PERCEPTUAL EVALUATION OF IMAGE DENOISING ALGORITHMS. Kai Zeng and Zhou Wang

Similar documents
PERCEPTUAL QUALITY ASSESSMENT OF DENOISED IMAGES. Kai Zeng and Zhou Wang

QUALITY ASSESSMENT OF IMAGES UNDERGOING MULTIPLE DISTORTION STAGES. Shahrukh Athar, Abdul Rehman and Zhou Wang

No-Reference Quality Assessment of Contrast-Distorted Images Based on Natural Scene Statistics

PerSIM: MULTI-RESOLUTION IMAGE QUALITY ASSESSMENT IN THE PERCEPTUALLY UNIFORM COLOR DOMAIN. Dogancan Temel and Ghassan AlRegib

GRADIENT MAGNITUDE SIMILARITY DEVIATION ON MULTIPLE SCALES FOR COLOR IMAGE QUALITY ASSESSMENT

OBJECTIVE IMAGE QUALITY ASSESSMENT OF MULTIPLY DISTORTED IMAGES. Dinesh Jayaraman, Anish Mittal, Anush K. Moorthy and Alan C.

COLOR IMAGE DATABASE TID2013: PECULIARITIES AND PRELIMINARY RESULTS

A New Scheme for No Reference Image Quality Assessment

SUBJECTIVE QUALITY ASSESSMENT OF SCREEN CONTENT IMAGES

No-reference Synthetic Image Quality Assessment using Scene Statistics

OBJECTIVE QUALITY ASSESSMENT OF MULTIPLY DISTORTED IMAGES

NO-REFERENCE IMAGE BLUR ASSESSMENT USING MULTISCALE GRADIENT. Ming-Jun Chen and Alan C. Bovik

Subjective Versus Objective Assessment for Magnetic Resonance Images

PERCEPTUAL EVALUATION OF MULTI-EXPOSURE IMAGE FUSION ALGORITHMS. Kai Zeng, Kede Ma, Rania Hassen and Zhou Wang

A New Scheme for No Reference Image Quality Assessment

Quality Measure of Multicamera Image for Geometric Distortion

Why Visual Quality Assessment?

ORIGINAL ARTICLE A COMPARATIVE STUDY OF QUALITY ANALYSIS ON VARIOUS IMAGE FORMATS

COLOR IMAGE QUALITY EVALUATION USING GRAYSCALE METRICS IN CIELAB COLOR SPACE

EVALUATION OF 60 FULL-REFERENCE IMAGE QUALITY METRICS ON THE CID:IQ. Marius Pedersen. Gjøvik University College, Gjøvik, Norway

VISUAL QUALITY INDICES AND LOW QUALITY IMAGES. Heinz Hofbauer and Andreas Uhl

Image Quality Assessment Techniques V. K. Bhola 1, T. Sharma 2,J. Bhatnagar

COLOR-TONE SIMILARITY OF DIGITAL IMAGES

Visual Attention Guided Quality Assessment for Tone Mapped Images Using Scene Statistics

IJSER. No Reference Perceptual Quality Assessment of Blocking Effect based on Image Compression

Image De-Noising Using a Fast Non-Local Averaging Algorithm

AN IMPROVED NO-REFERENCE SHARPNESS METRIC BASED ON THE PROBABILITY OF BLUR DETECTION. Niranjan D. Narvekar and Lina J. Karam

No-Reference Image Quality Assessment Using Euclidean Distance

Review Paper on. Quantitative Image Quality Assessment Medical Ultrasound Images

Learning Pixel-Distribution Prior with Wider Convolution for Image Denoising

A Simple Second Derivative Based Blur Estimation Technique. Thesis. the Graduate School of The Ohio State University. Gourab Ghosh Roy, B.E.

