LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

Similar documents
Low Voltage alternators - 4 pole LSA 47.2

PARTNER ALTERNATORS LSA 40-4 Pole

TAL 049 Low Voltage Alternator - 4 pole

Low Voltage alternators - 4 pole LSA 46.2

TAL 047 Low Voltage Alternator - 4 pole

TAL 044 Low Voltage Alternator - 4 pole

LSA Pole. R 726 Mains paralleling

PARTNER ALTERNATORS LSA Pole

Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx

S4L1S-D4 Wdg.17 - Technical Data Sheet

S4L1D-G41 Wdg Technical Data Sheet

WDG 51 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 61 - Technical Data Sheet

S0L1-J1 - Technical Data Sheet

WDG 83 - Technical Data Sheet

WDG 07 - Technical Data Sheet

WDG 12 - Technical Data Sheet

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

WDG 71 - Technical Data Sheet

WDG 13 - Technical Data Sheet

WDG 12 - Technical Data Sheet

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Technical Data Sheet

PI734A - Technical Data Sheet

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PM734B - Technical Data Sheet. Generator Solutions AS

Low Voltage Alternators

Spec Information. Reactances Per Unit Ohms

GENERATOR DATA JANUARY 30, 2015

440 (12) 416 (12) 416 (12) 440 (12)

Spec Information. Reactances Per Unit Ohms

AGN 034 Alternator Reactance

Packaged Generators: New Kato Engineering Packaged Generator Line: Over 75 Years of Experience: Conformity: Service: Quality Standards:

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Generator Advanced Concepts

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Application Guidance Notes: Technical Information from Cummins Generator Technologies

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Target disk flowmeter for liquids and gases

R438 A.V.R. Installation and maintenance. This manual is to be given to. the end user CALL US TODAY POWER-58. SHOP ONLINE

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Low Voltage Alternators - 4 pole

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

R448 & R448 V50 A.V.R.

Technical Data Sheet for AvK-Alternators

EC centrifugal fan. forward curved, dual inlet with housing (flange)

AGN 005 Fault Currents and Short Circuit Decrement Curves

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

Technical Data Sheet for AvK-Alternators

Technical Data Sheet for AvK-Alternators

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

Impact Assessment Generator Form

EC centrifugal fan - RadiCal

Technical Data Sheet for AvK-Alternators

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

EC centrifugal fan - RadiCal

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL

STAR ELECTRIC COMPANY

Standard & Optional Items, Certifications and RFQ

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

SIMOTICS XP: Type series 1MD5 LOHER CHEMSTAR: Type series 1PS0, 1PS1, 1PS5 LOHER VARIO: Type series 1PS0, 1PS1, 1PS4, 1PS5

R241 A. 400 Hz A.V.R. Installation and maintenance. This manual is to be given to. the end user C B. Air craft p

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

EC centrifugal fan - RadiCal

APPENDIX B: Generation Interconnection Application Form

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

Split case double suction centrifugal pump. Technical data Serie: DPAS C

R448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A

Generation Interconnection Study Data Sheet Synchronous Machines

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

HCM634G - Technical Data Sheet

PART 1 OWNER/APPLICANT INFORMATION

R 450. AVRs. Installation and maintenance. This manual is to be given to. the end user R 450 VOLT. STAB. I EXC STAT. LEDS PMG

RS /M MZ SERIES

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

Modular equipment. Presentation, standards. Standard contactors TeSys GC

RoHS. High shaft load capacity. Shock / vibration resistant

KFS. Flap-type flow meter. Design and range of application

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

Embedded Generation Connection Application Form

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

Valves with a difference. Electrical Actuators DVC INTERNATIONAL

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

OPTIFLUX 1000 Technical Datasheet

K Factor Power Transformers

4939 en / a PARTNER ALTERNATORS LSA 54. General features and ratings

Transcription:

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole 30 to 30 kva - 0 Hz / 420 to 63 kva - 60 Hz Electrical and mechanical data

