Single Input ph/redox (ORP) Analyzer

Similar documents
Pasteurizer Recorder and Recorder Controller

Installation Guide Electrical Noise Protection. COMMANDER 1950 Series Circular Chart Recorders. All Versions !50.8 degf OP

User Guide IM/AX4DO Rev. H. AX418, AX438, AX480, AX468 and AX488 Single and dual input analyzers for dissolved oxygen

User Guide IM/AX4CO Rev. O. AX410, AX411, AX413, AX416, AX418, AX450, AX455 & AX456 Single and dual input analyzers for low level conductivity

MagMaster Electromagnetic Flowmeters. Instruction Manual

Analyze IT Single and Dual Input Analyzers for ph/redox (ORP)

Programming Guide IM/C1900-MPC Rev. E. C1900 Multi-recipe Profile Controller Versions Circular Chart Recorder / Controllers

ABB MEASUREMENT & ANALYTICS DATA SHEET. AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)

AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)

Analyze IT Single and Dual Input Analyzers for ph/redox (ORP)

Single and Dual Input Analyzers for Low-level Conductivity

Conductivity Analyzer

ABB MEASUREMENT & ANALYTICS DATA SHEET. AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers for low level conductivity

ControlMaster CM10, CM30, CM50 Universal process controllers, 1 /8, 1 /4 and 1 /2 DIN

PID Control Technical Notes

ABB ph/orp analyzer and probe package

Multi-electrode Conductivity Analyzers

ABB conductivity analyzer and probe package

Think About Control Fundamentals Training. Terminology Control. Eko Harsono Control Fundamental - Con't

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible

Specification DataFile

OVEN INDUSTRIES, INC. Model 5C7-362

Procidia Control Solutions Dead Time Compensation

Instruction Notes for 108A L Sensor Input

Position Transmitter TGS 40 (RAM)

Electronic Commercial Water Meter Powered by External Battery Pack AquaMaster Explorer

CONTENTS Page 1 INTRODUCTION SUPPLEMENTARY INSTRUCTIONS TO BOOK 3 ELECTRICAL INSTALLATION Section Page 1 INTRODUCTION The cable supplied with your Mag

The Company. ControlMaster CM30 and CM50 Universal process controllers, 1 /4 and 1 /2 DIN

User s Manual. Model US1000 Digital Indicating Controller Functions. IM 5D1A01-02E 2nd Edition IM 5D1A01-02E

QuickBuilder PID Reference

W100/W600/W900 Controller ph Electrode Troubleshooting Guide

Please enter the identity code of your device here!

Electromagnetic Flowmeter

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

REE series digital interpolators

APPENDIX APPENDIX A 1

Closed-Loop Position Control, Proportional Mode

8510 AC Spindle Drive System

R180. AVRs. Installation and maintenance

Electromagnetic Flowmeter Hygienic/Sanitary

Instrumentation and Control Technician A Guide to Course Content Implementation Beginning with Level 1 April 2013

New Technology for Monitoring Cycle Chemistry. David M. Gray McIlvaine Hot Topic Hour February 21, 2013

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application

Instruction manual SMART 96-2 / WG-2 ph

Fundamentals of Industrial Control

CoriolisMaster Measurement made easy Accurate flow measurement of liquids and gases

Draw the symbol and state the applications of : 1) Push button switch 2) 3) Solenoid valve 4) Limit switch ( 1m each) Ans: 1) Push Button

-binary sensors and actuators (such as an on/off controller) are generally more reliable and less expensive

Please enter the identity code of your device here!

6.9 Jump frequency - Avoiding frequency resonance

Introduction To Temperature Controllers

ph/orp Transmitter SIGNET

Instructions for Tempco Control Enclosure PCM10001 through PCM10004

Operating Guide. COMMANDER 300/310 Universal Process Controllers COMMANDER COMMANDER A1 A2 L R ST M. ABB Instrumentation

INSTRUCTIONS FOR INSTALLATION AND USE. LTR15

The MFT B-Series Flow Controller.

USER MANUAL. EPP Intelligent Positioner Control Unit 1/22.

