Model Selection Model Output Current Total OVP Number Class Volts (Convection Cooled) Efficiency 1 Ripple &Noise 2 Regulation Threshold

Similar documents
MB120S 120W Single Output Medical Series

TB65 65W Single Output Test and Measurement/Industrial Series

TE90 90W Single Output External Power Test & Measurement/Industrial Series

LB115S 115W Single Output

TE W Single Output External Power Test & Measurement/Industrial Series

TE60 60W Single Output External Power Test & Measurement/Industrial Series

TE60 60W Single Output External Power Test & Measurement/Industrial Series

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features

TE40 40W Single Output External Power Test & Measurement/Industrial Series

FEATURES AND BENEFITS. Compact size: 6.5 x 2.8 x 1.5

Doc. EA Model Number:

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Electrical Specifications

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

C B. Models. Models 2MOPP

General. Environmental. EMC & Safety

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

3 in 1 Dimmable (0-10Vdc, PWM signal, or resistance)

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

150 Watt Industrial (WLT)

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

M A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

IEC/EN/UL60950 & CE certified, EN55032 Class B

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Parameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

Electrical Specifications

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

For more information, please visit the product page. output. output current max (A)

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

LFWLP W 12V 15.00A 25.00A 92%

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

Medical / Industrial AC-DC Power Supply 1200W with 5V/2A Standby / MEB-1K2A series

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

Features. Regulated Converter RAC Watt Single Output. AC/DC Converter

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

VOF XX - XXX - X

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

VMS-300A - XX - XXX - X

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

75W Constant Current (700mA) LED Driver

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

50W Constant Current (700mA) Dimming LED Driver

IP67 DESCRIPTION KEY FEATURES MARKET SEGMENT AND APPLICATIONS TRC ELECTRONICS, INC

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

Output Voltage (Vfan) Convection-cooled (6,7) Forced-cooled (8) & Current

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Output Voltage (Vfan) & Current

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

MTC Series 15 W AC/DC Switching Power Supply Module Medical

Output Voltage* (nom.)(adjustable)

Load (2) Single or Dual

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

4.59A 2.36A 6.8A 13A 3.85W 2.85W ms 21ms. 31ms 100ms 48Vout 49ms 100ms. 240mVp-p 480mVp-p C 48Vout 480mVp-p

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

PDAM500 Series 500W Power Supply

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Transcription:

Features 2 x 3.5 x 1.3 Package, Ideal for 1U Applications 10-year life design with Premium E-Caps 65 Watts convection cooled Class I and Class II models Class B Conducted and Radiated EMI Performance BF Isolation Type Rated Designed to meet new IEC 60601-1-2 4 th Edition EMC Requirements Approved to AAMI ES/CSA C22.2/EN/IEC60601-1, 3 rd Edition 2 x MOPP Isolation Internal Temperature Monitor, DC OK Signal, LED 3 Year Warranty Description A superior performance 65 Watt AC to DC power supply designed for next generation medical applications. Feature rich and highly efficient, MB65 product family can easily fit in a 1U chassis and provides 65 Watts of convection power. Input & output and internal temperature monitoring/alarms are features of the MB65 family. All models are CE marked to low voltage directive and approved to AAMI ES/CSA C22.2 No./EN/IEC60601-1, 3 rd edition. The design takes into consideration the pending international release of the new IEC 60601-1-2, 4 th Edition EMC requirements. With low leakage current performance, the power supplies are BF rated. Model Selection Model Output Current Total OVP Number Class Volts (Convection Cooled) Efficiency 1 Ripple &Noise 2 Regulation Threshold MB65S12K Class I 12V 5.4A 88% 0.5% ±1% 17.3 ± 2.4V MB65S12C Class II 12V 5.4A 88% 0.5% ±1% 17.3 ± 2.4V MB65S15K Class I 15V 4.3A 88% 0.5% ±1% 20.1 ± 2.4V MB65S15C Class II 15V 4.3A 88% 0.5% ±1% 20.1 ± 2.4V MB65S24K Class I 24V 2.7A 89% 0.5% ±1% 29.3 ± 3.5V MB65S24C Class II 24V 2.7A 89% 0.5% ±1% 29.3 ± 3.5V MB65S48K Class I 48V 1.35A 90% 0.5% ±1% 55.5 ± 4.5V MB65S48C Class II 48V 1.35A 90% 0.5% ±1% 55.5 ± 4.5V Notes: 1) Efficiency, Typical at 115/230Vac, 25 C. See Charts below for load conditions. 2) Measured at 25C using 6 inch twisted pair wires with noise probe directly across output terminals, and load terminated with 0.1µF ceramic and 10µF low ESR capacitors. 3) Part number suffix to include K for Class-1 AC input, or C suffix for Class-2 AC Input Consult Factory for following Models, availability may vary. MB65S18K Class I 18V 3.6A 89% 0.5% ± 1% 21.7 ± 2.5V MB65S18C Class II 18V 3.6A 89% 0.5% ± 1% 21.7 ± 2.5V MB65S28K Class I 28V 2.3A 89% 0.5% ± 1% 35.2 ± 3.5V MB65S28C Class II 28V 2.3A 89% 0.5% ± 1% 35.2 ± 3.5V MB65S32K Class I 32V 2.0A 89% 0.5% ± 1% 41.5 ± 4.5V MB65S32C Class II 32V 2.0A 89% 0.5% ± 1% 41.5 ± 4.5V www.slpower.com MB65S Aug -14 1

