EWP Product Guide. For Use With Products Manufactured by. TJI 110, 210, 230, 360, & 560 Joists.

Similar documents
For Use With Products Manufactured by

EWP Product Guide. For Use With Products Manufactured by THF23140 LSSH179 SKH1720L

EWP Product Guide. For Use With Products Manufactured by. Corona Westampton Largo Montgomery Humble Thornhill, Ontario THFI2514

For Use With Products Manufactured by

Backer Block (both sides) of web with single RFPI Joist. (12) - 10d. Backer Block. each side. 2 min. 2 min.

LSSH179 THF17925 THO17118

EWP Product Guide. For Use With Products Manufactured by.

EWP Product Guide. For Use With Products Manufactured by. BCI I-Joists. Canadian Specifiers Guide. USPconnectors.com LIMIT STATES DESIGN SKH2520R-2

EWP Product Guide. For Use With Products Manufactured by. Canadian Specifiers Guide. USPconnectors.com LIMIT STATES DESIGN SKH2520R-2 LSSH35 THFI2514

CONNECTOR SELECTION GUIDE


CONNECTOR SELECTION GUIDE

CONNECTOR SELECTION GUIDE

4) Verify that the size of the supporting member can accommodate the connector s specified fasteners.

Featuring TJ Rim Board and TimberStrand LSL

T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs

RIDGE-JOIST CONNECTION 12/12 maximum slope

Wood I-Joists by Curtis Eck, P.E.

ROOF SYSTEM DESIGN GUIDE

Main Floor Revisions: 38' 0" Rm1 H3 50' 0" Bk1 B1 Rm2 B5 (26)-2 H2 B2 H3 (3)-3 B3 (11)-4 Bk1 B1 (5)-5 Rm4 Bk1 Rm3 Bk1 24' 0" 6' 0" 20' 0" START FRAMIN

APA Performance Rated Rim Boards

VERSA-LAM BCI INSTALLATION GUIDE LIMIT STATES DESIGN CANADA

SEALANT ACCESSORY CONTROL, NOT COMPROMISE. Low VOC Do-All-Ply Sealant

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

THE ENGINEERED WOOD ASSOCIATION

Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7

MAT105: Floor Framing

Connection Philosophy. p NDS Chapter-by-chapter description Changes from previous editions Examples. Part 1: Member Design Webinar.

Wood Connections. Concepts of Well Designed Connections

SDWH TIMBER-HEX Screw

VERSA-LAM. An Introduction to VERSA-LAM Products

Load Tables, Technical Data and Installation Instructions

3.1 General Provisions

INSTALLATION GUIDE FOR FLOOR AND ROOF FRAMING

INSTALLATION GUIDE FOR FLOOR AND ROOF FRAMING

Residential I-Joist & LVL INSTALLATION GUIDE

IRC 2015 Code Compliant Wood Framed Residential Details. Incorrect Installations of Connectors with code references and remedies, discussion.

FRAMING DETAILS FOR FLOOR AND ROOF

Structural Criteria for Residential Flush-Mounted Solar Arrays

TJI 110, TJI 210, TJI 230,

Designed for Building Designed for Living

WARNING: JOISTS ARE UNSTABLE UNTIL BRACED LATERALLY BRACING INCLUDES:

SECTION ROUGH CARPENTRY

LP SolidStart LSL. LP SolidStart LSL Prescriptive Roof Framing Technical Guide 2500F b-1.75e, 2360F b -1.55E and 1730F b -1.

Structural Criteria for Residential Rooftop Solar Energy Installations

PV System Structural Criteria

TRUS JOIST TJI. Featuring Silent Floor Joists for Residential Applications. Uniform and Predictable. Lightweight for Fast Installation

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California / 16

Shearwall System Installation Guide

Dura-Lock Roof System

TRUS JOIST TJI. Featuring Silent Floor Joists for Residential Applications. Uniform and Predictable. Lightweight for Fast Installation

TJI 210 TJI TJI 360 TJI 560 JOISTS

Structural Criteria for Residential Rooftop Solar Energy Installations

Attach Trusses and Rafters Faster

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

IRC 2012 Code Compliant Wood Framed Residential details. Miss Installed Connectors with code references and remedies, discussion.

installation Guide What you don t Safety I-Joist Storage and Handling United states Installation Instructions for Residential Floor Systems

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year.

PART II ENGINEERED BASIS OF RIDGE AND EAVE VENT DETAILS

ONE AND TWO FAMILY DWELLINGS Uncovered Decks July, 2007

Heartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785)

METALWORKS Concealed. Installation Instructions

Designed for Building Designed for Living

Unirac Installation Manual

SD Screw #10x2½" 16dx2½" SD Screw #9x2½" SD Screw 10dx1½" 8d Common N54A 0.25" 0.131"

Dave's Glossary of Construction Terms. by Dave Osborne (

ICBO ES ER-5598 n HUD MR 1310 DSA PA-123 n LAC RR25448 n CCMC R. Limit States Design

5 5 8 " 60" 53 8 " " 7" 5 1 2" 7" " FIVE MODELS TO MEET YOUR DESIGN REQUIREMENTS.

A. Rough carpentry includes but is not limited to the following:

Connectors for Cold-Formed Steel Curtain-Wall Construction

Best Barns USA. the Brookhaven 10' x 16' Assembly Book. revised March 23, 2016

TJI 110, TJI 210, TJI 230, TJI 360, TJI 560 AND TJI 560D JOISTS

Wood Connections. Presented by: Karyn Beebe, P.E.

LP SolidStart Laminated Strand Lumber and Laminated Veneer Lumber Louisiana-Pacific Corporation Revised May 6, 2011

INSTALLATION TORSION SPRING FRONT OR REAR MOUNT LOW HEADROOM. 1 Cutting Vertical Track. 2 Fully Adjustable Jamb Brackets

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: EVALUATION SUBJECT:

2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

KOLO SHELTER Installation Instructions Parts List

Site Installation Guide

Section Downloads. Terminology Outline. Industry Standards/ Publications. American Softwood Lumber Standard ANSI/TPI 1. Section 02: Terminology

Vertical Offset Base and Safety Rail System Installation Instructions

(800) (562) A Subsidiary of the International Code Council

ROOF-CEILING CONSTRUCTION

Chapter 33: Lofts (Or Second Floors)

FASTENERS BUILDING DEPARTMENT

TJI 110, TJI 210, TJI 230,

Timber to Timber - Timber to Concrete - Timber to Steel

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam

City of Virginia Beach, Virginia Typical Deck Details

24" max from each end of the ledger. See detail 6A & 6B, typ. both ends IRC R Ledger R507.2

Connectors for Cold-Formed Steel Curtain-Wall Construction

Pocket Door Kit PD1 / PD2 Installation Instructions. Kit Contents.