Signet 9950 Dual Channel Transmitter

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

Enhanced PID for Air Compressors F7 Drive Software Technical Manual

Configuration Example of Temperature Control

6.4 Adjusting PID Manually

Job Sheet 2 Servo Control

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

1000TR. Instructions

ABB Instrumentation. Flowmeter. Specification DataFile

WATERFLUX 3000 Quick Start

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

WATERFLUX 3000 Quick Start

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

TI25 - Pre-Instructional Survey

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

The Discussion of this exercise covers the following points: On-off control On-off controller with a dead band. Conductivity control

Types of control systems:

Universal Controller

vacon 100 flow ac drives application manual

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

Closed-Loop Speed Control, Proportional-Plus-Integral-Plus-Derivative Mode

Controller Algorithms and Tuning

Signet 9950 Dual Channel Transmitter

Microprocessor Transmitter/Controller for ph - Type for redox - Type B Operating Instructions 9.

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Different Controller Terms

DIGITAL ph / ORP / mv CONTROLLER PMH-2 USERS GUIDE. PMH-2 Instruction manual PAGE 1

HC-220 PID Controller

Coriolis Mass Flow Meters. Advanced flow measurement made easy.

SERVOPRO MultiExact PROCESS ANALYSERS APPLICATIONS FEATURES

Troubleshooting Guide for Aquatrac Smart AS and Flex

LESSON 2: ELECTRONIC CONTROL

ControlMaster CM15 Universal process indicator 1 /8 DIN Custom configuration sheet

Experiment 9. PID Controller

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

InstrumentationTools.com

HART Mode. Users Guide. July Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies.

Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or

/2 DIN Advanced Process Controller

INSTRUCTION MANUAL Redox sensor M 1322 C

Temperature Controller

For reliable and continuous measurement of water quality insist on Aqua SMARTPro Transmitters

Signet ph/orp Transmitter * *

Transcription:

User Guide PID Control Supplement IM/AX4PID_5 Single Input ph/redox (ORP) Analyzer AX460

ABB The Company BS EN ISO 9001:2000 We are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental applications. As a part of ABB, a world leader in process automation technology, we offer customers application expertise, service and support worldwide. We are committed to teamwork, high quality manufacturing, advanced technology and unrivalled service and support. The quality, accuracy and performance of the Company s products result from over 100 years experience, combined with a continuous program of innovative design and development to incorporate the latest technology. The UKAS Calibration Laboratory No. 0255 is just one of the ten flow calibration plants operated by the Company, and is indicative of our dedication to quality and accuracy. Cert. No. Q05907 EN 29001 (ISO 9001) Lenno, Italy Cert. No. 9/90A Stonehouse, U.K. 0255 Electrical Safety This equipment complies with the requirements of CEI/IEC 61010-1:2001-2 'Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use'. If the eqipment is used in a manner NOT specified by the Company, the protection provided by the equipment may be impaired. Symbols One or more of the following symbols may appear on the equipment labelling: Warning Refer to the manual for instructions Direct current supply only Caution Risk of electric shock Alternating current supply only Protective earth (ground) terminal Earth (ground) terminal Both direct and alternating current supply The equipment is protected through double insulation Information in this manual is intended only to assist our customers in the efficient operation of our equipment. Use of this manual for any other purpose is specifically prohibited and its contents are not to be reproduced in full or part without prior approval of the Technical Publications Department. Health and Safety To ensure that our products are safe and without risk to health, the following points must be noted: 1. The relevant sections of these instructions must be read carefully before proceeding. 2. Warning labels on containers and packages must be observed. 3. Installation, operation, maintenance and servicing must only be carried out by suitably trained personnel and in accordance with the information given. 4. Normal safety precautions must be taken to avoid the possibility of an accident occurring when operating in conditions of high pressure and/ or temperature. 5. Chemicals must be stored away from heat, protected from temperature extremes and powders kept dry. Normal safe handling procedures must be used. 6. When disposing of chemicals ensure that no two chemicals are mixed. Safety advice concerning the use of the equipment described in this manual or any relevant hazard data sheets (where applicable) may be obtained from the Company address on the back cover, together with servicing and spares information.