General Specifications AC Input 85-264Vac, single phase. (Safety Approved to 90-264Vac). Turn On Time <2 Seconds at 110Vac. Input Current 1.5A at 110Vac, 1A at 240Vac Rise Time <30mS, 48V model: < 40mS Inrush Current 40Arms Maximum within a half line cycle, cold start at 25C. See application note. Hold-up Time 20mS min. from loss of AC input at 110 Vac, full load, 25 C. I²T Characteristic See Table below. Over Load Protection (OCP) 115% - 200% of rated output current value. Hiccup Mode, Auto-recovery Turn-On Input Voltage >75Vac ± 8Vac. Full spec performance at 85Vac. Short Circuit Protection (SCP) Short across the output terminals will not cause damage to the unit. Hiccup Mode, Auto-recovery Turn-Off Input Voltage <63Vac ± 8Vac Over Voltage Protection (OVP) Latches off when output voltage is with range as shown in table. Requires AC Power cycle to reset Input Fuses 3.15A, 250Vac, line and neutral inputs Earth Leakage Current Patient Leakage Current (Output to Earth) Touch Current No Load Input Power <0.5W <350 µa@264vac, 60Hz input, NC Over Temperature Protection (OTP) Output Reverse Voltage Protection <4 ma@264vac, 60Hz input, NC for BF rating Isolation <90 µa@264vac, 60 Hz input, NC, also suitable for BF rating <450 µa@264vac, 60Hz input, SFC, also suitable for BF rating Turn-On & Operating Temperature Storage Temperature Power shuts down at temperature of 70 (typical) at full load. Hiccup Mode, Auto-recovery Outputs protected against momentary reverse current less than 20A peak for less than 10mS with 0.5A average. Sustained reverse current at high levels may damage unit. Input-Output: 4500Vac, 2 x MOPP Input-Ground: 1900Vac, 1 x MOPP Output-Ground: 1900Vac, 1 x MOPP -20 C to +70 C. Turn on Temperature = -40 C at >=120Vac, allowing [x] seconds for stabilization. De-rated output power at 70 C = 45.5W -40 C to +85 C Efficiency 88% - 90% typical at 115/230Vac, 25 C. See chart for additional details Altitude Operating: -500m to 3000m Non-operating: -500 to 40,000 feet Output Power Transient Response Ripple and Noise 0.5% pk-pk Output Voltage 65W continuous convection cooled, -20C to 50 C ambient. 85Vac to 264Vac. See chart for derating above 50 C. 500µS typ. response time for return to within 0.5% of final value for a 50% load change, i/ t< 0.2A/µs. Max. volt. deviation is ±3.5%. 12V to 48Vdc. See models chart for part numbering. Voltage Adjustability +/- 10%, 48V is +/- 5% Relative Humidity 5% to 95%, non-condensing Shock (IEC 60068-2-27) Vibration (IEC 60068-2-6) (IEC 60068-2-64) MTBF E-Cap Life Operating: Half-sine shock waveform. Impact Acceleration: 20g, Pulse duration: 11mS. Cycles: 3 times per axis in X,Y, Z direction Non-Operating: Half-sine shock waveform. Impact Acceleration: 100g, Pulse duration: 6mS Cycles: 3 times per direction on 3 axes (X,Y. Z) Operating: Sinusoidal Frequency: 10-500Hz, Impact Acceleration: 1g, Sweep rate: 1 octave/min Cycles: 10 times per axis in X, Y, Z direction Random Vibration: Operating: 0.003g 2 /Hz, 1.224grms overall, 3 axes, 10 min per axis, 1-500Hz. Non-Operating: 0.02g 2 /Hz, 3.1grms overall, 3 axes, 1 hour per axis, 20-500 Hz 564,500 hours (ave) @ 110Vac, 25 C, SR332 Issue 6. Consult Factory @ 220Vac, 25 C, SR332 Issue 6. >10 Years in use condition of 40 C ambient, at 12h/day, 261 days/year. Additional information on other use profiles available on request. www.slpower.com MB65S Aug -14 2

