CoMo Injection/CoMo Injection Basic

Similar documents
CoMo Injection/CoMo Injection Basic

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

Kistler LabAmp for DynoWare

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

SCP for Combustion Engines

SCP for Combustion Engines

Measuring Modules for SCP Slim Charge amplifier without sensor identification Type 5064B11 Charge amplifier with sensor identification Type 5064B12 Pi

SCP SUNSTAR传感与控制 for Combustion Engines Signal Conditioning System, with optional PiezoSmart, TEL: Modules for

Technical Data Sensor Input Input voltage measuring range (FSO) V 0 ±10 Max. input voltage V <±15 Resolution mv 5 with oversampling 14 Bit mv

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

SCP Slim for engine indication

SCP Slim for engine indication

Differential charge amplifier

Differential Charge Amplifier

Portable Multi-Channel Recorder Model DAS240-BAT

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

Multichannel Charge Amplifier

Ideal for high dynamic range measurements from compression to noise floor

Product Catalog. Sensors and Solutions for Cutting Force Measurement.

Increased cost efficiency with cavity pressurebased

GFT bit High Speed Digitizer

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.

Advanced Injection moulding, monitoring and control

FD 5 / 10 / 15. Fast acquisition module with universal synchronized inputs and embedded webserver software

Charge Meter. Electronics & Software. Universally Applicable for Piezoelectric Measuring Technology. Type 5015A...

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

Melt Pressure Measuring Chain

GFT Channel Digital Delay Generator

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

Universally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Instant value. Extreme values ors statistic measurements

Universally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Extreme values ors statistic measurements

CAN-IO Custom IO remote module

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MX1601B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

Pole Vault Force Plate with integrated electronics Specification control sheet

ma. JUMPFLEX 857 Series. Transducers / Relay and Optocoupler Modules

MX1615. Data sheet. Bridge/strain gauge amplifier

DIGEM f 96 x 48 EK. Applications. Description

SmartCrash Overlap Segment

Torque Station Pro TS-7700 System

Multichannel Amplifier System

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

RC4DAT-6G-60. The Big Deal

AS-1250FE Datasheet Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis

RCDAT The Big Deal

GFT1504 4/8/10 channel Delay Generator

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

Correlation of Voltage and Temperature Measurement

RCDAT The Big Deal

ICPU2-8 for imc CRONOSflex (CRFX/ICPU2-8)

VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE Page 1 of 7

SVP CONTROL AND VISUALIZATION OF VOLTAGE, PHASE AND FREQUENCY IN THREE-PHASE LINES WITH NEUTRAL

imc C-SERIES: CS-1016-N, CL-1032-N

POINTAX 6000L2 Point Recorder

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

FM 355 CONTROLLER MODULE


Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources.

NEW! AOIP FD5 Advanced Digital Data Logger

GPS Time and Frequency Reference Receiver

Data Acquisition Modules/ Distributed IO Modules

VersaPoint I/O Module

ONEXIS AUTOMATIONS PVT LTD B-8, First Floor, Industrial Area, Sector - 64, NOIDA , U.P, India Ph:

MC108A-2 RF MULTI-COUPLER USER S GUIDE

Water Cooled Absolute Pressure Sensor

TORKEL 900-series Battery Load Unit

The wireless alternative to expensive cabling...

TORKEL 900-series Battery Load Unit

IS-3000 SERIES INFRARED SCANNER

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

A Super trainer with advanced hardware and software features only found in very expensive equipment.

R&S OSP Open Switch and Control Platform Specifications

5000 Series Receiver Systems

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

HE693THM884/888 High Resolution Thermocouple Module Product Specifications and Installation

MODEL: DLS. Telemetering System

Modicon Momentum automation platform 0

CANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en

Simplified Operations for TM-3100 Series Digital Tachometer

RUDAT Key Features. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Uni-Mux XQL Multi-Channel Data Acquisition Module

02/11/2015

Fiber displacement sensor

DIN Thermocouple Conditioner MODEL 5M14(V)

