IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Similar documents
CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

CERTIFICATE OF COMPLIANCE

Fisher LCP100 Local Control Panel

Thie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class:

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro-Pneumatic Transducers

Power supply. Calibration. Surface finishing. Seal. Process connection

Range Spring, Bias Spring, and Spring Retainer/ Spacer Selection for Fisher 3570 Pneumatic Valve Positioners

IP26 Series Current to Pneumatic Converter

Product manual wire programmable RTD transmitter

Fisher 4200 Series Electronic Position Transmitters

Intrinsic Safety Control Drawing

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

JM Enclosure Dimensions (in mm)

EJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual. Contents 1. Introduction. 3. Installation. 5.

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

DPharp Differential Pressure and Pressure Transmitters

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

Certificate of Compliance

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

Title: INTRINSIC SAFETY MADE EASY

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter

User s Manual. Manual Change No V-E. Please use the attached sheets for the pages listed below in IM 01F06F00-01EN (7th).

EN Series Installation Manual

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

Binary Output Series 9175

ORIGINAL SIZE SYSTEM CONTROL DWG. FILE. ROSEMOUNT 2410 OrCADl. o o

ATEX Installation Drawings and Instructions

Operating Manual. isolate501

Ex instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,

Product Manual wire HART transmitter

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

IECEx Certificate of Conformity Annexe

White Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD

Binary Output without Power Supply Series 9176

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Certificate of Conformity

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Emerson (Appleton Group ATX)

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

YVP110 Advanced Valve Positioner

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

ESSENTIAL INSTRUCTIONS Read this page before proceeding!

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Certificate of Compliance

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

Ex instruction manual. Rotamass Coriolis mass flow meter ATEX. IM 01U10X01-00EN-R_002, 2nd edition,

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Product Manual wire HART transmitter

COMMUNICATION NETWORKS

QN5O, QXBO, QNBO, QX7O, QN7O, QXCO, QNCO

Model DY Vortex Flowmeter Model DYA Vortex Flow Converter Fieldbus Communication Type

Customer Drawings Product Selection

Analog Universal Module HART for Zone 2 Series 9468/33

YTA610 and YTA710 Temperature Transmitter (Hardware)

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Remote I/O. 74 Remote I/O. Remote I/O System

MODEL LP35 LP SERIES LOW PROFILE INTRINSIC SAFETY INCREMENTAL ENCODER

DPharp Fieldbus Communication Type (EJX A, EJA E)

User s Manual Diaphragm Sealed Differential Pressure and Pressure Transmitters EJ 118 and EJ 438

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

User s Manual Flange Mounted Differential Pressure Transmitters EJX210A and EJA210E

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier

Safety Instructions Nivotester FTC625, FTC325

Temperature Input Module for Zone 1 Series 9482/32

General Specifications

Digital Input Output Module for Zone 2 Series 9470/33

Certificate of Conformity

Isolators A3/1.

Fieldbus Solutions & Network Topologies. ISA Exhibition Toronto May 12, 2004

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

YTA Series Temperature Transmitters (Hardware) [Style: S3]

Isolating Repeater Input Series 9163

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D

megablock series passive hubs for fieldbus networks

technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks

User s Manual Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A

Digital Input Output Module for Zone 2 Series 9470/33

SET Installation and Operating Instructions. Level switch for two sensors

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

INSTRUCTION & SAFETY MANUAL

IECEx Certificate of Conformity

Field indicator for current loops with HART communication Models DIH50, DIH52

Transcription:

Instruction Manual Supplement DVC6200 Digital Valve Controllers IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions for Safe Use and Installations in Hazardous Locations Certain nameplates may carry more than one approval, and each approval may have unique installation/wiring requirements and/or conditions of safe use. These special instructions for safe use are in addition to, and may override, the standard installation procedures. Special instructions are listed by approval type. Note This information supplements the nameplate markings affixed to the product and the DVC6200 Series quick start guide (D103556X012), available from your Emerson sales office or Local Business Partner, or at Fisher.com. Always refer to the nameplate itself to identify the appropriate certification. WARNING Failure to follow these conditions of safe use could result in personal injury or property damage from fire or explosion and area re classification. Flameproof WARNING Do not open while energized. Potential electrostatic charging hazard. Do not rub or clean the cover with solvents. To do so could result in an explosion. Covered by Standards: IEC 60079-0:2011 IEC 60079-1:2007 DVC6200 and DVC6205 Series (HART HW1 & HW2, SIS, FOUNDATION Fieldbus, PROFIBUS) Ex d IIC T5 (Ta 80 C) / T6 (Ta 75 C) Gb 30 V max, 20 ma IP66 DVC6215 Remote Mount Ex d IIC T4 (Ta 125 C) / T5 (Ta 95 C) / T6 (Ta 80 C) Gb 30 V max, 20 ma IP66 www.fisher.com