CONTENTS 1 INTRODUCTION... 2 1.1 Single PID Controlle... 2 1.1.1 Reverse Acting (Base) Single PID Control...2 1.1.2 Direct Acting (Acid) Single PID Control... 3 1.2 Dual (Bi-directional) PI Controller... 3 1.3 Ouput Assignment... 4 2 OPERATION... 5 2.1 Introduction... 5 2.2 Operating Page... 7 2.2.1 Single PID Controller... 7 2.2.2 Dual (Bi-directional) PI Controller... 8 3 OPERATOR VIEWS... 10 3.1 View Set Points... 10 4 PROGRAMMING... 11 4.1 Setting Up Three Term (PID) Control Parameters 11 4.2 Manual Tuning... 11 4.3 Configure Control... 12 4.3.1 Configure Single PID Controller... 13 4.3.2 Configure Dual (Bi-directional) PI Controller... 16 4.4 Configure Power Failure Recovery Mode... 19 1

1 INTRODUCTION The AX460 Single Input ph Analyzer has been enhanced with the addition of Proportional Integral Derivative (PID) control. PID control can be either relay output (Time Proportioning or Pulse Frequency) or analog output. The control output can be configured as either a Single PID Controller (Reverse or Direct Acting) or as a Dual PI Controller (Bi-directional Acid/Base). The output from the Single PID Controller is assignable to either a relay or an analog output. The outputs from the Dual PI Controller are assignable to either relays, analog outputs or one of each type. This supplementary manual provides additional information relevant to the PID control features of the analyzer and must be read in conjunction with the User Guide (IM/AX4PH). 1.1 Single PID Controller Fig. 1.1 The single PID controller is a basic feedback control system using three-term PID control with a local set point. Manual Output Control Set Point PID Control Loop PID Output Output 1 Process Variable Fig. 1.1 Single PID Controller 1.1.1 Reverse Acting (Base) Single PID Control Fig. 1.2 Reverse acting control is used when the process ph is less than the required output ph. Normally, a base is added to the sample to increase the ph value. 100% Control Output Reverse Acting 0% 0pH 7pH 14pH Process Variable Fig. 1.2 Reverse Acting (Base) Single PID Control 2

1 INTRODUCTION 1.1.2 Direct Acting (Acid) Single PID Control Fig. 1.3 Direct acting control is used when the process ph is greater than the required output ph. Normally, acid is added to the sample to decrease the ph value. 100% Control Output Direct Acting 0% 0pH 7pH 14pH Process Variable Fig. 1.3 Direct Acting (Acid) Single PID Control 1.2 Dual (Bi-directional) PI Controller Figs 1.4 and 1.5 The dual (bi-directional) PI controller is a a dual-feedback control system using P + I control with two local set points. Manual Output High Set Point Process Variable PI Control Loop PI Output Output 1 Low Set Point Process Variable PI Control Loop PI Output Output 2 Fig. 1.4 Dual (Bi-directional) PI Controller 3

1 INTRODUCTION 1.2 Dual (Bi-directional) PI Controller Figs 1.4 and 1.5 Dual (bi-directional) control is used if the ph value must be controlled within specified upper and lower limits. The minimum span between set points is 0.5pH. 100% Control Output Reverse Acting Base Controller (Output 2) Direct Acting Acid Controller (Output 1) 0% 0pH 6pH 8pH 14pH Fig. 1.5 Dual (Bi-directional) PI Control 1.3 Ouput Assignment For single PID control, the output signal is assignable to either relay 1 or analog output 1. For dual (bi-directional) PI control, the output signals are assignable to any two of the following outputs: relay 1, relay 2, analog output 1 and analog output 2 see Table 1.1 and Section 4.3. Single PID Controller Output Type Relay 1 Relay 2 Relay 3 AO 1 AO 2 Analog Time or Pulse Dual (Bi-directional) PI Controller (Direct Acting Acid Controller) Time Time Analog or Pulse Analog or Pulse (Reverse Acting Base Controller) Relay 1 Relay 2 Relay 3 AO 1 AO 2 Analog Analog Time or Pulse Time or Pulse Table 1.1 Output Assignment 4

