MGA Magnetic field system. DC khz

Similar documents
Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

Coils Loop sensors / radiating loops / Helmholtz coils

Schlöder GmbH - EMC Test and Measurement Systems Model #

EMC TEST SYTEMS / INSTRUMENTS AND CONTROL SOFTWARE

Loop & Magnetic Field Coil

Surge Generator for MIL-STD 1275

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

GF 467F FUNCTION GENERATOR. PROTECTED RS232 + (USB OR LAN)* LabVIEW 0,01 Hz to 5 MHz CMos. Specifications. Other specifications

Coupling / decoupling network (CDN) for screened or coaxial cables

LVA series of 4-Quadrant amplifiers

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

Microphones & Accessories

RADIATED IMMUNITY TEST SYSTEMS

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

We re In The Business Of Making Your Life Easier

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

CS114 + CS115 + CS116

Voltage Transient Emission Test

Coupling/Decoupling Networks (CDN)

LVA 4-Quadrant Amplifier 1000

Flexible AC current probes

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

MONITORING DEVICE 4 khz to 400 MHz

Appendix A: Specifications

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

Fluke Norma 4000/5000

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

DECLARATION OF CONFORMITY

A E 4-quadrant voltage and current amplifier DC 1 MHz 100 V/µs 500 W (source) 150 W (sink) DATA SHEET

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DS10000ULFS-10V/10kA

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

Noise Excitation Equipment for Building Acoustics Measurements Loudspeaker Systems Nor275 and Nor276 Power Amplifier Nor280 Tapping Machine Nor277

A QE 4-quadrant voltage and current amplifier DC 1 MHz 100 V/µs 1000 W (source) 650 W (sink) DATA SHEET

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.


APS series of 4-quadrant amplifiers

Nº32 REFERENCE PREAMPLIFIER

A A 4-quadrant voltage amplifier DC 1 MHz 100 V/µs 500 W (source) 90 W (sink) DATA SHEET

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies

Wide-band Models from DC to 100 MHz

Advanced Test Equipment Rentals ATEC (2832)

Wide-band Models from DC to 100 MHz

LVA 4-Quadrant Amplifier 5000

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

DC MHZ PXI Differential Instrumentation Amplifier

Model 865 RF / Ultra Low Noise Microwave Signal Generator

Variable-Gain High Speed Current Amplifier

PRODUCT DATA. 16-channel DeltaTron Conditioning Amplifiers Types 2694-A/B/C/D. Features and Uses

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

TPS TRANSDUCER POWER SUPPLY & LEM IT CURRNET TRANSDUCER

PM 6669 High-Precision Frequency Counter Specifications

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

SPECIFICATION. Online UPS 3000VA

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

DC Current Transducers CT-200 CT-300 CT-400 User s Manual All Rights Reserved CAEN ELS d.o.o. Rev. 1.0 November 2014

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

CX1100 Series Current and Differential Sensors

World-Class Accuracy & Measurement Range (40 Conventional Models)

The Ins and Outs of Audio Transformers. How to Choose them and How to Use them

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

Chino Scientific Instruments Manufacturing

Coupling/Decoupling Networks (CDN)

Ultra Low-Noise Variable Gain Low-Frequency Voltage Amplifier

Kaskode One Phono Preamplifier Owner s Manual

CS101. Conducted Susceptibility CS101. CS101 Maximum Current. CS101 Limits. Basis For CS101 Limits. Comparison To MIL-STD Vdc or Less

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM

Racal Instruments 4152A. 6.5 Digit Digital Multimeter. Product Information

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

Wide-band Models from DC to 100 MHz

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

Type Ordering Code Package TDA Q67000-A5168 P-DIP-18-5

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

R&S ZV-Z5x Calibration Units Specifications

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

MCTS II Multi Channel Current Transducer System. Installation Manual

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

Model 6517B Electrometer / High Resistance Meter Specifications

LOW NOISE AMPLIFIER SA SERIES

PRECISION CURRENT TRANSDUCERS. DC Current Transducers CT-100 CT-150. User s Manual. All Rights Reserved CAEN ELS d.o.o. Rev. 1.