APPLICATION FOR A BUILDING PERMIT

Transcription:

EWP Product Guide www.connectors.com For Use With Products Manufactured by SKH2324R-2 LSSH179 THF17925 THO17118 TJI 110, 210, 230, 360, & 560 s supplies quality products to build Stronger Safer Structures Rancho Cucamonga Livermore Montgomery Houston Largo North Wilkesboro Hainesport 945-041

Customer Service / Technical Assistance Livermore, CA Office Montgomery, MN Corporate Office Largo, FL Office 1-800-227-0470 1-800-328-5934 1-800-443-6442 Follow these instructions to ensure the proper installation of products. General Notes 1) See current Full Line Catalog for General Notes, Warranty, and installation information for hanger models, joist sizes, and header situations not shown. 2) Loads listed address hanger/header/fastener limitations as well as joist/hanger limitations assuming header material is Douglas Fir-Larch (DF-L), Southern Pine (SP), or Microllam LVL, Parallam PSL, or TimberStrand LSL. reaction should be checked by a qualified designer to ensure proper hanger selection. 3) Uplift loads have been increased 33% for wind or seismic loads and no further increase shall be permitted. Reduce loads according to code for normal duration loading such as cantilever construction. 4) If hanger height is less than 60% of joist height, joist rotation may occur, therefore supplemental lateral restraints are required, see page 3. 5) The type and quantity of fasteners used to install products is critical to connector performance. To achieve the allowable loads shown in this catalog, install with the fasteners specified for that particular product. All specified fasteners must be properly installed prior to applying load of any kind to the connection. 6) Throughout this guide, dimensions are expressed in inches and loads in pounds, unless specifically noted otherwise. 7) Load values for 10d and 16d designations in the fastener schedules throughout this catalog refer to common wire nails, unless noted otherwise. 8) The allowable loads shown in this catalog are based on Allowable Stress Design methodology. 9) Multiple TJI Plies: Fasten together multiple plies of wood TJI s, in accordance with Trus s installation guidelines, such that the joists act as a single unit. 10) Sloped TJI s: Use sloped seat hangers and beveled web stiffeners whenever the slope exceeds the following: 1 2:12 for seat bearing lengths of 2 1 2 or less; 3 8:12 for bearing lengths between 21 2 and 3 1 2 ; and 1 4:12 for bearing lengths in excess of 3 1 2. Backer Blocks Pattern the nails used to install backer blocks or web stiffeners in wood TJI s to avoid splitting the block. The nail pattern should be sufficiently spaced to avoid the same grain line, particularly with solid sawn backer blocks. Backer blocks must be installed on wood TJI s acting as the header, or supporting member. Install in accordance with the Trus s installation guidelines. The nails used to install hangers mounted to a TJI header must penetrate through the web and into the backer block on the opposite side. Filler Block Installation: Nail with ten 10d (3 ) box nails, clinched. Use ten 16d (31/2 ) box nails from each side with TJI 560 joists. Backer Block Installation: Install tight to top flange (tight to bottom flange with face mount hangers). Attach with ten 10d (3 ) box nails, clinched when possible. Backer Block (both sides) of web with single TJI. Gap 1/4 Gap 1/4 With top flange hangers, backer block required only for downward loads exceeding 250 lbs or for uplift conditions Filler and Backer Block sizes TJI Depth Filler Block* 2x6 2x8 2x6 + 3/8 Cantilever Filler 9-1/2 or 11-7/8 2x6 4'-0 long 110 210 2x10 6'-0 long 9-1/2 or 11-7/8 2x6 + 3/8 4'-0 long or 16 2x8 + 3/8 2x10 + 3/8 6'-0 long 9-1/2 or 11-7/8 2x6 + 1/2 2x6 + 1/2 4'-0 long 230 or 360 or 16 2x8 + 1/2 2x10 + 1/2 6'-0 long 11-7/8 560 Two 2x6 Not applicable or 16 Two 2x8 (10) - 10d box Backer Block each side Backer Block* 5/8 5/8 3/4 3/4 1 net 1 net 2x6 2x8 *If necessary, increase filler and backer block height for face mount hangers. Maintain 1/8" gap at top of joist; see web stiffener attachment details. Filler and backer block dimensions should accommodate required nailing without splitting. 2 Typical THF backer block installation Typical THO backer block installation Gap 1/4 Web Stiffener Attachment for TJI s Web stiffener each side (1): TJI 110 joists: 5/8 x 25/16 minimum. TJI 210 joists: 3/4 x 25/16 minimum. TJI 230 and 360 joists: 7/8 x 25/16 minimum. 1 1 Gap: 1/8 minimum 2 3/4 maximum Three 8d (2 1/2 ) box nails, clinched Tight 1 1/2 TJI 560 joists 1 1/2 Gap: 1/8 minimum 2 3/4 maximum Three 16d (31/2 ) box nails 2x4 web stiffener (2) Tight

www.connectors.com e-mail: info@connectors.com Support Height & Lateral Stability Hangers for joists without web stiffeners must support the TJI s top flange and provide lateral resistance with no more than 1 8 horizontal deflection. Resist lateral movement 1/8 maximum gap EWP Installation Hangers for joists with web stiffeners must support a minimum of 60% of joist depth. Web stiffener 60% Min. depth (Top flange support requirements can be verified in EWP Top Mount Hangers charts under the Web Stiffener Req. column of s Full Line Catalog.) Nailer Installations Correct Hanger Attachment to Nailer A nailer or sill plate is considered to be any wood member attached to a steel beam, concrete block wall, concrete stem wall, or other structure unsuitable for nailing, which is used as a nailing surface for top mount hangers to hold beams or joists. Nailer Sized Correctly Top flange of hanger is fully supported and recommended nails have full penetration into nailer, resulting in a carried member hanging safely at the proper height. The nailer must be sized to fit the support width as shown and be of sufficient thickness to satisfy recommended top flange nailing requirements. A design professional must specify nailer attachment to steel beams. Wrong Nailer Size Causes Component Failure 1 4 Max. Avoid direct contact between hangers and steel beams, which may cause squeaks. 1 4 Max. Too Narrow Top flange not fully supported can cause nail breakout. Or, by fully supporting top flange, hanger is tilted back, causing lifting of carried member which results in uneven surfaces and squeaky floors. Too Wide Loading can cause cross grain breaking of nailer. The recommended nailer overhang is 1 4 maximum per side. Too Thin Top flange nailing cannot fully penetrate nailer, causing reduced allowable loads. Never use hangers which require multiple face nails since the allowable loads are dependent on all nail holes being used. Top Flange Hangers The thickness of the hanger metal and nail heads on top mount hangers must be evaluated for the effect on subsequent. Ensure the top mount hanger is installed so the flanges of the hanger are not over-spread which tends to elevate the supported TJI, causing uneven floor surfaces and squeaking. Similarly, ensure the hanger is installed plumb such that the face flanges of the hanger are mounted firmly against the wide-face surface of the header. Flush framing Hanger over-spread Hanger not plumb 945-041 3

