Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions 8115F 8115SF

INSTALLATION INSTRUCTIONS

ONASSIS SHOWER SET INSTALLATION

Installation Instructions

INSTALLATION GUIDELINES

EXIRA SHOWER SET INSTALLATION

CALLAS THERMOSTATIC SHOWER SET

caroma marc newson shower mixer

INSTALLATION GUIDELINES

Installation Instructions

Installation Instructions 3/4 Thermostatic Valve Rough-in & Trim (PL8950)

INSTALLATION INSTRUCTIONS

MALEKO WALL-MOUNT FAUCET INSTALLATION

LATTIMORE SHOWER SET INSTALLATION

INSTALLATION INSTRUCTIONS FOR WALL TUB SETS, TWO HANDLE SHOWER SETS AND WALL LAVATORY SET VALVES NUMBERED: RC & RC

Pressure Balance Shower Only Dual Control (Volume & Temperature) Ceramic Disc Cartridge Platinum Shower Trim Kit

Traditional Wall Mounted Potfiller

caroma marc newson wall basin mixer

INSTALLATION GUIDELINES

Acrylic Claw Foot Tub

SEBASTIAN TUB FAUCET INSTALLATION

INSTALLATION INSTRUCTIONS FREE STANDING TUB FILLERS

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

GP-SD GENIE PROBE SMALL DIAMETER

MS25 OPERATION MANUAL

VICTORIAN WIDESPREAD FAUCET

WILLIS WALL-MOUNT FAUCET INSTALLATION

Flash Rough-In Valves

MUELLER GAS. DH-5 Drilling Machine. For use on 1 1 /2 & 2 Line Stopper Fittings. Reliable Connections. General Information 2

WILLIS WIDESPREAD FAUCET

Caution: Installation and Operation Instructions. Locking Mechanism (if supplied) Set Screws Backed Out. Mounting Orientation


H8508 Impact Wrench SERVICE MANUAL. Model (Serial Code FWN) Model (Serial Code FWP)

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections

Bodyspray INSTALLATION INSTRUCTIONS

Step by Step Installation Instructions. Poly Shutters. Customer Service or visit us online at smithandnoble.com

Chiltern Model Steam Engines

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7

EP-60 END OF CAR JUNCTION BOX KIT and ASSEMBLY AND INSTALLATION INSTRUCTIONS

General Array Layout Sketch

ROTUNDA WALL-MOUNT FAUCET INSTALLATION

Pet Door Panel Installation Manual

Bathroom Installation Guide

Cut-True 16M Manual Paper Cutter

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

SHUR-LOK CORPORATION TECHNICAL SALES BULLETIN

INSTALLATION INSTRUCTIONS

Clocking a TD-04 Turbo Compressor Housing. Appendix A : AWIC Silicone and Tubing Fitting

Mechanical Frappe Press

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

SHELTON THERMOSTATIC SHOWER PANEL

BETTIS SERVICE INSTRUCTIONS FOR MODELS G01 THROUGH G10 SERIES HYDRAULIC SPRING RETURN ACTUATORS WITH M11 HYDRAULIC OVERRIDE

BSM, GSM & GSS. Joint Kit Instruction. (Modified for IMPACT) (NSF Certified) Curved Glass Fresh Meat Delicatessen and Seafood Merchandisers

BETTIS SERVICE INSTRUCTIONS FOR MODELS G01 THROUGH G13 SERIES HYDRAULIC ACTUATORS WITH POWER MODULE TIE BAR CONSTRUCTION

A SRF/SERF A SRF/SERF

Thermostatic Valve Trim

HALSEY TAYLOR OWNERS MANUAL Contour TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

Tools Needed Hardware Provided (per shade) Hardware Needed

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

Installation Instructions

LPK1550 Hydraulic Crimping Tool 15-ton

A500 ASSEMBLY & INSTALLATION INSTRUCTIONS

Chin Strap, Sealed Pull Pins and Swing Catch for Fiberglass Helmets. Contents

Dublin Stalls Installation Instructions

CAELI THERMOSTATIC SHOWER PANEL

This product is designed for a water supply pressure range of 20 psi (137kPa) minimum to 80psi (550 kpa) maximum.