NI PXI-4461 Specifications

R&S ZV-Z5x Calibration Units Specifications

ULTRASTAB IHF Precision Current Transducer

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

5000 Series Receiver Systems

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

Green LED (right of 'D' type connector)

ULTRASTAB I U Precision

Low Frequency Measuring System

Transcription:

MGA 1030 Magnetic field system DC - 250 khz EN 55103-1 + 2, EN 61000-4-8, Automotive, MIL-STD a.o. Generation and measurement of magnetic fields from DC up to 250 khz Field strengths up to 1000 A/m Additional Sensor coils, Helmholtz coils, Test adapter Introduction The compact magnetic field generator and analyzer MGA 1030 allows susceptibility tests against magnetic fields from DC up to 250 khz according the standard EN 55103-2 (product standard for professional audio, video and light control techniques) and there measurement according to EN 55103-1. In combination with our triaxial Helmholtz coils full automated susceptibility tests are possible at magnetic field strength up to 1000 A/m for frequencies from DC to 1 khz. Lower field strength can be generated for frequencies up to 250 khz. Due to the triaxial set-up of our Helmholtz coil major improvement in device handling is achieved because there is no need to turn an EUT during tests. The MGA 1030 complies to all magnetic field requirements of relevant EMC and military standards. More EMC tests are possible according the standards below: - IEC / EN 61000-4-8 - SAE J 1113-2, SAE J 1113-22 - GM W 3097 - ISO 11452-8 - Ford ES-XW7T-1A278-AC - MIL-STD-461 E/F RS 101, CS101 - PSA B21 7110 - DC 11224, DC 1014 - and similar standards Furthermore magnetic field measurements acc. MIL-STD-461 E/F RE101, CE101 are possible Tests and measurements are controlled by a program which will set most parameter automatically. For any relevant standard, which are fulfilled by the MGA 1030, limit values are already included into the software package, although any different value can be defined by a user. After every test full reports will be created automatically. Report layout is pre-defined, though any user-defined layout is possible. High performance is guaranteed by a self-calibration process which utilizes an internal source as reference. Technical data may be changed without notice Benefits Components MGA 1030 consists of three independent module: a signal generator (DC 250 khz), a power amplifier (800W output maximum, DC 1MHz bandwidth) and spectrum analyzer (16 Bit, 1 MSPS sampling rate). All modules can be used as stand-alone units. Software Any function is controlled via an application which also guide the user through any test or measurement. Adaptation of signal strength or measurement graphs are possible at any stage. User defined signals complement the usage for fast and reliable tests. The application software is written in LabVIEW which guarantees stable and fast performance on any Microsoft Windows platform S c h l ö d e r G m b H Hauptstr. 71, D - 75210 Keltern-Weiler +49-7236/ 9396-0 +49-07236/ 9396-90 email: info@schloeder-emv.de Internet: www.schloeder-emv.de

Additional equipment Our company also provides many different coils and loop sensors which are ideally suited for the described tests. Not only our own equipment can be used with the MGA 1030, but also user defined coils. A calibration mode is included in the software to complement the magnetic test system with any further equipment. Self-calibration Using an ultra-stable voltage source self-calibration correction values are stored in an internal EEPROM. Any voltage signal or voltage measurement device is calibrated as a self-calibration process automatically in about a minute. Applications Automotive Testing Intensive testing is required for new products which should be used in any automotive application. The MGA 1030 allows fast and easy testing according to many automotive standards as described before. Magnetic Field Generation MGA 1030 enables a user to generate strong magnetic fields up to 1000 A/m. Even alternating fields up to 250 khz can be generated by the magnetic test system Technical Data - MGA 1030 Magnetic Test System MGA 1030 Voltage input (Analyzer) Input impedance Connector Max. input voltage Gain Current input Shunts Max. input current DC - 250 khz 1 MΩ / 50 Ω switchable XLR, unbalanced 100 V continuous (attenuator autoset at overvoltage) 10 V at 50 Ω -20/0/20/40 db Preamplifier 0/20 db ADC Amplifier Self-calibration with ultra stable on-board reference DC - 250 khz 10 mω / 1 Ω / 100 Ω 20 A continuous (overload protection) 1 Ω and 100 Ω shunt are protected by an additional 1.5 A fuse Connector 4 mm safety jack (+, -) measurement via insulation amplifier or input jacks Measurement range AD converter Resolution Sampling rate Aliasingfilter 20 A, 10 A, 1 A, 100 ma, 10 ma, 1 ma automatic offset and gain Self-calibration with ultra stable on-board reference 16 Bit 1.0 MSPS 0.01dB Tschebyscheff filter, fg = 260 khz; filter may be switched off 241309 Seite 2 von 8

