PERMA Series Revision 2 Amplifiers

Similar documents
THE PUBLIC ADDRESS AMPLIFIER SYSTEM WITH FLEXIBILITY BUILT-IN

FreeSpace IZA 250-LZ / 190-HZ TECHNICAL DATA SHEET. integrated zone amplifier. Key Features. Product Overview. Product Information.

MA80FT Mini Amplifier

FreeSpace IZA 2120-LZ Integrated Zone Amplifier

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

Power Supply and Protection Circuit

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual

AC/DC Power Supply Series APPLICATION NOTE

AC/DC Power Supply Series APPLICATION NOTE

Amplifiers and battery charger

PB-400-CN. Datasheet. IndustryAmp PB-400-CN * Applies to Part Number: *This unit has a CobraNet interface installed

PA0688 Microphone Pre-Amplifier Module

Boulder W Class A Stereo Power Amplifier

AC/DC Power Supply Series APPLICATION NOTE

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

UP-67M4, UP-127M4, UP-247M2, UP-487

TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

SPECIFICATION EP 1000/1500/2000 Series

USER MANUAL QSM-606AZ QSM-612AZ QSM-624AZ MIXER AMPLIFIER

SR3400 Base Station Module Configuration and Use Series-2 Cards Only

3050 Stereo Power Amplifier

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series

Z4MK3/Z8MK3 : Zone Mixers

Owner s Manual B 300 B 600 B 900 B 1200 B 1500 B 902 B 1202 B 1802 B300 B1802

DNA Pro series 10K8 3K8

SM2000 TECHNICAL DESCRIPTION

MASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2. Maintenance Manual LBI-30766L. Mobile Communications

AUTOMATIC MIXER AX-1OOOA

VPA PUBLIC ADDRESS AMPLIFIERS

Green LED (right of 'D' type connector)

Bosch Communications Systems Get your message across, effectively.

audionet AMP 1 V2 User s Manual Stereo - Amplifier

Model 7000 Low Noise Differential Preamplifier

DECLARATION OF CONFORMITY

TOA 500 SERIES MIXER POWER AMPLIFIER

Q-Tech Commercial Series. 86 Derby St. Pascoe Vale VIC 3055 ( : *

Thornwood Drive Operating Manual: Two-SCR General Purpose Gate Firing Board FCRO2100 Revision H

MA40E Mini Amplifier with DSP

MC450/MC650 (MC750) OPERATING INSTRUCTIONS

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

DLVP A OPERATOR S MANUAL

MAINTENANCE MANUAL AUDIO MATRIX BOARD P29/

TOA PROFESSIONAL POWER AMP

Boulder W Mono Power Amplifier

DC-DC Converter Module

1160 Stereo Power Amplifier

IRT Eurocard. Type AG-738. Stereo Audio Phase / Failure Detector

VX-3000 Series Voice Alarm and Public Address System

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

Q-Tech. Q-Tech Commercial Series QTA 1360P/1480P Power Amplifiers. User Manual

FreeSpace ZA 250-LZ / 190-HZ zone amplifier TECHNICAL DATA SHEET. Key Features. Product Overview. Product Information.

Operating Manual IMPORTANT NOTE: A Watt Mixer Amplifier. Redback Proudly Made In Australia

AC/DC Power Supply Series APPLICATION NOTE

ICEpower125ASX2 Designer s Manual 2x125W or 1x500W ICEpower Amplifier with integrated ICEpower Supply

PROFESSIONAL POWER AMP

ST-250MAK-05E. Switching Power Supply SPECIFICATION

TOSHIBA International Corp

Power Supply Unit (550W)

Technical data sheet 1671 Power amplifier Art. no 19611

Datasheet. IndustryAmp PB-800-CN * Applies to Part Number: *This unit has a CobraNet interface installed

10. High Boost HAM. Maxi, Mini, Micro Design Guide Rev 4.9 vicorpower.com

MC2301. Features and Benefits. Promotional Highlights TUBE POWER AMPLIFIER MCINTOSH LABORATORY INC., 2 CHAMBERS STREET, BINGHAMTON, NEW YORK 13903

8101 SPECIFICATION SHEET

IRT Eurocard. Type DDA Mbits/s Data Distribution Amplifier. Telstra Serial Item Numbers 347/93 DDA /94 Operations Manual - DDA-3100

DENISON HYDRAULICS Proportional Pressure Control Valves

MA6480A. Energy-Efficient, Multi-Function 240-Watt Mixing Amplifier with Dual 70/100 V and 4 Ohms Outputs. Features

Professional Stereo Amplifiers

VEB Series. TCP/IP Network Matrix PA System. 32 simultaneous Audio Buses. Up to 60 Network Paging Consoles. Up to 128 Audio Output channels

MODEL AF200A: FM, FM/SCA RECEIVER/MONITOR OPERATION MANUAL

SPECIFICATION. SilverStone OLYMPIA OP1000 Switching Power Supply Active PFC

LBI-31807D. Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1. Maintenance Manual. Printed in U.S.A.