Customer Service / Technical Assistance Livermore, CA Office Montgomery, MN Corporate Office Largo, FL Office 1-800-227-0470 1-800-328-5934 1-800-443-6442 Single TJI s THO Height TJI 110 Top Mount Hangers 4 Face Mount Hangers Fastener Schedule 5 Uplift 3 Down Fastener Schedule 5 Uplift 3 Header 133% 160% 100% 2 Stock No. 1,6 Header 133% 160% Width = 1-3/4 9-1/2 THO17950 (6) 10d (2) 10d x 1-1/2 245 245 935 THF17925 (8) 10d (2) 10d x 1-1/2 245 280 895 11-7/8 THO17118 (6) 10d (2) 10d x 1-1/2 245 245 950 THF17112 (8) 10d (2) 10d x 1-1/2 245 280 895 THO170 (10) 10d (2) 10d x 1-1/2 230 230 1215 THF170 (12) 10d (2) 10d x 1-1/2 245 280 950 TJI 210 Width = 2-1/16 9-1/2 THO20950 (6) 10d (2) 10d x 1-1/2 230 230 1030 THF20925 (8) 10d (2) 10d x 1-1/2 245 280 895 11-7/8 THO20118 (6) 10d (2) 10d x 1-1/2 230 230 1030 THF20112 (8) 10d (2) 10d x 1-1/2 245 280 895 THO200 (10) 10d (2) 10d x 1-1/2 230 230 1080 THF200 (12) 10d (2) 10d x 1-1/2 245 280 1045 16 THO20160 (10) 10d (2) 10d x 1-1/2 230 230 1080 THF20157 (24) 10d (2) 10d x 1-1/2 245 280 1045 TJI 230 Width = 2-5/16 9-1/2 THO23950 (10) 10d (2) 10d x 1-1/2 245 295 10 THF23925 (12) 10d (2) 10d x 1-1/2 175 175 1160 11-7/8 THO23118 (10) 10d (2) 10d x 1-1/2 245 295 1185 THF23118 () 10d (2) 10d x 1-1/2 175 175 1215 THO230 (12) 10d (2) 10d x 1-1/2 245 265 1185 THF230 (18) 10d (2) 10d x 1-1/2 175 175 1215 16 THO23160 (12) 10d (2) 10d x 1-1/2 245 265 1185 THF23160 (22) 10d (2) 10d x 1-1/2 245 295 1215 TJI 360 Width = 2-5/16 11-7/8 THO23118 (10) 10d (2) 10d x 1-1/2 245 295 1230 THF23118 () 10d (2) 10d x 1-1/2 175 175 1260 THO230 (12) 10d (2) 10d x 1-1/2 245 265 1230 THF230 (18) 10d (2) 10d x 1-1/2 175 175 1260 16 THO23160 (12) 10d (2) 10d x 1-1/2 245 265 1230 THF23160 (22) 10d (2) 10d x 1-1/2 245 295 1260 TJI 560 Stock No. 1,6 Width = 3-1/2 11-7/8 THO35118 (10) 10d (2) 10d x 1-1/2 245 295 30 THF35112 (16) 10d (2) 10d x 1-1/2 245 245 60 THO350 (12) 10d (2) 10d x 1-1/2 245 265 30 THF350 (20) 10d (2) 10d x 1-1/2 245 245 60 16 THO35160 (12) 10d (2) 10d x 1-1/2 245 265 30 THF35157 (22) 10d (2) 10d x 1-1/2 245 245 60 1) Web stiffeners may be required for hangers by Trus. 2) Loads listed are based on hanger attachment to a DF-L or SP species solid sawn, TJI or Microllam LVL, Parallam PSL, or TimberStrand LSL header. Contact your local Trus or Structural Connectors Technical Representative for additional duration of load values. 3) Uplift loads have been increased 33% or 60% for wind and seismic loading; no further increase shall be permitted. 4) Top Mount Hangers require minimum 3 header width for THO series hangers; 3-1/2 minimum header thickness for all other stock numbers. 5) 10d x 1-1/2 nails are 9 gauge (0.8 diameter) by 1-1/2 long. 10d and 16d nails are common wire and require a minimum penetration of 1-3/4 and 1-15/16 respectively. 16d sinkers (0.8 diameter) by 3-1/4 long may be substituted for 10d common nails with no load reduction. 6) For additional sizes, stock numbers, and modifications not shown, refer to 's Full Line Catalog. Down 100% 2 THF 4 MSH

www.connectors.com e-mail: info@connectors.com SINGLE TJI JOISTS Single TJI s Height TJI 110 Fastener Schedule 4 Uplift 3 Down Fastener Schedule 4,7 Uplift 3 Down Fastener Schedule 4,7 Uplift 3 Down Stock No. 1,6 Header 133% 160% 100% 2 Stock No. 1,6 Header 133% 160% 100% 2 Stock No. 1,6 Header 133% 160% 100% 2 Width = 1-3/4 9-1/2 -- -- -- -- -- -- -- -- -- -- -- -- LSSH179 (10) 10d (7) 10d x 1-1/2 475 570 1120 SKH1720L/R () 10d (10) 10d x 1-1/2 475 570 910 11-7/8 MSH1718 (6) 10d (4) 10d x 1-1/2 -- -- -- -- 885 LSSH179 (10) 10d (7) 10d x 1-1/2 475 570 1120 SKH1720L/R () 10d (10) 10d x 1-1/2 475 570 920 MSH1722 (6) 10d (4) 10d x 1-1/2 -- -- -- -- 885 LSSH179 (10) 10d (7) 10d x 1-1/2 475 570 1120 SKH1720L/R () 10d (10) 10d x 1-1/2 475 570 920 TJI 210 9-1/2 LSSH20 (10) 10d (7) 10d x 1-1/2 475 570 1120 SKH2020L/R () 10d (10) 10d x 1-1/2 475 570 1005 11-7/8 See current Full Line Catalog or Trus software LSSH20 (10) 10d (7) 10d x 1-1/2 475 570 1120 SKH2020L/R () 10d (10) 10d x 1-1/2 475 570 1015 for specialty hanger options LSSH20 (10) 10d (7) 10d x 1-1/2 475 570 1120 SKH2020L/R () 10d (10) 10d x 1-1/2 475 570 1015 16 LSSH20 8 (10) 10d (7) 10d x 1-1/2 475 570 1120 SKH2024L/R (16) 10d (10) 10d x 1-1/2 475 570 1015 TJI 230 9-1/2 -- -- -- -- -- -- -- -- -- -- -- -- LSSH23 (10) 10d (7) 10d x 1-1/2 475 570 1120 SKH2320L/R () 10d (10) 10d x 1-1/2 475 570 1055 11-7/8 MSH2318 (6) 10d (4) 10d x 1-1/2 -- -- -- -- 1035 LSSH23 (10) 10d (7) 10d x 1-1/2 475 570 1120 SKH2320L/R () 10d (10) 10d x 1-1/2 475 570 1065 MSH2318 (6) 10d (4) 10d x 1-1/2 -- -- -- -- 1035 LSSH23 (10) 10d (7) 10d x 1-1/2 475 570 1120 SKH2324L/R (16) 10d (10) 10d x 1-1/2 475 570 1065 16 MSH2322 (6) 10d (4) 10d x 1-1/2 -- -- -- -- 1035 LSSH23 8 (10) 10d (7) 10d x 1-1/2 475 570 1120 SKH2324L/R (16) 10d (10) 10d x 1-1/2 475 570 1065 TJI 360 11-7/8 MSH2318 (6) 10d (4) 10d x 1-1/2 -- -- -- -- 1080 LSSH23 (10) 10d (7) 10d x 1-1/2 475 570 1120 SKH2320L/R () 10d (10) 10d x 1-1/2 475 570 1110 MSH2318 (6) 10d (4) 10d x 1-1/2 -- -- -- -- 1080 LSSH23 (10) 10d (7) 10d x 1-1/2 475 570 1120 SKH2324L/R (16) 10d (10) 10d x 1-1/2 475 570 1110 16 MSH2322 (6) 10d (4) 10d x 1-1/2 -- -- -- -- 1080 LSSH23 8 (10) 10d (7) 10d x 1-1/2 475 570 1120 SKH2324L/R (16) 10d (10) 10d x 1-1/2 475 570 1110 TJI 560 Adjustable Height Field Slope & Skew Width = 2-1/16 Width = 2-5/16 Width = 2-5/16 Width = 3-1/2 11-7/8 MSH422 (6) 10d (6) 10d -- -- -- -- 1265 LSSH35 () 16d (12) 10d x 1-1/2 475 570 1595 SKH410L/R 5 (16) 16d (10) 10d 475 570 60 See current Full Line Catalog or Trus software LSSH35 () 16d (12) 10d x 1-1/2 475 570 1595 SKH4L/R 5 (22) 16d (10) 10d 475 570 60 16 for specialty hanger options LSSH35 8 () 16d (12) 10d x 1-1/2 475 570 1595 SKH4L/R 5 (22) 16d (10) 10d 475 570 60 1) Shaded hangers require web stiffeners at joist ends. Web stiffeners may be required for non-shaded hangers by Trus. 2) Loads listed are based on hanger attachment to a DF-L or SP species solid sawn, Microllam LVL, Parallam PSL, or TimberStrand LSL header. Contact your local Trus or Structural Connectors Technical Representative for additional duration of load values. 3) Uplift loads have been increased 33% or 60% for wind and seismic loading; no further increase shall be permitted. 4) 10d x 1-1/2 nails are 9 gauge (0.8 diameter) by 1-1/2 long. 10d nails are common wire and require a minimum penetration of 1-3/4 and 1-15/16 respectively. 5) Miter cut required on end of joist to achieve design loads. 6) For additional sizes, stock numbers, and modifications not shown, refer to 's Full Line Catalog. 7) Hangers utilizing 16d nails are not compatible with TJI joist headers. 8) LSTA24 strap required along top chord for lateral restraint. Skewed 45 Hangers LSSH 2 3 & 4 1 skew to 45 maximum LSSH Installation: Use all specified fasteners. Steps: 1. Position LSSH connector against plumb-cut end of joist. Fasten joist side flanges on both sides with 10d x 1-1/2 nails. Bend seat up to fit against joist bottom and drive (1) 10d x 1-1/2 nail through bottom seat into rafter bottom. Drive (2) 10d x 1-1/2 nails at downward angle through dimpled nailing guides. 2. Lean connector and rafter end against ridge beam at desired position. Install 10d or 16d nails through nail holes into ridge beam at right 90 angle. If skewing the rafter, only drive nails into ridge beam on inside flange. 3. Bend flange to desired angle. 4. Hammer outside flange until edge touches header. Fasten outside flange to ridge by driving 10d or 16d nails through nail holes. Web stiffeners are required for all wood I- installations. Designer may consider adding a tension restraint for the supported member for roof slopes exceeding 6/12. SKH_R (right shown) 945-041 5

