EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

Similar documents
MEMORY RECORDER/ANALYZER

DIS-5010A, DIA-512A. Data Acquisition System for Crash Test AUTOMOTIVE TEST EQUIPMENT

Dynamic Strain Amplifiers

WR300 SERIES. Direct Recording. Multi-Function. Direct Operation. Easy PC Connection. Thermal Arraycorders

WR300 SERIES. Direct Recording Chart, Internal Memory, 40GB HDD. Multi-Function Voltage / Temperature / Strain / Frequency

DM3100V2 Specifications

Portable Multi-Channel Recorder Model DAS240-BAT

EDX-5000A. Memory Recorder/Analyzer. High-speed sampling at 200 khz per 32 channels Simultaneous recording of video with a high-speed camera

User Manual CTP4/8/16

Telemetrie-Messtechnik Schnorrenberg

KMT - Kraus Messtechnik GmbH

Fast 10-ms Sampling Up to 600 Channels Data Logging. MEMORY HiLOGGER 8423

Fast 10-ms Sampling Up to 600 Channels Data Logging. Data Logger

Instrument. Specifications OR34/35. SmartRouter. 2 to 8 Channels Multi-Analyzers. Controller Unit TECHNICAL SPECIFICATIONS

Portable Data Logger with 30 Standard Channels Expandible to 60 Channels LR , LR , LR MEMORY HiLOGGER.

High-speed programmable attenuator MAT800

Signal Conditioning Amplifier

KMT - Kraus Messtechnik GmbH

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

Fast 10-ms Sampling Up to 600 Channels Data Logging. Data Logger

Acceleration Transducers

EX FEATURES. Stand-alone 48-channel unit with built-in Ethernet controller. Built-in bridge completion and Excitation

Kistler LabAmp for DynoWare

Features EX1629. High-performance Remote Strain Gage Measurement Unit. Overview. 48 programmable channels in a single unit

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

Portable Data Logger with 30 Standard Channels Expandible to 60 Channels LR , LR , LR MEMORY HiLOGGER.

Dx: Digital Multi-Channel Telemetry System

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

Impedance 50 (75 connectors via adapters)

CAEMAX D x telemetry. digital modular convenient. Modular, multi-channel telemetry system for a variety of applications. productive testing

Torque Station Pro TS-7700 System

Handheld 3.3GHz Spectrum Analyzer

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

Selective and broadband low frequency field analysis

Introducing the Portable Multi-channel Data Acquisition Recorder. MEMORY HiCORDER MR8875. User Guide

INTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection

Telemetrie-Messtechnik Schnorrenberg

APPA 300 Series. The Most User-Friendly High Performance Multimeter

MT32 Telemetry. KMT - Kraus Messtechnik GmbH. Multi channel telemetry system for rotating application. Powering (rotor) by battery or inductive

Series GLET Accessory for dataloggers series GL in modular enclosure

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN

Inductive Proximity Sensor

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Product and Measurement Solutions for the Automotive Industry

Digital Telemetry Solutions

Burst mode - This is incorporated to simulate simultaneous analog input. Compatible with a range of Application Development Environments

Models 296 and 295 combine sophisticated

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

1510A PRECISION SIGNAL SIMULATOR

Signal Input and Trigger

Spectrum Analyzers 2680 Series Features & benefits

MECE 3320 Measurements & Instrumentation. Data Acquisition

8248AU. 4-Ch Isolated Amplifier with Optional Bridge Conditioning FEATURES TYPICAL APPLICATIONS

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

PM 6669 High-Precision Frequency Counter Specifications


Portable Data Logger with 30 Standard Channels Expandible to 60 Channels LR , LR , LR MEMORY HiLOGGER.

Signal Conditioning Amplifier

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

Analog Signal Conditioning Accessories

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Reflectometer Series:

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

LOW NOISE AMPLIFIER SA SERIES

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

Digital Telemetry Solutions

Models 900CT & 900BT. Tunable Active Single Channel Certified Filter Instrument

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Model 3102D 0-2 kv H.V. Power Supply

Function Modules GL7- DISP GL7 - SSD GL7 - DCO. Datasheet. Function Modules. Voltage Output Module

Agilent U2500A Series USB Simultaneous Sampling Multifunction DAQ Devices

IMPEDANCE ANALYZER IM3570

Tablet Oscilloscope Data Sheet

SCP for Combustion Engines

AS-1250FE Datasheet Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis

2-channel models. 4-channel models

Agilent Technologies 3000 Series Oscilloscopes

1 GS/s Digital Oscilloscope Module

Wide-band Models from DC to 100 MHz

Acceleration Measurement And Analysis System SM-500

High-precision portable RESISTANCE METER

Wireless Neural Loggers

SDM3045X Digital Multimeter. DataSheet

Main Features. Highlights

Agilent Technologies 3000 Series Oscilloscopes

NEW! Transient Data Acquisition. Stand alone. Compact. Powerful.

