Instruction Manual Model 4116-T51 Multi-Band Translator

Similar documents
Instruction Manual Model Ka-Band Block Upconverter

Instruction Manual Model 4116-T300 Ka-Band Block Translator

Instruction Manual Model Block Translator

Instruction Manual Model

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model M Switch, DPDT, Manual Select

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model Upconverter

Instruction Manual Model Upconverter

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

DDS-PLL SYNTHESIZER DPL-2.5GF USER S MANUAL DIGITAL SIGNAL TECHNOLOGY, INC.

GM8036 Laser Sweep Optical Spectrum Analyzer. Programming Guide

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

Ku-Band VSAT Block Up Converters

KU-BAND OUTDOOR BLOCK CONVERTERS

C-Band VSAT Block Up Converters

Model 1791 VHF Radio User's Manual

PI-10 Broadband Power Indicator

PI-150 Broadband Power Indicator

SMACSM Frequency Agile Pilot Carrier Redundancy Source

MICROWAVE FREQUENCY SYNTHESIZER QP-FSPLL USER MANUAL

Additional JFW Brochures

MC108A-2 RF MULTI-COUPLER USER S GUIDE


Ideal for high dynamic range measurements from compression to noise floor

RF Wireless Serial Device Server

SAT SCD/ARGOS INSTRUCTION MANUAL

C-Band Redundant LNA Systems

X-Band Redundant LNA Systems

Model 1792 VHF Radio. User s Manual. Rev. B FAA APPROVED NOT FAA APPROVED. ECP Dec 30

DAA AES/EBU Digital Audio Distribution Amplifier. User Manual. I.R.T. Communications Pty Ltd

VSAT Redundant System Solutions

SDI SPECTRADYNAMICS, INC GHZ RUBIDIUM FREQUENCY SYNTHESIZER OPERATING MANUAL

Model Remote Programmable Up to 8 Channel Low Noise Differential Preamplifier. Operating Manual

MultiNet. Instruction Manual. Digital Energy Multilin. Serial to Ethernet Converter. Manual P/N: A2 Copyright 2009 GE Multilin

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

Advanced Test Equipment Rentals ATEC (2832)

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

NTS-4000-S. NTS-4000-S Installation and Configuration Manual TEL: +44 (0) FAX: +44 (0) galleonsupport.

Block Upconverters for Integration in High Power Amplifiers

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

3100LA Broadband Power Amplifier

Instruction Manual Model 2007/2007R Noise Source

GPS Time and Frequency Reference Receiver

SIR-4011 MICROWAVE WIDEBAND DSP RECEIVER. WIDE FREQUENCY RANGE: GHz

NTS-6002 VERSION 11 HARDWARE MANUAL

[ tima-datasheet-en v11.1 ]

PYRAMID 915MHZ WIRELESS RF TRANSMITTER & REPEATER USER GUIDE. Table of Contents. Overview Installation Setup Specifications...

MPR kHz Reader

SAT ARGOS INSTRUCTION MANUAL

50 Ohm Components Brochure

PCX-7401 Pulsed Current Source Operation Manual

LincView OPC USER GUIDE. Enhanced Diagnostics Utility INDUSTRIAL DATA COMMUNICATIONS

INSTRUMENTS, INC. Models 2960AR and 2965AR Disciplined Rubidium Frequency Standards. Section Page Contents

AW5800-SPEC USER S MANUAL

Signal Forge 1800M Frequency Expansion Module. 1.0 GHz to 1.8 GHz. User Manual

AES 7705i MultiNet Receiver System Initial Installation and Setup Guide

Signal Forge 2500M Frequency Expansion Module. 1.5 GHz to 2.6 GHz. User Manual

AW900-SPEC USER S MANUAL

Modular Metering System ModbusTCP Communications Manual

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY SYNTHESIZER LNFS-400 OPERATING MANUAL

USER'S MANUAL. Model : K

2100L Broadband Power Amplifier

EPSILON SWITCH & AMPLIFIER SYSTEM SAS-E MODEL SAS17E & SAS36E. User s Manual. spectracom.com

INSTALLATION & OPERATING INSTRUCTIONS

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

About JFW Industries, Inc.

SPM-50 RF Spectrum Power Meter PC Software User Manual

Agilent 2-Port and 4-Port PNA-X Network Analyzer. N5241A - 10 MHz to 13.5 GHz N5242A - 10 MHz to 26.5 GHz Data Sheet and Technical Specifications

Connecting Mains Electrical Power

A 500 Broadband Power Amplifier

MFJ ENTERPRISES, INC.