2 OPERATION 2.1 Introduction The location of the PID controller programming pages and menus within the analyzer's operating software is shown in the overall programming charts see Figs. 2.1 and 2.2. Use the Sidescroll Key to scroll through the Pages within each Menu Use the Menu Key to scroll through the Menus OPERATING PAGE SENSOR CAL. Security Code CONFIG. DISPLAY Refer to User Guide (IM/AX4PH) CONFIG. SENSORS CONFIG. ALARMS CONFIG. OUTPUTS Section 4.3, Page 12 CONFIG. CONTROL Controller PID Controller Power Recovery Control Action Power Rec. Mode Use the Downscroll Key to scroll through the Parameters within each Page Proportional Band Integral Time Derivative Time Default Output Pulses/Minute OR Cycle Time OR Output Range CONFIG. CLOCK OR CONFIG. SECURITY Analog option board fitted Analog option board not fitted Refer to User Guide (IM/AX4PH) Fig. 2.1 Overall Programming Chart Single PID Controller 5

2 OPERATION Use the Sidescroll Key to scroll through the Pages within each Menu Use the Menu Key to scroll through the Menus OPERATING PAGE SENSOR CAL. Security Code CONFIG. DISPLAY Refer to User Guide (IM/AX4PH) CONFIG. SENSORS CONFIG. ALARMS CONFIG. OUTPUTS Section 4.3, Page 12 CONFIG. CONTROL Controller Acid Controller Base Controller Power Recovery Proportional Band Proportional Band Power Rec. Mode Use the Downscroll Key to scroll through the Parameters within each Page Integral Time Pulses/Minute Integral Time Pulses/Minute Default Output OR OR Cycle Time Cycle Time OR OR Output Range Output Range CONFIG. CLOCK OR CONFIG. SECURITY Analog option board fitted Analog option board not fitted Refer to User Guide (IM/AX4PH) Fig. 2.2 Overall Programming Chart Dual (Bi-directional) PI Controller 6

2 OPERATION 2.2 Operating Page 2.2.1 Single PID Controller Note. The Single PID Controller operating page replaces the Single Input ph operating page shown in Section 2.3.1 of the User Guide, IM/AX4PH. 7.00 ph 24.6 Deg.C Setpoint 7.00pH Measured Values ph. Temperature. Control set point. 7.00 ph Control Mode 7.00 60.0 Manual ph % Man Setpoint 7.00pH 7.00 ph 7.00 ph Control Setpoint Control Mode Measured ph. Control mode. Use the and keys to switch between manual (Manual) and automatic (Auto) control. Control Output Measured ph. Control output (%), manual (Man) or automatic (Auto). When Control Mode is set to Manual (see above), use the and keys to adjust the control output between 0 and 100%. Control Set Point Measured ph. Control set point. Use the and keys to adjust the control set point between 0 and 14pH. Measured Millivolts 404 mv Millivolts Millivolts. 100.0 % 7.00 ph A: Slope & Check % Slope and ph Check Value % slope value. A value between the programmed minimum % slope value (see Set Min Slope in the CONFIG. SENSORS page User Guide Section 5.3) and 105% is displayed. If the value is outside these limits, check the electrode system. ph check value (zero point). Displayed as an additional indication of ph electrode system condition; 7pH is the optimum value for glass electrodes and 0pH for Antimony electrodes. Wash Function Monitoring ph Alarm 3 set to Wash (A3: Type, User Guide Section 5.4) see User Guide Section 2.3.3. Alarm 3 not set to Wash. 7

2 OPERATION 2.2 Operating Page 2.2.2 Dual (Bi-directional) PI Controller Note. The Dual (Bi-directional) PI Controller operating page replaces the Single Input ph operating page shown in Section 2.3.1 of the User Guide, IM/AX4PH. 7.00 ph 24.6 Deg.C Hi 8.00 Lo 6.00 Measured Values ph. Temperature. High and low control set points. 7.00 Control Mode 7.00 60.0 ph Manual ph Hi 8.00 Lo 6.00 7.00 ph 8.00 ph % Man High Setpoint Control Mode Measured ph. Control mode. Use the and keys to switch between manual (Manual) and automatic (Auto) control. Control Output Measured ph. Control output (%), manual (Man) or automatic (Auto). When Control Mode is set to Manual (see above), use the and keys to adjust the control output between 100 and 100%. High Control Set Point Measured ph. High control set point. Use the and keys to adjust the high control set point between 0.5 and 14pH. 7.00 ph 6.00 ph Low Setpoint Low Control Set Point Measured ph. Low control set point. Use the and keys to adjust the low control set point between 0 and 13.5pH. Note. The minimum span between low and high control set points is 0.5pH. Millivolts Continued on next page. 8