MX1615B. Data sheet. Bridge/strain gauge amplifier

MCTS II Multi Channel Current Transducer System. Installation Manual

R&S OSP Open Switch and Control Platform Specifications

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

Acceleration sensors With relay output for limit monitoring Analog / CANopen

MULTIFUNCTION GRAPHICAL UNIT MGU 800

User s Manual for Integrator Short Pulse ISP16 10JUN2016

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

General Specifications

DE MEDIDA PROGRAMABLES - CLASE 0,2 MEASURING PARAMETER. Apparent power, per phase and total

Transcription:

Electronics & Software CoMo Injection/CoMo Injection Basic Zero-Defect Production during Injection Molding thanks to Process Monitoring Type 2869B CoMo Injection is a production optimization, control and monitoring system for injection molding of plastics. All functions required for evaluation and optimization of the injection molding process are integrated into a compact unit. This unit allows direct connection of piezoelectric cavity pressure sensors, and acquisition and evaluation of signals from the injection molding machine or other sensors. Depending on the model, CoMo Injection supports 4 (Basic), 12 or 24 channels. The CoMo DataCenter Type 2829B... database enhances Co- Mo Injection's capabilities with curve analysis, statistics functions and reporting. Compact robust All-in-one unit Process monitoring and visualization up to 24 channels Real-time control of the injection molding process 1 Automatic hot runner balancing (optional) Separation of good/bad parts Visualization and operation with touch screen display (SVGA 12,1") or Webbrowser No PC required Multi-channel cable technology Network or stand-alone version Optional saving of data in a central database Process and quality documentation Automatic mold identification ERP interface for exporting data Description CoMo Injection fits specifically to the requirements of the injection molding production process. As the 4-channel version CoMo Injection Basic is equipped with inputs for four piezoelectric pressure sensors. The inputs of the 12-channel version are designed as 8 pressure and 4 voltage channels. The 24-channel version has 16 pressure and 8 voltage inputs. The system is equipped with multichannel cable technology. This technology means that up to 8 sensors can be connected with just one connector to the mold and one connecting cable to CoMo Injection. Up to 48 monitoring functions guarantee reliable reject separation on the basis of the recorded data. At the same time the injection molding process can be controlled using real-time thresholds 1. Injection machine or reject diverters can be controlled directly via 12 digital outputs. CoMo Injection is available with the option of MultiFlow automatic hot runner balancing for multicavity molds. The cavity pressure profiles are used to optimize the hot runner temperatures for synchronous filling of all cavities. The new temperature set points are automatically transferred to the controller or machine via an interface. This produces a closed control loop, which automatically ensures synchronized filling of all cavities. The hot runner is balanced automatically during multicavity mold start-up. This completely avoids any need for manual optimization. Rebalancing is performed automatically during production. The visualization of the process and calculated data on the ma - chine as well as the configuration of the system are perfor med by the optional operating unit or a PC. The operation of CoMo Injection has been adapted to the sequence of operations of the molding process (setting-up, starting, production). The required inputs have been reduced to a minimum. Configuration data is saved with reference to the mold and article. CoMo Injection can be easily integrated into existing company networks. The process data related to a specific production order can be saved in the Kistler database CoMo DataCenter Type 2829B and evaluated with the integrated modules process statistics and Curve Viewer. 1 Optional in the case of the CoMo Injection Basic Type 2869B0... Page 1/12

Application CoMo Injection is used in the plastic injection molding process for mold validation and optimization production monitoring process documentation Mold Validation and Optimization The mold cavity pressure and machine signals viewed with CoMo Injection are used in mold validation and optimization to evaluate the optimum setting parameters, minimize the cycle time and assess process reliability. Real-time switching functions 1 are available both during optimization and during the subsequent production stage for controlling the process. This allows implementation of a wide variety of control functions, such as cavity pressure based changeovers from injection to holding pressure, or cascade control. With the MultiFlow option, multicavity molds are balanced automatically. IT Environment for Network Access to CoMo Injection Any operating system Web browser with Java Virtual Machine (for Windows, included on the CoMo CD-ROM, Art. No. 7.643.027) IT environment for backup/restore service Windows XP Professional, Windows 2000, Windows Vista or Windows 7 Supported Hot Runner Controllers: The list of these is constantly being expanded. Please contact your local Kistler distributor. Production monitoring Numerous monitoring functions are available for production monitoring and reject separation. The results of these functions can be linked with the 11 digital outputs, enabling a connected handling system or a reject diverter to remove the rejected parts reliably from the batch. Production documentation There is also the option of saving the production data in the CoMo DataCenter Type 2829B.... The saved curves can be displayed and analyzed with the Curve Viewer module. The Process Statistics module allows automated production of quality documentation and statistical analysis of production. ERP interface As an alternative to CoMo DataCenter, it's possible to export all of the measured curve data, evaluation results, number of good/bad parts, etc., directly to a third party (for example ERP or similar) system. There is comprehensive documentation available on integration and use of the interface. This and other information is available on request from your Kistler contact. 1 Optional in the case of the CoMo Injection Basic Type 2869B0... Page 2/12