Adapted to applications LSA R and LSA H alternators are enclosed alternators (IP ). In the LSA R, cooling is performed by an air/air exchanger (cooling index: IC 6.A1.A1 in accordance with standard IEC 60034-6). In the LSA H, cooling is performed by an air/water exchanger (cooling index: IC 8.A1.W7 in accordance with standard IEC 60034-6). They are particularly suitable for demanding applications such as: Marine, Oil & Gas, etc. As an option, they can be ATEX (Explosive Atmosphere) certified in accordance with EEXem II T3 protection. Conform to international standards LSA R and LSA H alternators conform to the main international standards and regulations: - IEC 60034, NEMA MG 1.32-33, ISO 828-3, CSA / UL 1446 (UL 04 on request), marine regulations, etc. It can be integrated into a CE marked generator. They are designed, manufactured and marketed in an ISO 01 and ISO 14001 environment. Top of the range electrical performance Class H insulation Standard winding (3 wires + neutral), 6 wires, 2/3 pitch, type no. 6S Voltage range 0 Hz: 380V - 400V - 41V and 220V - 230V - 240V Voltage range 60 Hz: 380V - 416V - 440V - 480V and 220 V - 240 V High efficiency and motor starting capacity Other voltages are possible with optional adapted windings: - 0 Hz : 440 V (no. 7), 00 V (no. 9), 600 V (no. 22 or 23), 6 V (no. or 2) - 60 Hz : 380 V and 416 V (no. 8), 600 V (no. 9) R 791 interference suppression conforming to standard EN 011 group 1 class B standard for European zone (CE marking) Excitation and regulation system suited to the application Excitation system Volage regulator AREP Current transformer for paralleling Mains paralleling Regulation options 3-phase sensing Remote voltage potentiometer R40 Std C.T. R731 R734 DC Option C.T. included included contact us : possible mounting Protection system suited to the environment LSA R or LSA H alternators are equipped with space heaters and stator thermal protection (PT 0) The frame of LSA R & H exchangers is made of steel Depending on environments, several protection systems are available: - For the range LSA R (Air-cooled) in standard: Exchanger with steel or aluminium tube Options: Exchanger with stainless steel tube Exchanger with stainless steel tube and stainless steel end plates A complete stainless steel exchanger - For the range LSA H (Hydro-refrigerated): Land application / freshwater, non-saline atmosphere: Exchanger with single tube Cu (SF Cu F2) Marine application / seawater, saline atmosphere: Exchanger with double tube: Cu (SF Cu F2) outside tube and Cupronickel for inside tube Reinforced mechanical structure using finite element modelling Standard direction of rotation: clockwise as seen from the shaft end Compact and rigid assembly to better withstand generator vibrations Steel frame Steel endshields and cast iron spacers for air intake and outlet Two-bearing configuration Half-key balancing Regreasable bearings Accessible terminal box proportioned for optional equipment 1 terminal box on the left-hand side as seen from the shaft end and cables exiting downwards as standard Separation between the power and auxiliary circuits (space heaters + thermal protection) AVR and accessories to be mounted outside the terminal box by the installer ATEX certification for explosive atmospheres LSA R alternators are also available in an ATEX version for zone 2 in accordance with II 3G marking in EEx em II T3 protection mode. The alternators need to be certified by an external body, consult us for this certification. 2 Electric Power Generation

General characteristics Insulation class H Excitation system AREP Winding pitch 2/3 (n 6S) AVR type R 40 Number of wires 6 Voltage regulation (*) ± 0. % Protection IP Short-circuit current 300% (3 IN): s Altitude 00 m Total Harmonic Distortion THD (**) no-load < 4 % - on load < 4 % Overspeed 220 min -1 Waveform: NEMA = TIF (**) < 0 Waveform: IEC = FHT (**) < 2 % (*) Steady state. (**) Total harmonic distortion between phases, no-load or on-load (non-distorting). Ratings 0 Hz - 0 R.P.M. kva / kw - P.F. = 0.8 LSA R 49.1 LSA H 49.1 Duty / T C Continuous duty Continuous duty Class / T K H / 12 K F / K H / 12 K F / K Phase 3 ph. 3 ph. 3 ph. 3 ph. Y 380V 400V 41V 380V 400V 41V 380V 400V 41V 380V 400V 41V LSA 49.1 L2 kva 30 30 30 31 31 31 40 40 40 36 36 36 kw 280 280 280 22 22 22 324 324 324 2 2 2 LSA 49.1 L6 kva 43 43 43 3 3 3 0 0 0 4 4 4 kw 348 348 348 312 312 312 404 404 404 364 364 364 LSA 49.1 L9 kva 30 30 30 47 47 47 61 61 61 kw 424 424 424 380 380 380 4 4 4 444 444 444 Ratings 60 Hz - 1800 R.P.M. kva / kw - P.F. = 0.8 LSA R 49.1 LSA H 49.1 Duty / T C Continuous duty Continuous duty Class / T K H / 12 K F / K H / 12 K F / K Phase 3 ph. 3 ph. 3 ph. 3 ph. Y 440V 480V 440V 480V 440V 480V 440V 480V LSA 49.1 L2 kva 400 420 360 380 46 00 420 40 kw 320 336 2 304 372 400 336 360 LSA 49.1 L6 kva 480 2 430 470 60 6 0 0 kw 384 417 344 376 448 4 404 440 LSA 49.1 L9 kva 60 63 4 70 70 740 63 66 kw 484 07 436 46 64 08 32 The power ratings are given for the following conditions: LSAR: ambient temperature: 40 C to 0 C LSAH: water temperature: 32 C Electric Power Generation 3