RM600 Carrier Grade E1 Radios

Quick-Start Guide. M7 Series DATA RADIO MODEM

Copyright Teletronics International, Inc. Patent Pending

Keysight 2-Port and 4-Port PNA-X Network Analyzer

Features. Description. General Specifications. VS Series Inclinometer : Dual Axis, RS232 and Analogue Output

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM

Current Probe Fixture Instruction Manual

Trio Q Data Radios. Licensed UHF Ethernet and Serial Data QR450

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

Advanced Test Equipment Rentals ATEC (2832)

DVB-T/H Portable Test Transmitter

Parameter Value Unit Notes

1140LA Broadband Power Amplifier

Data Acquisition Modules/ Distributed IO Modules

FRYCORDER Power Cord Burn-in Generator

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

GPSR400 Quick Start Guide

Connecting the Radio:

MDS SD4 Software-Controlled Digital Communications Firmware Release 1.x.x

WIEG4PRT-A Four port Wiegand to RS232 Converter.

MFJ ENTERPRISES, INC.

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

Digital Lighting Systems, Inc.

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

CL4424. Industrial 2.4GHz ConnexLink. User s Manual Version 1.1

Transcription:

Instruction Manual Model 4116-T51 Multi-Band Translator Weather Resistant Unit March 2015, Rev. F Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. Printed in USA. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com

INSTRUCTION MANUAL MODEL 4116-T51 Multi-Band Translator, Weather Resistant* TABLE OF CONTENTS PAGE Warranty 2 1.0 General 3 1.1 Equipment Description 3 1.2 Technical Characteristics 4 2.0 Installation 5 2.1 Message Protocol 5 2.2 M&C Commands 6 2.3 M&C Queries 7 2.4 Ethernet Interface Installation 9 2.4.1 Methods of Connection 9 2.4.2 Ethernet Configuration 9 2.4.3 Webpage M&C 10 2.4.4 SNMP Configuration 11 2.5 Translator Outline Drawings 14 2.6 Physical Interface 15 2.7 Installation/Operation 16 3.0 Environmental Use Information 18 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc. s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc. s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com 4116-T51 Manual, Rev. F Page 2 03/16/15

MODEL 4116-T51 Multi-Band Translator, Weather Resistant* 1.0 General 1.1 Equipment Description The 4116-T51 Multi-Band Block Translator converts one of three input RF bands to one of three output RF bands. Front panel LEDs provide indication of DC Power, and PLL Alarm. The RF to RF gain is +20 db, maximum. Connectors are Type N female for the RF out, RF in and RF in Monitor and SMA female for the external reference input and reference output. Gain, band select, and internal 10 MHz frequency are controlled by the Ethernet M&C or via the Status/Control Connector. The 10 MHz reference switches to internal when the external falls below +1 dbm.the 4116-T51 is powered by a 100-240 ± 10% VAC power supply, and mounted in a 8 Wide X 6 High X 16 Deep, Weather Resistant* Enclosure. (NOTE: *Weather Resistant enclosures are designed to be water resistant for installation in an outdoor enclosure/antenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges. They are designed to be located out in the elements (water, sleet, snow, etc.) but they are not designed to be submerged under water. If an extended temperature range is required, there is an Extended Temperature option (Option W21; -30 C to +60 C) available at an additional cost. Contact Cross for quote. STATUS / CONTROL ETHERNET...... J6 J7 CROSS TECHNOLOGIES INC. POWER AC IN J8. FUSE F1 MODEL 4116 MULTI-BAND TRANSLATOR ALARM RF INPUT RF MON 10M IN 10 M OUT RF OUT J1 J2 J3 J4 J5 Model 4116-T51 Multi-Band Translator Front Panel +10 RF MON SPL C2-30 to-10 In 5.85 to 6.95 or 13.75 to14.85 or 17.30 to 18.40 GHz RF In COMBINER 2.05 to 3.05 GHz 5.1 to 5.6 & 6.6 GHz 3.4 to 4.5 GHz BP 10.7 to 11.8 GHz BP 11.7 to 12.8 GHz BP C O M B I N E R V A R A T T 4116-T51 Translator Block Diagram -60 to 0 Out 3.4 to 4.5 or 10.7 to11.8 or 11.7 to 12.8 GHz RF Out FIGURE 1. Model 4116-T51 Multi-Band Block Translator Block Diagram 4116-T51 Manual, Rev. F Page 3 03/16/15