Objective Image Quality Assessment Current Status and What s Beyond

IDENTIFICATION OF SUITED QUALITY METRICS FOR NATURAL AND MEDICAL IMAGES

arxiv: v9 [cs.cv] 8 May 2017

IEEE Signal Processing Letters: SPL Distance-Reciprocal Distortion Measure for Binary Document Images

Impact of the subjective dataset on the performance of image quality metrics

No-Reference Image Quality Assessment using Blur and Noise

No-Reference Perceived Image Quality Algorithm for Demosaiced Images

Empirical Study on Quantitative Measurement Methods for Big Image Data

Image Distortion Maps 1

HDR IMAGE COMPRESSION: A NEW CHALLENGE FOR OBJECTIVE QUALITY METRICS

A Review: No-Reference/Blind Image Quality Assessment

Full Reference Image Quality Assessment Method based on Wavelet Features and Edge Intensity

arxiv: v4 [cs.cv] 20 Jun 2016

Perceptual-Based Locally Adaptive Noise and Blur Detection. Tong Zhu

Multiresolution Bilateral Filtering for Image Denoising Ming Zhang and Bahadir K. Gunturk

The interest in objective

S 3 : A Spectral and Spatial Sharpness Measure

Image Quality Assessment for Defocused Blur Images

Visual Quality Assessment for Projected Content

IMAGE EXPOSURE ASSESSMENT: A BENCHMARK AND A DEEP CONVOLUTIONAL NEURAL NETWORKS BASED MODEL

A Robust Nonlinear Filtering Approach to Inverse Halftoning

APJIMTC, Jalandhar, India. Keywords---Median filter, mean filter, adaptive filter, salt & pepper noise, Gaussian noise.

Image Enhancement for Astronomical Scenes. Jacob Lucas The Boeing Company Brandoch Calef The Boeing Company Keith Knox Air Force Research Laboratory

A No Reference Image Blur Detection using CPBD Metric and Deblurring of Gaussian Blurred Images using Lucy-Richardson Algorithm

Analysis and Improvement of Image Quality in De-Blocked Images

Outline of the presenta<on. QA and codec performance evalua<on

ISSN Vol.03,Issue.29 October-2014, Pages:

Hyperspectral Image Denoising using Superpixels of Mean Band

Texture Enhanced Image denoising Using Gradient Histogram preservation

Artifacts Reduced Interpolation Method for Single-Sensor Imaging System

Main Subject Detection of Image by Cropping Specific Sharp Area

PERCEPTUAL QUALITY ASSESSMENT OF HDR DEGHOSTING ALGORITHMS

Smooth region s mean deviation-based denoising method

Denoising Scheme for Realistic Digital Photos from Unknown Sources

The impact of skull bone intensity on the quality of compressed CT neuro images

No-Reference Image Quality Assessment Based on Statistics of Local Ternary Pattern

INTERNATIONAL JOURNAL OF RESEARCH IN COMPUTER APPLICATIONS AND ROBOTICS ISSN

3D display is imperfect, the contents stereoscopic video are not compatible, and viewing of the limitations of the environment make people feel

International Journal of Scientific & Engineering Research, Volume 4, Issue 7, July ISSN

Efficient Target Detection from Hyperspectral Images Based On Removal of Signal Independent and Signal Dependent Noise

High Density Impulse Noise Removal Using Robust Estimation Based Filter

GRADIENT HISTOGRAM ESTIMATION AND PRESERVATION FOR IMAGE DENOISING USING DWT

Perceptual Blur and Ringing Metrics: Application to JPEG2000

Analysis of the SUSAN Structure-Preserving Noise-Reduction Algorithm

DENOISING DIGITAL IMAGE USING WAVELET TRANSFORM AND MEAN FILTERING

FILTER FIRST DETECT THE PRESENCE OF SALT & PEPPER NOISE WITH THE HELP OF ROAD

A Fast Median Filter Using Decision Based Switching Filter & DCT Compression

LEARNING ADAPTIVE PARAMETER TUNING FOR IMAGE PROCESSING. J. Dong, I. Frosio*, J. Kautz

Enhanced DCT Interpolation for better 2D Image Up-sampling

Target detection in side-scan sonar images: expert fusion reduces false alarms

Halftoning-Inspired Methods for Foveation in Variable-Acuity Superpixel Imager* Cameras

