TZIF 4. Current-to-Pulse Converter 10/ EN

Similar documents
Electronic alarm signalling unit TES 20. for temperature and standard signals ENA EN

POINTAX 6000L2 Point Recorder

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN

Digital Indicator DS 96/48 PK

Digital Indicator DS 96/24

LINAX 4000L Continuous-line recorder

Rail mounted Temperature Transmitter TH102/TH102-Ex

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

U1601 ENERGY CONTROL SYSTEM

Preset counters, electronic

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

XIOC technology and networking modules

EN 50178, IEC

FieldIT Temperature Transmitter, head mounted TH02/TH02-Ex

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

FieldIT Temperature Transmitter, field mounted TH202/TH202-Ex

DIGEM f 96 x 48 EK. Applications. Description

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

XUA1 - AC Voltage and phase balance relay

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

Electronic Thermostat TE-1 Version according to EN

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Type CP-S, CP-C & CP-A Switch mode

Totalizing Counters mini-i

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

METRATESTER 5+ Tester for DIN VDE /6.15

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Pulse Scaler for DIN Rail Attachment

Technical Information Barrier RB223

Three-phase monitoring relays CM-PFE and CM-PFE.2

J IPC IGBT power converter

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

Online data sheet. CLV601-0D200 CLV60x BAR CODE SCANNERS

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

JUMO Wtrans Receiver with Wireless Data Transmission

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Smart Power Relay E I...

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

KINAX SR 719 Programmable Transmitter for Position Feedback

Coupling Relays and Converters

PFXLM4B01 D * * (1) (2) (3) (4)

XF2 Frequency Relay. Manual XF2 (Revision A)

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

JUMO dtrans T03 J, B, T Analog 2-wire transmitter with digital adjustment. JUMO dtrans T03 BU, TU Analog 3-wire transmitter with digital adjustment

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

For Immediate Delivery call KMParts.com at (866)

CP-T range Product group picture

Multifunctional counter tico 772/773/774

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

This data sheet is only valid in association with the IL SYS INST UM E user manual.

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Adjustable Digital Process Instrument MDK480

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

PHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-f(-SP)

Digital Input Output Module for Zone 1 Series 9470/32

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

RMA42. Technical Information

Electronic timer CT-TGD.22

Controller for the Implementation of a Central or Decentralized Electrohydraulic System

Analog signal converters CC-E I/I

Miniature resistance thermometer Model TR33, thread-mounted

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 350mA 900mA TOP C TOP series

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Transcription:

TZIF 4 Current-to-Pulse Converter Conversion of direct current or voltage signals into a proportional pulse frequency Integration and average value formation of analog signals for quantity counting/remote quantity counting, e.g. for flow rate calculations Digital measured value processing Electromagnetic compatibility Industrial standard to NAMUR recommendation Can be parameterized via the serial interface RS 232 C and parameter definition program TZIKON Drum-type counter and/or digital display (LCD) Output stages passive relay, floating passive optocoupler, floating active transistor Types 19 plug-in card for installation in panel case 19 subrack surface-mounting case, degree of protection IP 20 for wall or top-hat rail mounting to EN 50022

Technical data Functional diagram RS 232C gn T1 C E A D Microprozessor B 24V + external 000000 000000 EEPROM EPROM A U H EN NVRAM LCD Z-17367 Parameterizable input Load-independent direct current 0...20 ma 4...20 ma R E = 50 Ω 0... 5 ma R E = 50 Ω 0...20 ma R E = 50 Ω Max. permitted input current 40 ma Load-independent direct voltage 0...10 V R E 90 kω 0... 1 V R E 90 kω Max. permitted input current 12 V Linear overrange 10 % of basic range Parameterizable range 20 % Output Pulse frequency proportional to input signal Passive pulse output A (relay) Contact output with safe electrical isolation, external counter and power supply Contact load capacity 230 V eff, 5 VA Frequency range 1) 0.0001...1 pulses/s 2) Pulse duty cycle 1 : 1 Pulse duration 10 ms...500 ms Active pulse output B (transistor) Without electrical isolation, internal voltage supply, Highside driver Frequency range 0.0001...50 pulses/s Pulse duty cycle 1 : 1 Pulse duration 3) 10 ms...500 ms Load 180 Ω Output voltage approx. 20 V DC, short-circuit proof Passive pulse output C (optocoupler) With electrical isolation, external counter and power supply Open collector Rating 24 V DC/100 ma Frequency range 0.0001...50 pulses/s Pulse duty cycle 1 : 1 Pulse duration 10 ms...500 ms Load 180 Ω, short-circuit proof Interface Serial RS 232 interface without electrical isolation Signal lines TXD, RXD, GND Baud rate 9600 Bit sequence 1 start bit, 8 data bits, 1 stop bit, 1 parity bit Functions which can be parameterized via the interface Number of pulses and evaluation Physical input variables, e. g. kg/h Electrical input variables, e. g. ma, V Pulse suppression Pulse duration Counter reset Counter start/stop 1) Lifetime without load: 1.6 10 7 operating cycles 2) Recommended: 0.25 pulses/s 3) For the roller register the following applies: pulse duration 50 ms parameterizable range 20 % Page 2 of 7 02.02