1.2 Technical Characteristics TABLE 1.0 4116-T51 Multi-Band Block Translator Specifications** Input Characteristics Impedance/Return Loss Frequency (GHz) 50Ω/14 db Band 1-5.85 to 6.95 Band 2 & 3-13.75 to 14.85 Band 4 & 5-17.3 to 18.4 Noise Figure, Maximum Input Level Input 1 db Compression Output Characteristics Impedance/Return Loss Frequency (GHz) Output Level Range Output 1 db Compression 20 db maximum gain -30 to -10 dbm 0 dbm 50Ω/14 db Band 1-3.4 to 4.5 Band 2 & 4-10.7 to 11.8 Band 3 & 5-11.7 to 12.8-60 to 0 dbm +10 dbm Channel Characteristics Gain Input to output isolation Spurious, Inband Spurious, LO Spurious, LO Intermodulation Frequency Response Frequency Sense LO Characteristics LO Frequency Frequency Accuracy 10 MHz Level +20 ±3 db, (+20 to -40 db variable in 0.5 db steps) < 60 db, minimum > -50 dbc in band, -15 to 0 dbm out <-60 dbm LO <-50 dbm measured at the input; <-25 dbm, measured at the output <-50 dbc for two carriers each at -5 dbm out ± 2 db, over RF band; ± 0.5 db, 40 MHz BW Non-inverting Band Specific ± 0.05 ppm max. over temp internal reference; external reference input Input = +2dBm to +8 db in; Monitor Output = input level ± 0.5 db, 50Ω Phase Noise @ Frequency Hz 100 1K 10K 100K 1M dbc/hz -70-80 -85-100 -110 continued on page 5... 4116-T51 Manual, Rev. F Page 4 03/16/15

M&C Commands (continued) Other RF Out, RF Mon. Connector L-Band Connector 10 MHz Connectors Weather Resistant* Connectors Size Power Type N (female), 50Ω Type N (female), 50Ω SMA (female), 50Ω **+10 C to +40 C; Specifications subject to change without notice. Status/Control Connector, MS3112E14-18S; Mating Cable Connector, MS3116F14-18P. Ethernet Conector, RJF21B; Mating Cable Connector, RJF6G; Cable interface, Standard RJ45. AC Input Connector, Clipper Series, CL1M1102, Mating Cable Connector, CL1F1101. (Unless otherwise specified, the mating connector is provided preassembled onto a standard NEMA 5-15 U.S. power cord.) 8 Wide X 6 High X 16 Deep, Weather Resistant* Enclosure 100-240 ±10% VAC, 47-63 Hz, 25 Watts Maximum, FCI Clipper Series CL1M1102, Weather Resistant* Connector. 4116-T51 Manual, Rev. F Page 5 03/16/15

2.0 Installation The 4116-T51 Multi-Band Block Translator consists of a 8 W X 6 H X 16 D Weather Resistant* enclosure. A switching, ± 12, +24, +5 VDC power supply provides power for the internal assemblies. The 4116-T51 can be secured to a mounting plate using the 4 holes on the bottom of the front and rear panels. See Figure 2.5 for mounting dimensions. 2.0.1 Connection to AC Input Power The 4116-T61 is furnished with a pre-assembled AC power input cable as described below. 4115-31 Power Input Connector, FCI Clipper Series, CL1M1102 & Crimp Pins Mating Connector FCI Clipper Series, CL1F1101, Crimp Pins and CL101021 Backshell Pin Input Connector Pin Description 1 100-240 ±10% VAC, 47-63 Hz, 20 watts max. 2 Neutral 3 Ground 2.1 Message Protocol The serial format for the RS232/RS422/RS485 port is 9600 baud, 8 data bits, no parity, and 1 stop bit. All messages consist of ASCII printable characters so standard terminals and terminal emulator programs may be used to control and monitor the unit. All messages begin with the open bracket character } (ASCII 0x7B) and end with the close bracket character } (ASCII 0x7D). Messages consisting of commands to set or change operating parameters and modes of the unit begin with C (ascii 0x43) followed by a command specific character. Messages consisting of queries to report operating parameters and modes begin with S (ASCII 0x53) followed by a parameter specific character. M&C Commands The following tables summarize the commands and status queries applicable to the 4116-T51 Multi-Band Block Translator. * PLEASE NOTE: The two character {aa} prefix, shown in the table below, is present ONLY when RS485 is selected. 4116-T51 Manual, Rev. F Page 6 03/16/15