DVC6200 Digital Valve Controllers Instruction Manual Supplement Dust WARNING Potential electrostatic charging hazard. Do not rub or clean the cover with solvents. To do so could result in an explosion. Covered by Standards: IEC 60079-0:2011 IEC 60079-31:2013 DVC6200 Series (HART HW1 & HW2, SIS, FOUNDATION Fieldbus, PROFIBUS) Ex tb IIIC T88 C (Ta 80 C) Db Approval requires fluorosilicone elastomers 30 V max, 20 ma IP66 Type n WARNING Do not open while energized. Potential electrostatic charging hazard. Do not rub or clean the cover with solvents. To do so could result in an explosion. Covered by Standards: IEC 60079-0:2011 IEC 60079-15:2010 DVC6200 and DVC6205 Series (HART HW1 & HW2, SIS, FOUNDATION Fieldbus, PROFIBUS) Ex nc IIC T5 (Ta 80 C) / T6 (Ta 75 C) Gc 30 V max, 20 ma IP66 DVC6215 Remote Mount Ex na IIC T4 (Ta 125 C) / T5 (Ta 95 C) / T6 (Ta 80 C) Gc 30 V max, 20 ma IP66 2

Instruction Manual Supplement DVC6200 Digital Valve Controllers Intrinsically Safe WARNING Potential electrostatic charging hazard. Do not rub or clean the cover with solvents. To do so could result in an explosion. The apparatus enclosure contains aluminum and is considered to constitute a potential risk of ignition by impact or friction. Care must be taken into account during installation and use to prevent impact or friction. Covered by Standards: IEC 60079-0:2011 IEC 60079-11:2011 DVC6200 Series (HART HW1 & HW2, SIS) or IIB T5/T6 Ga (see figures 1 and 5) Ex ia IIIC Txxx C Da (see figures 1 and 5) Dust approval requires fluorosilicone elastomers DVC6205 Series (HART HW2, SIS) or IIB T5/T6 Ga (see figure 2) DVC 6200 Series (FOUNDATION Fieldbus, PROFIBUS) T4/T5/T6 Ga (see figure 3) Ex ia IIIC Txxx C Da (see figure 3) Dust approval requires fluorosilicone elastomers DVC6205 Series (FOUNDATION Fieldbus, PROFIBUS) T4/T5/T6 Ga (see figure 4) IP66 DVC6215 Remote Mount T4/T5/T6 Ga (see figure 2 and 4) 3

DVC6200 Digital Valve Controllers Instruction Manual Supplement Intrinsically safe when connected per drawing GE42990, as shown in the following figures DVC6200 HW2 and DVC6200 SIS... figure 1 and 6 DVC6205, DVC6205 SIS, and DVC6215 Remote Mount... figure 2 and 6 DVC6200f and DVC6200p... figure 3 and 6 DVC6205f, DVC6205p, and DVC6215 Remote Mount... figure 4 and 6 DVC6200 HW1... figure 5 and 6 4