Objective and subjective evaluations of some recent image compression algorithms

A Spatial Mean and Median Filter For Noise Removal in Digital Images

IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, VOL. 14, NO. 10, OCTOBER

A Novel Method for Enhancing Satellite & Land Survey Images Using Color Filter Array Interpolation Technique (CFA)

Image Quality Measurement Based On Fuzzy Logic

arxiv: v1 [cs.cv] 8 Nov 2018

MACHINE evaluation of image and video quality is important

Image Quality Assessment by Comparing CNN Features between Images

NOWADAYS, digital images are captured by various stationary

PERCEPTUAL QUALITY ASSESSMENT OF HDR DEGHOSTING ALGORITHMS

Issues in Color Correcting Digital Images of Unknown Origin

Fast Inverse Halftoning Algorithm for Ordered Dithered Images

Visual Quality Assessment using the IVQUEST software

Quaternion Structural Similarity: A New Quality Index for Color Images

Photo Quality Assessment based on a Focusing Map to Consider Shallow Depth of Field

A High-Quality Denoising Dataset for Smartphone Cameras

Evaluating and Improving Image Quality of Tiled Displays

SSIM based Image Quality Assessment for Lossy Image Compression

Transcription:

PERCEPTUAL EVALUATION OF IMAGE DENOISING ALGORITHMS Kai Zeng and Zhou Wang Dept. of Electrical & Computer Engineering, University of Waterloo, Waterloo, ON, Canada ABSTRACT Image denoising has been an active research topic in the past decades for its broad real-world applications, but surprisingly little work has been dedicated to the quality assessment of denoised images. In this work, we first build a database that contains noisy images at different noise levels and denoised images created by both classical and state-of-the-art denoising algorithms. We then carry out a subjective experiment using a multi-stimulus ranking approach to evaluate and compare the quality of the denoised images. Data analysis shows that there are both considerable agreement and significant variations between human subjects on their opinions of denoised images. Our results also show that state-of-the-art objective image quality models only moderately correlate with subjective opinions, and further investigations that involve both structural fidelity and naturalness measures are desirable in future development of advanced objective models. Index Terms image quality assessment, image denoising, human visual system 1. INTRODUCTION Real-world images are subject to noise contaminations during acquisition, transmission, and processing. Denoising of images is highly desirable, not only to produce better perceptual quality, but also to help improve the performance of the subsequent processes such as compression, segmentation, resizing, and recognition. In the past decades, a large number of image denoising algorithms have been proposed, ranging from simple linear filtering to sophisticated methods based on advanced statistical image models. With multiple denoising algorithms available, a natural question is which one produces the best quality images. Without an appropriate quality measure, fair comparison is impossible and further improvement is aimless. Surprisingly, in the literature of image quality assessment (IQA), little work has been dedicated to the evaluation of denoised images. In practice, researchers often resort to common IQA measures such as peak signal-to-noiseratio (PSNR) and the structural similarity index (SSIM) [1] to compare image quality and denoising algorithms, but proper validations of these measures are lacking. Since human eyes are the ultimate receivers in most applications, subjective test is considered the most reliable approach to evaluate the quality of denoised images. There have been a number of well-known subjective database for image quality assessment (IQA) [2, 3, 4, 5, 6], but unfortunately, none of them contains denoised images as a category. Consequently, direct comparison of different denoising algorithms cannot be performed, and whether existing objective IQA measures are proper quality indicators of denoised images remains an unanswered problem. The purpose of this work is first to build a database that contains noisy images at different noise levels and denoised images produced by different denoising algorithms. Subjective experiment is then conducted using the database, and the results can be used to 1) study the human behaviors in evaluating denoised image quality; 2) evaluate the relative performance of classical and state-of-the-art denoising algorithms; and 3) test the performance of existing objective IQA algorithms in predicting the subjective quality of denoised images and explore potential ways to improve them. 2. SUBJECTIVE QUALITY ASSESSMENT 2.1. Image Database Ten original high-quality natural images of size 512 512 shown in Fig. 1 are selected from the CSIQ database [4] to cover diverse natural image content, including humans, animals, plants, natural sceneries, and man-made architectures. Independent white Gaussian noise of three levels is added to each image with noise standard deviation σ n equaling 15, 30, and 50, respectively. Eight denoising algorithms are selected, which include simple operators (1) linear Gaussian filter (with the standard deviation of the Gaussian profile equaling 11 pixels) and (2) locally adaptive Wiener filter (MATLAB Wiener2D function with sliding window size 3), as well as state-of-the-art denoising algorithms (3) BLS-GSM [7], (4) SURE-LET [8], (5) BM3D [9], (6) K-SVD [10], (7) SADCT [11], and (8) CSR [12]. These algorithms are chosen to cover a diverse types of denoisers in terms of methodology and behavior. Specifically, the linear Gaussian filter tends to over-smooth the image, resulting in blurriness; the local adaptive Wiener filter is likely to keep structures but does not cleanly remove the noise, especially at high noise levels; SURE-LET often creates non-existing structural artifacts in smooth areas; and

