Similar documents

GRILLE AND REGISTER OPTIONS AND ACCESSORIES

LINEAR AIR GRILLE LF - 202/LF 212 / LF / LF ACCESSORIES

LINEAR DIFFUSERS AND BAR GRILLES

Ductwork Controls and Instrumentation Outlets (HVAC) HVAC Control System.

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

LINEAR GRILLES AND REGISTERS

Stripmaster Wire Strippers

Ordering example: WSK-600 / B x H x L = 155 mm. M8 hexagon head screw, fixed by a locknut. Threaded bolt

Bol FEATURES: SPECIFICATIONS: 8' 24' Round Tapered and Straight Wood Poles STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:

Model 30/L/0. Model 30/S/0. Shortl Blades, 0 Deflection 3/4" Spacing. Model 35/S/0 Short Blades, 0 Deflection 1/2" Spacing

GRILLES AND REGISTERS

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

IBD23 CURTAIN TYPE STATIC FIRE DAMPERS 3 HOUR UL555 RATED FOR USE IN STATIC SYSTEMS

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing.

Flange Dimensions Class 125 Bronze Flange Dimensions Class 300 Bronze Flange Dimensions Class 150 Bronze Flange Dimensions

Walls Fact Sheets. Partition Walls and Walls Cladding. Perforated Board. Sandwich Board

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

Light Structural Main Runner Light Structural Infill Tees. Straight Connector. Strut Structural Tee thread

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

SCD, ASCD Square Cone Diffuser CM = CEILING MODULE CEILING OPENING D = DUCT SIZE. OD = D - 1/8" (3mm)

APPENDIX A, UMC STANDARD 6-5 STANDARD FOR INSTALLATION OF FACTORY-MADE AIR DUCTS

NOTES: Dimensions in parentheses are mm. For 1600 grille length and width dimensional information, see table on page K1-25.

PIPE/CONDUIT SUPPORTS

SCREW THREADS. = minor diameter. d 3. d 2. = pitch diameter

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

Round Duct and Fittings. Standards and Dimensional Data for Air Duct and Fittings

Jabiru Installation instructions

PERIMETER SMOKE SEALS

NON-PENETRATING ROOFTOP HANGERS AND SUPPORTS

Framing Components. Spacers, Gaskets, Cladding. Framing, Spacers & Cladding Pages

Specifications - Common Nails Diamond point, Flat head, round smooth shank, Bright, HDG, EG or cement coated (resin or vinyl) finish

IOM 004 Effective 3/29/04 Rev A. MULTI-VENT Laminar Flow Panels Installation Operation and Maintenance

HVAC Spiral Pipe Component Parts

The EDGE Self-Sealing Round Duct System

A. ASTM D Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.

American Power Design, Inc.

NEER Zinc Cable and Conduit Connectors For Flexible Metal Conduit

Thru Wall Floor Seals For New Installation

Stripmaster Wire Stripper. Specifications Stripping Hole Diameter in Inches (mm) Wire Size AWG

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

Fixture Holes Explanation

M1.0 MECHNANICAL FLOOR PLAN

Mechanical System Specifications & Detail Drawings

MANUAL INSTALLATION. Linear Bar Grille LBP. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.

Iberville. Commercial Grade Fittings EMT CI5410 / CI5432 CI5410IT / CI5432IT CI5404 / CI5408 CI5404IT / CI5408IT CI5004 (-IT) / CI5008 (-IT)

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools...

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

DUO-TAPTITE. Fasteners DUO-TAPTITE. Thread Rolling Screws

MANUAL INSTALLATION. Linear Bar Grille - Heavy Duty LBPH/LBMH. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.

SECTION AIR DISTRIBUTION SYSTEM

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features

*************************************************************************************************************

Single-Hung Windows Premium Atlantic Aluminum

1.) Type: VL-F Single compartment rectangular smoke extraction ducts and fittings

General Information...SA1-SA4

VAV Rectangular Terminal Units

Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job:

Small Block Ford. 289 / 302 / 351W / 5.0 Installation Manual For Systems with A/C #13600 / #13620

SECTION 10. SAFETY METHODS FOR TURNBUCKLES

UNIFIED FACILITIES GUIDE SPECIFICATIONS

TABLE OF CONTENTS: SHEET 3: REMOTE DRIVER BOX INSTALLATION SHEET 7: OCTAGON JUNCTION BOX INSTALLATION

Ground Clamps Cable Tray

Installation Instructions

TAPTITE Fasteners. High Performance Thread Rolling Screws for Metals

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS

Small Block Ford. 289 / 302 / 351W / 5.0 Installation Manual For Systems without A/C #13605 / #13625

CAN BE INSTALLED DIGITAL DEPTH GAGE WITH EXTENSION BASE DATA OUTPUT 48-52, MM/INCH

METRIC FASTENERS 1520 METRIC FASTENERS

Engineering Data Rail Lifters

77 cm. 5243/3-GA (3 pcs.) 5243/3-BO (3 pcs.)