Efficiencies 0 Hz - P.F.: 1 / 0.8 Efficiencies 60 Hz - P.F.: 1 / 0.8 93.2.2 LSA R 49.1 L2 9.1 P.F. : 1.6 P.F. : 0,8 93.3 93. % LSA R 49.1 L2 P.F. : 1.4 93.6 93.1 P.F. : 0,8. 91.7.8. 87.8 0 0 200 300 400 00 600kVA 89.2 93.8.7 93 9.3 9.9 P.F. : 1.7 P.F. : 0,8 0 0 200 300 400 00 600kVA.3 89.8.3 LSA R 49.1 L6 93.8.3 LSA R 49.1 L9 9.8.9.3 P.F. : 1 9.2 P.F. : 0,8 0 0 200 300 400 00 600kVA 86 84 8.6 8 0 0 200 300 400 00 600 700 kva % 86 % 86 LSA R 49.1 L6 9.2.4 93.6..8 86.7 86.2 P.F. : 1.2 P.F. : 0,8 0 0 200 300 400 00 600 700 kva LSA R 49.1 L9 P.F. : 1 9 9.7.8 93.2.2 P.F. : 0.8.6 87.6 0 0 200 300 400 00 600 700 kva Reactances (%). Time constants (ms) - Class H 0 Hz - Class H / 400V 60 Hz - Class H / 480V L2 L6 L9 L2 L6 L9 Kcc Short-circuit ratio 0.9 0.71 0.7 0.9 0.71 0.7 Xd Direct-axis synchro. reactance unsaturated 219 181 183 219 182 183 Xq Quadrature-axis synchro. reactance unsaturated 131 8 1 131 9 1 T do No-load transient time constant 1878 2047 2111 1878 2047 2111 X d Direct-axis transient reactance saturated 11.6 8.8 8.7 11.6 8.8 8.7 T d Short-circuit transient time constant 0 0 0 0 0 0 X d Direct-axis subtransient reactance saturated 9.3 7 6.9 9.3 7 6.9 T d Subtransient time constant X q Quadrature-axis subtransient reactance saturated 11.2 7.8 7. 11.2 7.9 7. Xo Zero sequence reactance unsaturated 0. 0.4 0. 0. 0.4 0. X2 Negative sequence reactance saturated.3 7. 7.3.3 7. 7.3 Ta Armature time constant 1 1 1 1 1 1 Other characteristics class H io (A) No-load excitation current 0.9 0.9 0.9 0.9 0.9 0.9 ic (A) On-load excitation current 2. 2.2 2.2 2. 2.2 2.2 uc (V) On-load excitation voltage 30 26 26 30 26 26 ms Response time ( U = 20% transient) 00 00 00 00 00 00 kva Start ( U = 20% cont. or 0% trans.) 1280 198 2372 1420 2482 2972 % Transient U (on-load 4/4) - P.F.: 0.8 LAG. 7.4 7.3. 7.4 7.3 W No-load losses 8980 42 11360 14300 16280 17620 W Heat dissipation 16 176 21378 240 2860 2786 4 Electric Power Generation