FD 5 / 10 / 15. Fast acquisition module with universal synchronized inputs and embedded webserver software

Tuner Base Unit MB-8N. UHF Synthesized Tuner Unit WRU-8N

Fuel Cell Impedance Measurement System. KFM2150 system

TT7000R4. DS Instruments. D text. RF Power Meter, Signal Generator, Frequency Counter. -Key Features-

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

SCXI 8-Channel Isolated Analog Input Modules

SPIDER-80SG. General Data Acquisition Device with Strain Gage Measurement. Spider Measurement Solution

R-Log Radio data logger

Advanced Test Equipment Rentals ATEC (2832)

MEMORY HiLOGGER

MFD900. The most industrial ultrasonic test system for flaw detection and thickness measurements

Transcription:

KYOWA ELECTRONIC INSTRUMENTS CO., LTD. COMPACT RECORDER EDS-400A Compact Dynamic Strain Recorder Entering the scene in advanced measurement of strain, vibration, pressure, load, etc. New www.kyowa-ei.co.jp

Signal conditioners and 16-bit A-D converters are incorporated, 4 channels each, into a compact package to perform advanced measurement in limited spaces. The 4-channel EDS-400A is equipped with signal conditioners and 16-bit A-D converters to digitally record dynamic strain and voltage signals at high speeds. It can be set to desired recording conditions through either a PC connected to the LAN interface or a CF memory card inserted into the slot. The recorder amplifies and digitizes input signals, and then saves the results in the CF memory card. The PC, if connected to the LAN interface, enables monitoring of waveforms of the data being recorded. The acquired data can be transferred to the PC either on-line via the LAN interface or off-line via the CF memory card. The accessory software enables the PC to graphically display the data while the optional DAS-100A or NI DIAdem analysis software enables data analysis in various modes on the PC. Data is saved in CF card. LAN interface enables PC to control EDS-400A and to collect data. Control Software EDS-40A General Specifications Operating temperature range: 0 to 50 C Operating humidity range: 20 to 90 %RH (noncondensing) Vibration resistance: 49.03 m/s 2 (5 G), 5 to 55 Hz (when operating) Power source: 10 to 16 VDC; approx. 0.6 A (with 12 VDC supplied) Connector: Hirose RM12BRD-4PH Storage temperature range: 10 to 60 C Operating environment: No dust and no inductive noise from large-capacity motor, etc. Dimensions: 100 (W) x 50 (H) x 110 (D) mm (excluding protrusions) Mass: Approx. 500 g Hardware Specifications Number of measuring channels: 4 Input connectors: Tajimi R05-R5F Applicable plugs: Tajimi R05-PB5M Applicable sensors: Strain gages (4-gage system), strain-gage transducers, voltage-output sensors Applicable bridge resistance: 120 to 1000 Ω (4-gage system) Gage factor: 2.00 fixed Excitation voltage: 2 VDC Measuring range Strain: 6 steps of 1000, 2000, 5000, 10000, 20000 µm/m and OFF Voltage: 6 steps of 1, 2, 5, 10, 20 V and OFF Accuracy: Within ±0.5 %FS Balance adjustment (zero suppress): ON/OFF setting possible for each individual channel Adjusting method: True electronic method (saved in nonvolatile memory) Adjusting range Strain input: Resistance ±2 % (±10000 µm/m) or more Voltage input: ±10 V or more Max. input voltage: ±30 V (for voltage measurement) Frequency response range*: DC to 20 khz (deviation: +1 db, 3 db) Lowpass filter* *Characteristics of analog section Transmission characteristics: 2-pole (secondary) Butterworth Cutoff frequency: 20 Hz, 200 Hz, 2 khz or FLAT Accuracy of cutoff frequency: 3 db ±1 db Attenuation characteristics: 12 db ±1 db/oct. Resolution of A-D conversion: 16 bits Sampling method: Simultaneous sampling of all channels Sampling frequency: 1, 2, 5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 5, 10, 20, 50, 100 khz (16 steps) Note: Selectable number of channels is 2 for sampling at 50 khz, and 1 for sampling at 100 khz. Control switches: START/STOP, ZERO, READ Condition setting: Through either PC or CF card in which necessary conditions are written in advance Start/stop of recording: Through PC, panel key or external contact Zero suppress execution: Through PC, panel key or external contact LED annunciators POWER: Lights up when the power is ON. SYNC: Indicates synchronization status. MEAS: Lights up when recording is in progress. 1, 2, 3, 4: Indicate channel status. READ: Indicates the status of measuring conditions.