Fig. 1. Original reference images in the database. BM3D and CSR demonstrate strong noise removal capability while keeping the image contrast, but meanwhile may remove subtle image details as noise. In all cases, default parameter settings are adopted without any tuning for better quality. In the end, a total of 240 denoised images are generated, which are divided into 30 image sets of 8 images each, where the images in the same set are created from the same original image at the same noise level. For better visualization, a group of cropped and enlarged sample noisy images, together with their corresponding denoised images are shown in Fig. 2. 2.2. Subjective Experiment The subjective experiment was conducted on a PC with Intel(R) Core(TM) i7-2600 dual 3.40GHz CPU. Images were displayed on an LCD monitor at a resolution of 2560 1600 pixel with Truecolor (32bit) at 60Hz. The monitor was calibrated in accordance with the recommendations of ITU-T BT.500 [13]. The test environment was setup as a normal indoor office workspace with ordinary illumination level. A customized Matlab figure window was used to render the images on the screen. During the test, all 8 denoised images in the same set are shown to the subject at the same time in random spatial order on one computer screen at actual pixel resolution. The order of image sets is also randomized and thus different for each subject. The study adopted a quality ranking strategy without showing the reference image. A total of 20 naïve observers, mostly graduate students at the University of Waterloo, including 12 males and 8 females aged between 22 and 30, participated in the subjective experiment. For each image set, the subject was asked to rank the perceptual quality of the 8 images from the best to the worst with 8 levels. The subjects have the freedom to move their positions for better observation. All subject ratings were recorded with pen and paper during the study. To minimize the influence of fatigue effect, the length of a session was limited to 30 minutes. 2.3. Discussion on Subjective Experiment Method The strategy of subjective experiment is not a trivial issue and is worth further discussion. There could be three methods to conduct the experiment. In a paired comparison method [14], a pair of images are shown at the same time to the subject, who is asked to give preference in terms of quality. It is typically an easy task for the subject, and previous studies showed that it produces reliable results [14]. However, this approach requires a large number of paired comparisons and is very inefficiency. Meanwhile it may cause the transition problem (a judgement of A > B, B > C, C > A given by the same subject). This may not be a major issue if the purpose is to obtain the average preference of many subjects, but becomes a difficult problem to handel when the behavior of an individual subject needs to be analyzed and compared with the mean subject opinions. In a single-stimulus test method, one image is shown to the subject at one time and the subject is asked to provide a single score on a quality scale. This method directly collects absolute quality scores that are meaningful for cross-content and cross-distortion comparisons. However, the scores collected in such an experiment may be sensitive to the tasks and instructions given to the subjects. Moreover, calibrations across subjects are necessary to align the scores given by different subject. In a multi-stimulus ranking method, multiple images are presented to the subject together and the subjects rank the images from the lowest to the highest quality. This method has many advantages It is highly efficient, without any transi-