Instruction Manual Supplement DVC6200 Digital Valve Controllers Figure 1. IECEx Loop Schematics FIELDVUE DVC6200 HW2 and DVC6200 SIS ZONE 0, OR IIB T5 T6 ** ZONE 20, Ex ia IIIC Txx C HW2 - WITH OR WITHOUT I/O PACKAGE DVC6200, DVC6200S NON Ii = 130 ma Pi = 1.0 W * Li = 0.15 mh Not Used or Not Provided Ii = 101 ma Pi = 757 mw Li = 0.30 mh Io = 101 ma Po = 757 mw Co = 52.4 nf Lo = 5.84 mh Ui = 27.1 VDC Ii = 130 ma Pi = 880 mw Li = 0.30 mh Uo = 27.1 VDC Io = 130 ma Po = 880 mw Co = 75 nf Lo = 2.73 mh Ex ia IIB Ii = 130 ma Pi = 1.0 W Li = 0.30 mh Io = 130 ma Po = 1.0 W Co = 546 nf Lo = 16.93 mh NOTE 5 1 BARRIER NOTE 1, 3, 4 1 *Li = 0.15 mh WHEN THE AUX TERMINALS ARE NOT USED OR IF THEY ARE NOT PROVIDED *** EQUIPMENT MARKED Ex ia IIIC Txx C MAY USE ANY OF THE ENTITY PARAMETERS STATED ABOVE. or Ex ia IIB OUTPUT TERMINALS Ui = 28 VDC Ii = 100 ma Pi = 1.0 W Li = 0.20 mh BARRIER NOTE 1, 3, 4 1 DVC6200 DVC6200S or IIB T5 T6 WITHOUT I/O PACKAGE WITH I/O PACKAGE WITHOUT I/O PACKAGE T91 C (Ta 80 C) T85 C (Ta 74 C) **Ex ia IIIC Txx C WITH I/O PACKAGE Txx C = Txx C = T5 (Ta 80 C) T6 (Ta 74 C) T5 (Ta 80 C) T6 (Ta 61 C) T104 C (Ta 80 C) T85 C (Ta 61C) POWER MAY BE APPLIED TO EITHER THE LOOP TERMINALS OR OUTPUT TERMINALS OR TO BOTH SETS OF TERMINALS AT THE SAME TIME UNITS WITHOUT I/O PACKAGE WILL NOT HAVE OUTPUT TERMINALS OR AVAILABLE FOR CONNECTION GE42990 Sheet 11, Rev. C **ONLY IF THE NAMEPLATE BEARS THIS MARKING. 5

DVC6200 Digital Valve Controllers Instruction Manual Supplement Figure 2. IECEx Loop Schematics FIELDVUE DVC6205, DVC6205 SIS, and DVC6215 ZONE 0, OR Ex ia IIB T5 T6 HW2 - WITH OR WITHOUT I/O PACKAGE DVC6205 REMOTE FIELD WIRING TERMINAL BOX FIELD WIRING TERMINAL BOX ZONE 0, T4 T6 DVC6215 Ii = 226 ma Ci = 50 nf Li= 0.55 mh or Ex ia IIB TERMINALS Io = 21.2 ma Po = 160 mw Co = 55 nf Lo = 78 mh Ii = 130 ma Pi = 1.0 W * Li = 0.15 mh Not Used or Not Provided Ii = 101 ma Pi = 757 mw Li = 0.30 mh Io = 101 ma Po = 757 mw Co = 52.4 nf Lo = 5.84 mh NOTE 1, 3 1 *Li = 0.15 mh WHEN THE AUX TERMINALS ARE NOT USED OR IF THEY ARE NOT PROVIDED or Ex ia IIB T4 T6 T4 (Ta 125 C) DVC6215 T5 (Ta 95 C) T6 (Ta 80 C) GE42990 Sheet 12 Rev. C DVC6205 WITHOUT I/O PACKAGE T5 (Ta 80 C) T6 (Ta 74 C) WITH I/O PACKAGE T5 (Ta 80 C) T6 (Ta 61 C) 6

Instruction Manual Supplement DVC6200 Digital Valve Controllers NON Ui = 27.1 VDC Ii = 130 ma Pi = 880 mw Li = 0.30 mh Ex ia IIB Ii = 130 ma Pi = 1.0 W Li = 0.30 mh BARRIER Uo = 27.1 VDC Io = 130 ma Po = 880 mw Co = 75 nf Lo = 2.73 mh Io = 130 ma Po = 1.0 W Co = 546 nf Lo = 16.93 mh NOTE 5 1 NOTE 1, 3, 4 1 or Ex ia IIB OUPUT TERMINALS Ui = 28 VDC Ii = 100 ma Pi = 1.0 W Li = 0.20 mh BARRIER NOTE 1, 3, 4 1 POWER MAY BE APPLIED TO EITHER THE LOOP TERMINALS OR OUTPUT TERMINALS OR TO BOTH SETS OF TERMINALS AT THE SAME TIME UNITS WITHOUT I/O PACKAGE WILL NOT HAVE OUTPUT TERMINALS OR AVAILABLE FOR CONNECTION 7