Minimal installation space required Palm-sized compact design Designed to be far smaller and lighter than KYOWA s forerunners, the 4-channel data logger can conveniently be carried for field tests and business trips. Options Point 1 Point 3 Control Software for Pocket PC Point 2 4 channels per unit Applicable to strain and voltage measurement Up to 8 units can be connected in cascade for 32-channel simultaneous measurement. Rear input connectors allow direct connection of sensors outputting strain and voltage signals. The control software enables a Pocket PC to set measuring conditions, suppress zero, start the EDS-400A recording, and monitor data in numeric and graphic formats. The Pocket PC may be either hardwired or wirelessly connected to the EDS-400A via LAN. Operating environment: Pocket PC 2003 Sampling at a maximum 100 khz Well suited to strength tests and vibration/noise measurement The maximum sampling frequency is 100 khz for 1-channel measurement and 20 khz for 4-channel simultaneous measurement. Thus, the EDS-400A can be utilized for various purposes including strength tests of car bodies and oil pressure measurement of engines and transmissions. Measured data is saved in CF card, enabling long-term measurement. (Pocket PC and telemetry LAN transmitter and receiver are not provided.) (Pocket PC, LAN interface card and LAN cable are not provided.) Operation modes Manual: A press of the START/STOP key starts it recording. The EDS- 400A stops recording when it completes recording in a preset number of measuring values or when the START/STOP key is pressed once again. Trigger: A press of the START/STOP key places the EDS-400A in standby condition and when the trigger condition is satisfied, it starts recording. The number of measuring values before the trigger point can be specified for recording. Trigger functions Trigger source: External trigger signal, analog input Trigger level: Can be set only for the analog trigger mode, in a plus/ minus full scale range. Trigger slope: Rise, fall or both to be specified Number of pretrigger data: Number of measuring values before trigger point can be specified for recording. Backup function: Setting conditions, balance adjustment parameters LAN interface: 10BASE-T/100BASE-TX Connector: RJ-45 modular jack Monitor display: Waveforms, bar graphs and numeric data can be monitored on the PC connected via LAN port. Data storage: CF memory card (128 MB to 1 GB) Synchronized operation: Dedicated synchronization cable enables cascade connection of up to 8 units for synchronized recording. The units connected in cascade record concerned data in the respective CF cards as separate files, which can be arranged in a single file on the PC after collection. Control Software Measuring condition setting functions Sensors: Strain gages, strain-gage transducers, voltage-output sensors Number of measuring channels: Max. 32 (with 8 units of EDS-400A connected in cascade) Sampling frequency: 1, 2, 5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 5, 10, 20, 50, 100 khz Measuring mode: Manual, analog trigger, external trigger Number of measuring values: Selectable in a range of 0 to 4294967295 (depends on the blank space of CR card) Setting to 0 lets the EDS-400A record to the full capacity of CF card. Measuring channel condition setting functions Selection of measuring channels: Possible Range: Selectable for each measuring channel Strain: 1000, 2000, 5000, 10000, 20000 µm/m or OFF Voltage: 1, 2, 5, 10, 20 V or OFF Lowpass filter: A cutoff frequency is selectable for each measuring channel from the following: FLAT (20 khz), 2 khz, 200 Hz and 20 Hz Calibration coefficient: A value by which every measured value is multiplied can be set for each measuring channel. Offset: An offset value which is added to every calibrated value can be set for each measuring channel. Engineering unit: Selectable from 60 kinds for each measuring channel. Input of an optional unit is also possible. Channel name: Can be input for reference. Zero suppress: ON/OFF setting possible for each measuring channel

