RS Pro ENGLISH. Datasheet

Similar documents
RS Pro ENGLISH. Datasheet

Jewell DPM EINE BEST IN CLASS

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

AMIK 200 / 201 Technical Data Sheet

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

AMIK Three Phase Digital Panel Meters

Programmable DPM RISH EINE

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Application: Salient Features: Products Features:

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Data Sheet. RISH Master Record %THD

Digital Multifunction Instrument - Rish Master 3440

Technical Data Sheet AMIK 300 / 301

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Technical Data Sheet. x1000. kwh R Y B

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Technical Data Sheet

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Alpha 50. Technical Data Sheet. Special Features

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

OPERATING MANUAL Rish Eine. Size: 48 x 96 Size: 96 x 96

SPECIFICATION FOR OVERCURRENT RELAYS

High precision measurement system for current and voltage IHC-A/B-RM01/03

Solid-state Timer H3DS

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Overcurrent Protection / 7SJ45

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Theta 20A / 20V. Technical Data Sheet. Special Features

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Energy Management Energy Analyzer Type EM210 MID

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

08/07/2015

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Technical Datasheet. Delta Power 1000A / 400A AC-DC

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Output Voltage* (nom.)(adjustable)

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

GAMMA 20 DIGITAL MULTIMETER

OPERATING MANUAL PROGRAMMABLE DPM. Size: 48 x 96 Size: 96 x 96

Energy Management Energy Meter Type EM21 72R Retro-Fit

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Integra 1560 and 1580 Digital Transducer Systems

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

22/10/2012

Solid-state Twin Timer

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

Output Voltage nom. (adjustable)

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Data Sheet. Earth Leakage Relay RISH ELR/ELR+/ELR VI/ELR VI(NE) A V RISH ELR VI. Record. Digital Protection Relay RESET TEST ENTER

Output Voltage nom. (adjustable)

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

BIODEX MULTI- JOINT SYSTEM

02/11/2015

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

RE17LLBM asymmetrical flashing relay s V AC - solid state output

Energy Management Energy Meter Type EM110

C series Product brief

GEMINI PRESETTABLE DUAL RATE INDICATOR WITH RATIO (A/B)

RISH ELR Earth Leakage Relay Preliminary Datasheet True RMS Measurement Trip relay cum DPM CBCT Open Detection 4 digit 7 segment LED display

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

02/11/2015

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Chapter 6 Specifications

05/09/2012

Transcription:

Datasheet ENGLISH Article No: 136-5390 Digital AC Ammeter, 48x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5391 Digital AC Ammeter, 96x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5393 Digital AC Voltmeter, 48x96, 3Phase, 100-500VLL (57.7-288V L-N) AC, Supply 40-300V ac/dc 136-5394 Digital AC Voltmeter, 96x96, 3Phase, 100-500VLL (57.7-288V L-N) AC, Supply 40-300V ac/dc

The digital panel meters (DPM) have been designed for industrial applications, which frequently require precise and onsite adjustment of the display range. It can be used in industrial automation and for laboratory uses. DPM measures important electrical parameters in 3 phase 4 Wire, 3 phase 3 Wire and single phase Network & replaces the multiple analogue panel meters. Benefits: Fast & Easy Installation on panel without any need of external swivel screws (clip-in mounting for 96x96 size only) True RMS measurement. 4 Digits ultra bright LED Display (up to 9999). On site Programmable CT/PT Ratios. User selectable CT Secondary 1A/5A. User selectable PT Secondary from 100 VLL to 500 VLL. User selectable 3ph3wire / 3ph4wire / single phase Network. Wide auxiliary Power Supply which can accept any input between 40V 300V AC/DC. Storage of MIN / MAX values. Product Features True RMS measurement The instrument measures distorted waveform up to 15th Harmonic. On site programmable PT/CT ratios: It is possible to program primary of external potential Transformer (PT) for Voltage DPM & primary of external Current Transformer (CT) for Current DPM on site via front panel keys by entering into Programming mode. User selectable CT Secondary 5A/1A The secondary of external Current Transformer (CT) can be programmed on site to either 5A or 1A for Current DPM using front panel keys. User selectable PT Secondary The secondary of external Potential Transformer (PT) can be programmed on site from 100 VLL to 500 VLL for Voltage DPM using front panel keys. Higher Security Provides Security with user programmable password protection. User selectable CT Primary The Primary of current transformer can be programmed on site from 1A to 999kA for Current DPM using front panel key. User selectable PT Primary The Primary of Potential transformer can be programmed on site from 100V to 999kV for Voltage DPM using front panel keys. User selectable 3 phase 3Wire or 4Wire or Single phase Network User can program on site the network connection as either 3 Phase 3 Wire or 4 Wire or single phase network using front panel keys. Onsite selection of Auto scroll / Fixed Screen User can set the display in auto scrolling mode or fixed screen mode using front panel keys. PAGE 1