KRCC SRCC 1 Noisy 0.8 0.6 Gaussian Filter2 0.4 0.2 Adaptive Wiener Filter2 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Subjects 1 0.8 SURELET 0.6 0.4 0.2 K-SVD 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Subjects BLS-GSM Fig. 3. Mean and std of SRCC and KRCC values between individual subject and average subject rankings. The rightmost column represents the performance of an average subject. SADCT BM3D tion problem, and the results can be directly compared across subjects. On the other hand, this approach is often constrained by the physical testing conditions. For example, the screen size may not be enough to show multiple images, and the backlight, viewing angle and viewing distance may not be uniform across the screen. In reality, the best subjective testing method should be determined by the nature of the experiment to achieve a compromise between effectiveness, accuracy, robustness and efficiency. In the current study, the multi-stimulus ranking method fits well with our target and is thus adopted. CSR 3. ANALYSIS AND DISCUSSION 3.1. Analysis of Subjective Data Fig. 2. Sample denoised images (cropped and enlarged for visibility). Left: σ n = 15; Middle: σ n = 30; Right: σ n = 50. After the subjective test, 3 outlier subjects are removed based on the outlier removal scheme in [13], resulting in 17 valid subjects. The final rank-order within each image set is computed as the average ranking from all valid subjects. Considering these average rank-orders for all image sets as the

Best Worst Gaussian2 Wiener2 SURE-LET K-SVD BLS-GSM SADCTBM3D CSR Fig. 4. Mean and std of subjective rankings of individual denoiser across all image sets. ground truth, we can observe the performance of each individual subject by comparing their rank-order with the ground truth for image set, and then average the performance over all 30 image sets. The comparison is based on Spearman s rank-order correlation coefficient (SRCC) and Kendall s rank-order correlation coefficient (KRCC). The mean and standard deviation of SRCC and KRCC values for each individual subject are depicted in Fig. 3. It can be seen that there is a quite considerable agreement between different subjects on ranking the quality of denoised images. The average performance across all individual subjects is also given in the rightmost column in Fig. 3. This provides a general idea about the performance of an average subject. The average SRCC and KRCC results of all 8 denoising algorithms over all 30 image sets are summarized in Fig. 4. It can be observed that state-of-the-art denoisers such as BM3D [9] and CSR [12] perform significantly better than more traditional methods. On the other hand, from the sizes of the error bars, we observe significant variations between subject preference of the best denoisers. It is worth mentioning that this only provides a rough comparison of the relative performance of the denoising algorithms, where default parameters are used without fine tuning. Besides, computational complexity is not a factor under consideration. 3.2. Testing Objective IQA Algorithms Using the database, we test 12 full-reference (FR), 2 reducedreference (RR), and 4 no-reference (NR) objective IQA models, and the mean (µ) and standard deviation (σ) of SRCC and KRCC values across all 30 image sets are given in Table 1. Larger µ values of SRCC and KRCC indicate better consistency with subjective opinions, while smaller σ values suggest more stable performance across image sets. Table 1. Performance of objective IQA models IQA model SRCC KRCC µ σ µ σ PSNR FR 0.872 0.089 0.759 0.132 VSNR[16] FR 0.817 0.167 0.723 0.179 WSNR[17] FR 0.888 0.076 0.797 0.113 IW-PSNR[18] FR 0.745 0.210 0.644 0.216 NQM[19] FR 0.806 0.138 0.690 0.167 IFC[20] FR 0.805 0.167 0.673 0.174 VIF[21] FR 0.579 0.306 0.467 0.261 VIFP[21] FR 0.857 0.107 0.737 0.146 SSIM[1] FR 0.847 0.113 0.721 0.150 MS-SSIM[22] FR 0.853 0.108 0.728 0.141 IW-SSIM[18] FR 0.838 0.155 0.721 0.160 RFSIM[23] FR 0.862 0.125 0.747 0.151 RRED[24] RR 0.651 0.211 0.537 0.198 RRIQA[25] RR 0.029 0.323 0.000 0.258 AniNRIQA[26] NR 0.390 0.362 0.329 0.314 BRISQUE[27] NR 0.188 0.430 0.134 0.366 BIQI[28] NR 0.083 0.351 0.033 0.295 NIQE[29] NR 0.513 0.338 0.410 0.295 It can be observed that state-of-the-art RR and NR approaches do not provide adequate predictions of denoised image quality. Several FR models (PSNR, WSNR, VIFP, SSIM, MS-SSIM, IW-SSIM, RFSIM) are moderately correlated with subjective scores, but somewhat surprisingly, these models include PSNR, which was widely criticized for its poor prediction of perceptual image quality in general [15]. The above test results imply that there is significant space for future improvement of objective models. One useful observation we have is that state-of-the-art structural fidelity measures such as SSIM and MS-SSIM can very well predict the loss or distortion of local structural details, but fail to capture the degradation in naturalness in the denoised images. This suggests that more accurate objective IQA models can be built by combining structural fidelity and naturalness measures. Our preliminary results show that by combining SSIM with naturalness models built on statistical image models, significantly improved performance can be achieved. These results will be refined and published in our future publications. 4. CONCLUSION We make one of the first attempts dedicated to quality assessment of denoised images. A database of denoised images was created, followed by subjective experiment and data analysis. Our results are somewhat surprising, suggesting that well-known objective IQA methods are quite limited in predicting the quality of denoised images. This motivates us to develop advanced objective models, which, based on our cur-