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

FreeSpace ZA 250-LZ / 190-HZ zone amplifier TECHNICAL DATA SHEET. Key Features. Product Overview. Product Information.

SPA2060, SPA2120, SPA2240 amplifier. User Manual

UMA 4300 Professional Series Installation Power Amplifer Owner s Manual

PLENA SOLUTIONS F E A T U R E S PUBLIC ADDRESS GUIDE

User Manual. MA 21 Two zone mixing amplifier

SC1000 DGPS USCG Dual Transmitter

Kattegat JP Groningen, The Netherlands High Efficiency High Power Audio SMPS

... yet still led out of the terminal quickly and safely in an emergency.

PLUG N PLAY WATT DIGITAL FM TRANSMITTER. April, 2002 IM No

TOA 900 SERIES POWER AMPLIFIER P-924A

Current Draw (Circuit breakers and fuses blow. Burning smell or smoke)

10. High-Boost HAM. Design Guide & Applications Manual. Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies

MODEL , MODEL 310SAO, AND MODEL 310-ALT

The Micromega MyAMP. A serious design challenge

COM-POWER OPERATION MANUAL ACS W

Product Specification

MPU 2120 MPU Monoblock unit 60W to 480W Same features as the MPU 2120 model except for the following difference: Configurations: 4x60W, 2x120W

bhi bhi DSP Noise Cancelling Products DSP Noise Cancelling Products NEDSP1061-PCB bhi ltd PO Box 318 Burgess Hill West Sussex RH15 9NR

TC-600PD2. Switching Power Supply ( 600W PS2 ATX12V ) SPECIFICATION. Revision: 1.0

PS 19 AM SINGLE CHANNEL BELTPACK IN METAL CASE WITH PGM (AUX) INPUT

DPA602 1/7. Multi-Channel Network Amplifier. General Description. Features. Applications. AtlasIED.com. DPA602 Front. DPA602 Back

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

OWNER S MANUAL CPS 1 / CPS 2 CONTRACTOR PRECISION SERIES

Model 3102D 0-2 kv H.V. Power Supply

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements.

Lynx. RoIP Gateway DISPATCH LYNX MOBILE. Optional serial ports provide remote control of radio configuration over the VoIP network.

3 Circuit Theory. 3.2 Balanced Gain Stage (BGS) Input to the amplifier is balanced. The shield is isolated

Transcription:

PERMA Series Revision 2 Amplifiers High Efficiency Life Safety Digital Power Amplifiers Current Thinking Document Number DDC PER 7001 02 ACS

Introduction Voice Alarm (VA) systems are the quickest way to evacuate the public & staff from a building. Following fire detection, automated messages control the flow of people in stairwells and corridors allowing an orderly evacuation without panic. These messages are supplemented by spoken messages from the fire service or management suite confirming the validity and need to leave the building. This positive confirmation speeds evacuation and avoids the "false alarm" mentality reducing the risk of death from fire. The PERMA series of amplifiers form a vital part of a VA system, and due to unique features they are suitable for all sizes and complexities of VA system. Amplifier Overview Each PERMA amplifier contains two independent high efficiency power amplifiers, each with load monitoring (both AC and DC), earth fault monitoring, and tone fail monitoring, and a 24VDC battery supply input with onboard monitored battery charger. Routing logic allows amplifier modules to operate independently, with each amplifier having a main and auxiliary input, which mix or, if the PTT contact is operated, the main overrides the auxiliary. The routing logic also allows the amplifier to operate as an AB amplifier, where both channels receive the same signal (this also allows the outputs to be paralleled for higher power operation). In this case the slave output allows the priority audio signal to be routed directly to the slave connector, and faults and swap information cascade Each amplifier s current fault status is displayed on the front panel along with an output bar graph and matrix access status. All indicators are in accordance with EN60849. The unit is supplied in a 2U 19 DIN standard rack mount chassis. All sections of the amplifier and charger are constantly monitored for faults or abnormal operation. The load monitoring either checks the DC PERMA Series Amplifiers Page 2 2002 Current Thinking Ltd