Customer Service / Technical Assistance Livermore, CA Office Montgomery, MN Corporate Office Largo, FL Office 1-800-227-0470 1-800-328-5934 1-800-443-6442 Double TJI s Height Face Mount Hangers Fastener Schedule 5,9 Uplift 3 Down Fastener Schedule 5,9 Uplift 3 Down Fastener Schedule 5,9 Uplift 3 Stock No. 1,6 Header 133% 160% 100% 2 Stock No. 1,6 Header 133% 160% 100% 2 Stock No. 1,6 Header 133% 160% Double TJI 110 9-1/2 THO35950 (10) 10d (2) 10d x 1-1/2 245 295 2010 THF17925-2 (12) 10d (6) 10d 475 570 1350 SKH410L/R 7 (16) 16d (10) 16d 475 570 2060 11-7/8 THO35118 (10) 10d (2) 10d x 1-1/2 245 295 2050 THF17112-2 () 10d (6) 10d 475 570 1575 SKH410L/R 7 (16) 16d (10) 16d 475 570 2170 THO350 (12) 10d (2) 10d x 1-1/2 245 265 2100 THF170-2 (20) 10d (6) 10d 475 570 2170 SKH410L/R 7 (16) 16d (10) 16d 475 570 2170 Double TJI 210 9-1/2 THO20950-2 (10) 16d (6) 10d 475 570 2330 THF20925-2 (12) 10d (6) 10d 475 570 1350 SKH2020L/R-2 () 10d (10) 10d 475 570 1610 11-7/8 THO20118-2 (10) 16d (6) 10d 475 570 2610 THF20112-2 (16) 10d (6) 10d 475 570 1575 SKH2020L/R-2 () 10d (10) 10d 475 570 1610 THO200-2 (12) 16d (6) 10d 475 570 2330 THF200-2 (20) 10d (6) 10d 475 570 2250 SKH2024L/R-2 (16) 10d (10) 10d 475 570 1840 16 THO20160-2 (12) 16d (6) 10d 475 570 2330 -- -- -- -- -- -- -- -- -- -- -- -- SKH2024L/R-2 (16) 10d (10) 10d 475 570 1840 Double TJI 230 9-1/2 THO23950-2 (10) 16d (6) 10d 475 570 2490 THF23925-2 () 10d (6) 10d 475 570 1575 SKH2320L/R-2 () 10d (10) 10d 475 570 1610 11-7/8 THO23118-2 (10) 16d (6) 10d 475 570 2675 THF23118-2 (16) 10d (6) 10d 475 570 1800 SKH2320L/R-2 () 10d (10) 10d 475 570 1610 THO230-2 (12) 16d (6) 10d 475 570 2675 THF230-2 (20) 10d (6) 10d 475 570 2370 SKH2324L/R-2 (16) 10d (10) 10d 475 570 1840 16 THO23160-2 (12) 16d (6) 10d 475 570 2675 THF23160-2 (24) 10d (6) 10d 475 570 2430 SKH2324L/R-2 (16) 10d (10) 10d 475 570 1840 Double TJI 360 11-7/8 THO23118-2 (10) 16d (6) 10d 475 570 2765 THF23118-2 (16) 10d (6) 10d 475 570 1800 SKH2320L/R-2 () 10d (10) 10d 475 570 1610 THO230-2 (12) 16d (6) 10d 475 570 2765 THF230-2 (20) 10d (6) 10d 475 570 2370 SKH2324L/R-2 (16) 10d (10) 10d 475 570 1840 16 THO23160-2 (12) 16d (6) 10d 475 570 2765 THF23160-2 (24) 10d (6) 10d 475 570 2520 SKH2324L/R-2 (16) 10d (10) 10d 475 570 1840 Double TJI 560 Top Mount Hangers 4 Width = 3-1/2 Width = 4-1/8 Width = 4-5/8 Width = 4-5/8 Width = 7 11-7/8 BPH71118 (10) 16d (6) 10d 475 570 3185 HD7120 (16) 16d (6) 10d 475 570 2175 HD7120-SK45L/R 7,8 (16) 16d (6) 10d 475 570 2175 BPH71 (10) 16d (6) 10d 475 570 3185 HD70 (20) 16d (8) 10d 475 570 2720 HD70-SK45L/R 7,8 (20) 16d (8) 10d 475 570 2720 16 BPH7116 (10) 16d (6) 10d 475 570 3185 HD7160 (24) 16d (8) 10d 475 570 2925 HD7160-SK45L/R 7,8 (24) 16d (8) 10d 475 570 3265 1) Shaded hangers require web stiffeners at joist ends. Web stiffeners may be required for non-shaded hangers by Trus. 2) Loads listed are based on hanger attachment to a DF-L or SP species solid sawn, Microllam LVL, Parallam PSL, or TimberStrand LSL header. Contact your local Trus or Structural Connectors Technical Representative for additional duration of load values. 3) Uplift loads have been increased 33% or 60% for wind and seismic loading; no further increase shall be permitted. 4) Top Mount Hangers require minimum 3" header width for THO series hangers; 3-1/2" minimum header thickness for all other stock numbers. 5) 10d x 1-1/2 nails are 9 gauge (0.8 diameter) by 1-1/2 long. 10d and 16d nails are common wire and require a minimum penetration of 1-3/4 and 1-15/16 respectively. 16d sinkers (0.8 diameter) by 3-1/4 long may be substituted for 10d common nails with no load reduction. 6) For additional sizes, stock numbers, and modifications not shown, refer to 's Full Line Catalog. 7) Miter cut required on end of joist to achieve design loads. 8) Hangers are special order. Consult to for pricing and lead times. 9) Hangers utilizing 16d nails are not compatible with TJI joist headers. Skewed 45 Hangers Down 100% 2 THO-Double HD-Double BPH SKH_R-Double (right shown) THF-Double 6