Efficiencies 0 Hz - P.F.: 1 / 0.8 Efficiencies 60 Hz - P.F.: 1 / 0.8 LSA H 49.1 L2 9.2 P.F. : 1.9 93.4 P.F. : 0,8 93.8 93.1.7 89.8 89 0 0 200 300 400 00 600 700 kva LSA H 49.1 L6.3 P.F. : 1 9.1 9 P.F. : 0,8.9.2 91.6 91 0 0 200 300 400 00 600 700 kva LSA H 49.1 L9.4 9..7 P.F. : 1 9..8 9.4 P.F. : 0,8.4 91.8 0 0 200 300 400 00 600 700 kva % 87.3 86 0 0 200 300 400 00 600 700 800 kva LSA H 49.1 L6 9. P.F. : 1.1.8 P.F. : 0,8. 93.4 89.8 86.6 89.3 LSA H 49.1 L2.7 P.F. : 1.1..9 93.2 P.F. : 0,8 91.6 0 0 200 300 400 00 600 700 800 kva LSA H 49.1 L9 P.F. : 1 9.9.4.7 9.4 9.1 P.F. : 0.8.1.8.3 0 0 200 300 400 00 600 700 800 kva Reactances (%). Time constants (ms) - Class H 0 Hz - Class H / 400V 60 Hz - Class H / 480V L2 L6 L9 L2 L6 L9 Kcc Short-circuit ratio 0.1 0.61 0.6 0.49 0.61 0.6 Xd Direct-axis synchro. reactance unsaturated 23 2 212 260 211 213 Xq Quadrature-axis synchro. reactance unsaturated 12 12 12 16 127 128 T do No-load transient time constant 1878 2047 2111 1878 2047 2111 X d Direct-axis transient reactance saturated 13.4.2.1 13.9.2.1 T d Short-circuit transient time constant 0 0 0 0 0 0 X d Direct-axis subtransient reactance saturated.7 8.1 8 11 8.1 8 T d Subtransient time constant X q Quadrature-axis subtransient reactance saturated 13 9 8.7 13.3 9.2 8.7 Xo Zero sequence reactance unsaturated 0.6 0.4 0.6 0.6 0.4 0.6 X2 Negative sequence reactance saturated 11.9 8.7 8. 12.2 8.7 8. Ta Armature time constant 1 1 1 1 1 1 Other characteristics class H io (A) No-load excitation current 0.9 0.9 0.9 0.9 0.9 0.9 ic (A) On-load excitation current 2.8 2.4 2.4 2.8 2.4 2.4 uc (V) On-load excitation voltage 33 29 29 33 29 29 ms Response time ( U = 20% transient) 00 00 00 00 00 00 kva Start ( U = 20% cont. or 0% trans.) 1280 198 2372 1420 2482 2972 % Transient U (on-load 4/4) - P.F.: 0.8 LAG 11. 8.1 8 11.8 8.2 8.1 W No-load losses 74 00 9860 1170 13820 30 W Heat dissipation 2289 21260 23180 2918 2676 284 Electric Power Generation

Transient voltage variation 400V - 0 Hz Loading (AREP system) 20 % L 2 1 L 6 Voltage drop L 9 0 0 0 200 300 400 00 600 700 800 0 00 kva kva at power factor 0.8 Load shedding (AREP system) 20 % L 2 L 6 1 L 9 Voltage rise 0 0 0 200 300 400 00 600 700 800 0 00 kva kva at power factor 0.8 Motor starting (AREP system) 30% L 2 L 6 L 9 2 Voltage drop 20 1 0 0 20 00 70 00 120 0 170 2000 220 200 kva kva locked rotor 1) For a starting P.F. other than 0.6, the starting kva must be multiplied by K = Sine P.F. / 0.8 2) For voltages other than 400V (Y), 230V (D) at 0 Hz, then kva must be multiplied by (400/U) 2 or (230/U) 2. 6 Electric Power Generation