resistance of the speaker lines, or checks the power absorbed by the speaker load and end of line units (EOLs) and compares this with the value set at installation. If the power draw deviates outside a pre defined window of 10% a fault is indicated on the unit and signalled to other equipment via the relevant fault outputs. If the surveillance monitoring tone is not being received by the amplifier, the Tone Fail light shows for the relevant channel. Should either leg of the speaker wiring short to system earth this will also light the Earth Fault LED, this system will also spot earth faults on the secondary of speaker transformers. Mains power status is monitored, along with the internal fuses, standby batteries and battery charger to give a complete picture of the state of the amplifier. The output from each module is presented on a three-way LVD compliant socket and is fully floating. The standard output voltage is 100V, allowing two modules to be connected in parallel to give up to 400W at 100V line using the PERMA4 amplifier. Standards Compliance The @udio Logistics PERMA series amplifiers complies with all the current Voice Alarm standards including BS5839 parts 1 & 8 and EN60849. We are also monitoring the meetings of the EN54-16 committee to ensure we will comply when this is released. Additionally the PERMA series comply with the EMC requirements of EN55103-1 and EN55103-2 as well as the LVD requirements of EN60065 and EN61000-3-2. PERMA Series Amplifiers Page 3 2002 Current Thinking Ltd

Detailed technical description The two audio signals enter the amplifier module through RJ45 type connectors, from which they pass through an input preamplifier, which debalances them and allows the audio level to be set with rear mount potentiometers. The audio then passes to an analogue switch array, which gates the audio depending on the setting of the PTT access voltage. Amplifier Modules The two amplifier modules are identical. The two audio signals enter the amplifier module through RJ45 type connectors, from which they pass through an input preamplifier, which debalances them and allows the audio level to be set with rear mount potentiometers. The audio then passes to an analogue switch, which gates the audio depending on the setting of the PTT access voltage. The signal output from the matrix then passes through to the output stage, which consists of two identical PSCPWM half bridges, each driven with an error signal 180 o out of phase with the other. This phase shift has the effect of doubling the effective sampling frequency of the modulators; this reduces the filtering requirement on the amplifier output, whilst lowering the switching losses in each of the bridges all of which increase the efficiency of the amplifier. Each PSCPWM bridge has cycle by cycle current limiting, which reduces the power dissipation when the amplifier is driving a difficult load, or the output is short circuited, this limiting is fully automatic, and resets as soon as the fault is removed. A protection circuit shuts down the output stage when the voltage rails in the amplifier fall below 22V or exceed 36Volts, or when a DC offset is present on the output rails (due to component failure). PERMA Series Amplifiers Page 4 2002 Current Thinking Ltd

The output of the transformer boosts the audio level to 100 Volt line level, and amplifiers channels can be connected in parallel to provide up to 400 Watts at 100 V line on a PERMA4 amplifier. Power Supply Mains enters via the mains inlet, passes through the power switch, EMC filter and inrush suppression circuits and is transformed and rectified. A large low ESR capacitor bank provides a very smooth output, even under large current surges which is necessary for class D amplifiers which have a low PSVRR (Power Supply Voltage Ripple Rejection) compared to class AB amplifiers. Two separate filtered 15 Amp fused outputs connect to the two amplifier modules (one feed per amplifier channel). Another feed passes, via the aux. on LED (this shows that the aux. power is available on the rear connector) through a 3 Amp fuse to the aux. power connector this is used to power. A 27.6 Volt variable impedance regulator with a 3 amp current limit is also driven from the supply, allowing the connection of external vent regulated sealed lead acid (VRSLA) batteries via a 25 Amp fuse. This charger is switched off for 10mS every time the mains AC waveform passes through zero, to enable the charge in the batteries to be determined. The battery chargers in several amplifiers can be paralleled for large capacity batteries, however the amplifiers must be driven from the same mains phase for the monitoring to work. Batteries for the amplifier must be connected in series, as the battery monitoring circuit cannot detect faulty cells in paralleled battery banks. Normally the amplifier would be connected to two series 12V nominal batteries, however for higher capacities it may be necessary to series four 6V nominal batteries. The battery monitoring circuit cannot detect faulty cells in paralleled battery banks The power supply is fully monitored for battery health and fuse integrity. PERMA Series Amplifiers Page 5 2002 Current Thinking Ltd