DVC6200 Digital Valve Controllers Instruction Manual Supplement Figure 3. IECEx Loop Schematics FIELDVUE DVC6200f and DVC6200p T4 T6 T4 (Ta 80 C) T5 (Ta 77 C) T6 (Ta 62 C) *Ex ia IIIC Txx C Txx C = T103 C (Ta 80 C) T100 C (Ta 77 C) T85 C (Ta 62 C) ZONE 0, T4 T6 * ZONE 20, Ex ia IIIC Txx C DVC6200F, DVC6200FS DVC6200P, DVC6200PS NON ENTITY DEVICE Ui = 24 VDC Ii = 380 ma Li = 0 mh NOTE 1, 3 1 BARRIER 1 NOTE 5 GE42990 Sheet 3, Rev. F 1 NOTE 1, 3, 4 *ONLY IF THE NAMEPLATE BEARS THIS MARKING. ENTITY FIELDBUS LOOP T4 T6 T4 (Ta 80 C) *Ex ia IIIC Txx C Txx C = T103 C (Ta 80 C) NON T5 (Ta 77 C) T6 (Ta 62 C) T100 C (Ta 77 C) T85 C (Ta 62 C) ZONE 0, T4 T6 * ZONE 20, Ex ia IIIC Txx C DVC6200F, DVC6200FS DVC6200P, DVC6200PS FISCO DEVICE Ui = 17.5 VDC Ii = 380 ma Li = 0 mh Pi = 5.32 W NOTE 2, 3 1 FISCO TERMINATOR FISCO BARRIER GE42990 Sheet 4, Rev. F 1 NOTE 2, 3, 4 FISCO LOOP *ONLY IF THE NAMEPLATE BEARS THIS MARKING. 8

Instruction Manual Supplement DVC6200 Digital Valve Controllers Figure 4. IECEx Loop Schematics FIELDVUE DVC6205f, DVC6205p, and DVC6215 NON ENTITY DEVICE NOTE 1, 3 1 ZONE 0, T4 T6 DVC6215 Ii = 226 ma Ci = 50 nf Li = 0.55 mh NOTE 1, 3 1 ZONE 0, T4 T6 DVC6205f, DVC6205p REMOTE FIELD WIRING TERMINAL BOX TERMINALS Uo = 24 VDC Io = 44 ma Co = 121 nf Lo = 30 mh Po = 0.33 W FIELD WIRING TERMINAL BOX LOOP TERMINALS Ui = 24 VDC Ii = 380 ma Li = 0 mh BARRIER NOTE 5 1 DVC6215 T4 T6 T4 (Ta 125 C) T5 (Ta 95 C) T6 (Ta 80 C) DVC6205F DVC6205P T4 T6 T4 (Ta 80 C) T5 (Ta 77 C) T6 (Ta 62 C) 1 NOTE 1, 3, 4 GE42990 Sheet 9, Rev. D ENTITY FIELDBUS LOOP NON IECEx APPROVED FISCO DEVICE NOTE 2, 3 1 ZONE 0, T4 T6 Ii = 226 ma Ci = 50 nf Li = 0.55 mh NOTE 2 1 DVC6215 ZONE 0, T4 T6 REMOTE DVC6205f, DVC6205p FIELD WIRING FIELD WIRING TERMINAL BOX TERMINAL BOX TERMINALS Uo = 17.5 VDC Io = 44 ma Co = 121 nf Lo = 30 mh Po = 0.33 W LOOP TERMINALS Ui = 17.5 VDC Ii = 380 ma Li = 0 mh Pi = 5.32 W FISCO BARRIER FISCO TERMINATOR GE42990 Sheet 10, Rev. D DVC6215 T4 T6 T4 (Ta 125 C) T5 (Ta 95 C) T6 (Ta 80 C) FISCO LOOP DVC6205F DVC6205P T4 T6 T4 (Ta 80 C) T5 (Ta 77 C) T6 (Ta 62 C) 1 NOTE 2, 3, 4 9