Table 2.0 Model 4116-T51 M&C Commands Table 2.0: Model 4116-T51 M&C Commands Command Syntax Description Set Frequency Band {aacbx} x = 1 to select band 1: in = (5850 to 6950 MHz) out= (3400 to 4500 MHz) x = 2 to select band 2: in = (13750 to 14850 MHz) out = (10700 to 11800 MHz) x = 3 to select band 3: in = (13750 to 14850 MHz) out = (11700 to 12800 MHz) x = 4 to select band 4: in = (17300 to 18400 MHz) out = (10700 to 11800 MHz) x = 5 to select band 5: in = (17300 to 18400 MHz) Out = (11700 to 12800 MHz) Set Frequency Offset {aacfxxxxx} where: xxxxx = 5 characters if Band 1 is selected, Range: -0400 to +0600 in 5 MHz steps if Band 2 is selected, Range: 00000 to -1000 in 5 MHz steps if Band 3 is selected, Range: 00000 to +1000 in 5 MHz steps if Band 5 is selected, Range: 00000 to -0500 in 5 MHz steps Set Gain {aacgxxxx} where: xxxx = 4 characters Range: -400 to +200 (-40.0 to +20.0 in 0.5 db steps) Set Serial Interface {aacix} where: x = 0 to select RS232 x = 1 to select RS422 x = 2 to select RS485 Set Mute {aacmx} where: x = 1 to mute the output x = 0 to unmute the output continued on page 8... 4116-T51 Manual, Rev. F Page 7 03/16/15

2.3 M&C Queries Command Set RS485 address Table 2.0 Model Syntax4116-T51 M&C Description Commands (Continued from page 7) {aacrxx} where: xx = 2 characters Range: 00 to 31 Set Int. 10 MHz reference offset {aacoxxxxx} where: xxxxx = 5 characters Range: +2000 to -2000 Table 2.1 Model 4116-T51 M&C Commands Table 2.1: Model 4116-T51 M&C Queries Command Frequency Band Gain 10 MHz reference Frequency Offset Syntax {aasb} {aasg} {aase} {aasf} Description Returns {aasbx} where: x = 1 if selected band is 1: in = (5850 to 6950 MHz) out = (3400 to 4500 MHz) x = 2 if selected band is 2: in = (13750 to 14850 MHz) out = (10700 to 11800 MHz) x = 3 if selected band is 3: in = (13750 to 14850 MHz) out = (11700 to 12800 MHz) x = 4 if selected band is 4: in = (17300 to 18400 MHz) out = (10700 to 11800 MHz) x = 5 if selected band is 5: in = (17300 to 18400 MHz) out = (11700 to 12800 MHz) Returns {aasgxxxx} where: xxxx = 4 characters Range: (-400 to +200 in 0.5 db steps) Example: {aasg-245} indicates that the current gain setting is -24.5 db Returns {aasex} where: x = 1 if Internal 10 MHz reference is selected x = 2 if External 10 MHz reference is selected x = 3 if Auto 10 MHz reference is selected Returns {aasfxxxxx} where: xxxxx = 5 characters if Band 1 is selected, Range: -0400 to +0600 in 5 MHz steps if Band 2 is selected, Range: 00000 to -1000 in 5 MHz steps if Band 3 is selected, Range: 00000 to +1000 in 5 MHz steps if Band 5 is selected, Range: 00000 to -0500 in 5 MHz steps continued on page 9... 4116-T51 Manual, Rev. F Page 8 03/16/15

Table 2.1 Model 4116-T51 M&C Commands (continued from page 8) Command Serial Interface Syntax {aasi} Description Returns {aasix} where: x = 0 if RS232 is selected x = 1 if RS422 is selected x = 2 if RS485 is selected RS485 address {aasr} Returns {aasaxx} where: xx = 2 characters Range: 00 to 31 {aasm} Returns {aasmx} where: x = 0 if mute is off x = 1 if mute is on Int. 10 MHz reference offset {aaso} Returns {aasoxxxxx} where: xxxxx = 5 characters Range: +2000 to -2000 Unit Status {aasa} Returns {aasaxy} where: x = 0 if no summary alarm, x = 1 if summary alarm y = 0 if unit is using internal 10 MHz ref, y = 1 if unit is using external reference Internal Temperature {aast} Returns {aastxxx} where: xxx = 3 characters Range (-99 to +99) degrees Celsius Model and firmware revision {aasv} returns {aasvxxxxxxxxyyyy} where: xxxxxxxx = unit model number yyyy = unit firmware rev. 4116-T51 Manual, Rev. F Page 9 03/16/15

