RG6-AB6- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 6 Mulfingen Phone: + 798 8- Fax: + 798 8- www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor RG6-AB6- MG-IF Phase ~ Nominal voltage [VAC] Nominal voltage range [VAC] 8.. 48 Frequency [Hz] /6 Type of data definition ml Speed [min - ] Power input [W] 8 Current draw [A] 4, Min. ambient temperature [ C] -5 Max. ambient temperature [ C] Air flow [m /h] Back pressure [Pa] Sound pressure level 7 ml = max. load me = max. efficiency rfa = running at free air cs = customer specs cu = customer unit Subject to alterations Item no.: 4-5-998 Revision status: KM6 Print-out on.7.9 Created by. Uhlmann (VM-TDO) Page of 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 6 Mulfingen Phone: + 798 8- Fax: + 798 8- www.ebmpapst.com info@de.ebmpapst.com
RG6-AB6- Technical features Leackage current General description Size Operation mode Direction of rotation Mounting position Electrical leads EMC interference emission EMC interference immunity Insulation class Condensate discharge holes Bearing motor Mass Material of electronics housing Material of impeller Motor protection Product conforming to standard Surface of rotor Number of blades 6 <=,5 ma Integrated electronics 6 mm Continuous operation (S) Clockwise, seen on rotor Shaft horizontal or rotor on bottom; rotor on top on request Via terminal box Acc. to EN 6-6- (household environment) Acc. to EN 6-6- (industrial environment) "F" Rotor-side Ball bearing 9 kg Die-cast aluminium Sheet aluminium, laser-welded Reverse polarity and locked-rotor protection CE Type of protection IP 54 Coated in black Protection class I (acc. to EN 68-5-) Technical features Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Approval - PFC, passive - Control input - VDC / PWM - Over-temperature protected electronics / motor - Alarm relay - Integrated PID controller - Input for sensor - V or 4- ma - Output for slave - V - RS485 ebmbus - Line undervoltage / phase failure detection - Motor current limit - Soft start - Output VDC, max. ma - Output VDC, max. ma +8 C -4 C CSA C. Nr.; GOST; UL 4; VDE Item no.: 4-5-998 Revision status: KM6 Print-out on.7.9 Created by. Uhlmann (VM-TDO) Page of 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 6 Mulfingen Phone: + 798 8- Fax: + 798 8- www.ebmpapst.com info@de.ebmpapst.com
RG6-AB6- Product drawing Cable diameter: min. 4 mm, max. mm, tightening torque: 4±.4 Nm Accessory part: inlet nozzle 67--4 not included in the standard scope of delivery; other inlet nozzles on request Depth of screw max. 5 mm 4 Tightening torque.5±.5 Nm Item no.: 4-5-998 Revision status: KM6 Print-out on.7.9 Created by. Uhlmann (VM-TDO) Page of 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 6 Mulfingen Phone: + 798 8- Fax: + 798 8- www.ebmpapst.com info@de.ebmpapst.com
RG6-AB6- Connection screen No. Pin Signal Function / assignment PE PE Protective earth connection KL,, L, L, L Supply voltage, /6 Hz KL NC Floating status message contact, normally closed connection KL COM Floating status message contact, changeover contact, common connection ( A, max. VAC, min. ma, AC) KL NO Floating status message contact, normally open connection KL OUT Analog output, - VDC, max. ma, SELV, output of the current level control coefficient: V equates to % level control coefficient. V equate to % level control coefficient. KL, 8 GND Reference mass for control interface, SELV KL, 7 - V Use control / actual value input - VDC, impedance kω only as alternative to 4- ma input, SELV KL 4 + V Voltage output VDC (+/- %), max. ma, supply voltage for ext. devices (e.g. potentiometers), SELV KL 5 + V Voltage output VDC (+5 %/- %), max. ma, supply voltage for ext. devices (e.g. sensors), SELV KL 6 4- ma Use control / actual value input 4- ma, impedance Ω, only as alternative to - V input, SELV KL 9, RSB RS485 interface for ebmbus, RSB, SELV KL, RSA RS485 interface for ebmbus, RSA, SELV Item no.: 4-5-998 Revision status: KM6 Print-out on.7.9 Created by. Uhlmann (VM-TDO) Page 4 of 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 6 Mulfingen Phone: + 798 8- Fax: + 798 8- www.ebmpapst.com info@de.ebmpapst.com
RG6-AB6- Charts: Air flow Hz Druck für Rho=,kg/m^. 4. V [cfm] 6. 8.. 8 8 7 7 6 6 5 4. 6 5 4. 4 6. 4 8 7 6 8. 9. V [m^/h]. 5 4. 6. 8.,4,,,,9,8,7,6,5,4,,,,9,8,7,6,5,4,,,,9,8,7,6,5,4,,,. Pfa_E [IN HO] Measurement: LU-9 Measurement: LU-68 Measurement: LU-4 Measurement: LU-4 Measured values Conn. U [V] f [Hz] n [min - ] P [W] I [A].7 LpA ss 78 LpA ds 76 LwA ss 85 LwA ds 9 V p fa [m /h] [Pa] 64 458.7 88 88 8 4. 7 7 79 86 4 69.98 8 87 765 6 5.7 7 7 79 85 7 6 5. 69 76 5 7 7 5. 8 99 54 8 8.5 75 6 447 9 7 4. 64 6 7 77 8 7 554.9 6 6 8645 96 7 654.5 59 59 695 7 57.94 6 6 45 5 6.5 5 5 6 66 7 4 79.8 57 6 5765 4 5 8.4 57 6 46 9 6 88.4 56 6 7 Item no.: 4-5-998 Revision status: KM6 Print-out on.7.9 Created by. Uhlmann (VM-TDO) Page 5 of 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 6 Mulfingen Phone: + 798 8- Fax: + 798 8- www.ebmpapst.com info@de.ebmpapst.com