Technical Data General Number of channels 4/12/24 Measuring time s <600 Number of evaluation objects 48 Number of real-time thresholds per channel up to 2 Jitter real-time thresholds ms <0,18 Reaction time real-time thresholds ms <4 Sampling rate Hz 1 200 Cut-off frequency ( 3 db) Hz 368 Dimensions (excluding display) mm 208x70x172 Operating temperature C 0 50 Voltage supply VDC 19 30 Power consumption (incl. display 12,1" W 70 and external measuring amplifier) Supply for external measuring VDC 24 transducer and proximity switch Max. current consumption A 0,4 collective external measuring amplifier Max. current consumption A 0,05 proximity switch Voltage between signal lines and case V <±40 Ethernet RJ45 10 base-t, electrically isolated, twisted pair Internal memory for tools and articles 30/60 Charge Inputs Number 1x4 / 2x4 / 1x8 / 2x8 Measuring range pc ±2 000 50 000 Range 1 pc ±2 000 Range 2 pc ±5 000 Range 3 pc ±20 000 Range 4 pc ±50 000 Drift at 25 C pc/s <0,1 at 50 C pc/s <0,5 Voltage Inputs Number 0/4/8 Type of input differential Measuring range V 0 10 Common-mode voltage range V ±40 Input impedance MΩ >1 Digital Inputs Type Electrically separated (AC optocoupler) Number of channels 6 Max. input voltage (constant) VDC ±40 Switching threshold high VDC >8 Switching threshold low VDC <2 Input current at 24 V ma 3,5 Page 3/12

Digital Outputs Type Electrically separated (Photo MOS relay) Number 12 Current load, pulse <0,1 s ma <360 Current load (constant at 25 C) ma <100 Impedance in the switched condition Ω <35 Max. voltage (constant) VDC ±40 Voltage Inputs Pin Allocation Function Pin Channel 1 + 1 Channel 1 2 Channel 2 + 3 Channel 2 4 Channel 3 + 5 Channel 3 6 Channel 4 + 7 Channel 4 8 24VDC 9 Reset-Operate 10 Reserved 11 Reference point_out 12 Reserved 13 Reserved 14 EGND 15 Type: D-Sub 15 pin neg. Voltage Input Ch 1 4 Digital I/O Auxiliary Pin Allocation Function Default Allocation Pin Reserved 1 Reserved 2 Reserved 3 Reserved 4 Reserved 5 open 6 DO_1 7 DO_2 8 DO_3 9 DO_4 10 DO_5 11 DO_6 12 DO_7 13 DO_8 14 Reference point_out 15 Type: D-Sub 15 pin male Digital I/O Auxiliary Digital I/0 IMM Pin Allocation Function Default Allocation Pin Dl_1 Cycle start_in 1 Reference point_in 2 Reserved 3 open 4 DO_1 Device ready 5 DO_2 RT Tresholds 6 DO_3 EO "Sorting" 7 DO_4 Alarm 8 Reference point_out 9 Type: D-Sub 9 pin male Digital I/O Molding Machine Proximity Switch Pin Allocation Function Pin 24VDC 1 Factory Reset A 2 Trigger 3 Factory Reset B 4 EGND 5 Type: M12, 5 pin neg. Proximity Switch Power Supply for External Devices Pin Allocation Function Pin 24VDC 1, 4 EGND 2, 3 Type: M12, 4 pin neg. Page 4/12

Fig. 1: Dimensions CoMo Injection measuring and control unit Type 5865B Fig. 2: Dimensions CoMo Injection touch display 12,1" Type 5629B3 Page 5/12