www.connectors.com e-mail: info@connectors.com DOUBLE TJI JOISTS Double TJI s Height Double TJI 110 Fastener Schedule 4,7 Uplift 3 Down Fastener Schedule 4,7 Uplift 3 Down Header 133% 160% 100% 2 Stock No. 1,5 Header 133% 160% 100% 2 9-1/2 MSH422 (6) 10d (6) 10d -- -- -- -- 2025 LSSH35 () 16d (12) 10d x 1-1/2 475 570 1885 11-7/8 MSH422 (6) 10d (6) 10d -- -- -- -- 2025 LSSH35 () 16d (12) 10d x 1-1/2 475 570 1885 -- -- -- -- -- -- -- -- -- -- -- -- LSSH35 () 16d (12) 10d x 1-1/2 475 570 1885 Double TJI 210 9-1/2 11-7/8 16 Stock No. 1,5 Double TJI 230 9-1/2 MSH2322-2 6 (6) 10d (4) 10d -- -- -- -- 2210 11-7/8 MSH2322-2 6 (6) 10d (4) 10d -- -- -- -- 2210 MSH2322-2 6 (6) 10d (4) 10d -- -- -- -- 2210 16 -- -- -- -- -- -- -- -- -- -- -- -- Double TJI 360 11-7/8 MSH2322-2 6 (6) 10d (4) 10d -- -- -- -- 2160 MSH2322-2 6 (6) 10d (4) 10d -- -- -- -- 2160 16 -- -- -- -- -- -- -- -- -- -- -- -- Double TJI 560 Adjustable Height See current Full Line Catalog or Trus software for specialty hanger options Width = 3-1/2 Width = 4-1/8 Width = 4-5/8 Width = 4-5/8 Width = 7 11-7/8 MSH422-2 (8) 16d (6) 16d -- -- -- -- 2530 16 See current Full Line Catalog or Trus software for specialty hanger options Slope & Skew See current Full Line Catalog or Trus software for specialty hanger options See current Full Line Catalog or Trus software for specialty hanger options See current Full Line Catalog or Trus software for specialty hanger options See current Full Line Catalog or Trus software for specialty hanger options 1) Shaded hangers require web stiffeners at joist ends. Web stiffeners may be required for non-shaded hangers by Trus. 2) Loads listed are based on hanger attachment to a DF-L or SP species solid sawn, Microllam LVL, Parallam PSL, or TimberStrand LSL header. Contact your local Trus or Structural Connectors Technical Representative for additional duration of load values. 3) Uplift loads have been increased 33% or 60% for wind and seismic loading; no further increase shall be permitted. 4) 10d x 1-1/2 nails are 9 gauge (0.8 " diameter) by 1-1/2 long. 10d and 16d nails are common wire and require a minimum penetration of 1-3/4 and 1-15/16 respectively. 16d sinkers (0.8 diameter) by 3-1/4 long may be substituted for 10d common nails with no load reduction. 5) For additional sizes, stock numbers, and modifications not shown, refer to 's Full Line Catalog. 6) Hangers are special order. Consult for pricing and lead times. 7) Hangers utilizing 16d nails are not compatible with TJI joist headers. 8) LSTA24 strap required along top chord for lateral restraint. LSSH 2 3 & 4 1 skew to 45 maximum LSSH Installation: Use all specified fasteners. Steps: 1. Position LSSH connector against plumb-cut end of joist. Fasten joist side flanges on both sides with 10d x 1-1/2 nails. Bend seat up to fit against joist bottom and drive (1) 10d x 1-1/2 nail through bottom seat into rafter bottom. Drive (2) 10d x 1-1/2 nails at downward angle through dimpled nailing guides. 2. Lean connector and rafter end against ridge beam at desired position. Install 10d or 16d nails through nail holes into ridge beam at right 90 angle. If skewing the rafter, only drive nails into ridge beam on inside flange. 3. Bend flange to desired angle. 4. Hammer outside flange until edge touches header. Fasten outside flange to ridge by driving 10d or 16d nails through nail holes. Web stiffeners are required for all wood I- installations. Designer may consider adding a tension restraint for the supported member for roof slopes exceeding 6/12. MSH 945-041 7