4 digits LED display (up to 9999): 14mm ultra bright 4 digits LED display. Function keys: Using two function keys it is possible to Display various parameters in Current and Voltage DPM. These function keys are also used for programming Password, Network selection, CT/PT Primary & Secondary values, Reset min/max values, Auto ON/OFF mode selection. Screen No. storage In case of power failure, the instrument memorizes the last screen stored. For every 1 min. the instrument stores the screen no. in the non-volatile memory. Min Max storage of parameters possible The instrument stores minimum and maximum values. Every 60 sec stored values are updated. Low back depth The instrument has very low back depth (behind the panel) of less than 54mm for 96x96 and 68mm for 48x96 type DPM. Available in two different Sizes: DPM is available in two different sizes 96x96 and 48x96. EMC Compatibility Compliance to International standard IEC 61326. Interference Emission : IEC 61326-1 : 2005, Class A Interference Immunity : IEC 61326-1 : 2005 Electrostatic discharge : IEC 61000-4-2 -- 4kV/8kV contact/air. (ESD) EM Field : IEC 61000-4-3 -- 10 V/m (80 MHz to 1 GHz) 3 V/m (1.4 Ghz to 2 GHz) -- 1 V/m (2 GHz to 2.7 GHz) Burst : IEC 61000-4-4 -- 2 kv (5/50 ns, 5 khz) Surge : IEC 61000-4-5 -- 1 kvll / 2 kvln Conducted RF : IEC 61000-4-5 -- 3 V (150 khz to 80 MHZ) Rated Power Frequency magnetic Field : IEC 61000-4-8 -- 30 A/m Voltage dip : IEC 61000-4-11 -- 0% during 1 cycle. -- 40% during 10/12 cycles. -- 70% during 25/30 cycles. Short interruptions : IEC 61000-4-11 0% during 25/30 cycles. 25 cycles for 50 Hz test. 30 cycles for 60 Hz test. Enclosure Protection for dust and water: Conforms to IP 50 (for front face) or IP 65 option (for front with seal) & IP 20 (for back) & as per IEC60529. Technical Specifications Input Voltage Article No: 136-5393 & 136-5394 Digital AC Voltmeter: Nominal input voltage (AC RMS) Phase Neutral 290V L-N, Line-Line 500V L-L Max continuous input voltage 120% of rated value Nominal input voltage burden < 0.3 VA approx. per phase. System PT secondary values 100VLL to 500VLL programmable on site. System PT primary values 100VLL to 999kVLL programmable on site. Input Current Article No: 136-5390 & 136-5391 Digital AC Ammeter: Nominal input current 5A AC RMS System CT secondary values 1A & 5A programmable on site. System CT primary values From 1A up to 999kA (for 1 or 5 Amp ) Max continuous input current 120% of rated value Nominal input current burden < 0.2 VA approx. per phase Auxiliary Supply: External Aux 40 V 300V AC-DC (± 5 % ) Frequency range 45 to 65 Hz VA burden 3 VA Approx. Overload Withstand: Voltage Current 2 x rated value for 1 second, repeated 10 times at 10 second intervals 20x rated value for 1 second, repeated 5 times at 5 min intervals PAGE 2