2.4 ETHERNET Interface Installation and Operation The 4116-T51 Multi-Band Translator is equipped with a 10/100 Base-T compatible Ethernet interface for control and monitoring of its operating parameters. An HTML script interface allows the user to monitor and control the converter using a standard web browser. SNMP (Simple Network Management Protocol) is also supported. Contact Cross Technologies for the SNMP MIB file. 2.4.1 Methods of Connection Directly Connected to a PC: For control from a local PC, attach the 4116-T51 s Ethernet port to the Ethernet network connector on the PC using a crossover RJ-45 cable. LAN Connection For LAN connections, attach the 4116-T51 Ethernet port to the LAN using a normal RJ-45 cable. Use any PC on the LAN to connect to the 4116-T51. 2.4.2 Ethernet Configuration Each 4116-T51 must be configured with an appropriate IP address, Netmask, and Gateway assigned by your network manager. The 4116-T51 is set at the factory with a static address that is written on a tag attached to the unit. The device server in the 4116-T51 has a built in HTTP based configuration manager that is used to configure network settings. To access the configuration manager open a web browser and enter the IP address of the 4116-T51 in the browser's address field. The window shown in Figure 2-A will appear. As delivered, there is no password set. Choose your user name and password here or leave those fields blank and click OK to proceed to the configuration manager webpage. Figure 2-A: Password Screen 4116-T51 Manual, Rev. F Page 10 03/16/15

Figure 2-B: Configuration Manager Screen In the left frame of the configuration manager click on Network to display the Network Settings screen. Enter the IP address, Subnet mask, and Gateway address with delimiter dots (example: 192.168.192.47). 2.4.3 Webpage M & C Enter the following address in a web browser to access the M & C webpage: http://<ip address of 41xx>/serial/0/setup.htm where <ip address> is the IP address of the unit. Figure 2-C (page 11) shows the webpage from a model 4116-T51 frequency converter. 4116-T51 Manual, Rev. F Page 11 03/16/15

Figure 2-C: Model 4116-T51 Web page 2.4.4 SNMP Configuration Setting of SNMP parameters such as Community Write and Community Read strings requires a Telnet connection to port 9999. The following instructions explain how to establish such a Telnet connection using Windows XP's Hyper Terminal utility. Start the Hyper Terminal application and select New Connection from the File drop down menu. The next screen is a Connect To dialog box. Select TCP/IP (Winsock) from the Connect drop down menu. Enter the IP address of the 4116-T51 in the Host address: field and 9999 in the Port number field. Figure 2-E shows an example of the Hyper Terminal settings required to access the SNMP configuration menu. 4116-T51 Manual, Rev. F Page 12 03/16/15

Figure 2-E: Telnet Settings in Hyper Terminal Once the Telnet connection is established you will be prompted to Press Enter for Setup Mode. Press enter and a menu of device server configuration options will appear (see Figure 2-F). Select menu item 3, SNMP configuration. You will be prompted to enter SNMP community read and write strings. After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps. You must enter at least one and up to four IP addresses of SNMP managers that will access the unit. This is required even though SNMP traps are not implemented. The unit will not process SNMP SET and GET requests from an SNMP manager unless the IP address associated with that manager is entered in the device server. 4116-T51 Manual, Rev. F Page 13 03/16/15

Figure 2-F: Device Server Configuration Menu 4116-T51 Manual, Rev. F Page 14 03/16/15