Fault Monitoring The PERMA Series amplifiers contain two methods of load monitoring, depending on the setting of the DIP Switches on the rear of each amplifier module, AC monitoring and DC monitoring. AC Line Monitoring: To monitor the amplifier and loudspeaker system, two parameters are measured, the output voltage and current. These signals then pass through fourth order band pass filters @ 22.05 khz, the rectified log of these ac signals is then taken, and the signals are summed. This gives a voltage, which represents the true load power (I*V) at 22.05 KHz. This value is passed to a detector, which compares the measured power value with that set at commissioning, generating load HI or LO faults if necessary. The monitoring tone is injected into the incoming audio input from the previous device in the chain, allowing the full audio path to be monitored. The detector also indicates the absence of the monitoring tone and signals this to the tone fail LED. The detector circuit also tracks small changes in impedance over time to prevent faults being detected due to cable impedance changing with temperature or ageing of speaker transformers. Because the monitoring tone is crystal controlled, and the detect circuit is so accurate, it is possible to accurately determine load faults without false faults being generated. This allows most speaker circuits to be cabled as spurs provided each spur s wattage exceeds 25 Watts or has an end of line unit fitted. DC Line monitoring: Because of the wide specification of high capacitance cables such as MICC we have equipped the PERMA series amplifiers with DC line monitoring, this requires that each speaker be fitted with a DC blocking capacitor (typically 2.2uF 400V non polar on a 6W ceiling speaker), which are available from most speaker manufacturers. The amplifier looks for a 9K end of line load, and this allows the speaker circuits to be operated as spurs, typical supplied end of line resistors are 2 number 18K 1W power PERMA Series Amplifiers Page 6 2002 Current Thinking Ltd

resistors, however you can also use up to 6 spurs, each fitted with a 56K ¼ W resistors. Earth Fault Monitoring: A detector circuit connected to the output transformer monitors the current flowing through the load, any imbalance in this normally floating output must be due to a short or low impedance leak to system earth generating an earth fault and lighting the EARTH LED on the front panel. The load high, load low, earth fault and tone fail outputs for each amplifier are brought out separately on the Fault port. A common fault output is also provided which is triggered by any fault on the amplifier. PERMA Series Amplifiers Page 7 2002 Current Thinking Ltd

Front Panel Indication Module Indication Both amplifier modules are identical in operation, and the operation of the A module will be described only: Peak: Signal: This LED lights when the output voltage on the 100V line terminals exceeds 90V. This LED lights when the output voltage on the 100V line terminals exceeds 4V. Priority: This LED lights when a priority PTT voltage is present on the Priority audio input for this module. Page: On: This LED lights when a page PTT voltage is present on the Page audio input for this module, or INPUT OPTION switch 3 is set to ON (Access Page Port) This LED lights when the module has all supply rails available Protect: This LED lights when the module has detected an internal fault, including over temperature, oscillator failure, over current (output shorted) or under voltage. When the amplifier is turned on this led will illuminate for approximately 3 seconds as the module stabilises. Load: Swap: This LED lights when a load fault has been detected, depending on the settings of the load monitor dip switch for this module (see later) This LED lights when a priority is operated on the module and either a tone fail or protect condition exists, signalling that a reserve amplifier is required in automatic Hot Swap systems. PERMA Series Amplifiers Page 8 2002 Current Thinking Ltd

Supply Indications Mains: Battery: Fuse: PSU Fault: OK: This LED lights when AC mains is present to the amplifier This LED lights when the DC reserve battery supply is present. This LED lights when either the mains or battery fuses have failed (or these supplies have been removed). This LED signifies that a supply rail to the amplifier modules has failed or the battery charger has failed. This blue LED is illuminated if the amplifier is free of monitored faults. Rear Panel Indication and Settings Both amplifier modules are identical in operation, and the operation of the A module will be described only. Each module has 2 sets of DIP Switches (monitor options Vertically to the left, and Input Options horizontally toward the middle of the module), 5 LEDs associated with the monitoring section (as well as a set pot and push switch). First we shall describe the audio inputs and outputs, and associated input switch options; followed by the monitoring section. PERMA Series Amplifiers Page 9 2002 Current Thinking Ltd