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

1. ASME A Scheme for the Identification of Piping Systems.

DIBD20, 40, 60 AND DIBD230, 430, 630 CURTAIN TYPE DYNAMIC FIRE DAMPERS

Product Selection Guide

!When using electrical equipment, basic safety precautions should always be followed, including the following: INSTALLATION INSTRUCTIONS

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM )

Delikon Stainless Steel Liquidtight Connectors offer corrosion resistance and the strength of stainless steel for the highest levels of endurance.

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS

3 Eco-Downlight IC Air-Tight Adjustable New Construction Housing Round or Square

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW

Storefront Installation Guide

Square Shear Beam Mounting Guidelines

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

SECTION MECHANICAL IDENTIFICATION

R SERIES Premium Music R.5-96MAX HIGH OUTPUT FULL-RANGE 90 x 60 WEATHER-RESISTANT LOUDSPEAKER

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

Body Repair. Collision Repair. Specification. Fastener Specifications Fastener Specifications. Blind Rivet. Flow Drill Screw (FDS) Torque FDS

CARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Specification Tapped holes f. coupl Scope Allocation of the JED Numbers General...

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

1.2 Overview. Self-adhesive mounting bases and clamps for screw and rivet mounting. Typical applications

Pioneers in Gate Design

05/11. CI/SfB (22) flexplus. tenon. Versatility through simplicity.

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Transcription:

Submittal Sheet COUNTERSUNK HOLES SDG SPIRAL DUCT GRILLE 1 7/8" (47) + 1 1/4" (32) - 3/4" (19) ( DUCT OPENING ) END GASKET NOM. LENGTH - 3/4" (19) OPTIONAL AIR SCOOP AIR SCOOP (ROD OPERATOR) NOM. LENGTH ( DUCT OPENING ) NOM. LENGTH + 2 7/8" (73) RECOMMENDED SDG SIZE FOR SPECIFIED DUCT DIAMETER DUCT SIZE MINIMUM MAXIMUM (DIAMETER) SIZE NOM.WIDTH SIZE 8" - 13" - 4" 14" - 21" 4" 6" 22" - 31" 4" 8" 32" - 41" 4" 10" 42" - OVER 4" 12" DAMPER OPTIONS: AS: AIR SCOOP (ROD OPERATOR) ASC: AIR SCOOP (CABLE OPERATOR) 3: VCS3 COATED STEEL OPPOSED BLADE DAMPER NOTES: INTENDED FOR USE IN SPIRAL OR ROUND DUCT APPLICATIONS (MINIMUM DUCT SIZE 8" (203) MINIMUM NOM. LENGTH IS 10" (254) MAXIMUM NOM. LENGTH IS 36" (914) MULLIONS ARE USED WHEN BLADE LENGTH EXCEEDS 24" AVAILABLE SIZE IN 1" INCREMENTS 3/4" BLADE SPACING OPEN CELL FOAM INSULATION PROVIDES A TIGHT SEAL AROUND THE GRILLE OPENING IN ANY ROUND DUCT (GREY STANDARD) OPTIONAL AIR-SCOOP AVAILABLE FACTORY TOLERANCE +/ 1/32" (1) GALVANIZED UNITS ARE MILL FINISH. STEEL AND GALVANIZED MODELS COME WITH GALVANIZED SCOOP. ALUMINUM MODEL COMES WITH MILL FINISH ALUMINUM SCOOP. BLADE ORIENTATION - FRONT SET: S L OPTIONAL AIR SCOOP PARALLEL TO SHORT DIM PARALLEL TO LONG DIM END GASKET COLOR OPTIONS: GREY WHITE BLACK AIR SCOOP (CABLE OPERATOR) MATERIAL: ST STEEL FRAME AND BLADES GV GALVANIZED STEEL FRAME AND BLADES AL ALUMINUM FRAME AND BLADES FINISH: B12 WHITE (ST & AL) (OTHER FINISHES AVAILABLE) GV MILL FINISH END GASKET PROJECT: ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER. ENGINEER: SDG CUSTOMER: 245808 SPIRAL DUCT GRILLE SUBMITTAL DATE: SPEC. SYMBOL: DEC 2012 Copyright E.H.PRICE LIMITED 2005 ECN: SHEET 1 OF 1 REV G