Customer Service / Technical Assistance Livermore, CA Office Montgomery, MN Corporate Office Largo, FL Office 1-800-227-0470 1-800-328-5934 1-800-443-6442 Microllam LVL, Parallam PSL or Timberstrand LSL Beams & Headers THO HD HUS Height Down 100% 1 Header Material Header Material Header 133% 160% LVL PSL LSL Stock No. 6 Header 133% 160% DF-L/SP 1-3/4 Microllam LVL or Parallam PSL or TimberStrand LSL 7-1/4 PHXU17725 (8) 16d (6) 10d x 1-1/2 800 960 4155 4155 4155 -- -- -- -- -- -- -- -- -- -- -- -- 9-1/4 9-1/2 11-1/4 11-7/8 THO17925 (6) 10d (2) 10d x 1-1/2 230 230 1345 1290 1335 HD17925 (18) 16d (6) 10d x 1-1/2 770 920 2450 PHXU17925 (8) 16d (6) 10d x 1-1/2 800 960 4155 4155 4155 HUS179 5 (30) 16d (10) 16d 3205 3205 4890 THO17950 (6) 10d (2) 10d x 1-1/2 245 245 1345 1290 1335 HD17925 (18) 16d (6) 10d x 1-1/2 770 920 2450 PHXU1795 (8) 16d (6) 10d x 1-1/2 800 960 4155 4155 4155 HUS179 5 (30) 16d (10) 16d 3205 3205 4890 THO17112 (6) 10d (2) 10d x 1-1/2 230 230 1345 1290 1335 HD17112 (22) 16d (6) 10d x 1-1/2 770 920 2765 PHXU17112 (8) 16d (6) 10d x 1-1/2 800 960 4155 4155 4155 HUS179 5 (30) 16d (10) 16d 3205 3205 4890 THO17118 (6) 10d (2) 10d x 1-1/2 245 245 1345 1290 1335 HD17112 (22) 16d (6) 10d x 1-1/2 770 920 2765 PHXU17118 (8) 16d (6) 10d x 1-1/2 800 960 4155 4155 4155 HUS179 5 (30) 16d (10) 16d 3205 3205 4890 THO170 (10) 10d (2) 10d x 1-1/2 230 230 1760 1760 1760 HD17 (26) 16d (8) 10d x 1-1/2 1025 1065 2955 PHXU17 (8) 16d (6) 10d x 1-1/2 800 960 4155 4155 4155 HUS179 5 (30) 16d (10) 16d 3205 3205 4890 2-11/16 Parallam PSL 9-1/4 9-1/2 11-1/4 11-7/8 16 PHXU27925 (8) 16d (6) 10d x 1-1/2 800 960 6020 5785 6020 HD27925 (18) 16d (6) 10d x 1-1/2 770 920 2450 HLBH27925 (15) NA16D-RS (6) 10d x 1-1/2 935 1125 10225 10225 9600 THDH27925 5 (46) 16d (12) 16d 3490 3490 7910 PHXU2795 (8) 16d (6) 10d x 1-1/2 800 960 6020 5785 6020 HD27925 (18) 16d (6) 10d x 1-1/2 770 920 2450 HLBH2795 (15) NA16D-RS (6) 10d x 1-1/2 935 1125 10225 10225 9600 THDH27925 5 (46) 16d (12) 16d 3490 3490 7910 PHXU27112 (8) 16d (6) 10d x 1-1/2 800 960 6020 5785 6020 HD27112 (22) 16d (6) 10d x 1-1/2 770 920 2990 HLBH27112 (15) NA16D-RS (6) 10d x 1-1/2 935 1125 10225 10225 9600 THDH2710 5 (56) 16d () 16d 4830 5795 8705 PHXU27118 (8) 16d (6) 10d x 1-1/2 800 960 6020 5785 6020 HD27112 (22) 16d (6) 10d x 1-1/2 770 920 2990 HLBH27118 (15) NA16D-RS (6) 10d x 1-1/2 935 1125 10225 10225 9600 THDH2710 5 (56) 16d () 16d 4830 5795 8705 PHXU27 (8) 16d (6) 10d x 1-1/2 800 960 6020 5785 6020 HD27 (26) 16d (8) 10d x 1-1/2 1025 1065 3535 HBLH27 (15) NA16D-RS (6) 10d x 1-1/2 935 1125 10225 10225 9600 THDH27 5 (66) 16d (16) 16d 5520 6625 8985 PHXU2716 (8) 16d (6) 10d x 1-1/2 800 960 6020 5785 6020 HD27 (26) 16d (8) 10d x 1-1/2 1025 1065 3535 HLBH2716 (15) NA16D-RS (6) 10d x 1-1/2 935 1125 10225 10225 9600 THDH27 5 (66) 16d (16) 16d 5520 6625 8985 2 Ply 1-3/4 or 3-1/2 Microllam LVL or Parallam PSL or TimberStrand LSL 7-1/4 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- THD48 (28) 16d (16) 10d 2390 2485 3750 9-1/4 9-1/2 11-1/4 11-7/8 16 18 Stock No. 6 Top Mount Hangers 3 Fastener Schedule 4 Uplift 2 Down 100% 1 Face Mount Hangers Fastener Schedule 4 PHXU35925 (8) 16d (6) 10d 1020 1220 6420 5785 6420 THD410 (38) 16d (20) 10d 2985 3585 5090 HLBH35925 (15) NA16D-RS (6) 16d 1280 20 10620 10565 9600 THDH410 5 (46) 16d (12) 16d 3970 3970 7910 PHXU3595 (8) 16d (6) 10d 1020 1220 6420 5785 6420 THD410 (38) 16d (20) 10d 2985 3585 5090 HLBH3595 (15) NA16D-RS (6) 16d 1280 20 10620 10565 9600 THDH410 5 (46) 16d (12) 16d 3970 3970 7910 PHXU35112 (8) 16d (6) 10d 1020 1220 6420 5785 6420 THD410 (38) 16d (20) 10d 2985 3585 5090 HLBH35112 (15) NA16D-RS (6) 16d 1280 20 10620 10565 9600 THDH412 5 (56) 16d () 16d 4830 5225 9560 PHXU35118 (8) 16d (6) 10d 1020 1220 6420 5785 6420 THD410 (38) 16d (20) 10d 2985 3585 5090 HLBH35118 (15) NA16D-RS (6) 16d 1280 20 10620 10565 9600 THDH412 5 (56) 16d () 16d 4830 5225 9560 PHXU35 (8) 16d (6) 10d 1020 1220 6420 5785 6420 THD410 (38) 16d (20) 10d 2985 3585 5090 HLBH35 (15) NA16D-RS (6) 16d 1280 20 10620 10565 9600 THDH4 5 (66) 16d (16) 16d 5520 6115 9845 PHXU3516 (8) 16d (6) 10d 1020 1220 6420 5785 6420 THD412 (48) 16d (20) 10d 2985 3585 6430 HLBH3516 (15) NA16D-RS (6) 16d 1280 20 10620 10565 9600 THDH4 5 (66) 16d (16) 16d 5520 6115 9845 PHXU3518 (8) 16d (6) 10d 1020 1220 6420 5785 6420 THD412 (48) 16d (20) 10d 2985 3585 6430 HLBH3518 (15) NA16D-RS (6) 16d 1280 20 10620 10565 9600 THDH4 5 (66) 16d (16) 16d 5520 6115 9845 1) Loads listed are based on hanger attachment to a DF-L or SP species solid sawn or Microllam LVL, Parallam PSL, or TimberStrand LSL header. Contact your local Trus or Structural Connectors Technical Representative for additional duration of load values. 2) Uplift loads have been increased 33% or 60% for wind and seismic loading; no further increase shall be permitted. 3) Top Mount Hangers require a minimum 3 header width for THO series hangers; 3-1/2 minimum header thickness for all other stock numbers. 4) 10d x 1-1/2 nails are 9 gauge (0.8 diameter) by 1-1/2 long. 10d and 16d nails are common wire and require a minimum penetration of 1-3/4 and 1-15/16 respectively. 16d sinkers (0.8 diameter) by 3-1/4 long may be substituted for 10d common nails with no load reduction. 5) nails need to be toe nailed at a 30 to 45 angle to achieve listed loads for THDH and HUS models. 6) For additional sizes, stock numbers, and modifications not shown, refer to 's Full Line Catalog. Uplift 2 8