Technical Data - MGA 1030 (continuation) Generator Output impedance Connector Signal Amplitude Resolution Amplifier Connector Current Voltage DC - 250 khz 50 Ω BNC, unbalanced Sine wave / square wave / triangular / DC 0 10V AC, -10V - +10V DC 12 Bit (2.5 mv) Switchable -20 db Attenuator Self-calibration with ultra stable on-board reference DC - 1MHz 4mm safety jacks (output) BNC, unbalanced (input) 5Arms / 16Arms (MGA1030-05 / MGA1030-16) 50Vrms / 75 V DC Magnetic Test System MGA 1030 Distortion (DC 100 khz, load 0.10% Gain 10 ± 0.1 % (± 0.01 % / 0C) General Data EUT control / Connector Connection to Computer 9-pin Sub-D; RS-232 USB Temperature range 0 to 40 C Warm-up time Primary Power Mechanical Data Housing Width / height / depth Weight (shipping) 15 min 115 / 230 VAC ± 10%, 50-60 Hz 19 Subrack or desktop case 449 mm / 177 mm / 580 mm approx. 40 kg (net 34 kg) 241309 Seite 3 von 8

Additional Equipment Loop Sensor/Radiating Loops: For immunity tests radiating loops are necessary to generate magnetic fields. Suitable loops are available. Measuring emissions require loop sensors which can also be ordered from our company Loop Sensor MGA_LS040 Radiating loop MGA_RL120 Radiating Loop / Loop Sensor MGA_RLS133 Mechanical Data Loop sensor MGA_LS040 Radiating loop MGA_RL120 Loop sensor MGA_LS133 Loop sensor / radiating loop MGA_RLS133 Diameter 40 mm 120 mm 133 mm 133 mm Body material PVC MDF MDF MDF Wire 7-41 Litz wire 2.0 mm copper wire 7-41 Litz wire 0.25 mm² Litz wire Number of turns 51 20 36 36 Number of layers 1 4 4 4 Shielding Electrostatic none Electrostatic Electrostatic Distance to EUT 5 cm 5 cm 7 cm 10 cm / 5 cm Connector at coil Speakon 4 mm MC socket Speakon Speakon Connector at cable XLR 4 mm MC plug XLR XLR / 4 mm MC plug Coil factor (50 mm) --- 76,3 1/m --- 138,5 1/m Correction factor see calibration sheet (50 Ω / 600 Ω / 1MΩ) --- see calibration sheet (50 Ω / 600 Ω / 1MΩ) see calibration sheet (50 Ω / 600 Ω / 1MΩ) DC resistance ~ 4,5 Ω ~ 0,05 Ω ~ 10 Ω ~ 1,1 Ω Inductance ~ 130 µh ~ 120 µh ~ 340 µh ~ 340 µh Resonant frequency --- > 1.8 MHz --- > 0.9 MHz 10 Hz - 1 MHz DC - 500 khz 10 Hz - 1 MHz DC / 10 Hz - 500 khz Nominal current --- 15 A --- 5 A General Data Connecting cable Microphone cable Litz wire 2 x 1.5mm² Microphone cable Microphone cable / Litz wire 2 x 1.5mm² 241309 Seite 4 von 8

Additional Equipment Helmholtz Coils Several Helmholtz coils are available for susceptibility tests. Our company also offers tri-axial Helmholtz coils which are suitable for MGA1030. To achieve 1000 A/m at 1 khz, it is absolute necessary to use our Helmholtz coils and an optional compensation board. Helmholtz coil MGA_HCS_50-28 with loop sensor MGA_RLS_133 Triaxial Helmholtz coil MGA_HCST_50-28 Mechanical Data Helmholtz Coil MGA_HCS_50-28 Helmholtz Coil MGA_HCS_125-75 Helmholtz Coil MGA_HCST_50-28 Number of axes 1 1 3 Dimension [cm] 50 125 50 / 46 / 42 Number of turns (per coil) 22 + 4 40 + 10 22 + 4 Coil separation [cm] 28 75 28 Coil factor [m -1 ] (typical) 65.9 / 11.2 47.5 / 10.3 X-axis: 66.1 / 11.3 Y-axis: 67.8 / 11.8 Z-axis: 69.1 / 12.2 Total resistance DC [ ] (typical) 0.63 / 0.15 9.8 / 2.0 X-axis: 0.58 / 0.10 Y-axis: 0.53 / 0.09 Z-axis: 0.48 / 0.08 Total inductance [mh] (typical) 1.73 / 0.07 16.4 / 1.0 X-axis: 1.73 / 0.07 Y-axis: 1.52 / 0.06 Z-axis: 1.33 / 0.05 Resonant frequency [khz] > 150 khz > 150 khz > 150 khz Rated current [A] 16 5 16 Short term current [A] 20 7 20 241309 Seite 5 von 8

