ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx

Similar documents
Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

PARTNER ALTERNATORS LSA Pole

PARTNER ALTERNATORS LSA 40-4 Pole

LSA Pole. R 726 Mains paralleling

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

Low Voltage alternators - 4 pole LSA 47.2

TAL 049 Low Voltage Alternator - 4 pole

TAL 047 Low Voltage Alternator - 4 pole

WDG 71 - Technical Data Sheet

WDG 07 - Technical Data Sheet

TAL 044 Low Voltage Alternator - 4 pole

WDG 12 - Technical Data Sheet

Low Voltage alternators - 4 pole LSA 46.2

WDG 13 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 61 - Technical Data Sheet

WDG 51 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 83 - Technical Data Sheet

S0L1-J1 - Technical Data Sheet

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

S4L1S-D4 Wdg.17 - Technical Data Sheet

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

S4L1D-G41 Wdg Technical Data Sheet

PI734C - Technical Data Sheet

PI734A - Technical Data Sheet

440 (12) 416 (12) 416 (12) 440 (12)

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PM734B - Technical Data Sheet. Generator Solutions AS

Spec Information. Reactances Per Unit Ohms

GENERATOR DATA JANUARY 30, 2015

Spec Information. Reactances Per Unit Ohms

AGN 034 Alternator Reactance

Technical Data Sheet for AvK-Alternators

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

Technical Data Sheet for AvK-Alternators

Technical Data Sheet for AvK-Alternators

Technical Data Sheet for AvK-Alternators

Generator Advanced Concepts

Generation Interconnection Study Data Sheet Synchronous Machines

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

Packaged Generators: New Kato Engineering Packaged Generator Line: Over 75 Years of Experience: Conformity: Service: Quality Standards:

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

4939 en / a PARTNER ALTERNATORS LSA 54. General features and ratings

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

Impact Assessment Generator Form

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

SYNCHRONOUS MACHINES

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW

4938 en / a PARTNER ALTERNATORS LSA General features and rating4

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

AGN 005 Fault Currents and Short Circuit Decrement Curves

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

APPENDIX B: Generation Interconnection Application Form

Sizing Generators for Leading Power Factor

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

Motor Protection. May 31, Tom Ernst GE Grid Solutions

PART 1 OWNER/APPLICANT INFORMATION

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Connection Impact Assessment Application Form

Connection Impact Assessment Application

Application Guidance Notes: Technical Information from Cummins Generator Technologies

SAMSUNG ELECTRO-MECHANICS CO., LTD

TABLE OF CONTENT

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

Orbital GFI Inverter Series

Low Voltage Alternators - 4 pole

Contents. About the Authors. Abbreviations and Symbols

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

STEADY STATE REACTANCE

HCM634G - Technical Data Sheet

Overview of IAL Software Programs for the Calculation of Electrical Drive Systems

POWER QUALITY REPORT

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

Owner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:

AGN 124 AVR Power Supplies

Servomotors Order Catalogue. LSN - Servomotors with stall torque 0.26 to 60 Nm

EC centrifugal fan - RadiCal

R448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

Objective: Study of self-excitation characteristics of an induction machine.

R448 & R448 V50 A.V.R.

TETRA COMPACT LOW VOLTAGE BRUSHLESS SERVOMOTORS

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

Application Guidance Notes: Technical Information from Cummins Generator Technologies

Conventional Paper-II-2013

Automatic capacitor banks with detuned filters

Transcription:

ALTERNATOR TECHNICAL DESCRIPTION LSA 53.2 XL3 / 4p LS Reference: 3_66 Date: 426 V4.5G 9/26 Chargé d'affaire : Karthikeyan GN Moteurs LeroySomer +33 ()2 38 6 42 xx Electric Power Generation Orleans prenom.nom@leroysomer.com rue de la Burelle 458 Saint Jean de Braye France Unknown Main data EXT C Generator type: LSA 53.2 XL3 / 4p Power: 3 kva 2 4 kwe 2 483 kwm Voltage: 66 V Star serial Rated voltage range: +5/5% Power factor Lagging:,8 Frequency: 5 Hz Speed: 5 rpm Nominal current: 262 A Winding type: p5/6 Classes (Insulation / Temperature Rise): H / F Ambient Temperature: 4 C Altitude: m Installation Quantity Prime mover: Reciprocating engine Manufacturer: Type: Duty: Base Rating Mechanical Construction IM Type of construction: Two bearing Mounting arrangement: Horizontal Axis Direction of rotation: Clockwise (seen when facing the drive end D) Bearing type: Antifriction Bearing Lubrication: Regreasable Bearing insulation: Not insulated Shaft end type: Cylindrical with keyway Balancing Class (ISO 94/): Half key G2,5 (std) Flange: None / without Shaft height: 5 mm Width: 5 mm Additional specificities Stabilized Runaway speed: rpm 2 min. Cooling Method IC Degree of protection: IP23 Coolant: Air / Temperature: 4 C Air quality: Clean Ventilation (internal): Selfventilated Filters: Without Ducting for air inlet: No Ducting for air outlet: No 3_66 rev. Page / 7

ALTERNATOR TECHNICAL DESCRIPTION LSA 53.2 XL3 / 4p LS Reference: 3_66 Date: 426 V4.5G 9/26 Chargé d'affaire : Karthikeyan GN Connection, Excitation & Regulation Parallel operation: Between alternators (F) Excitation: Selfexcited Brushless Type: AREP + PMI Sustained 3phase Isc: > 3 x FLC for s. AVR type: D5C Digital AVR location: In terminal box Alternator Voltage sensing: Terminal box mounted voltage sensing VTs Additional features: Threephase sensing Terminal box Power connection: 6 connectors (3 neutrals brought out) Main Terminal box location: On Top Line side outlet: Refer to comments Gland plate: Non magnetic Comments: 3 Phase cable on RHS & 3 neutral cables on LHS from NDE side Protection and measurement accessories Temperature detection Stator windings: 6 x 3wire Pt RTDs Combined guide and thust bearing: x 3wire Pt RTD Guide bearing: x 3wire Pt RTD Anticondensation heating Voltage: 23 V Ph / Power: 5 W Various items Paint: PE Primary RAL 732 Documentation: PDF manual Documentation Language: English Controls QUAL/INES/6 Measurement of winding resistance QUAL/INES/6 2 Insulation check on sensors (when fitted) QUAL/INES/6 2 Voltage balance and phase order check QUAL/INES/6 7 Overspeed test (according to test bench limitation) QUAL/INES/6 9 High potential test QUAL/INES/6 Insulation resistance measurement 3_66 rev. Page 2 / 7

ALTERNATOR ELECTRICAL DATA LSA 53.2 XL3 / 4P LS Reference: 3_66 C V4.5G 9/26 Main data: Power: 3 kva 2 4 kwe 2 483 kwm Voltage: 66 V Frequency: 5 Hz Rated voltage range: +5% / 5% Speed: 5 rpm Power factor Lagging:,8 Nominal current: 262 A Phases 3 Insulation / Temperature rise: H / F Connexion Star serial Cooling: IC Winding type: p5/6 Winding : 6 Wires Ambient Temperature: 4 C Altitude: m Overspeed (rpm) 8 Duty: Base Rating Total Harmonic Distortion (THD) < 5% Efficiency ( Base 3 kva ) IEC 25% 5% 75% % % Power factor Lagging:,8 94,3 96,3 96,7 96,7 96,6 Power factor Lagging: 94,7 96,8 97,4 97,5 97,5 Reactances (%) ( Base 3 kva ) Unsaturated Saturated Unsaturated Saturated Direct axis Quadrature axis Synchronous reactance Xd 25 26 Xq 28 Transient reactance X'd 25,7 2,9 X'q 28 Subtransient reactance X"d 3,9,8 X''q 4,6 2,4 Negative sequence reactance X2 4,3 2, X 9,8 Zero sequence reactance Xl 7, Stator leakage reactance Xr 2,4 Rotor leakage reactance Kcc,46 Shortcircuit ratio Time constants (s) Direct axis Quadrature axis Open circuit transient time constant T'do 3,28 T'qo NA Shortcircuit transient time constant T'd,337 T'q NA Open circuit subtransient time constant T''do,37 T''qo,57 Subtransient time constant T"d,2 T"q,8 Ta,4 Armature time constant Resistances (%) Ra, Armature resistance R 3,3 Zero sequence resistance X/R,7 X/R ratio (without unit) R2 2,9 Negative sequence resistance Voltage accuracy:,25% Maximum inrush current for a voltage dip of 5%: 2285 kva when starting an AC motor having a starting power factor between and.4 According to: I.E.C. 634. 634.2 NEMA MG 32 Products and materials shown in this catalogue may, at any time, be modified in order to follow the latest technological developments, improve the design or change conditions of utilization 826 3_66 rev. Page 3 / 7

