Output Signal Active Note. Output Signal Temperature 22UTH-51 DC V, DC V

Similar documents
Type Overview. Technical Data. Outdoor Humidity, Temperature Sensor

Output Signal Active Temperature. Electrical data Power Supply DC V, ±10%, 0.5 W

SENSORS. Seamlessly Integrated SENSORS

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

THM80X Series Industry degree high accuracy Temp. & humidity transmitter

Room sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Power consumption In operation At rest For wire sizing

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Overview of types. Technical data

MODEL AT-10 ANALOG TRANSMITTER

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application

Outside Temperature Sensors

Pressure transmitter for general industrial applications Model A-10

MTV-1-CP 230 VAC POTENTIOMETER WITH MIN & MAX SETTINGS, DRY CONTACT. Mounting and operating instructions

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Technical data sheet. Technical data. Safety notes

RSMFX-2R MULTIFUNCTIONAL

Pressure transmitter for general industrial applications Model A-10

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Power consumption In operation At rest For wire sizing

Pressure transmitter For general industrial applications Model A-10

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

SELECTION TABLES OF TEMPERATURE,HUMIDITY, PRESSURE CO TRANSMITTERS Txxxx, Pxxxx

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Technical Data. General specifications. Rated operating distance s n 3 mm

High-quality pressure transmitter For general industrial applications Model S-20

Digital inductive conductivity transmitter

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Power consumption In operation At rest For wire sizing

Type EXT with cable, probe sold

USER'S GUIDE. Vaisala HUMICAP Humidity and Temperature Transmitters HMD70U/Y U303EN11

Technical data. Parameterisable damper actuator in the

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

D Series Sensors for Humidity and Temperature Measurement Type DI Room version Optional display Technical data Humidity

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

STC65 RS485 Modbus. EnOcean Receiver/Transmitter with RS485 Modbus Interface. Data Sheet. Application. Security Advice Caution.

Digital flow transmitter for continuous flow measurement

Hygro-ThermoTransmitter-compact xxx

Functional data Factory settings Variable Settings

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Digital flowmeter for continuous flow measurement

Pharma Temperature Sensor G3/8"

Digital flowmeter for continuous flow measurement

Power consumption Operation At rest Wire sizing

Humidity Sensor/Transmitter Assembly

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

OPTITEMP TT 20 Technical Datasheet

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

Loop Powered Indicator

PAD - Heavy Duty Differential Pressure Trasmitter

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

Relative and absolute pressure transmitter type 528

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

QPM Series Indoor Air Quality Duct Sensors

COMMERCIAL. GA Series - Actuator Operating Instructions. GA Non-Spring Return Actuator - (GA24-562) 04/08 /15

Temperature Sensor Tri-Clamp

Pressure Transmitter SIL

Pressure transmitter For general industrial applications Model A-10

Euromas Polymas. Colour: Silver grey, similar to RAL 7001; special colours on request

Room Sensors. for relative humidity and temperature

B850 Boiler House Energy Monitor

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Temperature Sensor with Thread G1/4" FLEXadapt

Flow Measurement SITRANS F M

FINAL. Hygro-ThermoTransmitter-compact xxx xxx MEETINSTRUMENTATIE. Instruction for use /06/ x4.0xx/1xx/4xx/8xx...

Technical Application Guide

Digital batch controller

ED701 General Industry Pressure Transmitter

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Safety switches with slotted hole lever

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Non-Spring Return EconoDrive Proportional Actuator

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Technical Information Smartec CLD18

Transcription:

Outdoor Humidity, Temperature Sensor ±2% accurate humidity and temperature sensor for outdoor applications. Temperature is available with dual active 4 to 20 ma outputs or passive only for temperature. NEMA 4X /IP65 rated enclosure standard. Field selectable output for RH, absolute humidity, dew point or enthalpy. Type Overview Type Active Temperature 22UTH-51 DC 0...5 V, Active Humidity DC 0...5 V, 22UTH-510B - DC 0...5 V, 22UTH-510E - DC 0...5 V, 22UTH-510L - DC 0...5 V, 22UTH-510M - DC 0...5 V, 22UTH-510Q - DC 0...5 V, Passive Temperature - PT1000 Ni1000 (JCI) NTC10k2 NTC10k3 NTC20k Technical Data Electrical Data Power Supply DC 15...24 V, ±10%, 0.3 W Power Supply AC Cable Entry 24 V, ±10%, 0.5 VA cable gland PG11 Ø6 to 10 mm, with strain relief Ø6 to 8 mm, 1/2" conduit adapter included Functional Data Sensor Technology polymer capacitive sensor with stainless steel wire mesh Passive Temperature Active Note Media PT1000 Ni1000 (JCI) NTC10k2 NTC10k3 NTC20k output DC 0 to 5/10 V with jumper adjustable voltage output: min. 10 kω load air www.belimo.com en-us 2018-01-08 Subject to change 1 / 5

