosecond Lasers

Imaging Retreat - UMASS Customized real-time confocal and 2-photon imaging

Moving from biomedical to industrial applications: OCT Enables Hi-Res ND Depth Analysis

Prepare Sample 3.1. Place Sample in Stage. Replace Probe (optional) Align Laser 3.2. Probe Approach 3.3. Optimize Feedback 3.4. Scan Sample 3.

Fast Raman Spectral Imaging Using Chirped Femtosecond Lasers

Drilling of Glass by Excimer Laser Mask Projection Technique Abstract Introduction Experimental details

Digital multimirror devices for precision laser micromachining

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Microscopic Structures

Agilent 8700 LDIR Chemical Imaging System. Bringing Clarity and Unprecedented Speed to Chemical Imaging.

Bioimaging of cells and tissues using accelerator-based sources

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1

Practical work no. 3: Confocal Live Cell Microscopy

Philip Sperling. Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany.

Micromachining with tailored Nanosecond Pulses

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust

Fiber-optic Michelson Interferometer Sensor Fabricated by Femtosecond Lasers

Unit Two Part II MICROSCOPY

some aspects of Optical Coherence Tomography

Information & Instructions

MULTIPHOTON MICROSCOPY. Matyas Molnar Dirk Pacholsky

You won t be able to measure the incident power precisely. The readout of the power would be lower than the real incident power.

FEMTOSMART. Benefits. Features

Fast Laser Raman Microscope RAMAN

SUPPLEMENTARY INFORMATION

University of Lübeck, Medical Laser Center Lübeck GmbH Optical Coherence Tomography

The spectral colours of nanometers

High Resolution Ocular Surface OCT to Directly Measure Tear Film Thickness in Human Eyes

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

The All New HarmoniXX Series. Wavelength Conversion for Ultrafast Lasers

Laser Speckle Reducer LSR-3000 Series

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

SUPPLEMENTARY INFORMATION

DeltaMyc. Fluorescence Lifetime Mapping Microscope. Affordable Fluorescence Lifetime Imaging Microscopy (FLIM)

Laser tests of Wide Band Gap power devices. Using Two photon absorption process

Non-contact Photoacoustic Tomography using holographic full field detection

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

Z-LASER Optoelektronik GmbH Stemmer 3d Technologietag Useful information on Z-Lasers for Vision

IC 2 S High Performance Objectives

Photoacoustic imaging using an 8-beam Fabry-Perot scanner

Micromachining of Glass by Laser Induced Deep Etching (LIDE) LPKF Vitrion 5000

Sub-ns Microchip Lasers Technology: Overview and Progress in Health Science and Industrial Applications Florent Thibault

VISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser

Single Frequency Laser/Single Longitudinal Mode Laser

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4

Transcription:

LMT F14 Cut in Three Dimensions The Rowiak Laser Microtome: 3-D Cutting and Imaging

The Next Generation of Microtomes LMT F14 - Non-contact laser microtomy The Rowiak laser microtome LMT F14 is a multi-purpose instrument designed for sectioning, microstructuring and imaging of biological tissue and various materials. Femtosecond laser technology is the key for this novel generation of microtomes. Ultrafast laser pulses enable precise, non-contact processing of specimens. A main advantage of the laser microtome is its ability to cut native tissue as well as hard tissue without decalcification. The LMT F14 is optionally available with a Navigation Modul. This tool is based on Optical Coherence Tomography (OCT), a threedimensional imaging technology. The unique combination of laser microtomy and OCT imaging allows 3-D navigated cutting, making the LMT F14 suitable for a wide range of applications in life sciences and materials research. Cutting-edge laser technology Main component of the LMT F14 is a NIR femtosecond laser. Near-infrared radiation is well suited for processing biological material, because most biological tissues have a very low absorption coefficient for this part of the spectrum. Thus specimens can even be manipulated inside. To perform a cut the laser beam is tightly focussed into the specimen by a high numerical aperture objective. Because of the very high photon density inside the laser focus, non-linear optical processes are induced, which finally lead to ablation. But this effect is only limited to the very small focal volume, thus allowing cuts with micrometer precision. Principle of laser microtomy: The focussed laser beam penetrates the tissue and performs a cut. Sectioning and 3-D 3 cutting LMT F14, stand-alone version (also available as table -top system) To prepare tissue sections the laser beam and the specimen are moved simultaneously - the laser beam by a fast scanner and the specimen by a three-axis piezo-driven positioning stage. Depending on the material being processed slice thicknesses of 7 to 100 µm are feasible. The method is not only suited to prepare thin slices but 3-D sections as well.