4 5 6 Point Point Point Suitable as onboard logger Stand-alone operation possible The EDS-400A operates on 10-16 VDC. START/STOP and ZERO buttons are provided on the front panel to enable start/ stop of recording and zero suppress. Networked operation possible LAN interface provided standard A PC connected to the LAN interface can control the EDS-400A as well as monitor and collect measured data. Analysis software optionally available DAS-100A or NI DIAdem Collected data can be effectively and efficiently edited and analyzed using KYOWA s DAS-100A or the DIAdem software available from National Instruments. Major functions of DAS-100A: Cutting of necessary data section and editing FFT analysis, histogram analysis, differentiation/ integration Arithmetic operations, filtering, statistical operations Protector Kit EDS-PMF The protector kit is designed to not only protect the EDS-400A against shocks but also couple it with the ESB-04A battery box or join multiple units of the EDS-400A. Bridge Connectors Bridge connectors are required to connect strain gages to the EDS-400A. Remote Control Unit START/STOP, TRIGGER and ZERO buttons are provided to control the recorder from a distant location. Shown above is the EDS-400A coupled with the ESB-04A battery box, using EDS-PMF protector kits. Shown above are 2 units of the EDS-400A vertically coupled using EDS-PMF protector kits. Horizontal coupling is also possible. DB-120C-2R (right) (for 2-wire system) DB-120C-3R (left) (for 3-wire system) Usable for 1-element 120Ω gages. RCU-04A Other Options Strain input conversion cable, 30 cm long Voltage input cable, 1.5 m long Synchronization cable, 20 cm long AC adapter (100-240 VAC) Thermocouple measuring unit Enables the EDS-400A to measure temperature using a thermocouple. F-V converter Converts pulse-input frequency to voltage for measurement with the EDS-400A. Condition saving: Measuring conditions and measuring channel conditions can be saved in a condition file with a desired name. The saved condition file enables immediate setup for measurement with the same conditions as previous. Graph display of monitoring data: Monitoring data can be graphed as wave forms or bar graphs. Wave form graph: Monitoring data are graphed with the number of the data on X axis. The number can be set up to 1200, and a maximum 8 channels of data can be graphed with numeric values on the same display. Bar graph: Monitoring data of up to 8 channels are graphed with the channels on X axis. Numeric values are simultaneously displayed. Real-time graph: Recording data of up to 8 channels are graphed with the number of the data on X axis. Numeric values are simultaneously displayed. Measuring mode: Manual, analog trigger, external trigger Manual: A press of the START/STOP key starts the EDS-400A recording measured values in a preset number. If a PC is connected, sampling at 10 khz or less enables the PC to perform real-time data collection. Analog trigger: When a preset trigger level is reached in the designated channel, the EDS-400A starts recording measured values in a preset number. External trigger: An external trigger signal starts the EDS-400A recording measured values in a preset number. Data reproduction: Recorded data can be displayed in graphic format or converted to CSV format. Wave form graph: Data of up to 8 channels can be graphed as wave forms. Conversion to CSV format: A desired data section can be cut for saving in CSV format. Types of files Measuring condition file: Saved with an extension of E4C Measured data file: KYOWA standard format (extension: KS2) Operating Environment (PC) CPU: Pentium III 700 MHz or higher, or the equivalent OS: Windows 2000 (Professional)/XP (Professional, Home Edition) Memory: 256 MB or more Interface: 10BASE-T/100BASE-TX Hard disk: Blank space of 10 MB or more (for other than storage of measured data) Display: 1024 x 768 dots or more: full color CD-ROM drive: For installing the control software, etc. Standard Accessories DC power cable P-57, 128MB CF memory card, CD-R (control software EDS-40A and instruction manual)

Protector kit firmly guards the mainframe as well as facilitates connection of multiple units. Protector Kit Mounted on Mainframe Protector Kit EDS-PMF In combination with various sensors for automotive performance tests, safety confirmation and evaluation of riding comfort, the EDS-400A enables measurement and analysis of physical quantities such as acceleration, load, component force, moment and oil pressure. Examples of test results obtained by analysis software options DAS-100A Strain gage Bridge connector Directly connected Online data collection via LAN interface Voltage-output sensor Offline data collection Strain-gage transducer CF memory card

Dimensions Data Acquisition Time for Reference with 128MB CF Card (Standard Accessory) Sampling Frequency 100 khz 50 khz 20 khz 10 khz 5 khz 2 khz 1 khz 500 Hz 200 Hz 100 Hz 50 Hz 20 Hz 10 Hz 5 Hz 2 Hz 1 Hz Number of Measuring Channels 1 8 min. 16 min. 40 min. 80 min. 160 min. 6.6 hr. 13 hr. 26 hr. 2.7 days 5.5 days 11 days 27 days 55 days 111 days 277 days 555 days 2 8 min. 20 min. 40 min. 80 min. 3.3 hr. 6.6 hr. 13 hr. 33 hr. 2.7 days 5.5 days 13 days 27 days 55 days 138 days 277 days 3 13 min. 26 min. 53 min. 133 min. 4.4 hr. 8.8 hr. 22 hr. 44 hr. 3.7 days 9.2 days 18 days 37 days 92 days 185 days 4 10 min. 20 min. 40 min. 100 min. 3.3 hr. 6.6 hr. 16 hr. 33 hr. 2.7 days 6.9 days 13 days 27 days 69 days 138 days Reliability through integration Specifications are subject to change without notice for improvement. Safety precautions Manufacturer, s Representative Be sure to observe the safety precautions given in the instruction manual, in order to ensure correct and safe operation KYOWA ELECTRONIC INSTRUMENTS CO., LTD. Overseas Department: 1-22-14, Toranomon, Minato-ku, Tokyo 105-0001, Japan Tel: (03) 3502-3553 Fax: (03) 3502-3678 http://www.kyowa-ei.co.jp e-mail: overseas@kyowa-ei.co.jp Cat. No. 604B-U34 Printed in Japan on Recycled Paper 9/04 ocs