rent understanding, should incorporate both structural fidelity and naturalness assessment. Optimal design of future image denoising algorithms based on novel quality assessment measures is another promising topic worth further investigation. 5. REFERENCES [1] Z. Wang, A. C. Bovik, H. R. Sheikh, and E. P. Simoncelli, Image quality assessment: From error visibility to structural similarity, IEEE Trans. Image Process., vol. 13, no. 4, pp. 600 612, Apr. 2004. [2] H. R. Sheikh, Z. Wang, L. Cormack, and A. C. Bovik, LIVE image quality assessment database release 2, http:// live.ece.utexas.edu/research/quality/. [3] N. Ponomarenko, V. Lukin, A. Zelensky, K. Egiazarian, M. Carli, and F. Battisti, TID2008 - a database for evaluation of full-reference visual quality assessment metrics, Advances of Modern Radioelectronics, vol. 10, pp. 30 45, 2009. [4] E. C. Larson and D. M. Chandler, Most apparent distortion: full-reference image quality assessment and the role of strategy, Journal of Electronic Imaging, vol. 19, no. 1, Jan. 2010. [5] D. Jayaraman, A. Mittal, A. K. Moorthy, and A. C. Bovik, Objective quality assessment of multiply distorted images, in IEEE Asilomar Conference on Signals, Systems and Computers, Nov. 2012, pp. 1693 1697. [6] N. Ponomarenko, O. Ieremeiev, V. Lukin, K. Egiazarian, L. Jin, J. Astola, B. Vozel, K. Chehdi, M. Carli, F. Battisti, and C.- C. Jay Kuo, Color image database TID 2013: peculiarities and preliminary results, in European Workshop on Visual Information Processing, Jun. 2013. [7] J. Portilla, V. Strela, M. J. Wainwright, and E. P. Simoncelli, Image denoising using scale mixtures of Gaussians in the wavelet domain, IEEE Trans. Image Process., vol. 12, pp. 1338 1351, 2003. [8] F. Luisier, T. Blu, and M. Unser, SURE-LET for orthonormal wavelet-domain video denoising, IEEE Trans. Circuits Syst. Video Tech., vol. 20, no. 6, pp. 913 919, 2010. [9] K. Dabov, A. Foi, V. Katkovnik, and K. Egiazarian, Image denoising by sparse 3-D transform-domain collaborative filtering, IEEE Trans. Image Process., vol. 16, pp. 2080 2095, 2007. [10] M. Aharon, M. Elad, and A. Bruckstein, K-SVD: An algorithm for designing overcomplete dictionaries for sparse representation, IEEE Trans. Signal Process., vol. 11, pp. 4311 4322, 2006. [11] A. Foi, V. Katkovnik, and K. Egiazarian, Pointwise shapeadaptive dct for high-quality denoising and deblocking of grayscale and color images, IEEE Trans. Image Process., vol. 16, no. 5, pp. 1395 1411, May 2007. [12] W. S. Dong, X. Li, L. Zhang, and G. M. Shi, Sparsity-based image denoising vis dictionary learning and structural clustering, in IEEE Conf. Computer Vision and Pattern Rec. (CVPR), 2011. [13] ITU-R BT.500-12, Recommendation: Methodology for the subjective assessment of the quality of television pictures, Nov. 1993. [14] H. A. David, The