www.connectors.com e-mail: info@connectors.com MICROLLAM LVL, PARALLAM PSL OR TIMBERSTRAND LSL BEAMS & HEADERS Microllam LVL, Parallam PSL or Timberstrand LSL Beams & Headers Height Down 100% 1 Header Material Header Material Header 133% 160% LVL PSL LSL Stock No. 6 Header 133% 160% DF-L/SP 3 Ply 1-3/4 or 5-1/4 Microllam LVL or Parallam PSL or TimberStrand LSL 7-1/4 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 9-1/4 9-1/2 11-1/4 11-7/8 16 18 PHXU55925 (8) 16d (6) 10d 1020 1220 6650 5785 6650 THD610 (38) 16d (20) 10d 3200 3410 5360 HLBH55925 (15) NA16D-RS (6) 16d 1280 1535 10620 10565 9600 THDH610 5 (46) 16d (12) 16d 4105 4930 7840 PHXU5595 (8) 16d (6) 10d 1020 1220 6650 5785 6650 THD610 (38) 16d (20) 10d 3200 3410 5360 HLBH5595 (15) NA16D-RS (6) 16d 1280 1535 10620 10565 9600 THDH610 5 (46) 16d (12) 16d 4105 4930 7840 PHXU55112 (8) 16d (6) 10d 1020 1220 6650 5785 6650 THD610 (38) 16d (20) 10d 3200 3410 5360 HLBH55112 (15) NA16D-RS (6) 16d 1280 1535 10620 10565 9600 THDH612 5 (56) 16d () 16d 4790 5750 9475 PHXU55118 (8) 16d (6) 10d 1020 1220 6650 5785 6650 THD610 (38) 16d (20) 10d 3200 3410 5360 HLBH55118 (15) NA16D-RS (6) 16d 1280 1535 10620 10565 9600 THDH612 5 (56) 16d () 16d 4790 5750 9475 PHXU55 (8) 16d (6) 10d 1020 1220 6650 5785 6650 THD610 (38) 16d (20) 10d 3200 3410 5360 HLBH55 (15) NA16D-RS (6) 16d 1280 1535 10620 10565 9600 THDH6 5 (66) 16d (16) 16d 5475 6570 11105 PHXU5516 (8) 16d (6) 10d 1020 1220 6650 5785 6650 THD612 (48) 16d (20) 10d 3200 3840 6770 HLBH5516 (15) NA16D-RS (6) 16d 1280 1535 10620 10565 9600 THDH6 5 (66) 16d (16) 16d 5475 6570 11105 PHXU5518 (8) 16d (6) 10d 1020 1220 6650 5785 6650 THD612 (48) 16d (20) 10d 3200 3840 6770 HLBH5518 (15) NA16D-RS (6) 16d 1280 1535 10620 10565 9600 THDH6 5 (66) 16d (16) 16d 5475 6570 11105 4 Ply 1-3/4 or 7 Microllam LVL or Parallam PSL or TimberStrand LSL 9-1/4 9-1/2 11-1/4 11-7/8 16 18 Stock No. 6 PHXU71925 (8) 16d (6) 10d 1020 1220 6650 5785 6650 THD7210 (38) 16d (18) 16d 3360 4030 5320 HLBH71925 (15) NA16D-RS (6) 16d 1280 1535 10620 10370 9600 THDH7210 5 (46) 16d (12) 16d 4105 4930 7840 PHXU7195 (8) 16d (6) 10d 1020 1220 6650 5785 6650 THD7210 (38) 16d (18) 16d 3360 4030 5320 HLBH7195 (15) NA16D-RS (6) 16d 1280 1535 10620 10370 9600 THDH7210 5 (46) 16d (12) 16d 4105 4930 7840 PHXU71112 (8) 16d (6) 10d 1020 1220 6650 5785 6650 THD7210 (38) 16d (18) 16d 3360 4030 5320 HLBH71112 (15) NA16D-RS (6) 16d 1280 1535 10620 10370 9600 THDH7212 5 (56) 16d () 16d 4790 5750 9475 PHXU71118 (8) 16d (6) 10d 1020 1220 6650 5785 6650 THD7210 (38) 16d (18) 16d 3360 4030 5320 HLBH71118 (15) NA16D-RS (6) 16d 1280 1535 10620 10370 9600 THDH7212 5 (56) 16d () 16d 4790 5750 9475 PHXU71 (8) 16d (6) 10d 1020 1220 6650 5785 6650 THD7210 (38) 16d (18) 16d 3360 4030 5320 HLBH71 (15) NA16D-RS (6) 16d 1280 1535 10620 10370 9600 THDH72 5 (66) 16d (16) 16d 5475 6570 11105 PHXU7116 (8) 16d (6) 10d 1020 1220 6650 5785 6650 HD7120 (16) 16d (6) 10d 910 1000 2175 HLBH7116 (15) NA16D-RS (6) 16d 1280 1535 10620 10370 9600 THDH72 5 (66) 16d (16) 16d 5475 6570 11105 PHXU7118 (8) 16d (6) 10d 1020 1220 6650 5785 6650 HD70 (20) 16d (8) 10d 1215 60 2720 HLBH7118 (15) NA16D-RS (6) 16d 1280 1535 10620 10370 9600 THDH72 5 (66) 16d (16) 16d 5475 6570 11105 See footnotes on page 8. Top Mount Hangers 3 Face Mount Hangers Fastener Schedule 4 Uplift 2 Down 100% 1 Fastener Schedule 4 Uplift 2 PHXU HLBH THD THDH 945-041 9

Customer Service / Technical Assistance Livermore, CA Office Montgomery, MN Corporate Office Largo, FL Office 1-800-227-0470 1-800-328-5934 1-800-443-6442 Variable Pitch Connectors TMP & TMPH series The TMP and TMPH is designed to make rafter-to-plate connections and eliminates time-consuming bird s-mouth notching or bevel plate installation. The TMP automatically adjusts to pitches from 1/12 to 6/12 and the TMPH from 6/12 to /12. Pitch Range: TMP 1 12 6 12 TMPH 6 12 12 Installation: Use all specified fasteners. Position connector on top plate. Fasten connector to outside of top plate with specified nails. Insert rafter into rafter pocket. Adjust rafter and pocket to correct pitch. Fasten rafter to connector with specified nails. Installing the TMP requires driving specified nails through the opposing slots in the pocket. TMPH installation involves sliding the fulcrum until it supports the pocket at the desired pitch and nailing down through the fulcrum base into the top plate to lock the fulcrum into position. fulcrum Typical TMP installation TMP TMPH Typical TMPH installation Stock No. 1,5 Fastener Schedule 4 DF-L/SP Down 2 Uplift 3 Header 100% 133% 160% TJI 110 Width = 1-3/4 TMP175 (6) 10d (4) 10d x 1-1/2 1150 220 220 TMPH175 (10) 10d (8) 10d x 1-1/2 1945 200 200 TJI 210 Width = 2-1/16 -- -- -- -- -- -- -- -- -- -- -- -- TJI 230 Width = 2-5/16 TMP23 (6) 10d (4) 10d x 1-1/2 1785 220 220 TMPH23 (10) 10d (8) 10d x 1-1/2 1945 200 200 TJI 360 Width = 2-5/16 TMP23 (6) 10d (4) 10d x 1-1/2 1785 220 220 TMPH23 (10) 10d (8) 10d x 1-1/2 1945 200 200 TJI 560 Width = 3-1/2 TMP4 (6) 10d (4) 10d x 1-1/2 1970 220 220 TMPH4 (10) 10d (8) 10d x 1-1/2 1945 200 200 1) Shaded hangers require web stiffeners at joist ends. Web stiffeners may be required for non-shaded hangers by Trus. 2) Loads listed are based on hanger attachment to a DF-L or SP species solid sawn or LVL header. Loads are governed by test results; no further increase shall be permitted. 3) Uplift loads have been increased 33% or 60% for wind and seismic loading; no further increase shall be permitted. 4) 10d x 1-1/2 nails are 9 gauge (0.8 " diameter) by 1-1/2 long. 10d nails are common wire and require a minimum penetration of 1-3/4 respectively. 5) For additional sizes, stock numbers, and modifications not shown, refer to 's Full Line Catalog. 10