Technical data Display LC display Lines 2 Characters/line 8 Character height 4.75 mm 1st line Signal value and parameter data 2st line Dimension Power supply Rated voltage 230 V AC, 115 V AC, 24 V UC, 24 V DC Alternating voltage 15...+10 %; 48...63 Hz Direct voltage 18 V...30 V Residual ripple 20 % within the tolerance range Power consumption Power supply Pulse counter*) without installed 230 V AC 7.2 W 8.1 W 115 V AC 5.3 W 6.3 W 24 V AC 5.3 W 6.3 W 24 V UC 3.7 W 5.7 W 24 V DC 3.7 W 5.7 W *) Pulse frequency 10 Hz Pulse duration 50 ms Characteristics under reference conditions to IEC 770 Calibration error 1) ± 0.1 % Linearity error of A/D conversion 0.2 % Effects Ambient temperature 0.2 %/10 K Power supply 0.1 %/10 % General and safety characteristics Environment conditions 19 - Plug-in card Panelmounting With drumtype counter with LCD Storage/ transporttemperature 30...+ 80 C 10...+55 C 20...+70 C Operating temperature 0...+60 C 0...+50 C 0...+50 C Humidity 95 % r. h. 85 % r. h. 75 % r. h. Condensation not legal Includes class of influence variables to DIN IEC 721-3-2 2K3 DIN IEC 721-3-3 3K3 Mechanical stress Tests to DIN IEC 68 Part 2-27 and Part 2-6 Transport Shock 30 g/18 ms Vibration 10 mm/2 g/...150 Hz In operation Vibration 10 mm/2 g/2...150 Hz Fulfils seismic stress, test class III to DIN IEC 68-3-3, 02.91 for severe and very severe earthquakes. Electrical safety Test to DIN VDE 0411 Part 1/IEC 348 Class of protection 1 Test voltage 2.3 kv power supply against input/output Safe isolation Power supply against signal circuits Signal circuits Functional extra-low voltage with proof isolation to DIN VDE 0100, Part 410 and VDE 0106, Part 101/11.86 with transformer to DIN VDE 0551, Part 1/09.89 Overvoltage category/degree of pollution 2/2 for power supply and signal circuits Electromagnetic compatibility Interference immunity Tested to IEC 801 and VDE 0843 The standard requirements of the NAMUR recommendation are fulfilled. Noise suppression to EN 55011 Connection, case und mounting Electrical connections Interface Degree of protection to DIN 40050 19 plug-in card Panel mounting case 32-pole blade connector to DIN 41612 type D or F Blade connector 6.3 mm or screw terminals for 2.5 mm² 9-pole, socket for D connector Surface mounting case Screw terminals for 2.5 mm² IP 00 IP 20 IP 20 Weight approx. 0.8 kg approx. 1.3 kg approx. 1.4 kg Color RAL 7032 Mounting orientation Arbitrary 02.02 Page 3 of 7

Connection diagrams Connector D 19, IP 20 Connector F 19, IP 20 c d c d a b a b a2 a4 c2 a10 c10 a16 c16 a20 c20 a22 c22 c32 c28 a30 c26 a32 z2 z4 d2 z10 d10 z16 d16 z20 d20 z22 d22 d32 d28 z30 d26 z32 0 0 0 0 B A C KS PE L1 N B A C KS PE L1 N U U Z-17368 a) Input b) Output A... Relay contact B... Transistor output C... Optocoupler KS... Control loope (only with 19 ) c) Grounding d) Power supply *) only with 19 and power supply 24 V DC (compatible pinout for TZIF 3) Standard parameter Measuring point No. Tag description Type Pulse counter Power supply Parameterization Active output Passive output Test default 19 plug-in card without 230 V AC without without output stage A Input TZIF 4 electrical 0...20 ma physical 0...3600 Output TZIF 4 Pulse value (resolution) 1 Pulse count 3600 pulses/h Pulse duration 50 ms Crawl 0 % Page 4 of 7 02.02