Method of Paired Comparisons, Oxford University Press, New York, 1988. [15] Z. Wang and A. C. Bovik, Mean squared error: Love it or leave it? A new look at signal fidelity measures, vol. 26, no. 1, pp. 98 117, Jan. 2009. [16] D.M. Chandler and S.S. Hemami, VSNR: A wavelet-based visual signal-to-noise ratio for natural images, IEEE Trans. Image Process., vol. 16, pp. 2284 2298, 2007. [17] T. Mitsa and K. L. Varkur, Evaluation of contrast sensitivity functions for the formulation of quality measures incorporated in halftoning algorithms, in IEEE Inter. Conf. Acoustic, Speech, and Signal Process. (ICASSP), 1993, april 1993, vol. 5, pp. 301 304 vol.5. [18] Z. Wang and Q. Li, Information content weighting for perceptual image quality assessment, IEEE Trans. Image Process., vol. 20, no. 5, pp. 1185 1198, May 2011. [19] N. Damera-Venkata, T. D. Kite, W. S. Geisler, B. L. Evans, and A. C. Bovik, Image quality assessment based on a degradation model, IEEE Trans. Image Process., vol. 9, no. 4, pp. 636 650, Apr. 2000. [20] H. R. Sheikh, A. C. Bovik, and G. de Veciana, An information fidelity criterion for image quality assessment using natural scene statistics, IEEE Trans. Image Process., vol. 14, no. 12, pp. 2117 2128, Dec. 2005. [21] H. R. Sheikh and A. C. Bovik, Image information and visual quality, IEEE Trans. Image Process., vol. 15, no. 2, pp. 430 444, Feb. 2006. [22] Z. Wang, E. P. Simoncelli, and A. C. Bovik, Multiscale structural similarity for image quality assessment, in IEEE Asilomar Conference on Signals, Systems and Computers, Nov. 2003, vol. 2, pp. 1398 1402. [23] Z. Lin, Z. Lei, and M. Xuanqin, RFSIM: A feature based image quality assessment metric using Riesz transforms, in IEEE Inter. Conf. Image Process. (ICIP), 2010, Sept. 2010, pp. 321 324. [24] R. Soundararajan and A. C. Bovik, Rred indices: Reduced reference entropic differencing for image quality assessment, IEEE Trans. Image Process., vol. 21, no. 2, pp. 517 526, 2012. [25] Z. Wang and E. P. Simoncelli, Reduced-reference image quality assessment using a wavelet-domain natural image statistic model, in Human Vision and Electronic Imaging X, Proc. SPIE, San Jose, CA, January 2005, vol. 5666. [26] S. Gabarda and G. Cristóbal, Blind image quality assessment through anisotropy, J. Opt. Soc. Am. A, vol. 24, no. 12, pp. B42 B51, Dec. 2007. [27] A. Mittal, A. K. Moorthy, and A. C. Bovik, No-reference image quality assessment in the spatial domain, IEEE Trans. Image Process., vol. 21, no. 12, pp. 4695 4708, Dec. 2012. [28] A. K. Moorthy and A. C. Bovik, A two-step framework for constructing blind image quality indices, IEEE Signal Process. Letters, vol. 17, no. 5, pp. 513 516, 2010. [29] A. Mittal, R. Soundararajan, and A. C. Bovik, Making a completely blind image quality analyzer, IEEE Signal Process. Letters, 2012.