General Specifications (Continued) Overshoot HF Common Mode Noise <2% overshoot at turn-on, <1% overshoot at turnoff, under all conditions. Total Regulation ±1.0 % for all models. 0.8 Vrms maximum (input class I) Safety Standards IPC 610 Class 2 IEC 60601-1, 3 rd Edition ANSI/AAMI ES60601-1 (2008) CAN/CSA C22.2 No 60601-1 (2005) DEMKO EN60601-1:2006 Designed to meet China Safety Doc. No. GB4943.1-2011 at 5Km, Tropical Standard at 40 C, 93% RH at 120 hours. Weight 140g, typical Minimum Load Not required. Dimensions W: 2.0 x L: 3.5 x H: 1.3 W: 50.8mm x L: 88.9mm x H: 33.02mm Additional Outputs DC OK: During normal operation, this signal is logic HIGH. Signal will go LOW for output less than 80% (typical) of nominal. Green LED will light on PCB top side during normal operation. PSU Temperature Provides resistive value indicating internal temperature of power supply. See Temp Sensor Conversion Table below. EMI/EMC Compliance Conducted Emissions Radiated Emissions Harmonic Current Emissions EN55011/22: Class B, FCC Part 15. Class B: 6db margin typ, Class 1 PSU configuration EN55011/ 22: Class B, FCC Part 15. Class B: 2db margin typ, Class 2 PSU configuration EN55011/22: Class B, FCC Part 15. Class B: 3db margin typ, Class 1 PSU configuration. EN55011/22: Class B, FCC Part 15. Class B: 3db margin typ, Class 2 PSU configuration. IEC61000-3-2: Class A Voltage Fluctuations & Flicker IEC 61000-3-3 Electro Static Discharge Immunity Radiated RF EM Fields Susceptibility IEC61000-4-2: Level 4, 8kV Contact Discharge, 15kV air discharge, Criteria A. Also meets proposed IEC60601-1-2, 4 th edition, Table 4 IEC61000-4-3: Level 3, 10V/m, Criteria A. 80MHz-1000 MHz and 3V/m 1.4Ghz to 2.7 GHz. 80% AM at 1kHz. Also meets proposed IEC60601-1-2, 4 th edition, Table 4 Proximity Fields from RF wireless communications Equipment [IEC60601-1-2: 4 th edition, Table 4] Rated Power Frequency magnetic fields Low Frequency magnetic fields IEC61000-4-8: Level 5, 30A/m, 50/60 Hz [TBD] Electrical Fast Transients /Bursts Surges Line to Line (DM) and Line to Ground (CM) Conducted Disturbances induced by RF Fields Rated Power Frequency Magnetic Fields Test Voltage Dips Enclosure Port Immunity to RF wireless communications equipment IEC61000-4-4: Level 3, 2KV, 100Khz rep rate, 40A (PS Output), Criteria A IEC61000-4-4: Level 3, 1kV, 20A, (Other Outputs), Criteria B Also meets proposed IEC60601-1-2, 4th edition standard, Table 5 & 6. IEC61000-4-5: Level 3, +/-1kV DM, +/-2kV CM, Criteria A Also meets proposed IEC60601-1-2, 4th edition standard, Table 5. IEC61000-4-6: 3V/m & 10 V/m 0.15 to 80Mhz and 10V/m in ISM and amateur radio bands between 0.15 MHz and 80 MHz, 80% AM at 1 KHz Also meets proposed IEC60601-1-2, 4th edition standard, Table 5 & 6 & 8. IEC61000-4-8: Level 4 (30A/m), Criteria A Also meets proposed IEC60601-1-2, 4 th edition standard, Table 4 enclosure port. IEC61000-4-11: 100% dip for 10mS, at 0, 45, 90, 135, 180, 225, 270 and 315, Criteria A; 60% dip for 100mS, Criteria B; 30% dip for 500mS (25/30 cycles) 1, and 0 for 500mS, Criteria A. Also meets proposed IEC60601-1-2, 4 th edition standard, Table 5. IEC61000-4-3 Notes: Performance criteria are based on definitions contained in EN55024. Performance criteria are: A Normal performance during and after the test, B Temporary degradation, self-recoverable, C Temporary degradation, operator intervention required to recover the operation, D Permanent damage may occur www.slpower.com MB65S Aug -14 3