Measuring Data Measured Values temperature relative humidity dew point enthalpy absolute humidity Measuring Range Humidity Measuring range temperature Measuring Range Absolute Humidity Measuring Range Enthalpy Measuring Range Dew Point Accuracy Humidity Accuracy temperature active Accuracy temperature passive 0 to 100% RH non-condensing passive sensor: -30 F to 120 F [-35 C to 50 C] Active sensor: range selectable Attention: max. measuring temperature is restricted by max. medium temperature (see Safety data) Settingrange [ C] range [ F] S0 S1 S2 S3-40 C to 60 C 0 C to 50 C -15 C to 35 C -20 C to 80 C -40 F to 160 F 40 F to 140 F 0 F to 100 F 0 F to 200 F adjustable at the transducer: 0 to 50 g/m³ (default setting) 0 to 80 g/m³ 0 to 85 kj/kg Materials Cable Gland PA6, black Housing Factory setting Export Media AP Web adjustable at the transducer: 40 F to 140 F [0 C to 50 C] (default setting) 0 F to 200 F [-20 C to 80 C] ±2% between 10 to 90% RH @ 70 F [21 C] ±0.9 F @ 77 F [±0.5 C @ 25 C] passive sensors depending on used type Ni.. = ±0.7 F @ 32 F [±0.4 C @ 0 C] NTC.. = ±0.3 F @ 77 F [±0.2 C @ 25 C] cover: lexan, gray base: lexan, gray seal: 0467 NBR70, black Safety Data Ambient Temperature -30 F to 120 F [-35 C to 50 C] Medium Temperature Protection Class IEC/EN Protection Class UL -30 F to 120 F [-35 C to 50 C] III safety extra-low voltage (selv) UL Class 2 Supply Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-13 Certification UL Degree of Protection IEC/EN Degree of Protection NEMA/ UL culus acc. to UL60730-1A/-2-9/-2-13, CAN/ CSA E60730-1:02/-2-9, CE acc. to 2004/108/ EC and 2006/95/EC, NEMA 4X, IP65, UL Enclosure Type 4X IP65 NEMA 4X Quality Standard ISO 9001 Weight 0.21 lbs www.belimo.com en-us 2018-01-08 Subject to change 2 / 5

Safety Notes Remarks Application Notice for Humidity Sensors The installation and assembly of electrical equipment should only be performed by authorized personnel. The product should only be used for the intended application. Unauthorized modifications are prohibited! The product must not be used in relation with any equipment that in case of a failure may threaten, directly or indirectly, human health or life or result in danger to human beings, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment. Please comply with Local laws, health & safety regulations, technical standards and regulations Condition of the device at the time of installation, to ensure safe installation This data sheet and installation manual Refrain from touching the sensitive humidity sensor/element. Touching the sensitive surface will void warranty. For standard environmental conditions the manufacturing accuracy specified in the datasheet will be covered by the calibration warranty for two years. When exposed to harsh environmental conditions such as; high ambient temperature and/or high levels of humidity or presence of aggressive gases (i.e. chlorine, ozone, ammonia) the sensor element may be affected and readings may be outside specified accuracy. Replacement of deteriorated humidity sensor due to harsh environmental conditions are not subject of the general warranty. Accessories Scope of Delivery mounting plate dowel screws Rain cover cable gland nut conduit 1/2" NPT www.belimo.com en-us 2018-01-08 Subject to change 3 / 5

S ens or Datas heet 22UT H-51.. Wiring Diagram rh Relative humidity absh Absolute humidity EntH Enthalpy TPkt/Dew Dew point the adjustment of the measuring ranges is made by changing the bonding jumpers the output value in the new measuring range is available after 2 seconds Setting range [ C] range [ F] Factory Export Media AP setting Web S0-40 C to 60 C -40 F to 160 F S1 0 C to 50 C 40 F to 140 F S2-15 C to 35 C 0 F to 100 F S3-20 C to 80 C 0 F to 200 F www.belimo.com en-us 2018-01-08 Subject to change 4/5

Dimensions www.belimo.com en-us 2018-01-08 Subject to change 5 / 5