DVC6200 Digital Valve Controllers Instruction Manual Supplement Figure 5. IECEx Schematic FIELDVUE DVC6200 HW1 NON ZONE 0, OR IIB T5 T6 * ZONE 20, Ex ia IIIC Txx C DVC6200, DVC6200S Ii = 226 ma Li = 0.55 mh Ii = 101 ma Pi = 757 mw Li = 0.55 mh Ui = 24.3 VDC Ii = 169 ma Pi = 1.026 W Li = 0.55 mh Ex ia IIB Ii = 226 ma Li = 0.55 mh BARRIER Not Used Io = 101 ma Po = 757 mw Co = 64 nf Lo = 5.34 mh Uo = 24.3 VDC Io = 169 ma Po = 1.026 W Co = 118 nf Lo = 0.30 mh Io = 226 ma Po = 1.4 W Co = 558 nf Lo = 3.76 mh NOTE 5 1 NOTE 1, 3, 4 1 ** EQUIPMENT MARKED Ex ia IIIC Txx C MAY USE ANY OF THE ENTITY PARAMETERS STATED ABOVE. DVC6200 DVC6200S OR IIB T5 T6 T5 (Ta 80 C) T6 (Ta 75 C) *Ex ia IIIC Txx C Txx C = T89 C (Ta 80 C) T85 C (Ta 76 C) GE42990 Sheet 2, Rev. F *ONLY IF THE NAMEPLATE BEARS THIS MARKING. 10