Efficiency Rendement en % ALTERNATOR MAIN CURVES LSA 53.2 XL3 / 4P LS Reference: 3_66 Date : 826 3kVA 66V 5 Hz V4.5G 9/26 Capability Curve Umax + 5% 6 93 V Un 6 6 V Umin 5% 6 27 V PF,7 PF,8 PF,9 PF.95 kwe / rated kva PF.95 PF,9 PF,8.8 PF,7 PF,6,8 PF,6 PF,5,6 PF,5 PF,4,4 PF,4 PF,3 PF,3 PF,2,2 PF,2 PF, PF,,8,6,4,2,2,4,6,8 kvar / rated kva Efficiency Curves According to: IEC 98, 97,5 PF PF,8 97,4 97,5 97,5 97, 96,8 96,5 96, 96,3 96,7 96,7 96,6 95,5 95, 94,7 94,5 94,3 94,,25,5,75,25 Load (% of rated kwe) Charge (% kwe nominaux) 3_66 rev. Page 4 / 7

short circuit at generator terminals short circuit at generator terminals court circuit aux bornes de l'alternateur ALTERNATOR MAIN CURVES LSA 53.2 XL3 / 4P LS Reference: 3_66 Date : 826 3kVA 66V 5 Hz V4.5G 9/26 Stator Current decrement curves Symmetrical phase to neutral shortcircuit initial 2 32 A 8,8 x In Symmetrical two phase shortcircuit max 87 A 7, x In In = 262 A Symmetrical three phase shortcircuit value 2 6 A 8,2 x In Thermal Limit Isc ( Short circuit current per rated current courant de court circuit / In ) 2 Symetrical Phase to neutral short circuit Symetrical two phase short circuit Symetrical three phase short circuit Thermal limit curve 8 6 4 2,,, Time Temps (second.) Asymmetrical three phase shortcircuit IP 5 94 A 9,8 x In Isc ( Short circuit current per rated current courant de court circuit / In ) 25 2 Symetrical three phase short circuit (rms) Asymetrical three phase short circuit (peak) Thermal limit curve 5 5,,, Time Temps (second.) 3_66 rev. Page 5 / 7

Voltage rise Surtension (% of rated voltage) Voltage dip Chute de Tension (% of rated voltage) ALTERNATOR MAIN CURVES LSA 53.2 XL3 / 4P LS Reference: 3_66 Date : 826 3kVA 66V 5 Hz V4.5G 9/26 Transient Voltage Variation Transient voltage dip curve versus load impact % 5% % 5% 2% 25% 3% 35% 4% 45% Load inrush Appel de charge per rated kva,5,5 2 2,5 PF = PF =,6 PF =,8 Transient voltage rise curve versus load rejection 5% kva shedding at P.F. Delestage de charge per rated kva 45% 4% 35% 3% 25% 2% 5% % 5% %,5,5 2 2,5 PF =,8 3_66 rev. Page 6 / 7

ALTERNATOR MAIN CURVES LSA 53.2 XL3 / 4P LS Reference: 3_66 Date : 826 3kVA 66V 5 Hz V4.5G 9/26 Thermal Damage Curve 3 Stator current (per rated current) 2,5 2,5 Maximum duration durée maximum (second.) Unbalance Load Curve Stator Earth Fault Current 3 Negative phase sequence Current courant inverse (per rated current) 75 Fault Current Courant de défaut (A) C : Extensive damage B : Considerable damage A : Acceptable damage 2 5 C 25 B A Maximum duration of fault durée max. du defaut (second.) 2 3 4 5 6 7 8 9 2 Maximum duration of fault durée max. du defaut (second.) 3_66 rev. Page 7 / 7