B-Too Drilling and Tapping Machine Instruction and Maintenance Manual

SUPER PRO GUN & SUPER PRO GUN II

Low Base 3, 4 and 5-Piece Showers with SnapJoint 3/4/5 LBS SJ

TABLE OF CONTENTS REQUIRED TOOLS

The Virgo/Libra Steam Engine

HB Coupling Expander Instructions

INSTRUCTIONS FOR USE Pro-Ject 9 Pro-Ject 9c Pro-Ject 9cc Pro-Ject 10cc Pro-Ject 12cc

HQ Hideaway. Installation and Operation Version 2.2, April 2015 Part # QT40100

HYDRO-TOWER INSTALLATION INSTRUCTIONS

Snap Tabs, Chin Strap, Swing Catch, Sealed Pull Pins Stainless Steel. Contents

1. Fasten press to bench or work surface using the mounting holes provided (Item 3).

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

Diptych Bath Screen Installation Guide

INSTALLATION GUIDE 2009-CURRENT HUMMER H3T PRODUCT CODE:

WHITE ARCHIPELAGO PRESSURE BALANCE MIXING VALVE TRIM ONLY, TO SUIT M ROUGH

Laminate Cabinet Installation Instructions

Installation Instructions ED4400, ED4400M & ED4400MA Series Surface Vertical Rod Exit Devices

SERVICE INSTRUCTIONS Model 9670 Lubricant Pump

BALANTINE WALL-MOUNT FAUCET INSTALLATION

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

REPAIR INSTRUCTIONS. Cat. No Cat. No MILWAUKEE ELECTRIC TOOL CORPORATION. SDS Max Demolition Hammer. SDS Max Rotary Hammer

Reliance SG800 Series Steel Water Gage Valves

REPLACEMENT TARP for SRT-2 SPOOL ROLL TARP

Installation and Maintenance Instructions

HANDHOLE SEAT GRINDER

B235 Mobius Sconce Page 1 of 6

GLENBROOK/GLENGUARD VITREOUS CHINA DRINKING FOUNTAIN/CUSPIDOR

Transcription:

MOUNT TUB SYSTEMS HAMPTON TRIM KIT T980.702 Installation Instructions T980.702 T980.712 T980.722 T980.732 Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. Trim Kits 4mm 5mm Certified to comply with ANSI A112.18.1 U.S. Patent No. D403,750 M968655A T980.722 4mm 5mm LEVER T980.712 4mm LEVER T980.732 4mm 1 INSTALLATION Complete FINISHED before trim installation. Turn off the water supplies. Remove the GUARDS from the BODIES. Remove the GUARD and 1/4" PLUG from the SHANK. 5mm The SHANK height should be 1" to 2" above the FINISHED. Cut the SHANK if necessary. Remove all burrs and bevel the end of the shank. Failure to do so may damage the O-ring during installation and cause water leakage. Drill a 3/16" hole in the finished deck. See TEMPLATE for location. FINISHED 1/4" PLUG SHANK GUARD GUARDS REMOVE ALL BURRS AND BEVEL 5mm 1"- 2" 3/16" DRILLED HOLE SHANK Product names listed herein are trademarks of American Standard Inc. American Standard Inc. 2000 19.8mm (23/32") FRONT 8.4mm (21/64") 3/16" DIA. HOLE 18.6mm DIA. (47/64") SHANK TEMPLATE FOR ROLL PIN LOCATION

