O NEILL SUBSTATION STAGE 02 CALIFORNIA

Similar documents
This specification describes the minimum technical requirements for drawings, as applicable to all disciplines.

Managing Hydropower Project Boundaries & Exhibit Drawings

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

TELEPHONE: (215) Addendum No Cooling Plant Replacement SDP Contracts No. B-080C, B-081C and B-082 of 2017/18

ADDENDUM No. 4 Page 1 of 8 (includes attachment)

Emergency responder radio coverage in new buildings. California Fire Code Section is hereby amended to read:

Guide Sign Policy for Secondary State Highways Edition

9. Pay for the power consumed until the project has been accepted as substantially complete.

A Bill Regular Session, 2017 HOUSE BILL 1926

03/7/12 Issuance UTD Section Page 1 of 5 Electrical General

For crossing under a railroad, contact the specific railroad company's engineering department.

CHAPTER 1: TITLE SHEET and GENERAL LAYOUT

SECTION 2 GENERAL REQUIREMENTS

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

ADDENDUM NO. 2. Furnace Bridge - Installation. Essex County, NY. July 29, 2015

ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Electrical/Telecommunications Design

2. Electrical rooms shall be centrally located and stacked so that feeder conduits and bus duct are run as straight and short as possible.

SECTION - II BID DATA SHEET

SECTION PANELBOARDS

SECTION 3 IMPROVEMENT PLAN REQUIREMENTS

COUNTY OF NORTHUMBERLAND Addendum No. 3 Request for Quotations To Renovate the Grafton Recreation Centre for a Licensed Child Care Centre

Section Meetings Section Material and Equipment. None Required

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

4. Special Systems Design: including Fire Alarm and Security. C. Electrical and Telecommunications Ductbanks: Refer to Section 16118

SPARTAN DAY CAMP 4814 FREEDOM RING RD

This section applies to the requirements for the performance of power system studies by both the Design Engineer and the Contractor.

WIRELESS TELECOMMUNICATION FACILITIES. Chapter 15

CHAPTER ELECTRIC AND MAGNETIC FIELDS

STATE OF TEXAS Agreement of Sale COUNTY OF TARRANT

November 16, 2017 BOARD OF COUNTY COMMISSIONERS ORANGE COUNTY, FLORIDA. Y CH / Addendum #6 SHERRY DRIVE BRIDGE REPLACEMENT

SECTION PROJECT COORDINATION VIA BIM

Storefront Installation Guide

Site Plan/Building Permit Review

Oakland County Michigan Register of Deeds Plat Engineering, GIS, & Remonumentation Dept. Ph: (248) Fax (248)

FOR LEASE MOTOR CAR PKWY TEMECULA CALIFORNIA UP TO 350,667 SF AVAILABLE

September 6, 2018 CITY OF BERKELEY SHATTUCK RECONFIGURATION AND PEDESTRIAN SAFETY PROJECT SPECIFICATION NO C ADDENDUM NO.

DEP 2008 ELECTRIC AND MAGNETIC FIELDS CHAPTER ELECTRIC AND MAGNETIC FIELDS

SECTION DISTRIBUTION SWITCHBOARDS

Software Services, Section 16748, Add as an attachment to this section Attachment A enclosed with this addendum.

Operating Standards Attachment to Development Application

Plan Submittal and Review Checklist

looking west looking east A0.6 Proposed Development Model Shots 1327 Marine Drive West Vancouver revision date fax (604) phone (604)

Construction Phase Project Management and Documentation

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

UNIFIED FACILITIES GUIDE SPECIFICATIONS

CLARK COUNTY FIRE CODE AMENDMENTS

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

CITY OF NEW ROCHELLE RENOVATIONS TO FIRE STATION NO WEBSTER AVENUE, NEW ROCHELLE, NEW YORK

THE HAWKINS HOUSE MANSION 549 COURT STREET RENO, NEVADA

OKLAHOMA CORPORATION COMMISSION OIL & GAS CONSERVATION DIVISION P.O. BOX OKLAHOMA CITY, OK (Rule 165:10-3-1) PERMIT TO DRILL

Dooley Dipping Vat Name of Property. Scott County, Arkansas County and State. S Form (Rev. 8-86) OMB No

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

JEFFERSON LAB TECHNICAL ENGINEERING & DEVELOPMENT FACILITY (TEDF ONE) Newport News, Virginia

Attachment A. BE IT ORDAINED by the Board of Supervisors of Chesterfield County:

WATER MAIN ALONG ENTRANCE TO ENCINO PS / HWY 281 TO ENCINO TANK Solicitation Number: CO Job No.:

CITY OF PINE CITY SMALL WIRELESS FACILITY DESIGN GUIDELINES

Electric Service Guide. Residential Subdivision

Simonson Design Lab, Inc. Design Agreement

[LLORW00000.L ER0000.LVRWH09H XL5017AP.WAOR Notice of Availability of the Record of Decision for the Proposed Vantage to

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

FOR LEASE PROFESSIONAL OFFICE SUITES

City of San José, California CITY COUNCIL POLICY

SECTION EMERGENCY RESPONDER RADIO COVERAGE SYSTEMS

CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS

VIRGINIA RAILWAY EXPRESS AMENDMENT OF SOLICITATION INVITATION FOR BIDS (IFB) ADDENDUM No. 3. Issued: February 23, 2016

B. Manufacturers: Square-D, G.E. or Westinghosue.

50-SDMS-01 SPECIFICATIONS FOR

ADDENDUM NO. 02 July 31, 2012

SECTION ELECTRICAL IDENTIFICATION

PRACTICE NOTE NO: 13 Version 1 Amended March 2001 Page 1 of 6 PRECAST CONCRETE ELEMENT DESIGN RESPONSIBILITIES AND CONTRACTUAL ARRANGEMENTS

PORTAGE COUNTY WATER RESOURCES DRAFTING STANDARDS. Date: January 26, 2001

Foundation Specifications for 5.6-Meter Modular Earth Station Antennas

Customer Connection Guide Updates Effective May 2017

City of Thousand Oaks

Foundation Specifications

b. Army Reserve Design Process Submittal Requirements (DPSR) c. USARC G-2/6 IT Design Whitepaper, 26 Jun 2012 ( ENCLOSURE 1)

Delivering Reliability. Services. Strength You Can Count On. oldcastleprecast.com/services

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

SAN ANTONIO WATER SYSTEM PURCHASING DEPARTMENT FORMAL INVITATION FOR BIDS ANNUAL CONTRACT FOR WELL MAINTENANCE SERVICES ADDENDUM NO.

Foundation Specifications for 7.6-Meter Modular Earth Station Antennas

SECTION PRE-MANUFACTURED CABINETS

PORT OF ST. HELENS SCAPPOOSE INDUSTRIAL AIRPARK PARALLEL TAXIWAY B RELOCATON AIP PROJECT ADDENDUM NO. 1

Introduction to Aerial Photographs and Topographic maps (Chapter 7, 9 th edition) or (chapter 3, 8 th edition)

Manholes Table of Contents

ADDENDUM NOTICE INTERIOR RENOVATIONS AT THE BATHURST CLARK RESOURCE LIBRARY, 900 CLARK AVENUE WEST, VAUGHAN, ON

James Luebke, PE Structural Development Engineer WisDOT Bureau of Structures

ADDENDUM NO. 3 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030

SUBMITTAL REVIEW Food Service Equipment Data Sheets GCAN. Notes: 1. See D-C Design comments. Submittal: No. 035.

TABLE OF CONTENTS. 1.0 Scope. 2.0 References. 3.0 Definitions. 4.0 Submission and Design Requirements. 5.0 Materials 5.1 General 5.

CITY OF OLIVETTE SITE PLAN AND COMMUNITY DESIGN REVIEW INFORMATION PACKET

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

David J. Gellner, AICP, Principal Planner

PART 4 - Public Land Mobile Radiotelephone Service Original Sheet 1 SECTION 2 - Nevada Bell 4.2 Nevada Bell Telephone Company

CHAPTER 10 MICHIGAN DESIGN MANUAL BRIDGE DESIGN (SI) SHOP DRAWING REVIEW TYPES OF SHOP DRAWINGS Structural Steel

2' x 3' Polymer Pull Box Cover 4'-0" 7'-0" 24" x 76" Access Opening 3'-6"

VI 3 - i TABLE OF CONTENTS

SPECIAL PROVISION Description of Project, Scope of Contract and Sequence of Work

SECTION SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES

2. As such, Proponents of Antenna Systems do not require permitting of any kind from the Town.

Transcription:

SECTION C DESCRIPTION/SPECIFICATIONS Spec. No. 769 O NEILL SUBSTATION STAGE 02 CALIFORNIA

O NEILL SUBSTATION STAGE 02 PROJECT DRAWINGS A. GENERAL: CONSTRUCTION STANDARD DRAWINGS: A complete set of standard drawings are available at http://www.wapa.gov/business/buys.htm. Construction drawings are the specification drawings and any additional drawings required for use in construction. The construction drawings will be issued after contract award and may include amendment changes and other details, which make the drawings suitable to use for construction purposes. PROJECT DRAWINGS: Project drawings included herein are reduced reproductions and are not to scale. Some project drawings show details of fabrication and other information not a part of the work. Disregard information and details, which are not applicable. STANDARD DRAWINGS: Where details shown on standard drawings included herein differ from project drawings or text, the details of project drawings or text shall govern. INFORMATIONAL DRAWINGS: Some project drawings have the words FOR INFORMATION ONLY appearing above the title block. These drawings show some information, which may be required for bidding purposes. These drawings do not show items to be furnished or work to be performed. EXISTING INSTALLATION DRAWINGS: Some project drawings have the words Existing Installation appearing above the title block. These drawings show the existing installations prior to modifications and may show some new work to be performed. REFERENCE DRAWINGS: Reference drawings referred to on project drawings and not included herein, are not necessary for bidding purposes. CONTRACTOR'S RESPONSIBILITY: Check all drawings and advise Western of any errors or omissions. B. LIST OF DRAWINGS: LOCATION MAP: 1. ONE 0015 Rev. A Location & Vicinity Map ELECTRICAL: 2. ONE 0001 Rev. A EI Switching Diagram (Existing Installation) 3. ONE 0001 Rev. B Switching Diagram 4. ONE 1000 Rev. B EI General Arrangement (Existing Installation) 5. ONE 1000 Rev. C General Arrangement 6. ONE 1100 Equipment and Material Index 7. ONE 1110 Rev. B EI Detail A and Sections A-A, B-B, C-C, D-D, E-E and F-F (Existing Installation) 8. ONE 1110 Rev. C Detail A and Sections A-A, B-B, C-C, D-D, E-E and F-F 9. ONE 1500 Rev. B EI Grounding Plan (Existing Installation) 10. ONE 1500 Rev. C Grounding Plan 11. ONE 1600 EI Station Service Wiring Diagram (Existing Installation) 12. ONE 1600 Rev. A Station Service Wiring Diagram 13. 805-D-1628 Electrical Installation Main Single Line Diagram 14. ONE 1630 EI Electrical Installation A.C. Single Line Diagram (Existing Installation) 15. ONE 1630 Rev. A Electrical Installation A.C. Single Line Diagram 16. ONE 1700 EI Conduit Plan (Existing Installation) 17. ONE 1700 Rev. A Conduit Plan 18. ONE 1700 Rev. B3 Conduit Plan (Shoo Fly-Installation - For Information Only) 19. ONE 1710 Cable Entry Box PB3 Plan and Sections 20. ONE 1715 Pull Box PB4 Plan and Sections 21. ONE 7500 Telephone Backboard Details 22. ONE T600 Rev. A Control Cable List FOUNDATION AND STRUCTURAL DRAWING INDEX: 23. ONE 2010 Foundation/Structural Data and Drawing Index CONCRETE: 24. ONE 2000 Rev. B EI Foundations General Plan (Existing Installation) 25. ONE 2000 Rev. C Foundations General Plan 26. ONE 2001 Rev A FIO Foundations Outline and Reinforcement (For Information Only) 27. ONE 2300 Foundations Outline and Reinforcement STEEL STRUCTURES: 28. ONE 2003 Rev. A EI Steel Structures 69kV Switch and Take-Off Structure (Existing Installation) 29. ONE 2003 Rev. B Steel Structures 69kV Switch and Take-Off Structure 30. ONE 2550 Anchor Bolts 31. ONE 2925 Equipment Cabinet Platforms Steel Design and Details