Isolation Specifications Insulation Safety Rating Parameter Conditions/Description Min Nom Max Units Electric Strength Test Voltage Mechanical Drawing Input/Ground Input/Output Output/Ground Input/Ground Input/Output Output/Ground 1900 4500 1900 1 MOPP 2 MOPP 1 MOPP - - Vac Vac Vac Connector Information Input Connector J1 PIN 1) AC Line PIN 2) Empty (removed) PIN 3) AC Neutral Mating Connector: DC Output Connector J2 Pin 1) (+V1) Pin 2) (+V1) Pin 3) (RTN) Pin 4) (RTN) Mating Connector: Ground Connector G1 FG 0.187 Quickconnect tab Mating Connector: Signal Connector J3 PIN 1) RTN PIN 2) DC_OK Pin 3) TEMP SEMSOR (+) Pin 4) TEMP SEMSOR (-) Mating Connector: Tyco/AMP 640250-3 Pins: 640252-2 Tyco/AMP 640250-4 Pins: 640252-2 Molex 01-90020005 Tyco/AMP 1375820-4 Pins: 1375819 www.slpower.com MB65S Aug -14 4

1.DC-OK signal (J-3): During normal operation, this signal is logic HIGH for output more than 85% (typical) of normal. Signal will go LOW for output less than 80% (typical) of normal. Green LED will light on PCB top side during normal operation. 2. Temperature sensor signal (J-3): Internal Temperature Sensor Conversion Table Resistance Value across connector J3, Internal pins 3-4 Temperature 6,040K ohms -20 3,227K ohms -10 1,788K ohms 0 1,025K ohms 10 605.1K ohms 20 367.6K ohms 30 229.2K ohms 40 146.4K ohms 50 95.62K ohms 60 63.80K ohms 70 43.40K ohms 80 30.07K ohms 90 21.19K ohms 100 Notes: 1) Tolerances: -20 C to 60 C: +/- 4 C; 70 C to 80 C: +/- 5 C; 90 C to 100 C: +/- 6 C. www.slpower.com MB65S Aug -14 5

