Kerman & Kavian Cable Industries ( KCI )

Similar documents
INTERNATIONAL STANDARD

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

FLAME RETARDANT INSTRUMENTATION CABLE. Application Standard

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4


SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

The Quality Connection. ICON Product Guide

MarineLine YOZp 0,6/1 kv

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

Product information. Marine, Oil & Gas.

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

Instrumentation Cable PLTC/ITC and TC Types

Armoured Power and Control Cables to BS7917

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

EDS LV WAVEFORM MAINS CABLE RATINGS

Notes 3 Explanatory Information 4-10

ABOUT US ABOUT US 1 CRANE CABLES

Armoured Power and Control Cables to BS6883

Armoured Power and Control Cables Fire Resistant

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :

P Low Voltage Catalogue Cables Australia Powering your Project

CIR (Crush & Impact Resistant) VFD Power Cable

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

Armoured Instrumentation Cables to BS6883

SANS 1339:2010 Electric cables Cross-linked polyethylene (XLPE) insulated cables for rated voltages 3,8/6,6 kv to 19/33 kv

CUSTOM DESIGN COAXIAL CABLES BY SICAB

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

Caledonian. VG Series. Caledonian Navy Cables.

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

How to order. Payment options. Delivery options. Online acatalog. By phone + (44) By fax + (44)

non-sheathed cables for fixed Wiring integrity is doing the right thing, even if nobody is Watching JiM stovall

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Medium Voltage Power Cables

Standards Update Notice (SUN) Issued: June 6, 2017

Tratos High Voltage cables

Fault location on power cables. Fault location on power cables

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

Cables for data transmission in industrial automation

Instrumentation Cables

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

(12) Patent Application Publication (10) Pub. No.: US 2015/ A1

Premoulded cable joint SMPGB

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

MV water-proof and water tree retardant power cable

EDS KV TRIPLEX CABLE RATING

MEDIUM VOLTAGE

Marine Cables General Catalogue

Medium Voltage YOUR ENERGY, OUR SYSTEMS, ANYWHERE

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

Contents. Introduction 3 Cable Components 4 Cable Handling 8 Health, Safety and Environment 9 Quick Reference Guide 10 Underground Mining - Coal 12

COPPER + LWL RAW CABLES

Content. - DDF Frame Pair Screen Cable Pair Screen Cable

Installation Recommendations

Technical Specification. for 1.1 KV Copper Control Cable

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

SUPERIOR MARINE CABLE SOLUTIONS

Power Cables and their Application

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

REPORT OF PERFORMANCE TIC

List Price w.e.f. 02nd January, 2018

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

Date: / TECHNICAL SPECIFICATIONS FOR 11 KV XLPE INSULATED UNDERGROUND CABLES

Underground System Design TADP 547

FLEXIBLE MULTI CORE CABLES

NETWORK CONNECTIVITY SYSTEMS

HV SYSTEMS. Prysmian HV Systems Product Range 66kV & 132 kv

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

XLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

GEXOL WORLD CLASS OIL & GAS CABLES

IEC Standard Caledonian Offshore & Marine Cables

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

UNCONTROLLED 3 STANDARD PROCEDURES FOR PREPARING 33KV CABLES

Control Cable. 1 Executive Standards. 3 Type and Designation. PVC insulated PVC sheathed control cable. PE insulated PE sheathed control cable

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Addison Medium Voltage Cables

15 years of experience

Specification for pvc-insulated cables for electricity supply

Chapter Seven. Under Ground Cables

CERTIFICATE OF CONFORMANCE

MULTIMEDIA & DATA TRANSMISSION

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Selection table for flat & ribbon cables

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

FieldLink MC at 20 x outer diameter Torsion

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

Tri-Rated Flexible PVC Equipment Wire

Field Instrument Cable. Electrical Noise

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

VSD cables in. Working with. industrial & automation applications

conductor Extruded Cross - Linked Polyethylene Insulated (XLPE) Power Cable Rated Voltage U 0 /U = 12/20 kv U 0 /U = 18/30 kv

Technical cable guide

Transcription:

KCI

Kerman & Kavian Cable Industries ( KCI )

KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376:

Kerman & Kavian Cable Industries ( KCI ) A Summary of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) KCI Scope and object : This part of IEC 60092 is applicable to screened and unscreened cables for control and instrumentation circuits on ships and offshore units. The cables have extruded solid insulation with a voltage rating of 150/250V (300V) and are intended Rated voltage : The standard rated voltage Uo/U (Um) is as follows: U O /U (UM) = 150 V/250 V (300 V) a.c. In the voltage designation of cables ; UO : is the rated power-frequency voltage between the conductor and the earth or metallic covering for which the cable is designed; U : is the rated power-frequency voltage between conductors for which the cable is designed. UM : is the maximum value of the highest system voltage for which the equipment may be used. A d.c. voltage up to a maximum of 1.5 times the a.c. voltage may be used, provided that the voltage to earth does not exceed 250 V. 1 ) Conductors : The material, metal coating, separator, class and form of the conductors shall be in accordance with IEC 60092-350 and shall be circular Class 2 or Class 5 constructions of cross-sectional area 0.50 mm 2, 0.75 mm 2, 1.0 mm 2, 1.5 mm 2 or 2.5 mm 2. Note : The preferred conductor sizes are 0.75 mm 2 and 1.5 mm 2. Instrument Cables Nominal cross section of conductors (mm 2 ) Class 2 Stranding Class 5 Stranding DC resistance of (conductors) plain copper tinned copper plain copper tinned copper Ohm/kM at 20 C 100 0.5 40.4 41.6 41.4 42.5 0.75 26 26.3 27.6 28.3 1.0 19.2 19.3 20.7 21.2 1.5 12.8 12.9 14.1 14.5 2.5 7.86 8.02 8.47 8.71