O NEILL SUBSTATION STAGE 02 PROJECT DRAWINGS STRINGING REQUIREMENTS: 32. ONE 2008 Rev. A FIO Stringing Requirements (For Information Only) SERVICE BUILDING: 33. ONE 3200 General Structural Notes 34. ONE 3201 Structural Foundation Plan 35. ONE 3202 Structural Foundation Sections & Details 36. ONE 3100 Rev. A Architectural Floor Plan 37. ONE 3101 Architectural Equipment and Material List 38. ONE 3300 Rev. A Mechanical HVAC Floor Plan 39. ONE 3400 Rev. A Electrical Power Plan 40. ONE 3401 Rev. A Electrical Lighting Plan 41. ONE 4000 Rev. A Service Building Electrical Arrangement, Conduit, & Grounding 42. ONE 4001 70kV Vertical Switchboard Sections CHA1 through CHA4 Panel Arrangements 43. ONE 4002-1 70Kv Vertical Switchboard Sections CHA1 through CHA4 Bill of Materials (Sheet 1 of 2) 44. ONE 4002-2 230kV Vertical Switchboard Sections CHA1 through CHA4 Bill of Materials (Sheet 2 of 2) 45. ONE 4003 70kV Vertical Switchboard Sections CHA1 through CHA4 Side Sheet Arrangements 46. ONE 4004-2 Vertical Switchboard Section CHA1 Nameplate List (Sheet 2 of 2) 47. ONE 4005-2 Vertical Switchboard Section CHA2 Nameplate List (Sheet 2 of 2) 48. ONE 4006-2 Vertical Switchboard Section CHA3 Nameplate List (Sheet 2 of 2) 49. ONE 4007-2 Vertical Switchboard Section CHA4 Nameplate List (Sheet 2 of 2) 50. ONE 6006 Rev. A DC Distribution Panel BHA

Luis Ave Plaza Dr Leota Rd 1 Fahey Rd Whitworth Rd Cherokee Rd O'Neill Substation Merced County O'Neill Facility/Substation Access Road Facility Boundary O'Neill Saturn St W Comet Rd E Comet Rd 33 5 5 Henry Miller Rd 1 2 3 4 5 6 7 8 9 1:24,000 1 inch = 2,000 feet Adjoining 7.5' Quadrangle Names Center quad is this site 1. Crevison Peak 2. Howard Ranch 3. Ingomar 4. Pacheco Pass 5. San Luis Dam 6. Volta 7. Mariposa Peak 8. Los Banos Valley 9. Ortigalita Peak NW Site Coordinates Lat: 37 5' 54.297" N Long: 121 2' 53.995" W 0 0.25 0.5 0.75 1 Miles Deleon Ave State Hwy 33 Western Area Power Administration - O'Neill Substation O'Neill Substation is on the SE end of the O'Neill Pumping Plant, which is west of Santa Nella, CA 95322. The two nearest Interstate Highway I-5 exits are #403 & #407. Latitude: 37 deg 5 min 54.30 sec N Longitude: 121 deg 02 min 53.99 sec W Driving directions from Sacramento, California: Take Interstate Highway I-5 south to the California CA-33 exit (Exit 407), turn right (south) onto Santa Nella Road/CA-33 and go to the second canal crossing approximately 1 mile from the turnoff, to the access road gate on the south side of the canal. When at the gate call the delivery contact person for access and guidance to the substation site. The successful Contractor shall contact the delivery contact person for updated and detailed immediate vicinity directions. Primary Delivery Contact: Charles Forbes Phone No. 209-833-3040 Mobile Phone No. 209-247-8071 Email: forbes@wapa.gov UNITED STATES DEPARTMENT OF ENERGY WESTERN AREA POWER ADMINISTRATION SIERRA NEVADA REGION - FOLSOM, CALIFORNIA DESIGNED O'NEILL SUBSTATION CALIFORNIA WAPA Official Use Only May be exempt from public release under the Freedom of Information Act (5 U.S.C. 552), Exemption 3 and 6 U.S.C. 133 (Domestic Security, Critical Infrastructure Information). This information is voluntarily submitted to the Federal Government in expectation of protection from disclosure as provided by the provisions of the Critical Infrastructure Information Act of 2002. Western review required before public release. Name/Org: Date: This map and data are the property of WAPA/DOE and are intended for planning and analysis only. No reproduction or copying of this product is allowed without the sole consent of WAPA/DOE. To contact WAPA about this map, please call 1-800-336-7288. This cartographic product and GIS data were prepared in accordance with professional practice standards. The data represented on this map has been developed from the best available sources. Although efforts have been made to ensure that the data is accurate and reliable, errors may be reflected in the data. Users must be aware of these conditions and bear responsibility for the appropriate use of this map. The data on this map is for reference use only. VICINITY MAP Steve Tuggle APPROVED G IS JULY 16, 2013 ONE 0015

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

FOR INFORMATION ONLY 18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

Ω 43

44

45

46

47

48

49

50