www.connectors.com e-mail: info@connectors.com General Installation WS Series Wood Screw Applications - Joining 2, 3, or 4 Ply LVL or PSL Members name SH Serrations 3 Installation: /8 Screw length Screws are self-drilling. Install using a low speed clutch drill with 3/8 hex head driver. The washer head should be flat to the surface and the serrations will oppose turning and release the clutch. Do not over-tighten the screws. For 2 ply members, wood screws shall be installed with the screw heads in the loaded ply. For 3 or 4 ply members, wood screws shall be installed in both outer plies. Designer shall specify all wood screws locations. Increase edge and end distances if wood splitting occurs. Stagger all screws installed into the opposite face. Recommended Row Guidelines - A minimum of 2 rows of screws shall be used for all members 5 1 /2 and larger 1 1/2 min. 1 min. Recommended (Typ) L T WS Beveled reamer on 2-1/2 or longer Wood Screws Cut threads Self-drilling point Other stagger patterns as approved by Engineer are acceptable 2 1/2 min. 2 1/2 min. End of member 1 1/2 min. Spacing 4 min. 24 max. Spacing 4 min. 24 max. 4 min. Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 (2) 1-3/4 WS35 (3) 1-3/4 WS35 (4) 1-3/4 WS6 (1) 1-3/4, (1) 3-1/2 WS35 (2) 1-3/4, (1) 3-1/2 WS35 (2) 3-1/2 WS6 Stock No. WS35 Description L SH T 1/4 x 3-1/2 3-1/2 1 WS6 6 1/4 x 6 6 Dimensions 1-3/4 2-1/2 4-1/4 Multiple Members Installation Figure 1,2,3,7 2 Rows Maximum Allowable Uniform Loads that can be applied to either outside member (Lbs. Per Lineal Ft.) 4,5,8 3 Rows Douglas Fir-Larch (G = 0.50) Wood Screw Spacing 12 O.C. 18 O.C. 24 O.C. 2 Rows 1 995 95 665 995 500 745 2 745 1120 500 745 375 560 4 745 1120 500 745 375 560 5 665 995 440 665 330 500 3 665 995 440 665 330 500 6 995 95 665 995 500 745 1) Based on Zscrew = 249 pounds in Douglas Fir-Larch with a side member thickness of not less than 1-3/4. 2) Load values depicted assume all uniform load is applied to the most narrow outside ply only. 3) Load values neglect any contribution of screws installed to opposite side, even if they extend significantly into the loaded ply. 4) Loads are for normal (100%) duration of load, and may be increased in accordance with the code. 5) Uniform loads in table represent the capacity of the fasteners. The capacity of the Microllam LVL, Parallam PSL, or TimberStrand LSL beam may be less and should be checked by a qualified designer or with the manufacturer's literature. 6) Wood screws longer than 3-1/2 are not recommended for use with TimberStrand LSL. 7) For Figures 2, 3, 5, and 6: Stagger the screws on opposite face by half minimum spacing requirements. 8) A qualified designer shall ensure the adequacy of a 7 wide beam to resist the applied load on one edge; otherwise, the loads shall be uniformly distributed across the width or applied equally on both sides. 3 Rows 2 Rows 3 Rows 945-041 11

Specification Tools All available on our Web Site @ www.connectors.com Building Stronger Safer Structures Catalogs CAD Library Comparison Guides Literature Request About Code Changes Allowable Stress Increases Contact Us Continuing Education Credits Guestbook Industry Links Literature Request Press Releases HHCP2 Technical Resources Hurricane/Seismic Anchor Web Site Watch Registration What s New PHDN16 Nail-On Predeflected Holdown GIBRALTAR CONSTRUCTION PRODUCTS Comprehensive Web Site Contains all literature in a printable.pdf format CAD Menu Program and Drawing Library downloads Quick and Easy literature ordering Register on-line at Web Site Watch Registration and automatically receive product updates through your e-mail Products are Supported by a National Factory Technical Sales Force HD2X Truss Holdown Strap Structural Connectors Copyright 1998-2003. All Rights Reserved. Web site online since November 6, 1998 e-mail: info@connectors.com CAD Menu Program Install a new Drop Down Menu in your AutoCAD menu bar (AutoCAD r, AutoCAD 2000, 2000i, 2002, 2004) Import scalable product drawings directly into your details or section drawings Available in 3-view format; top, front, and side where applicable JUS210-2 TOP VIEW JUS210-2 FRONT VIEW JUS210-2 SIDE VIEW CAD Library CAD Library contains over 350 illustrations in.dxf and.dwg formats Find drawings quickly by Stock No. or Reference No. High Wind Illustrations are also available Comparison Guides Compare code & load values side-by-side with our competitor Each Table shows Connector rated values Code Evaluation listings Indexed by Stock No. and Reference No. LUS NER-209, NER-421, NER-499, ICBO ES ER-5649, JUS NER-608 pg. 10 & 11, ICBO ES ER-5356 pg. 3, ICBO ES ER-5656, ICBO ES ER-5683 ICBO ES ER-2039 pg. 24 Design Load Design Load Simpson Floor Roof Uplift Floor Roof Uplift Stock No. 100% 115% 125% 133% 160% Stock No. 100% 115% 125% 133% 160% LUS24 640 735 800 465 490 JUS24 645 740 805 510 510 LUS26 830 955 1040 930 1115 JUS26 840 970 1050 1115 1115 LUS28 1055 1210 1320 930 1115 JUS28 1065 1225 1330 1115 1115 LUS210 1275 70 1595 930 1115 JUS210 1290 85 1610 1115 1115 LUS24-2 765 880 960 440 440 JUS24-2 770 885 965 325 325 LUS26-2 1000 1150 1250 10 1165 JUS26-2 1005 1160 1220 1340 1355 LUS28-2 1265 55 1585 10 1165 JUS28-2 1275 65 1595 1340 1355 LUS210-2 1765 2030 2210 1710 1745 JUS210-2 1780 2045 2225 1980 1980 LUS2-2 2030 2335 2540 1710 1745 JUS2-2 2315 2660 2895 1980 1980 Livermore, CA Office Montgomery, MN Corporate Office Largo, FL Office 2150 Kitty Hawk Road 703 Rogers Drive 11910 62nd Street North Livermore, CA 94551-9522 Montgomery, MN 56069-1324 Largo, FL 33773-3705 1-800-227-0470 Fax: 1-925-373-9213 1-800-328-5934 Fax: 1-507-364-8762 1-800-443-6442 Fax: 1-727-535-8199 www.connectors.com 945-041 Your Local Dealer / Distributor