2 OPERATION 2.2 2.2.2 Operating Page Dual (Bi-directional) PI Controller Measured Millivolts 404 mv Millivolts Millivolts. 100.0 % 7.00 ph A: Slope & Check % Slope and ph Check Value % slope value. A value between the programmed minimum % slope value (see Set Min Slope in the CONFIG. SENSORS page User Guide Section 5.3) and 105% is displayed. If the value is outside these limits, check the electrode system. ph check value (zero point). Displayed as an additional indication of ph electrode system condition; 7pH is the optimum value for glass electrodes and 0pH for Antimony electrodes. Wash Function Monitoring ph Alarm 3 set to Wash (A3: Type, User Guide Section 5.4) see User Guide Section 2.3.3. Alarm 3 not set to Wash. 9

3 OPERATOR VIEWS 3.1 View Set Points Notes. The View Set Points page replaces the View Set Points page shown in Section 3.1 of the User Guide, IM/AX4PH. The parameter names and units of measurement displayed in the View Set Points page depend on the Probe Type setting for Sensor A in the CONFIG. SENSORS page see User Guide, Section 5.3. Those shown below are given as examples only. - VIEW SETPOINTS View Set Points This page shows alarm set points. The value of each of the set points is shown, together with the name of the parameter it is assigned to. Set point values and relay/led actions are programmable see User Guide, Section 5.4. Sensor A (ph), Alarm 1 Set Point - Off A1: Setpoint Note. If Controller is set to PID or Dual and is set to Time or Pulse (see Section 4.3), A1: Set Point is set to Off, regardless of the setting in the CONFIG. ALARMS page see User Guide, Section 5.4. Sensor A (Temperature), Alarm 2 Set Point - Off A2: Setpoint Note. If Controller is set to Dual (see Section 4.3) and for Base Controller is set to Time or Pulse (see Section 4.3.2), A2: Set Point is set to Off, regardless of the setting in the CONFIG. ALARMS page see User Guide, Section 5.4. 6.80 A3: Setpoint Sen.A ph Alarm 3 Set Point Temp.A 55.0 Deg.C A4: Setpoint Alarm 4 Set Point Note. Alarm 4 is available only if the optional analog output board is fitted. Alarm 5 Set Point - Off A5: Setpoint Note. Alarm 5 is available only if the optional analog output board is fitted. VIEW SETPOINTS VIEW OUTPUTS Return to main menu. SENSOR CAL. Security Code CONFIG. DISPLAY Sensor calibration enabled (User Guide, Section 5.3) see User Guide, Section 4.1. Alter Sec. Code not set to zero (User Guide, Section 5.7) see User Guide, Section 5.1. Alter Sec. Code set to zero (User Guide, Section 5.7) see User Guide, Section 5.2. 10