Process Data Views in PC's/Laptops (Large View)/12,1" Display Fig. 3: Measurement view Fig 4: Overview Page 6/12

Fig. 5: MultiFlow Automatic Hot Runner Balancing x 1 Proxi Switch Type 2231A1 D-Sub 15 neg., IP67 Type 1500A42A D-Sub 9 neg., IP67 Type 1500A43A Ethernet cable, IP67 Type 1200A49A1 Connecting cable, IP67 Type 1500A45A7 Power adapter 110 240 VAC/24 VDC Type 5781A2 Fig. 6: Connections to the measuring unit Page 7/12

Connection of Cavity Pressure Sensors (max. 4, 1x4) Connection of Cavity Pressure Sensors (max. 8, 2x4) Type 1995A... Type 1995A Type 1457A1A Type 1457A2A Amplifier for temperature sensors Type 2205A... Fig. 7: CoMo Injection Type 2869B0 4-channel connector with mold identification Type 1708A1 (operating temperature range 125 C) without mold identification, Type 1708A0 Fig. 8: CoMo Injection Type 2869B1 4-channel connector with mold identification Type 1708A1 (operating temperature range 125 C) without mold identification, Type 1708A0 Connection of Cavity Pressure Sensors (max. 8, 2x4) Connection of Cavity Pressure Sensors (max. 16, 2x8), Machine Signals and Pressure/Temperature Sensors Type 1997A Fig. 9: Type 1457A1A Type 1457A2A CoMo Injection Type 2869B2 Amplifier for temperature sensors Type 2205A... 8-channel connector with mold identification, Type 1710A1 (operating temperature range 125 C) without mold identification, Type 1710A0 Type 1997A Fig. 10: Type 1457A1A Type 1457A2A CoMo Injection Type 2869B3 Amplifier for temperature sensors Type 2205A... 8-channel connector with mold identification, Type 1710A1 (operating temperature range 125 C) without mold identification, Type 1710A0 Page 8/12

Connection of Cavity Pressure Sensors (max. 8, 2x4), for Molds with Single Fischer Connector Fig. 11: CoMo Injection Type 2869B1 Connection of Cavity Pressure Sensors (max. 16, 2x8), for Molds with Single Fischer Connector Fig. 12: CoMo Injection Type 2869B3 Page 9/12

Accessories Included Type/Art. No. CoMo Injection, configuration on 5865B... ordering key Ethernet cable crossed, RJ45, 5 m 1200A49A1 Mounting set comprising 2 mounting 7.511.339 brackets plus 4 fastening screws Case feet self-adhesive black 5.211.368 CD-ROM with software for CoMo Injection 7.643.027 Type 2869B... incl. control unit Type 5629A1/ A3/B3 and instruction manuals Accessories Base Unit Connecting cables, D-sub 15 pin neg., IP67, with flying lead for digital signals Length l = 0 m (connector only) Length l = 7 m (L min = 1 m/l max = 15 m) Type/Art. No. 1500A42A0 1500A42A7 1500A42Asp Connecting cables, D-sub 9 pin neg., IP67, with flying lead for digital machine signals Length l = 0 m (connector only) 1500A43A0 Length l = 7 m 1500A43A7 1500A43Asp (L min = 1 m/l max = 15 m) Inductive proximity switch incl. connecting cable, l = 5 m Connecting cables, supply, for M12x1 direct connection; neg. cable connector, 4 pin, IP67, with flying lead Length l = 0 m (connector only) Length l = 7 m (L min = 1 m/l max = 15 m) 2231A1 1500A45A0 1500A45A7 1500A45Asp The MultiFlow function cannot be controlled with the 5.7" touch display 5629A1. Accessories for CoMo Injection Basic: The functionality of the CoMo Injection Basic is limited by comparison with the CoMo Injection, but can be enhanced up to the full extent with the following options: Enhancement of the monitoring functions (integral, box, trapezium, threshold, etc.) Separation of individual cavities Real-time thresholds Data export to CoMo DataCenter Ordering Key (additional options for CoMo Injection Basic) Type 2806A Monitoring Function no 0 yes 1 Digital Outputs for Part Assignment and Multicomponent Support no 0 yes 1 Real-time Thresholds no 0 yes 1 Data Export to CoMo DataCenter no 0 yes 1 Power adapter 110... 240 VAC/24VDC 5781A2 MultiFlow Automatic Hot Runner Balancing MultiFlow software option for direct 2809A1 connection of hot runner controllers with interface (Kistler HRI) MultiFlow software option with protocol 2809A2 converter for connection of hot runner controllers without Kistler interface Custom protocol converter for connection 2808A1 of hot runner controllers without Kistler interface Hardware converter for Ethernet to RS-232C 2808A2 or RS-485 Page 10/12