1 CONTINUED Lubricate the O-RING and O-RING. Push on SHANK and align slot in with 3/16" drilled hole. Tighten SET securely with 4mm. Remove the PLUG BUTTON from the. 4mm SET FINISHED O-RING O-RING 3/16" DRILLED HOLE SHANK PLUG BUTTON 5mm 2 Position the in the groove in the base of the. Push the down onto the and tighten the SET securely with the 5mm. Insert the PLUG BUTTON into the. TRIM Place the SEALS over the BODIES. Thread the S into the BODIES. Align the STEM with the as necessary. Thread the into the BODIES until the contacts the finished deck. STEM SEALS BODY 4 TESTING 5 Turn the HOT clockwise and the COLD counterclockwise to the off position. Unscrew and remove the END. Slowly turn on the water supplies. Operate the S to flush water lines thoroughly. Check connection for leakage. Turn the Handles off. Replace the END. HOT COLD END 3 INSTALL GROOVE S LEVER Turn into OFF position. Push into in a way that the male square on the fits in the female square of the. O-RING SERVICE To change the direction of handle rotation Turn off the water supplies Turn to the off position. Remove the and the. Pull the off and remove. Unscrew the. Unscrew the LOCK NUT and remove. A 17mm deep socket is required. Remove the CARTRIDGE by pulling up on the. Remove the from the CARTRIDGE. Remove the SPRING CLIP. Remove the STOP. Turn it 90 and replace. Replace the SPRING CLIP. STOP 90 LOCK NUT SPRING CLIP Push and onto STEM. Check alignment, if not satisfactory aligned; Push out carefully. Turn into OFF position. Turn either 45 or 90 so that male square on Push into. catches different female square in. Assemble and tighten. Push in top of. LEVER STEM Push and onto STEM. Push onto. Assemble and tighten. Push in top of. HOTLINE FOR HELP For toll-free information and answers to your questions, call: 1 (800) 442-1902 Weekdays 8:00 a.m. to 7:00 p.m. Eastern Time IN CANADA 1-800-387-0369 (TORONTO 1-416-536-5609) Reverse the above steps to reassembly the components. If the spout drips, operate the handles several times from the off to the on position. Do not force - the handles only turn 90 CARTRIDGE M968655A

MOUNT TUB FILLERS HAMPTON & PERSONAL TRIM KITS Installation Instructions T991 SERIES Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. T991.702 Trim Kits Certified to comply with ANSI A112.18.1 U.S. Patent No. D403,750 M968357 T991.722 HAND SEAL HAND SEAL SEAL SEAL T991.712 T991.732 LEVER HAND SEAL LEVER HAND SEAL SEAL SEAL 1 INSTALL GUARD STEM REMOVE THE GUARD. Place the SEAL over the BODY. Thread the into the BODY. Align the STEM with the as necessary. Thread the into the BODY until the contacts the finished deck. SEAL FINISHED

2 INSTALL S LEVER S LEVER S LEVER LEVER Turn STEM fully clockwise (Tub Fill position). 3 Push into in a way that the male square on the fits in the female square of the. STEM Push and onto STEM. Check alignment, if not satisfactory aligned; Turn STEM fully clockwise Push out carefully. (Tub Fill position). Turn either 45 or Push into. 90 so that male square on catches different female square in. Assemble and tighten. Push in top of. INSTALL HAND Push and onto STEM. Push onto. Assemble and tighten. Push in top of. Unscrew the from the. Slip the through the and the. Insert a SEAL into the CONNECTOR. HAND Pull out the GUARD and. Unthread the GUARD from the END connection. Be careful not to allow the to fall back through the. Thread the onto the END connection and tighten securely. Apply a sealant around the HOLE. Thread the into the until the contacts the finished deck. SEAL HAND Loosen the SET in the and rotate the towards the center of the tub. Retighten the SET. Thread the into the. Insert a SEAL into the connector and connect the HAND. Place the HAND into the. GUARD SEAL END SET HOTLINE FOR HELP For toll-free information and answers to your questions, call: 1 (800) 442-1902 Weekdays 8:00 a.m. to 7:00 p.m. Eastern Time IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) Product names listed herein are trademarks of American Standard Inc. American Standard Inc. 2000 SEALANT M968357

MOUNT TUB SYSTEMS ROUGH KIT Installation Instructions R800 SERIES R810 SERIES R810 SERIES Thank you for selecting American-Standard... the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. R800 SERIES Certified to comply with ANSI A112.18.1 U.S. Patent No. D403,750 M968650C 1 ROUGHING-IN 2 FINISHED 1-3/8 D MAX. 1 D MAX. ACRYLIC BATH 4 1. THICKNESS TOTAL THICKNESS UP TO 2-1/2" 2. FINISHED FINISHED VARIABILITY ACCOMMODATES ING MATERIAL (TILE, MARBLE, CORIAN...) TO 1" THICK 1 3 FITTING SURFACE (2) 1-3/8 D HOLES 1" D 1/2" COPPER INLET SUPPLIES 8" to 12" 10" for R810 7-1/8 3. FITTING SURFACE ADJUSTABILITY, TO 1-1/2" THICK 4. ACRYLIC BATHS ADJUSTABILITY, TO 1-1/2" THICK 8" to 12" 10" for R810 1" D HOLES (2) 1-3/8 D HOLES 2 MOUNT SHANK Drill holes in mounting deck as shown. The maximum allowable deck thickness is 1-1/2". Insert the SHANK through the mounting deck from below. Assemble the SHANK LOCK RING so it is flush with the top of the threads on the SHANK. SHANK LOCK RING FLUSH WITH TOP OF THREADS ON SHANK SHANK LOCK RING SHANK FRICTION NUT SHANK 1-1/2 MAX. FITTING