4 PROGRAMMING 4.1 Setting Up Three Term (PID) Control Parameters To enable a process to be controlled satisfactorily, the following conditions must apply: a) The process must be capable of reaching a natural balance with a steady load. b) It must be possible to introduce small changes into the system without destroying either the process or the product. The Proportional Band determines the gain of the system. (the gain is the reciprocal of the proportional band setting, e.g. a setting of 20% is equivalent to a gain of 5). If the proportional band is too narrow, the control loop may become unstable and cause the system to oscillate. With proportional band control only, the system normally stabilizes eventually but at a value which is offset from the set point. The addition of Integral Action Time removes the offset but, if set too short, can cause the system to go into oscillation. The introduction of Derivative Action Time reduces the time required by the process to stabilize. g) Set Derivative Time to: t (for P+I+D control) 8 t (for P+D control) 12 The analyzer is now ready for fine tuning by small adjustments to the P, I and D terms, after the introduction of a small disturbance of the set point. Process Variable Response Time 4.2 Manual Tuning Before starting up a new process or changing an existing one: a) Select the Configure Control page and ensure that Controller is set to PID see Section 4.3. b) Select the PID Controller page and set the following: Proportional Band 100% Integral Time 0 (off) see Section 4.3.1 Derivative Time 0 (off) Note. If the system goes into oscillation with increasing amplitude (Fig. 4.1 Mode B), reset the proportional band to 200%. If oscillation continues as in Mode B, increase the proportional band further until the system ceases to oscillate. If the system oscillates as in Fig. 4.1 Mode A, or does not oscillate, refer to step c). c) Reduce the Proportional Band by 20% increments and observe the response. Continue until the process cycles continuously without reaching a stable condition (i.e. a sustained oscillation with constant amplitude as shown in Mode C). This is the critical point. d) Note the cycle time 't' (Fig. 4.1 Mode C) and the Proportional Band (critical value) setting. e) Set Proportional Band to: 1.6 times the critical value (for P+D or P+I+D control) 2.2 times the critical value (for P+I control) 2.0 times the critical value (for P only control) f) Set Integral Time to: t (for P+I+D control) 2 t (for P+D control) 1.2 Process Variable Process Variable Time Mode A Response Time Time Mode B Response Time Cycle Time t Time Mode C Fig. 4.1 Control Conditions 11

4 PROGRAMMING 4.3 Configure Control Note. Applicable only if A: Probe Type is set to ph see User Guide, Section 5.3. - CONFIG. CONTROL Off PID - Dual Controller Controller Type Select the controller type: Off Disables the controller PID Single PID controller Dual Dual, bi-directional (acid/base) controller PID Controller Acid Controller CONFIG. CLOCK CONFIG. SECURITY Controller set to PID see Section 4.3.1. Controller set to Dual see Section 4.3.2. Optional analog output board fitted see User Guide, Section 5.6. Optional analog output board not fitted see User Guide, Section 5.7. 12

4 PROGRAMMING 4.3 Configure Control 4.3.1 Configure Single PID Controller Controller set to PID PID Controller Power Recovery See Section 4.4. Rev. Direct Control Action Control Action Set the required control action: Rev. Reverse acting see Fig. 1.2. Direct Direct acting see Fig. 1.3. Proportional Band Set the required proportional band between 0.1 and 999.9% in 0.1% increments. 100.0 % Man Proportional Band 100 Secs Integral Time Integral Action Time Set the integral action time between 1 and 7200 seconds in 1 second increments. Set to 0 to disable integral action time. 10.0Secs Derivative Time Derivative Action Time Set the derivative action time between 0.1 and 999.9 seconds in 0.1 second increments. Set to 0 to disable derivative action time. Note. Derivative control in ph applications could cause instability. It is therefore recommended that this is set to 0 in ph applications. Pulse Analog Time Set the required output type: Time Time proportioning (relay 1) Analog Analog output (analog output 1) Pulse Pulse frequency (relay 1) Pulses/Minute Cycle Time Output Range set to Time continued on next page. set to Analog continued on next page. set to Pulse continued on next page. 13

4 PROGRAMMING 4.3 4.3.1 Configure Control Configure Single PID Controller set to Time PID Controller 10.0 Secs Cycle Time Time Proportioning Output The Time Proportioning Output is interrelated to the retention time of the vessel and the flow of the chemical reagent and is adjusted experimentally to ensure that the chemical reagent is adequate to control the dosing under maximum loading. It is recommended that the Time Proportioning Output is adjusted in Manual Mode set to 100% valve output before setting up the PID parameters. The time proportioning output value is calculated using the following equation: control output x cycle time on time = 100 Set the cycle time, between 1.0 and 300.0 seconds in 0.1 second increments see Appendix B, Fig. B4 Mode C. Note. Changes to the cycle time do not take effect until the start of a new cycle. Output = 0% Permanently de-energized Output = 25% Energized De-energized 2.5s 7.5s Output = 50% Energized De-energized 5s 5s Output = 75% Energized De-energized 7.5s 2.5s Output = 100% Permanently energized Cycle Time = 10s Power Recovery See Section 5.8.2. CONFIG. SECURITY See Section 5.9. set to Analog 4-20mA 0-20mA 0-10mA Output Range Analog Output Set the analog current output range. PID Controller Power Recovery See Section 5.8.2. CONFIG. SECURITY See Section 5.9. 14