Figure 2.5 Front panel input and output connections, overall dimensions and base plate mounting dimensions. 7.88 6.62 4.2 STATUS/CONTROL CONNECTOR Weatherized MS3112E14-18S 18 pin connector. (See Table 2.6) ETHERNET CONNECTOR Weatherized Standard RJ45 Ethernet Connector. RF INPUT Type N (female) 50Ω Band 1-5.85-6.95 GHz Band 2&3-13.75-14.85 GHz Band 4&5-17.3-18.4 GHz STATUS / CONTROL ETHERNET...... J6 J7 CROSS TECHNOLOGIES INC. MODEL 4116 MULTI-BAND TRANSLATOR RF INPUT J1 RF MON J2 10M IN J3 POWER ALARM 10 M OUT J4 AC IN J8 RF OUT J5. FUSE F1 POWER IN AC input 100-240 ±10% VAC 47-63 Hz., 25 watts max. Weatherized CL1M1102 Connector POWER LED Lights GREEN when DC voltage is present from AC power supply. Fuse 1A/250V - 1.25 X.25 slow blow. ALARM LED Red LED indicates upconverter alarm. RF OUTPUT Type N (female) 50Ω Band 1-3.4 to 4.5 GHz Band 2&4-10.7-11.8 GHz Band 3&5-11.7-12.8 GHz 5.500 5.775 RF MONITOR Type N (female) 50Ω -20 to ±2dB RF Output. 10MHz INPUT SMA (female) 50Ω Insert External 10MHz) Reference here (+2 to +8 dbm). 10MHz OUTPUT SMA (female) 50Ω input level ±0.5 db. 1/4-20 Tapped Thru, 4 Places 12.00 15.5 15.875 7.50 4116-T51 Manual, Rev. F Page 15 03/16/15

2.6 Physical Interface All 4115 and 4116 units provide a RS232/RS422/RS485 interface port and a 10/100 Base-T Ethernet port. Both ports are available when the unit is installed and powered up. Commands may be sent to either port at any time and they will be processed in the order that they are received. The RS232/RS422/RS485 signals connect via an 18-pin, MS3112E14S connector as shown in Figure 2.5. The Ethernet signals connect via a standard RJ45 connector. Part #RJF6G. Table 2.6.1: Monitor and Control Connector Monitor and Control Connector Pinout Mating Connector part number MS3112E14-18S Mating Cable Connector part number MS3116F14-18P Pin Signal Description A Chassis Ground N Summary Alarm Normally Closed P Summary Alarm Common R Summary Alarm Normally Open E RS422/RS485 Data Out- F Signal Ground C RS422/RS485 Data In- D RS422/RS485 Data Out+, RS232 Data Out B RS422/RS485 Data In+, RS232 Data In NOTE: Planning Ethernet Access It is recommended that IP knowledgeable customer personnel be consulted as a resource in the installation and use of the Ethernet access features of the Cross Technologies product. 4116-T51 Manual, Rev. F Page 16 03/16/15

2.7 Installation/Operation Installing and Operating the 4116-T51 Multi-Band Block Translator 1. Connect a -30 dbm to -10 dbm signal to RF INPUT, J1 (Figure 2.5). 2. Connect the RF OUTPUT, J5 (Figure 2.5) to the external equipment. 3. Using the pre-assembled AC power input cable (furnished), connect 100-240 ±10% VAC, 47-63 Hz to AC IN connector on the front panel. 4. If a custom length power cable must be made, refer to description below for connections.* 5. Be sure DS1 (green, DC Power) is on and DS2 (red, Alarm) is off (Figure 2.5). 6. Set the gain so that the output level is always within the range -60 to 0 db (See Table 2.0). 7. Select either INT (for internal 10 MHz ref), AUTO (for internal 10 MHz ref UNLESS a external 10 MHz, +2 to +8 dbm signal is connected to J2), or EXT (for external 10 MHz, +2 to +8 dbm ref. that is inserted at J2) via Ethernet or serial command. 8. Check that a 10 MHz, signal is present at the 10 MHz REF OUTPUT at the same level as the input, ±0.5 db (J4 - Figure 2.5). 9. AC Fuse - The fuse is a 1A/250V 1.25 x.25 (slow blow) and is inserted in the fuse F1 position. NOTE: If a fuse continues to open, the power supply is most likely defective. 4112-T51 AC Power Input Connections Connector, Clipper Series, CL1M1102 and crimp pins Mating Connector, Clipper Series, CL1F1101 and crimp pins Pin Input Connector Pin Description 1 100-240 ±10% VAC, 47-63 Hz, 20 watts max. 2 Neutral 3 Ground Unless otherwise specified, the mating connector is provided preassembled onto a standard NEMA 5-15P U.S. power cord. 4116-T51 Manual, Rev. F Page 17 03/16/15

CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com Printed in USA 4116-T51 Manual, Rev. F Page 18 03/16/15