3. Timing Sequence 4. Protection All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Conditions/Description Min Nom Max Units Input Fuses Not user accessible Input Transient Protection 2KV(CM) and 1KV(DM) surge 2 KV (CM) Output No-load and short circuit proof short circuit proof overload Hiccup Hiccup Hiccup Overvoltage Protection Latch style Latch Over temperature Protection Automatic power shutdown at TA = 80 C(typical) 5. Inrush Current, peak (I 2 T rating) Measured at 264Vac, 50 C at 100% loading, 70 C at de-rated load condition Model 50 C - I 2 T rating (A 2 Seconds, Typical) 70 C - I 2 T rating (A 2 Seconds, Typical) 12V Model 8.5 11.0 15V Model 6.5 13.2 24V Model 10.9 12.2 48V Model 10.4 11.1 www.slpower.com MB65S Aug -14 6

6. Characteristic Curves 6.1 Output vs. Temperature Output Power -Convection vs. Ambient Temperature Output Power (Watts) 70 60 50 40-20 -10 0 10 20 30 40 50 60 70 Ambient Operating Temperature ( C) 65W convection cooled at -20 C to 50 C operating ambient temperature. De-rated output power to 45.5W at 70 C. 6.2 Efficiency vs. Loading at AC Input Voltages 100% 90% 80% 70% Efficiency 60% 50% 40% 30% 20% 10% 0% 0.0 6.5 13.019.526.032.539.145.351.958.465.0 Output power(w) 115V 230V High efficiency is achieved by using QR technology. Synchronous MOSFETs or ultra-fast diodes are used as rectifiers in MB65S family. www.slpower.com MB65S Aug -14 7

6.3 Efficiency vs. Loading The charts below detail the MB65 efficiency vs input voltage and output loading conditions at 25 C, 50 C and 70 C under de-rated power. 25 C ambient 50 C Ambient Efficiency 91.0% 90.0% 89.0% 88.0% 87.0% 86.0% 115V 12V 230V 12V 115V 15V 230V 15V 115V 24V 230V 24V Efficiency 92.0% 91.0% 90.0% 89.0% 88.0% 87.0% 86.0% 115V 12V 230V 12V 115V 15V 230V 15V 115V 24V 230V 24V 70 C 115V 48V 115V 48V Load(% of rated) 230V 48V Load(% of rated) 230V 48V Ambient Efficiency 91.0% 90.0% 89.0% 88.0% 87.0% 115V 12V 230V 12V 115V 15V 230V 15V 86.0% 115V 24V 230V 24V Load(% of rated) 115V 48V 6.4 Ripple & Noise Measured using a scope probe socket with 0.1µF ceramic and a 10µF electrolytic capacitor connected in parallel across it. Bandwidth limit is 20MHz. 12V OUT, NO LOAD, 85VAC, 60HZ 12V OUT, FULL LOAD, 85VAC, 60HZ www.slpower.com MB65S Aug -14 8

6.4 Ripple & Noise (Cont d) 12V OUT, NO LOAD, 264VAC, 50HZ 12V OUT, FULL LOAD, 264VAC, 50HZ 6.5 Output Transient Response 50% load step within the regulation limits of minimum and maximum load, di/dt< 0.2A/µSec. Recovery time not specified as there are no lapse in regulation with a 50% Load Step. Maximum voltage deviation is 3.5% 5%~50% Load Transient (AC) at 25 C@115V 50%~100% Load Transient(AC) at 25 C@115V www.slpower.com MB65S Aug -14 9

6.6 Output Overload Characteristic Supply protects itself against overload conditions. The Power Supply recovers from Overload Conditions without operator intervention. 12v out, 100Vac 12V out, 240Vac 6.7 Turn-On Time 12v out, FULL Load, 115Vac 12V out, Full Load, 230Vac Data Sheet 2014 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com MB65S Aug -14 10