Technical Specifications Continued Operating Measuring Ranges: Voltage Range Current Range Frequency 10 120% of rated value 10 120% of rated value 45 65 Hz Reference conditions for Accuracy: Reference temperature 23 C +/- 2 C Input waveform Sinusoidal (distortion factor 0.005) Input frequency 50 or 60 Hz ±2% Auxiliary supply voltage Rated Value ±1% Auxiliary supply frequency Rated Value ±1% Accuracy: Voltage Current Influence of Variations: Temperature coefficient : (for rated value range of use (0 50 C)) 0.05%/ C for Current Display update rate: Response time to step input ±0.5% of range + 1 Digit (10... 100% of Nominal value) ±0.5% of range + 1 Digit (10... 100% of Nominal value) 0.025%/ C for Voltage 1 sec approx. Applicable Standards: EMC IEC 61326-1: 2005 Safety IEC 61010-1-2001, Permanently connected use IP for water & dust IEC60529 Safety : Pollution degree: 2 Installation category: III High Voltage Test 3.3 kv AC, 50Hz for 1 minute between Aux. and measuring inputs Environmental: Operating temperature Storage temperature Relative humidity Warm up time Shock Vibration 0 to +50 C -25 C to +70 C 0... 90% non-condensing Minimum 3 minute 15g in 3 planes 10... 55 Hz, 0.15mm amplitude Enclosure: Front IP 50. Front with seal (Option) IP 65. Back IP 20. Dimensions and Weights: a) 96x96 DPM Bezel size 96 mm x 96 mm DIN 43 718. Panel cut-out 92 +0.8 mm x 92 + 0.8 mm. Overall depth 55 mm. Weight 310 gm. Approx. b) 48x96 DPM Bezel size 96 mm x 48 mm DIN 43 718 Panel cut-out 92 + 0.8 mm x 43.5 + 0.6 mm. Overall depth 68 mm. Weight 250 gm. Approx. PAGE 3

Connection Diagram A) For 96x96 DPM *Note: or Measurement of parameters in 136-5393 & 136-5394 DPM s Voltage must be present between terminal 2 & 11 for single phase or 3 phase 4 wire network and between terminal 2 & 5 or 2 & 8 for 3 phase 3 wire network. And for 136-5390 & 136-5391 DPM s current must be present between terminal 1 & 3 for 3 phase 4 wire or 3 phase 3 wire or single phase network. B) For 48x96 DPM *Note: For Measurement of parameters in 136-5393 & 136-5394 DPM s Voltage must be present between terminal 8 & 1 for single phase or 3 phase 4 wire network and between terminal 6 & 8 or 3 & 8 for 3 phase 3 wire network. And for 136-5390 & 136-5391 DPM s current must be present between terminal 9 & 10 for 3 phase 4 wire or 3 phase 3 wire or single phase network. PAGE 4

Installation: Easy Clip in installation on Panel for 96 x 96 size: A) For 96x96 DPM B) For 48x96 DPM PAGE 5

Ordering Information: Article No: 136-5390 48X96mm, 3 Phase (Single Phase), AC Ammeter 14mm display Input. 1 or 5 Amps AC, Voltage supply. 40-300V AC/DC auxiliary (Programmable CT primary and secondary values & Storage of MIN/MAX Values) Article No: 136-5391 96X96mm, 3 Phase (Single Phase), AC Ammeter 14mm display Input. 1 or 5 Amps AC, Voltage supply. 40-300V AC/DC auxiliary (Programmable CT primary and secondary values & Storage of MIN/MAX Values) Article No: 136-5393 48X96mm, 3 Phase (Single Phase), AC Voltmeter 14mm display Input. 100-500VLL (57.7-288V L-N), Voltage Supply. 40-300V AC/DC auxiliary (Programmable PT primary and secondary values & Storage of MIN/MAX Values) Article No: 136-5394 96X96mm, 3 Phase (Single Phase), AC Voltmeter 14mm display Input. 100-500VLL (57.7-288V L-N), Voltage Supply. 40-300V AC/DC auxiliary (Programmable PT primary and secondary values & Storage of MIN/MAX Values) Articles No: 136-5393 & 136-5394 Digital AC Voltmeter Network type Displayed Parameter 1) 3 Phase 4 wire a. Phase - Neutral Voltage R/L1 b. Phase - Neutral Voltage Y/L2 c. Phase - Neutral Voltage B/L3 d. Line-Line Voltage RY/L1-L2 e. Line-Line Voltage YB/L2-L3 f. Line-Line Voltage BR/L3-L1 g. System Voltage V h. Max. system voltage V i. Min. system voltage V 2) 3 Pahse 3 wire a. Line-Line Voltage RY/L1-L2 b. Line-Line Voltage YB/L2-L3 c. Line-Line Voltage BR/L3-L1 d. System Voltage V e. Max. system voltage V f. Min. system voltage V 3) 1 Phase 3 wire a. Phase - Neutral Voltage V b. Max. voltage V c. Min. voltage V Articles No: 136-5390 & 136-5391 Digital AC Ammeter Network type Displayed Parameter 1) 3 Phase 4 wire a. Phase Current A R/L1 and b. Phase Current A Y/L2 3 Phase 3 wire c. Phase Current A B/L3 d. System Current A e. Max. system Current A f. Min. system Current A 2) 1 Phase 2 wire a. Phase Current A b. Max Phase Current A c. Min Phase Current A PAGE 6