Dimensional drawings (Dimension in mm) 19 plug-in card, 8 T (without drum-type counter) 19 plug-in card, 12 T (with drum-type counter) M2,5x10 6,4 3,45 M 2,5 x 10 4,6 3,45 100 128,4 122,5 100 0 0 0 0 0 0 0 0 0 0 0 0 122,5 128,4 169,8 40,34 Z-17369 EN 169,8 3,1 4,6 60,62 (12 T) Z-17370 EN Middle Middle Blade connector 3,1 4,6 Blade connector 2 2 Surface mounting case, type of protection IP 20 Wall mounting (dash-type line: rail mounting) ø55 11 150 164,5 199,7 TS35 144,2 85,3 54 68,5 71,9 16,3 216,1 Z-17446 236,8 Panel mounting case 72 225 187 z d Z-17371 32 144 8 max 40 02.02 Page 5 of 7

Ordering information Catalog No. EUR Deliv. time Current-to-pulse Converter TZIF 4 V18212A- 0 Type of construction Panel-mounting (blade connector type D) 1 452,00 ** 6 wks. 19" plug-in card, blade connector type D 2 303,00 ** 19" plug-in card, blade connector type F 3 303,00 ** Surface-mounting case IP 20 for rail mounting with 19" plug-in card (blade connector D) 4 428,00 ** with 19" plug-in card (blade connector F) 5 428,00 ** For fastening and connections see Suppl. No. 311 and 312 Pulse counter without 0-6-digit, without zero reset 1 105,00 ** 6-digit, with zero reset 2 110,00 ** 8-digit, without zero reset 3 116,00 ** 6-digit, without zero reset, with digital display (LCD) 1) 4 188,00 ** 6-digit, with zero reset, with digital display (LCD) 1) 5 193,00 ** 8-digit, without zero reset, with digital display (LCD) 1) 6 193,00 ** with digital display (LCD) 2) 7 83,00 ** Power supply 230 V AC 1-115 V AC 2-24 V AC 3-24 V UC 4 75,00 ** 24 V DC (without electrical isolation) 5 9,00 ** Parameterization without (standard parameters) 1 - according to customer specification 2 - Active output without 0 - output stage B (transistor) 3) 1 35,00 ** Passive output without 0 - output stage A (Relay) 1 36,00 ** output stage C (optocoupler) 2 53,00 ** The Catalog No. must be supplemented with Code-Nos. 1) For display of measured values and parameters 2) For 8-digit count value, measured value and parameter display 3) Always necessary if drum-type counter is installed Page 6 of 7 02.02

Additional ordering information Code EUR Deliv. time Measuring point No. (16 digits) V01 - Electrical input variable: 1) lower range (2 digits, 4 decimals) V51 - upper range (2 digits, 4 decimals) V52 - unit ma yes/no (clear text) V55 - V yes/no (clear text) V56 - Physical input variable: lower range (6 digits, 2 decimals) V61 - upper range (6 digits, 2 decimals) V62 - unit (8 digits) (clear text) V63 - Output: 2) (0,3...180.000 pulses/h ) (8 digits) V64 - Pulse duration: 3) (10...500 ms) (4 digits) V65 - Suppression: (up to 50 % of physical span) (2 digits, 1 decimal) V68 - Fasteners for wall mounting (surface-mounting case IP 20) 311 14,00 ** Srew terminal connection (panel-mounting case) 312 15,00 ** Label: insert plate 4) (clear text) 381 6,50 ** adhesive label 1st line (clear text) 382 6,50 ** 2nd line (clear text) 383 6,50 ** 3rd line (clear text) 384 6,50 ** Operating manual (indicate total number of copies)...german (for 1 copy no entry) Z2D 9,50...English (Code-No. always required) Z2E 9,50...French (Code-No. always required) 42/18-49-3; 42/18-49-1 XL Z2F 9,50 Catalog No. Code EUR Deliv. time Parameter definition program TZIKON (3 1/2"-diskette, 1,44 MB) 18295-4-0346070 83,00 ** RS 232 C extension cable 11492-4-0743305 30,00 ** 1) Measuring range > 20 % of basic measuring range <110 % of basic measuring range 2) max. 3600 pulses/h for relay output A, max. 36.000 pulses/h for mechanical pulse counter 3) Pulse duration < 50 ms for drum-type counter 4) not in combination with digital display Notice Data for Code-Nos. V51...V68 are required for customer-specific parameter definition. If not available, standard parameters will be defined. 02.02 Page 7 of 7

ABB Automation Products GmbH Borsigstrasse 2 D-63755 Alzenau Phone +49(0)60 23 92-33 13 Fax +49(0)60 23 92-32 10 http://www.abb.com Subject to technical changes. Printed in the Fed. Rep. of Germany Data Sheet 02.02