SDGE - SPIRAL DUCT GRILLE EXTRUDED Submittal Sheet OPTIONAL AIR SCOOP OPTIONAL AIR SCOOP AIR SCOOP (ROD OPERATOR) 7/8" (22) AIR SCOOP (CABLE OPERATOR) VARIES WITH DUCT DIAMETER NOM. LENGTH - 5/8" (16) DUCT OPENING = NOM. LENGTH OVERALL = NOM. LENGTH + 1" (25) -1/4" (6) DUCT OPENING = 1" u1/8" (3) STANDARD CONSTRUCTION: FRAMES: EXTRUDED ALUMINUM BLADES: EXTRUDED ALUMINUM 3/4" BLADE SPACING DAMPER OPTIONS: AS: AIR SCOOP (ROD OPERATOR) ASC: AIR SCOOP (CABLE OPERATOR) 3: VCS3 COATED STEEL OPPOSED BLADE DAMPER AVAILABLE CONFIGURATIONS: DOUBLE DEFLECTION, FRONT BLADES PARALLEL TO LENGTH DOUBLE DEFLECTION, FRONT BLADES PARALLEL TO WIDTH SINGLE DEFLECTION, BLADES PARALLEL TO LENGTH SINGLE DEFLECTION, BLADES PARALLEL TO WIDTH FINISH: B12 WHITE (OPTIONAL FINISHES AVAILABLE) AC CLEAR ANODIZED FASTENING OPTIONS & ACCESSORIES: "A" MOUNTING STANDARD NOTES: NOMINAL LENGTHS AVAILABLE IN 1" INCREMENTS. FOR ONE-PIECE CONSTRUCTION: MIN. NOMINAL LENGTH = 6" MAX. NOMINAL LENGTH = 36" FACTORY TOLERANCE +/- 1/32" (1) PROJECT: Available Sizes Duct Dia. Nom. Widths 3 4 6 8 10 12 6 x x 8 x x x 10 x x x x 12 x x x x x 14 x x x x x x 16 x x x x x x 18 x x x x x x 20 x x x x x x 22 x x x x x x 24 x x x x x x 26 x x x x x x 28 x x x x x x 30 x x x x x x 32 x x x x x x 36 x x x x x x ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER. ENGINEER: CUSTOMER: SUBMITTAL DATE: SPEC. SYMBOL: 245972 DEC 2012 SDGE SPIRAL DUCT GRILLE EXTRUDED Copyright E.H.PRICE LIMITED 2007 ECN: SHEET 1 OF 1 REV E

SDGR SPIRAL DUCT GRILLE RETURN Submittal Sheet COUNTERSUNK HOLES 1 7/8 (47) + 1 1/4 (32) - 3/4 (19) ( DUCT OPENING ) NOM. LENGTH - 3/4 (19) NOM. LENGTH ( DUCT OPENING ) NOM. LENGTH + 2 7/8 (73) GASKET NOTES: RECOMMENDED SDGR SIZE FOR SPECIFIED DUCT DIAMETER DUCT SIZE MINIMUM MAXIMUM (DIAMETER) SIZE NOM.WIDTH SIZE 8" - 13" - 4" 14" - 21" 4" 6" 22" - 31" 4" 8" 32" - 41" 4" 10" 42" - OVER 4" 12" OPTIONS: GASKET GREY WHITE BLACK MATERIAL: ST STEEL GV GALVANIZED FINISH: B12 WHITE (ST) (OTHER FINISHES AVAILABLE) GV MILL FINISH PERFORATED GASKET INTENDED FOR USE IN SPIRAL OR ROUND DUCT APPLICATIONS (MINIMUM DUCT SIZE 8" (203) MINIMUM NOM. LENGTH IS 10" (254) MAXIMUM NOM. LENGTH IS 36" (914) AVAILABLE SIZE IN 1" INCREMENTS OPEN CELL FOAM INSULATION PROVIDES A TIGHT SEAL AROUND THE GRILLE OPENING IN ANY ROUND DUCT (GREY STANDARD) FACTORY TOLERANCE +/ 1/32" (1) GALVANIZED UNITS ARE MILL FINISH. PROJECT: ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER. ENGINEER: SDGR CUSTOMER: SUBMITTAL DATE: SPEC. SYMBOL: 248720 MAR. 2008 SPIRAL DUCT GRILLE RETURN Copyright E.H.PRICE LIMITED 2008 ECN: SHEET 1 OF 1 REV 0

SDGER - EXTRUDED SPIRAL DUCT RETURN GRILLE Submittal Sheet VARIES WITH DUCT DIAMETER 7/8" (22) STANDARD CONSTRUCTION: FRAMES: EXTRUDED ALUMINUM ALUMINUM PERFORATED FACE NOM. LENGTH - 5/8" (16) DUCT OPENING = NOM. LENGTH OVERALL = NOM. LENGTH + 1" (25) FINISH: B12 WHITE (OPTIONAL FINISHES AVAILABLE) AC CLEAR ANODIZED FASTENING OPTIONS & ACCESSORIES: "A" MOUNTING STANDARD NOTES: NOMINAL LENGTHS AVAILABLE IN 1" INCREMENTS. MIN. NOMINAL LENGTH = 6" MAX. NOMINAL LENGTH = 36" FACTORY TOLERANCE +/- 1/32" (1) -1/4" (6) DUCT OPENING = Available Sizes Duct Dia. Nom. Widths 3 4 6 8 10 12 6 x x 8 x x x 10 x x x x 12 x x x x x 14 x x x x x x 16 x x x x x x 18 x x x x x x 20 x x x x x x 22 x x x x x x 24 x x x x x x 26 x x x x x x 28 x x x x x x 30 x x x x x x 32 x x x x x x 36 x x x x x x 1.000 u1/8" (3) PROJECT: ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER. ENGINEER: CUSTOMER: SUBMITTAL DATE: SPEC. SYMBOL: 249212 SEP 2008 SDGER SPIRAL DUCT GRILLE EXTRUDED RETURN Copyright E.H.PRICE LIMITED 2007 ECN: SHEET 1 OF 1 REV A