4 PROGRAMMING 4.3 4.3.1 Configure Control Configure Single PID Controller set to Pulse PID Controller 60 Pulses/Minute Pulse Frequency Ouput The pulse frequency output is the number of relay pulses per minute required for 100% control output. The Pulse Frequency Output is interrelated to the chemical reagent strength and the solution flow rate. The chemical reagent flowrate and pulse frequency is adjusted experimentally to ensure that the chemical reagent is adequate to control the dosing under maximum loading. Adjust the Pulse Frequency Output in Manual Mode and set to 100% valve output before setting up the PID parameters. For example, if the observed value on the display is 6 and the control point is 5 then the frequency needs to be increased. The actual number of pulses per minute is calculated using the following equation: % control output x pulse frequency output Actual pulses per minute = 100 Set the pulse frequency between 1 and 120 pulses per minute in 1 pulse per minute increments. Control Output 0 25 50 75 100 Pulse Frequency Output/Minute 1 0 0.25 0.50 0.75 1.00 10 0 2.5 5.0 7.5 10.0 50 0 12.5 25 37.5 50 120 0 30 60 90 120 Note. If the pulse frequency of 120 is reached then concentration of the reagent needs to be increased. Note. Changes to the pulse frequency do not take effect until the start of a new cycle. Output = 0% Permanently de-energized Output = 50% Energized De-energized 0.3s 2.1s Energized Output = 100% 0.3s 0.9s 0.3s 0.9s De-energized Examples. Pulse Frequency = 50 pulses per minute (1 pulse every 1.25s) Power Recovery CONFIG. SECURITY See Section 5.8.2. See Section 5.9. 15

4 PROGRAMMING 4.3 Configure Control 4.3.2 Configure Dual (Bi-directional) PI Controller Controller set to Dual Acid Controller Base Controller See page 18. 100.0 % Man Proportional Band Proportional Band Set the required proportional band between 0.1 and 999.9% in 0.1% increments. 100 Secs Integral Time Integral Time Set the integral action time between 1 and 7200 seconds in 1 second increments. Set to 0 to disable integral action time. Pulse Analog Time Set the required output type: Time Time proportioning (relay 1) Analog Analog output (analog output 1) Pulse Pulse frequency (relay 1) Cycle Time Output Range Pulses/Minute set to Time see next page. set to Analog see next page. set to Pulse see next page. 16

4 PROGRAMMING 4.3 4.3.2 Configure Control Configure Dual (Bi-directional) PI Controller set to Time 6.0 Secs Cycle Time Time Proportioning Output Set the cycle time between 1.0 and 300.0 seconds in 0.1 second increments. Note. See also Section 4.3.1 page 14. Acid Controller Base Controller See next page. CONFIG. CLOCK CONFIG. SECURITY Optional analog output board fitted see User Guide, Section 5.6. Optional analog output board not fitted see User Guide, Section 5.7. set to Analog 4-20mA 0-20mA 0-10mA Output Range Analog Output Set the analog current output range. Acid Controller Base Controller See next page. CONFIG. CLOCK CONFIG. SECURITY Optional analog output board fitted see User Guide, Section 5.6. Optional analog output board not fitted see User Guide, Section 5.7. set to Pulse 60 Pulses/Minute Pulse Frequency Output Set the pulse frequency between 1 and 120 pulses per minute in 1 pulse per minute increments. Note. See also Section 4.3.1 page 15. Acid Controller Base Controller See next page. CONFIG. CLOCK CONFIG. SECURITY Optional analog output board fitted see User Guide, Section 5.6. Optional analog output board not fitted see User Guide, Section 5.7. 17

4 PROGRAMMING 4.3 4.3.2 Configure Control Configure Dual (Bi-directional) PI Controller Controller set to Dual Base Controller Power Recovery See Section 4.4. Proportional Band Set the required proportional band between 0.1 and 999.9% in 0.1% increments. 100.0 % Man Proportional Band 100 Secs Integral Time Integral Time Set the integral action time between 1 and 7200 seconds in 1 second increments. Set to 0 to disable integral action time. Pulse Analog Time Set the required output type: Time Time proportioning (relay 2) Analog Analog output (analog output 2) Pulse Pulse frequency (relay 2) Cycle Time Output Range Pulses/Minute set to Time see page 14. set to Analog see page 14. set to Pulse see page 15. 18