Connections Audio Inputs Normally the amplifier will be housed in a rack with the control equipment, when connection is simply by using a LSF (low smoke & fume) CAT5 patch lead. The PERMA amplifiers have 2 audio inputs per amplifier Module, Main & Priority. However if the amplifier is remote from the rack recommended cabling for the field Amplifiers is 1 number 1.5mm 2 four core FP200 type soft skin cable for runs up-to 1KM, alternatively 1 number 4 core 1.5mm 2 MICC type cable can also be used, up-to a maximum distance of 200M Audio input Connection Details 1 +24V DC 2 GND* 3 PTT 4 NC 5 NC 6 NC 7 Audio +Phase 8 Audio -Phase *see text below for Priority port Signal Descriptions Pins 2 & 3, provide a two-way handshake between the amplifier and control equipment, the amplifier monitors the voltage on the line, and normally presents 2V if the amplifier is healthy. Pin 1 provides a power supply for microphones or message stores on simple systems. Pin 2 on the priority port can be earth lifted to remove hum loops in larger systems, when lifted the pin is referenced to earth with a 1N EMC capacitor and a 10K pull down resistor- this option should be disabled by setting INPUT OPTION switch 4 ON when using microphones or message stores powered from this input. PERMA Series Amplifiers Page 10 2002 Current Thinking Ltd

Audio comes from the control equipment via pins 7 & 8, this audio pair also indicates the operational status of the control equipment by applying an 8V phantom voltage to the lines to indicate integrity of field wiring. Operation The Control equipment raises the PTT line voltage to 5V to indicate that it wishes to use the audio input for priority paging. This sense voltage can be used to trigger external devices such as volume over ride relays or activating page only areas. The page input can be set to permanently access the amplifier for music inputs by selecting INPUT OPTION switch 3 to ON If the control equipment fails to see the 2V on the PTT line, and the output monitor option is set, the Control equipment will signal a fault and places an entry into its fault log. Power supply faults can be signalled back to the control equipment by selecting INPUT OPTION switch 1 to ON PERMA Series Amplifiers Page 11 2002 Current Thinking Ltd

SLAVE Port The slave port has two main functions, the primary function is to cascade amplifier priority inputs for multiple amplifiers serving a zone, or where you have the priority port supplying VA programme material, and the page port used for multi-zone PA applications. The secondary function of the Slave port is to provide audio out and handshaking for the hot swap amplifier controller, allowing automatic substitution of a serving amplifier in fault. Slave Port Connection Details 1 +24V DC 2 GND 3 PTT OUT 4 SWAP 5 Fault in 6 NC 7 Priority Audio +Phase 8 Priority Audio -Phase Operation When the priority signal is detected by the priority input of this module, the slave PTT out acts in sympathy, accessing the priority input of the next amplifier in the chain, similarly the fault in line expects to be held low by the cascaded amplifier unless INPUT OPTION switch 2 is set to ON, in which case slave faults are ignored. When the amplifier module detects a fault which has stopped it operating it will open circuit the SWAP line, and light the front panel SWAP LED signalling to a hot swap controller it wants substitution. PERMA Series Amplifiers Page 12 2002 Current Thinking Ltd

100V Line Output Connections The recommended cabling for the field speakers with no restoration is 1 number 1.5mm 2 two core FP200 type soft skin cable for runs up-to 500M, or 1 number 2.5mm 2 two core FP200 type soft skin cable for runs up-to 1KM, alternatively 1 number 2 core 1.5mm 2 MICC type cable can also be used, up-to a maximum distance of 200M The cabling for the field speakers with three wire volume restoration is 1 number 1.5mm 2 four core FP200 type soft skin cable for runs up-to 500M, or 1 number 2.5mm 2 four core FP200 type soft skin cable for runs up-to 1KM, alternatively 1 number four core 1.5mm 2 MICC type cable can also be used, up-to a maximum distance of 200M 100V Line Output Connections 1 100V line output 2 Electrical Earth (screen) 3 0V return Signal Descriptions Pins 1 and 3 are high voltage terminals, which are designed to connect to 100V line speaker distribution circuits. Operation In normal mains powered operation, the amplifier provides a voltage proportional to the audio present at the selected input. The output is fully protected against short circuits and earth faults. PERMA Series Amplifiers Page 13 2002 Current Thinking Ltd