3 MOUNT BODIES Cut the copper outlet tubes of the BODIES as required. (Not necessary for R810). Insert the HOT and COLD BODIES into the TEE. (Not necessary for R810). The HOT BODY is marked with a red label. Insert the BODIES and TEE through the mounting deck from below. Assemble the LOCK RINGS so they are flush with the top of the BODIES. Insert the SHANK into the TEE. (Not necessary for R810). Tighten the BODY and SHANK NUTS securely. Fasten the LOCK RING to the wooden mounting surface with #8 screws (not provided). BODY FITTING LOCK RING FRICTION NUT LOCK RING FLUSH WITH TOP OF THREADS ON SHANK LOCK RING # 8 S HOT SHANK COLD TEE OUTLET TUBE (CUT AS REQUIRED) 4 SOLDER CONNECTIONS Connect the water supply lines to the copper inlet tubes of the BODY. Solder all TEE and WATER SUPPLY CONNECTIONS. Remove the GUARD from the SHANK. Assemble the 1/4" PLUG to the SHANK with a thread sealant. Turn on the water supplies and check all connections for leakage. Replace the GUARD on the SHANK. Turn off the water supplies. GUARD 1/4" PLUG TEE CONNECTIONS WATER SUPPLY CONNECTIONS 5 SERVICE TO CHANGE THE DIRECTION OF ROTATION DEEP SOCKET 17mm (11/16") Turn off the water supplies. Turn to the off position. Unscrew the LOCK NUT and remove. A 17mm deep socket is required. STOP 90 LOCK NUT Remove the CARTRIDGE by pulling upon the. Remove the from the CARTRIDGE. SPRING CLIP Remove the SPRING CLIP. Remove the STOP. Turn it 90 and replace. Replace the SPRING CLIP. CARTRIDGE Reverse the above steps to reassembly the components. If the spout drips, operate the handles several times from the off to the on position. Do not force - the handles only turn 90 M968650C

MOUNT TUB SYSTEMS MODEL NUMBERS R800 R810 LOCK RING M906671-0070A LOCK NUT A911546-0070A 918319-0070A LOCK RING A906110-0070A SPINDLE 903898-0070A KIT M962279-0070A CARTRIDGE 994053-0070A DEEP SOCKET 17mm (11/16") M962273-0070A KIT M962278-0070A R810 SERIES SOCKET NOT INCLUDED WITH FITTING HOTLINE FOR HELP For toll-free information and answers to your questions, call: 1 (800) 442-1902 Weekdays 8:00 a.m. to 7:00 p.m. Eastern Time IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) Product names listed herein are trademarks of American Standard Inc. C American Standard Inc. 2003 *WITH BRAZED TEE M968650C