Navigation Module: See What You Cut! OCT-navigated cutting The LMT F14 is optionally available with a Navigation Module for three-dimensional imaging of specimens. This add-on module is based on Optical Coherence Tomography (OCT) and enables 3-D navigated cutting. Laser microtomy with integrated OCT imaging technology provides a unique combination of three-dimensional imaging and cutting, facilitating analysis and dissection of samples. A powerful combination The Navigate Module gives full control of cutting processes. It assists to predefine cutting geometries, to assess the cutting quality or to measure distances. Applications include controlled sectioning of biological tissues as well as cutting along predefined structures or even cell layers. OCT imaging is also suited to visualize the inner structure of different materials. This makes the LMT F14 with Navigation Module perfect for materials research. It can be used to identify regions of interest and to cut material samples. 3-D OCT image of a kiwi fruit section. 3-D OCT image of a ceramic scaffold for tissue engineering. Technical details The Navigation Module is equipped with a Spectral Radar OCT imaging system and an additional OCT-module containing the reference arm and optics for dispersion compensation. Based on a NIR laser the OCT system allows for deep penetration of biological tissues. A piezo-driven three axis positioning stage enables 3-D imaging and cutting. Porcine cornea. The cut was placed directly under the epithelium Cascaded cut inside Teflon.

Versatile Applications Sectioning, 3-D 3 cutting and structuring The LMT F14 is suitable for processing biological tissue as well as materials, such as ceramics, polymers and resins. It can be used to prepare thin tissue sections for microscopic examinations or to obtain cell material for the purpose of cultivation. The laser microtome is also ideal for microstructuring. Scaffolds for tissue engineering, for example, can easily be modified to support the cell growth. However, in combination with the Navigation Module the LMT F14 does not only allow for twodimensional sectioning but also for threedimensional cutting. This provides great flexibitity and enables novel applications. Porcine hyaline cartilage section, taken from native tissue. Porcine skin section, taken from native tissue. SEM image of a human hair. Laser microtomy leaves the inner structures intact. No time-consuming tissue preparation A cost and time saving benefit of the laser microtome is the ability to slice different biological tissues in their native states. Extensive and time-consuming sample preparation techniques are not required. In particular, the LMT F14 is an optimal solution for sectioning tissue which is sensitive to chemical fixation. The gentle and contact-free cutting method prevents tissue damage and contamination. Even sectioning of hard tissues such as bone and tooth is feasible without decalcification. Applications - overview Bovine tooth section, not decalificated. Porcine bone section, not decalcificated. Sectioning of small Teflon blocks. sectioning of native tissue samples sectioning of hard tissue samples cutting of predefined areas cutting and microstructuring of materials SEM image of a microstructured Teflon sample. three-dimensional processing and imaging

Easy to Use Software Intuitive graphical user interface The LMT F14 software provides an easy to use, intuitive graphical user interface. The software includes functions for sectioning, three-dimensional cutting and data storage. It also includes distance-measurement tools and different imaging features. Laser cutting The average laser power can be adjusted to match the different types of specimens. Cutting parameters such as scanner speed or stage speed can be changed as well. Different cutting modi enable two- and threedimensional sectioning. A freehand tool allows for various user-defined 3-D cutting geometries. The software can be upgraded with additional predefined cutting procedures. OCT imaging OCT imaging facilitates the navigation within the sample volume and assists to find cutting coordinates or take measurement. The software is able to generate 3-D OCT images. These images can be used to analyse the inner structure of samples or to check the quality of three-dimensional cuts. Control and safety An integrated camera allows for positioning of specimens and for online-monitoring of cutting processes. If necessary, the cutting process can be interrupted at any time. In this case the laser shutter closes automatically. Parameter setting for 3-D OCT imaging. Two-dimensional OCT imaging. The horizontal yellow line marks the cut. Parameter setting for 3-D cutting.

LMT F14 Specifications Design system versions stand-alone or table-top dimensions (stand-alone version) 1000 mm x 380 mm x 810 mm (Y x X x D) weight (stand-alone version) 100 kg Laser parameters laser system average output power repetition rate pulse duration wavelength solid-state femtosecond laser 2,5 W (5 W on request) 10 MHz 300 fs 1030 nm Positioning system minimum section thickness 7 10 µm cutting speed typically 1 mm²/s working area 14 x 14 mm² (larger on request) OCT system Central wavelength A-scan frequency Optical power Image speed Image depth Image size 900 nm +/- 5 nm ~ 5 khz ~ 1.5 mw ~ 1 fps (typically) max. 1.1 mm max. 1024 x 512 px Axial resolution 4.5 µm The standard solution does not meet your requirements? Then please contact us! Rowiak offers customized solutions and its expertise with femtosecond laser applications. Rowiak GmbH Garbsener Landstraße 10 D-30419 Hannover Germany Tel.: +49 (0)511 277 2950 Fax: +49 (0)511 277 2959 E-Mal: info@rowiak.de www.rowiak.com