4 PROGRAMMING 4.4 Configure Power Failure Recovery Mode Power Recovery Last Manual Auto Power Rec. Mode Power Failure Recovery Mode When power to the analyzer is restored, Control Mode (see Section 2.2) is set automatically according to the chosen Power Failure Recovery Mode. Set the required mode: Auto Control Mode is set to Auto irrespective of its setting prior to the power failure. Manual Control Mode is set to Manual irrespective of its setting prior to the power failure. Control Output (see Section 2.2) is set to the level set in the Default Output frame below. Last Control Mode and Control Output are set to the same state as that set prior to the power failure. Power Recovery 50.0 % Default Output Default Output If Controller is set to PID (see Section 4.3), set the default output required between 0 and 100% in 0.1% increments. If Controller is set to Dual (see Section 4.3), set the default output required between 100 and 100% in 0.1% increments. Notes. A setting of 1 to 100% represents a direct output. A setting of 1 to 100% represents a reverse output. A setting of 0% represents no output i.e. both direct and reverse outputs are switched off. CONFIG. CONTROL CONFIG. CLOCK CONFIG. SECURITY Return to main menu. Optional analog output board fitted see User Guide, Section 5.6. Optional analog output board not fitted see User Guide, Section 5.7. 19

NOTES 20

PRODUCTS & CUSTOMER SUPPORT Products Automation Systems for the following industries: Chemical & Pharmaceutical Food & Beverage Manufacturing Metals and Minerals Oil, Gas & Petrochemical Pulp and Paper Drives and Motors AC and DC Drives, AC and DC Machines, AC Motors to 1kV Drive Systems Force Measurement Servo Drives Customer Support We provide a comprehensive after sales service via a Worldwide Service Organization. Contact one of the following offices for details on your nearest Service and Repair Centre. United Kingdom ABB Limited Tel: +44 (0)1453 826661 Fax: +44 (0)1453 829671 United States of America ABB Inc. Tel: +1 (0) 775 850 4800 Fax: +1 (0) 775 850 4808 Controllers & Recorders Single and Multi-loop Controllers Circular Chart and Strip Chart Recorders Paperless Recorders Process Indicators Flexible Automation Industrial Robots and Robot Systems Flow Measurement Electromagnetic Magnetic Flowmeters Mass Flowmeters Turbine Flowmeters Flow Elements Marine Systems & Turbochargers Electrical Systems Marine Equipment Offshore Retrofit and Referbishment Process Analytics Process Gas Analysis Systems Integration Transmitters Pressure Temperature Level Interface Modules Valves, Actuators and Positioners Control Valves Actuators Positioners Water, Gas & Industrial Analytics Instrumentation ph, Conductivity and Dissolved Oxygen Transmitters and Sensors Ammonia, Nitrate, Phosphate, Silica, Sodium, Chloride, Fluoride, Dissolved Oxygen and Hydrazine Analyzers. Zirconia Oxygen Analyzers, Katharometers, Hydrogen Purity and Purge-Gas Monitors, Thermal Conductivity. Client Warranty Prior to installation, the equipment referred to in this manual must be stored in a clean, dry environment, in accordance with the Company's published specification. Periodic checks must be made on the equipment's condition. In the event of a failure under warranty, the following documentation must be provided as substantiation: 1. A listing evidencing process operation and alarm logs at time of failure. 2. Copies of all storage, installation, operating and maintenance records relating to the alleged faulty unit.

ABB has Sales & Customer Support expertise in over 100 countries worldwide www.abb.com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in UK (03.06) ABB 2006 IM/AX4PID Issue 5 ABB Limited Oldends Lane, Stonehouse Gloucestershire GL10 3TA UK Tel: +44 (0)1453 826661 Fax: +44 (0)1453 829671 ABB Inc. Analytical Instruments 9716 S. Virginia St., Ste. E Reno, Nevada 89521 USA Tel: +1 (0) 775 850 4800 Fax: +1 (0) 775 850 4808