MOUNT TUB FILLERS & PERSONAL ROUGH KIT Installation Instructions R890 SERIES Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. Certified to comply with ANSI A112.18.1 U.S. Patent No. D403,750 M968355D 1 ROUGHING-IN 1 1-3/8 D HOLE 1-3/8 D MAX. 6 to 18 FINISHED 2 1-3/8 D MAX. ACRYLIC BATH 4 1. THICKNESS TOTAL THICKNESS UP TO 2-1/2" 2. FINISHED FINISHED VARIABILITY ACCOMMODATES ING MATERIAL (TILE, MARBLE, CORIAN...) TO 1" THICK 3. FITTING SURFACE ADJUSTABILITY, TO 1-1/2" THICK 3 3-5/8 TUB 4-5/16 5-5/16 1-3/8 D 4. ACRYLIC BATHS ADJUSTABILITY, TO 1-1/2" THICK 1/2" NPT FITTING SURFACE SHW 1/2" NPT INLET 1-3/8 D HOLE FOR 1-3/8 D HOLE FOR HAND 6 to 18 HOLES 2 LOCATION OF R890 WHEN USED WITH R800 R800 ROUGH KIT R890 SERIES & PERSONAL ROUGH KIT 8" to 12" HOT AND COLD BODIES "A" DIMENSION CAN BE FLEXIBLE TO ACCOMMODATE CUSTOMER'S REQUIREMENTS A A 6" to 18" BATH CONNECTION HAND CONNECTION TUB HOT INLET COLD INLET 1/2" COPPER WATER TUBE INLET (MIXED SUPPLY FROM BATH FITTING) PLUMBER TO MAKE ALL PIPING CONNECTIONS BETWEEN BODIES, SUPPLY TO TRANSFER AND CONNECTION TO BATH. PIPING SHOWN SHADED IS NOT SUPPLIED AND MUST BE FURNISHED BY INSTALLER. SHW 1/2" COPPER WATER TUBE (MIXED SUPPLY TO TUB FILLER ) OUTLET (MIXED SUPPLY TO HAND )

3 INSTALLATION NOTE: Use thread sealant on all threaded connections. Drop the (1) into the hole in the mounting deck. 4 5 Assemble the (2) and LOCKNUT (3) to the (1) and tighten securely. For copper water tube installations, make two 4" long adapter nipples ( 1/2" Male NPT x 1/2" CWT ). Thread nipples into the inlet and tub outlet of the BODY. Tighten connections securely. Do Not Solder these Connections on the BODY. Damage may occur. Thread (4) into the CONNECTION (5) of the BODY (6) and tighten securely. Check with local plumbing codes for backflow prevention requirements. Install a backflow prevention device if required. Assemble NUT (7) and (8) onto BODY (6). Insert the BODY (6) through the mounting deck from below. Assemble the LOCK RING (9) so it is flush with the top of the BODY (6). Position the BODY (6) as required and tighten the NUT (7) securely. Fasten the LOCK RING (9) to the wooden mounting surface with #8 screws (not provided). Connect the water inlet and tub outlet lines to the BODY (6). TEST Cap the OUTLET. Remove the GUARD. Remove the GUARD. Assemble the 1/4" PLUG to the SHANK with a thread sealant. See the R800 SERIES ROUGH KIT instructions for details. Turn on the water supplies. Rotate the back and forth fully. Check all connections for leakage. Turn off the water supplies. Replace the GUARD and the GUARD. Remove the from the OUTLET. Note: Test Cap not provided. 1/2" COPPER WATER TUBE (MIXED SUPPLY TO TUB FILLER ) Insert the through the from below the mounting deck. Thread the GUARD onto the END connection. LOCK RING FLUSH WITH TOP OF THREADS ON SHANK BODY FITTING SURFACE #8 S TUB OUTLET GUARD #8 S OUTLET (MIXED SUPPLY TO HAND ) 9 5 4 8 7 GUARD 1 6 1-3/8" Dia. HOLE FOR HAND WATER INLET 4" LONG NIPPLES 1/2" COPPER WATER TUBE INLET (MIXED SUPPLY FROM BATH FITTING) END 2 3 6 Insert the GUARD into the. SERVICE TO REMOVE Turn off the water supplies. Turn to the off position. Remove the from by losening screw. Using 14mm (9/16") Deep Socket, remove diverter. DEEP SOCKET 14mm (9/16") M968355D

& PERSONAL ROUGH KIT MODEL NUMBER R890 LOCK RING M906671-0070A 918319-0070A KIT M962278-0070A 903898-0070A 922700-0070A 954559-0070A KIT M962280-0070A M923016-0070A HOT LINE FOR HELP For toll-free information and answers to your questions, call: 1-800 442-1902 Weekdays 8:00 a.m. to 8:00 p.m. EST IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) Weekdays 8:00 a.m. to 7:00 p.m. EST IN MEXICO 01-800-839-12-00 Product names listed herein are trademarks of American Standard Inc. American Standard Inc. 2004 M968355D