Touch Display 12,1" SVGA and Accessories Touch display 12,1" SVGA Type/Art. No. 5629B3 Connecting cables for 12,1" touch display 12,1" Length l = 0,5 m 1200A103A0,5 Length l = 2 m 1200A103A2 Length l = 5 m 1200A103A5 Length l = 10 m 1200A103A10 Length l = 15 m 1200A103A15 Power adapter for 12,1" touch screen display 110 240 VAC/24 VDC for operation on network Network cables for operation on network Length l = 0,5 m Length l = 2 m Length l = 5 m (L min = 0,35 m/l max = 15 m) 5781A2 1200A105A0,5 1200A105A2 1200A105A5 1200A105Asp Connection system 4-channel connector for mounting 1708A... inside mold a) with mold identification 1708A1 (operating temperature range 125 C) b) without mold identification 1708A0 8-channel connector for mounting 1710A... inside mold a) with mold identification 1710A1 (operating temperature range 125 C) b) without mold identification 1710A0 1-channel extension cables Length l = 2 m Length l = 5 m (L min = 1 m/l max = 30 m) 1991A2 1991A5 1991Asp 4-channel adapter box, BNC to multiway cable 8-channel adapter box, BNC to multi-channel cable Adapter box, two 4-channel connections on mold to 8-channel cable Adapter box, 8-channel connection on mold to two 4-channel cables 4-channel connecting cables with flying lead for 0 ±10 V analog machine signals Length l = 0 m (connector only) Length l = 7 m (L min = 1 m/l max = 15 m) 5415A1 5415A2 5415A3 5415A4 1500A47A0 1500A47A7 1500A47Asp 4-channel extension cables for connecting thermocouple amplifier Type 2205A... or junction box Type 5689A10 Length l = 1 m 1457A1A1 Length l = 2 m 1457A1A2 Length l = 5 m 1457A1A5 (L min = 1 m/l max = 15 m) 1457A1Asp Thermocouple amplifier for 2... 4 Temperature sensors Type K, J, N Junction box for connecting 4 voltage signals 4-channel connecting cable for junction box/ temperature amplifier with flying lead Length l = 7 m (L min = 1 m/l max = 15 m) 2205A... 5689A10 1457B2A7 1457B2Asp 4-channel extension cables Length l = 1 m Length l = 2 m Length l = 5 m (L min = 1 m/l max = 30 m) 8-channel extension cables Length l = 1 m Length l = 2 m Length l = 5 m (L min = 1 m/l max = 30 m) 1995A1 1995A2 1995A5 1995Asp 1997A1 1997A2 1997A5 1997Asp Page 11/12

Ordering Key CoMo Injection Type 2869B Base Unit CoMo Injection Basic 4-channel with 0 1 x 4 charge* CoMo Injection 12-channel with 1 2 x 4 charge and 1 x 4 voltage CoMo Injection 12-channel with 2 1 x 8 charge and 1 x 4 voltage CoMo Injection 24-channel with 3 2 x 8 charge and 2 x 4 voltage Display Without Display 0 With touch display, 12,1", Type 5629B3 1 incl. cable Type 1200A103A2 With touch display, 12,1", Type 5629B3 2 incl. cable Type 1200A103A5 With touch display, 12,1", Type 5629B3 3 incl. cable Type 1200A103A10 With touch display, 12,1", Type 5629B3 4 incl. cable Type 1200A103A15 Power Supply With connector M12x1, 4 pin, 0 Type 1500A45A0 with power supply 1 110 240 VAC/24 VDC Type 5781A2 * With limited version of software, optional enhancement (see ordering key on p. 9) Windows, Windows XP, Windows 2000, Windows Vista and Windows 7 are registered trademarks of the Microsoft Corporation. Page 12/12