Battery Connection The recommended cabling for the batteries are two number 4mm CSA LSF cables within a rack, we recommend fusing the batteries separately for each amplifier with a 20A HRC cartridge type fuse. The feeds to several amplifiers should always be run separately to ensure the best audio separation between amplifier channels. Battery Connection Details 1 2 1 GND 2 +27V6 maintained connection to battery Signal Descriptions Pins 1 & 2, are high current (49A) terminals which are designed to connect to SLA batteries. Operation In normal mains powered operation, the amplifier provides a charging voltage of 27V6 at 3A from a variable impedance charging circuit to maintain valve regulated sealed lead acid batteries (VRSLA). Multiple amplifiers can be connected to the same batteries as long as the amplifiers are driven from the same mains phase. Batteries must be connected in series; the battery monitoring circuit cannot detect faulty cells in parallel battery packs. PERMA Series Amplifiers Page 14 2002 Current Thinking Ltd

Load Monitoring Each amplifier module has independent load monitoring, selectable as AC or DC mode depending on application and the settings of the monitor option DIP Switches: 1: DC Short Monitor 2: AC Open Monitor 3: Earth Fault Monitor 4: Tone Fail (AC Short) DC SHORT Circuit Monitor (option 1), setting this switch to On will report a fault (light the Load Short LED) whenever the DC resistance of the 100V line speaker terminals falls below 5K ohms. AC Open Circuit Monitor (option 2), setting this switch to On will light the Load Open LED when the set monitoring tone is 10% above the level set on the Set Monitor Pot. Earth Fault Monitor (option 3), setting this switch to On will light the earth fault LED when either leg of the 100V line circuit is less than 20K to earth (AC or DC leakage) Tone Fail Monitor (option 4), setting this switch to On will light the TONE Fail LED when the 22KHz pilot tone level drops 10% below the level set on the Set Monitor pot Setting the Load Monitoring DC Load Monitoring: Ensure all speakers have DC blocking capacitors fitted, and the end of line 9K resistor (2 off 18K in parallel or 6 off 56K in parallel) is fitted on the circuit end, then set switch 1 and 3 to on (2 and 4 off)- set up is automatic if the EOL resistor is missing, or the line is shorted (or <5K DC resistance) the relevant LED will light AC Load Monitoring: Ensure the AC end of line device is fitted for complete EOL detection; otherwise the monitoring will detect a change of 10% only. Set options 2,3 and 4 to on (1 off). Set up- Press the set monitor push button in (this reduces the detection window to 1%) and turn the set monitor pot until the Tone fail and load open LEDs go out (the OK LED should light), the push button can now be released, opening the window to 10%. The LEDs on the rear light on any momentary fault, however using a digital filter in the amplifier the fault has to exist for 5 seconds before the fault is transmitted to the front panel and any controller reducing false indications Stand by Amplifier Monitoring: This checks the amplifier is amplifying the monitor tone when used as a Hot Standby amplifier; Set switch 4 on, (1,2 and 3 off) and turn the Set Monitor pot until the tone fail LED goes out. PERMA Series Amplifiers Page 15 2002 Current Thinking Ltd

Amplifier Performance Specification Output power 200W RMS (PERMA 4) 100W RMS (PERMA 2) Frequency Response 50Hz to 25kHz -3dB +0dB THD better than 0.1%, 1kHz SINAD better than -80dB Regulation better than 1dB Output voltage 100V line (50 & 70.7V available to special order) Operational mode Bi phase PSCPWM Efficiency >92% PERMA2 >86% PERMA4 Protection Over voltage, under voltage, DC offset, short circuit, thermal and safe operating area Standby current 150mA with fault lights lit and full load monitoring per module Full load current 11A (PERMA4) 6A (PERMA 2) @27V Monitoring Detection frequency Detection type 22.05kHz AC Window comparator system DC Resistive Bridge option (10K open circuit 5K Short Circuit AC Window 10% Sensitivity -40dB to -10dB, user adjustable Power supply & charger AC input 230 VAC +/- 20% DC input 22 to 34 VDC Charging voltage 27.6 VDC Charging current 3A Monitoring Short circuit and battery high impedance Aux supply 1A Fault Port Isolated faults for signalling to other equipment Dimensions Width Height Depth Weight 433mm 88mm 300mm 14Kgs PERMA Series Amplifiers Page 16 2002 Current Thinking Ltd