Instruction Manual Supplement DVC6200 Digital Valve Controllers Figure 6. Notes for IECEx Loop Schematics THE APPARATUS ENCLOSURE CONTAINS ALUMINUM AND IS CONSIDERED TO CONSTITUTE A POTENTIAL RISK OF IGNITION BY IMPACT AND FRICTION. AVOID IMPACT AND FRICTION DURING INSTALLATION AND USE TO PREVENT RISK OF IGNITION. THE ENTITY CONCEPT ALLOWS INTERCONNECTION OF INTRINSICALLY SAFE APPARATUS TO ASSOCIATED APPARATUS NOT SPECIFICALLY EXAMINED IN SUCH COMBINATION. THE CRITERIA FOR INTERCONNECTION IS THAT THE VOLTAGE (Vmax OR Ui), THE CURRENT (Imax OR Ii), AND THE POWER (Pmax or Pi) OF THE INTRINSICALLY SAFE APPARATUS MUST BE EQUAL TO OR GREATER THAN THE VOLTAGE (Voc OR Uo), AND THE CURRENT (Isc OR Io), AND THE POWER (Po) DEFINED BY THE ASSOCIATED APPARATUS. IN ADDITION, THE SUM OF THE MAX UNPROTECTED CAPACITANCE (Ci) AND MAX UNPROTECTED INDUCTANCE (Li), INCLUDING THE INTERCONNECTING CABLING CAPACITANCE (Ccable) AND CABLING INDUCTANCE (Lcable) MUST BE LESS THAN THE ALLOWABLE CAPACITANCE (Ca) AND INDUCTANCE (La) DEFINED BY THE ASSOCIATED APPARATUS. IF THE ABOVE CRITERIA IS MET, THEN THE COMBINATION MAY BE CONNECTED. Vmax or Ui Voc or Uo Imax or Ii Isc or Io Pmax or Pi Po Ci + Ccable Ca Li + Lcable La THE FISCO CONCEPT ALLOWS INTERCONNECTION OF INTRINSICALLY SAFE APPARATUS TO ASSOCIATED APPARATUS NOT SPECIFICALLY EXAMINED IN SUCH COMBINATION. THE CRITERIA FOR THE INTERCONNECTION IS THAT THE VOLTAGE (Vmax OR Ui), CURRENT (Imax OR Ii), AND POWER (Pmax or Pi), WHICH AN INTRINSICALLY SAFE APPARATUS CAN RECEIVE AND REMAIN INTRINSICALLY SAFE, CONSIDERING FAULTS, MUST BE EQUAL TO OR GREATER THAN THE VOLTAGE (Voc OR Uo), CURRENT (Isc OR Io), AND POWER (Po) LEVELS WHICH CAN BE DELIVERED BY THE ASSOCIATED APPARATUS, CONSIDERING FAULTS AND APPLICABLE FACTORS. IN ADDITION THE MAXIMUM UNPROTECTED CAPACITANCE (Ci) AND INDUCTANCE (Li) OF EACH APPARATUS (OTHER THAN THE TERMINATION) CONNECTED TO THE FIELDBUS MUST BE LESS THAN OR EQUAL TO 5 nf AND 10 uh RESPECTIVELY. IN EACH SEGMENT ONLY ONE ACTIVE DEVICE, NORMALLY THE ASSOCIATED APPARATUS, IS ALLOWED TO PROVIDE THE NECESSARY ENERGY FOR THE FIELDBUS SYSTEM. THE VOLTAGE (Uo OR Voc OR Vt) OF THE ASSOCIATED APPARATUS HAS TO BE LIMITED TO THE RANGE OF 9 V TO 17.5 VDC. ALL OTHER EQUIPMENT CONNECTED TO THE BUS CABLE HAS TO BE PASSIVE, MEANING THAT THEY ARE NOT ALLOWED TO PROVIDE ENERGY TO THE SYSTEM, EXCEPT FOR A LEAKAGE CURRENT OF 50 ua FOR EACH CONNECTED DEVICE. SEPARATELY POWERED EQUIPMENT NEEDS A GALVANIC ISOLATION TO ASSURE THAT THE INTRINSICALLY SAFE FIELDBUS CIRCUIT REMAINS PASSIVE. THE CABLE USED TO CONNECT THE DEVICES NEEDS TO HAVE THE PARAMETERS IN THE FOLLOWING RANGE: LOOP RESISTANCE R': 15 TO 150 ohms/km INDUCTANCE PER UNIT LENGTH L: 0.4 TO 1 mh/km CAPACITANCE PER UNIT LENGTH C': 80 TO 200 nf/km C' = C' LINE/LINE + 0.5' LINE/SCREEN, IF BOTH LINES ARE FLOATING OR C' = C' LINE/LINE + C' LINE/SCREEN, IF THE SCREEN IS CONNECTED TO ONE LINE. LENGTH OF SPLICE: < 1 m (T BOX MUST ONLY CONTAIN TERMINAL CONNECTIONS WITH NO ENERGY STORAGE CAPABILITY) LENGTH OF SPUR CABLE: < 30 M LENGTH OF TRUNK CABLE: < 1 km AT EACH END OF THE TRUNK CABLE AN APPROVED INFALLIBLE TERMINATION WITH THE FOLLOWING PARAMETERS IS SUITABLE: R = 90 TO 100 ohms AND C = 0 TO 2.2 uf NOTE, A BUILT IN TERMINATOR IS INCLUDED IN THE FIELD SIDE AND A SELECTABLE TERMINATOR IS AVAILABLE ON THE HOST SIDE. THE NUMBER OF PASSIVE DEVICES CONNECTED TO THE BUS SEGMENT IS NOT LIMITED IN THE FISCO CONCEPT FOR INTRINSICALLY SAFE REASONS. IF THE ABOVE RULES ARE RESPECTED, UP TO A TOTAL LENGTH OF 1000 m (SUM OF THE LENGTH OF THE TRUNK CABLE AND ALL SPUR CABLES), THE INDUCTANCE AND CAPACITANCE OF THE CABLE WILL NOT IMPAIR THE INTRINSIC SAFETY OF THE INSTALLATION. INSTALLATION MUST BE IN ACCORDANCE WITH THE NATIONAL WIRING PRACTICES OF THE COUNTRY IN USE. LOOPS MUST BE CONNECTED ACCORDING TO THE BARRIER MANUFACTURER'S INSTRUCTIONS. IF HAND HELD COMMUNICATOR OR MULTIPLEXER IS USED, IT MUST BE WITH ENTITY PARAMETERS AND INSTALLED PER THE MANUFACTURER'S CONTROL DRAWINGS. GE42990 Sheet 8, Rev. E 11

DVC6200 Digital Valve Controllers Instruction Manual Supplement Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Automation Solutions Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Cernay, 68700 France Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com 12 2017 Fisher Controls International LLC. All rights reserved.