Additional Equipment Coupling Transformer MIL-STD-461E CS 101 requires a coupling transformer for conducted susceptibility tests. Our company has developed a coupling transformer which meets all requirements. Due to direct coupling to voltage mains, the coupling transformer has an additional differential amplifier for common mode rejection of the AC mains. Using the coupling transformer without this amplifier can destroy any measurement instrument due to overvoltage. Coupling transformer MGA_CT2.5-50AC with differential amplifier Primary Windings Inductance Current rating Input voltage (saturation level) Connector Secondary Windings Inductance Saturation Coupling Transformer MGA_CT2.5-50AC 12.5 mh (unloaded) 16 A 15 Hz: > 12,5 Veff 30 Hz: > 25 Veff Safety panel receptacle Ø 4 mm > 2 mh (unloaded) 50 A (AC or DC) Connector Safety panel receptacle Ø 6 mm (<50 A) Integrated Ø 4 mm socket (<32A) Secondary (monitor) General Data Turns ratio Precision resistor Differential Amplifier CMRR Noise Output Mechanical Data 0.1 A, BNC 15 Hz - 250 khz 2.5 : 1 (step down) 0.5 Ohm, 1%, 100 W, active cooling DC - 800 khz (small signal) / DC - 200 khz (full power) > 60 db (400Hz) < 6.5 mvrms (DC - 1 MHz) 20 Vpp / 10 ma Dimension 170 mm x 180 mm x 365 mm (W x H x D) Weight approx. 20 kg 241309 Seite 6 von 8

Additional Equipment Testing Equipment According to EN 55103-2 EN 55103-2 requires certain immunity tests for frequencies from 50 Hz to 10 khz. The following test equipment fulfills all requirements according to EN 55103-2, annex B Common mode test adapter MGA_B1 according to Fig. B.1 (EN 55103-2) Calibration network MGA_B2 according to Fig. B.2 (EN 55103-2) Current transducer incl. correction network MGA_B4 according to Fig. B.4 (EN 55103-2) Common mode test adapter MGA_B1 Calibration network MGA_B2 Current transducer incl. correction network MGA_B4 General Data Connectors Generator in: BNC Output: XLR male Input: XLR female Output: XLR male Audio in: 4mm MC safety jacks Input: XLR female Output: XLR male 241309 Seite 7 von 8

Ordering Information MGA_1032 MGA_1033 MGA_1034 MGA_VT-20 MGA_LS040 MGA_RL120 MGA_LS133 MGA_RLS133 MGA_BC-500 MGA_HCS_50-28 MGA_HCS_125-75 MGA_HCST_50-28 MGA_CT_2.5-50AC Description Option: Coil inductance compensation board (for 1000 A/m at 1000 Hz) MGA1030-16: Magnetic Field Generator / Analyzer (16A Amp.) including software MGA1030-16/SYS: Ready to use test system for magnetic field immunity tests; incl. software, compensation board, triaxial coil MGA_2025_HCST_50-28; for the generation of magnetic fields up to 1000 A/m at 1000 Hz Variable transformer for short-term fields acc. to EN 61000-4-8. Pri.: 230V, sec.: 0 260 V/20A; including cables Loop sensor 40 mm (acc. to MIL-STD-461E RS101) including 3m cable, calibration sheet Radiating loop 120 mm (acc. to MIL-STD-461E RS101) including 3m cable, calibration sheet Loop sensor 133 mm (acc. to MIL-STD-461E RE101) including 3m cable, calibration sheet Radiating / loop sensor 133 mm (acc. to EN 55103-1/2) including 2 x 3m cable, calibration sheet Radiating loop 500mm (acc. to EN 55103-2) including cables Helmholtz coil 50x50x28 mm (acc. to MIL-STD-461E, ISO 11452-8 etc.) including cables Helmholtz coil 125x125x75 mm (acc. to MIL-STD-461E, ISO 11452-8 etc.) including cables Tri-axial Helmholtz coil 50x50x28 mm (acc. to MIL-STD-461E, ISO 11452-8 etc.) including cables Coupling Transformer (acc. to MIL-STD-461 CS101) MGA_B1 Common mode test adapter acc. to Fig. B.1 (EN 55103-2) MGA_B2 Calibration network acc. to Fig. B.2 (EN 55103-2) MGA_B4 Current transducer incl. correction network acc. to Fig. B.4. (EN 55103-2) MGA_SO_CE101 MGA_SO_CS101 MGA_SO Software upgrade MIL-STD-461E / CE101 Software upgrade MIL-STD-461E / CS101 Software upgrade MIL-STD-461E / CS109 MGA_SO Software upgrade EN 61000-4-16 241309 Seite 8 von 8