2 ) Insulation system The insulation system shall consist of either; KCI 2-1 ) one of the insulating compounds indicated in following Table 2-2) a combination of one or more layers of inorganic tape(s) and a layer of one of the insulating compounds indicated in following Table (example Mica-Glass Tape + XLPE ) 2-1) An Insulated Conductor 2-2) A Conductor Insulated by by Mica-glass and an extruded Insulation Kerman & Kavian Cable Industries ( KCI ) Used as insulation of Fire-Resistance Cables Instrument Cables Nominal cross section of conductors PVC/A EPR XLPE HEPR HF 85 S 95 mm 2 mm mm mm mm mm mm 0.5 0.6 0.6 0.4 0.4 0.6 0.6 0.75 0.6 0.6 0.5 0.5 0.6 0.6 1.0 0.6 0.6 0.5 0.5 0.6 0.6 1.5 0.7 0.7 0.6 0.6 0.7 0.7 2.5 0.7 0.7 0.6 0.6 0.7 0.7 PVC : Poly vinyl chloride XLPE : Cross-linked Polyethylene 101

3 ) Cabling KCI Kerman & Kavian Cable Industries ( KCI ) 3-1 ) Core assembly (multicore cables) The individual cores shall be twisted together in concentric layers. 3-2 ) Forming pair, triple or quad units ; Cores shall be twisted together with either a left hand or right hand lay to form a pair, triple or quad unit. The lay length of the cores individually or collectively screened shall not exceed 120 mm for sizes below 1.5 mm2 and 150 mm for sizes 1.5 mm2 and above. Core (Unit) Pair (Unit) Triple (Unit) 3-3 ) Typical colour code for single unit cables Unit element Wire a Wire b Wire c Wire d 4 ) Electrostatic screen Pair unit Black White - - Triple unit Black White Red - Quad unit Black White Red Blue 3-4 ) Number of cores It is recommended that the number of cores shall be selected from one of the following: 2, 4, 7, 12, 19, 27, 37. 3-5 ) Number of pair, triple or quad units It is recommended that the number of pair units shall be selected from one of the following: 1, 3, 7, 12, 19, 27, 37. Instrument Cables 102 4-1 ) Individually taped screened pair, triple or quad constructions When an individual taped screened pair, triple or quad construction is required, each pair, triple or quad shall have a laminated electrostatic screening tape applied with the metallic side in electrical contact with a drain wire. The nominal overlap shall not be less than 25 %. The laminated electrostatic screening tape shall be either aluminium bonded to polyester having a minimum thickness of aluminium of 0.008 mm and a minimum thickness of polyester of 0.010 mm, or copper bonded to polyester having a minimum thickness of copper of 0.018 mm and a minimum thickness of polyester of 0.023 mm. The drain wire shall be composed of a number of strands of tinned annealed copper wires in the case of aluminium laminate tape and either plain or tinned annealed copper wires in the case of copper laminate tape.the drain wire shall have a maximum resistance in accordance with following Table. Pair (Unit) Individually Screened in Metallic Foil (PiMF) Triple (Unit) Individually Screened in Metallic Foil (TiMF)

KCI 4-2 ) Individually braided screened pair, triple or quad constructions When an individual braided screened pair, triple or quad construction is required, each pair, triple or quad shall have a non-hygroscopic separator tape applied over the cores and under the braid. The nominal overlap shall not be less than 25 %. The braid shall be either plain or metal coated copper wires; the minimum diameter of the braid wire shall be: When required, to aid termination, a drain wire may be applied under and in direct contact with the braid screen.the drain wire shall be composed of a number of strands of tinned or plain annealed copper wires. The drain wire shall have a maximum resistance in accordance with following Table. Nominal cross section of conductors Maximum drain wire resistance mm 2 Ohm/km 0.5 61.2 0.75 42.5 1.0 28.3 1.5 28.3 2.5 21.2 Braid (Screen) Static Tape (Screen) Kerman & Kavian Cable Industries ( KCI ) 4-3 ) Collectively screened constructions Similar to 4-1) and 4-2) ; both taped and braided screen s type is permitted. 5 ) Metal braid armour In this standard the braid wires are either: zinc coated (galvanised) steel, or copper (plain or tinned), Note : In the case of plain or tinned copper wire braids, these may also provide the function of an electrostatic collective screen providing they are terminated to earth. Zinc coated (galvanized) Steel wires Braid Plain Copper wires Braid Tinned Plain Copper wires Braid Instrument Cables 6 ) Sheath(s) Could be one of following materials ; PVC, PE, Halogen Free. Note : The sheath may be of other colours, thereby providing a visual difference to that of LV and MV Power cables. 103