Transient voltage variation 480V - 60 Hz Loading (AREP system) 20 % L 2 1 L 6 Voltage drop L 9 0 20 % 0 0 200 300 400 00 600 700 800 0 00 10 1200 kva kva at power factor 0.8 Load shedding (AREP system) L 2 L 6 1 L 9 Voltage rise 0 0 0 200 300 400 00 600 700 800 0 00 10 1200 kva kva at power factor 0.8 Motor starting (AREP system) 30% L 2 L 6 L 9 2 Voltage drop 20 1 0 0 20 00 70 00 120 0 170 2000 220 200 270 3000 kva kva locked rotor 1) For a starting P.F. other than 0.6, the starting kva must be multiplied by K = Sine P.F. / 0.8 2) For voltages other than 480V (Y), 277V (D), 240V (YY) at 60 Hz, then kva must be multiplied by (480/U) 2 or (277/U) 2 or (240/U) 2. Electric Power Generation 7

3-phase short-circuit curves at no load and rated speed (star connection Y) 0000 LSA R / H 49.1 L2 Current (A) 000 Symmetrical Asymmetrical 00 0 0000 1 0 00 000 0000 time (ms) LSA R / H 49.1 L6 Current (A) 000 Symmetrical Asymmetrical 00 0 1 0 00 000 0000 time (ms) Influence due to connection Curves shown are for star (Y) connection. For other connections, use the following multiplication factors: - Series delta : current value x 1.732 - Parallel star : current value x 2 8 Electric Power Generation

3-phase short-circuit curves at no load and rated speed (star connection Y) 0000 LSA R / H 49.1 L9 Symmetrical Asymmetrical 000 Current (A) 00 0 1 0 00 000 0000 time (ms) Influence due to short-circuit Curves are based on a three-phase short-circuit. For other types of short-circuit, use the following multiplication factors. 3-phase 2-phase L/L 1-phase L/N Instantaneous (max.) 1 0.87 1.3 Continuous 1 1. 2.2 Maximum duration (AREP/PMG) sec. sec. 2 sec. Electric Power Generation 9

LSA R dimensions Ø 740 +0 Ø 647.7-0.127 Ø 0 m6 20 Air outlet 16 20* 146 1831* 346* R 30* 16 M12 holes equid. on Ø 679.4 4x 686 80 820 80 6 28 16 30 2 +0 400-1 400 620* 30* 140* 20 6 40 140 240 62 Auxiliaries 11 90 Xg 93 L3 L2 L1N 1 1 8 240 Air intake 1 Cable exit 14 11 4 Ø3 holes 686 820 (*) for information only 11 Dimensions (mm) and weights (kg)* Type Xg Weight LSA R 49.1 L2 69 2281 LSA R 49.1 L6 716 26 LSA R 49.1 L9 73 281 NOTE : Dimensions are for information only and may be subject to modifications. Contractual 2D drawings can be downloaded from the Leroy- Somer site, 3D drawing files are available upon request. Electric Power Generation

LSA H dimensions Ø 740 +0 Ø 647.7-0.127 Ø 0 m6 20 30* 16 30* 20* 1672 * 1430 Water outlet Water inlet 30* 30* 7 16 M12 holes equid. on Ø 679.4 4x * 686 820* 6 Flange DIN 2633 Pn16 DN 32 * 28 16 222* 142* 220* 2 +0 400-1 400 1 800 4* 12* 20 6 40 140 240 Xg 62 Auxiliaries 11 90 93 L3 L2 L1N 1 1 8 240 Cable exit 14 4 Ø3 holes 11 11 686 820 (*) for information only Dimensions (mm) and weights (kg)* Type Xg Weight LSA H 49.1 L2 69 2000 LSA H 49.1 L6 716 2330 LSA H 49.1 L9 73 230 NOTE : Dimensions are for information only and may be subject to modifications. Contractual 2D drawings can be downloaded from the Leroy- Somer site, 3D drawing files are available upon request. Electric Power Generation 11

www.leroy-somer.com/epg Linkedin.com/company/Leroy-Somer Twitter.com/Leroy_Somer_en Facebook.com/LeroySomer.Nidec.en YouTube.com/LeroySomerOfficiel Nidec 2017. The information contained in this brochure is for guidance only and does not form part of any contract. The accuracy cannot be guaranteed as Nidec have an ongoing process of development and reserve the right to change the specification of their products without notice. Moteurs Leroy-Somer SAS. Siège : Bd Marcellin Leroy, CS 01, 1691 Angoulême Cedex 9, France. Capital social : 6 800 12, RCS Angoulême 338 67 28. 4083 en - 2017.12 / g