WDG 51 - Technical Data Sheet

Similar documents
WDG 61 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 83 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 71 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 13 - Technical Data Sheet

WDG 07 - Technical Data Sheet

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

PI734C - Technical Data Sheet

PI734A - Technical Data Sheet

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PM734B - Technical Data Sheet. Generator Solutions AS

S4L1D-G41 Wdg Technical Data Sheet

S4L1S-D4 Wdg.17 - Technical Data Sheet

S0L1-J1 - Technical Data Sheet

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

440 (12) 416 (12) 416 (12) 440 (12)

PARTNER ALTERNATORS LSA 40-4 Pole

Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

LSA Pole. R 726 Mains paralleling

HCM634G - Technical Data Sheet

Low Voltage alternators - 4 pole LSA 47.2

Low Voltage alternators - 4 pole LSA 46.2

PARTNER ALTERNATORS LSA Pole

ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx

TAL 047 Low Voltage Alternator - 4 pole

TAL 049 Low Voltage Alternator - 4 pole

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

TAL 044 Low Voltage Alternator - 4 pole

Spec Information. Reactances Per Unit Ohms

Spec Information. Reactances Per Unit Ohms

GENERATOR DATA JANUARY 30, 2015

Application Guidance Notes: Technical Information from Cummins Generator Technologies

Packaged Generators: New Kato Engineering Packaged Generator Line: Over 75 Years of Experience: Conformity: Service: Quality Standards:

AGN 034 Alternator Reactance

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

Generator Advanced Concepts

AGN 005 Fault Currents and Short Circuit Decrement Curves

SPECIFICATION, CONTROLS AND ACCESSORIES

Orbital GFI Inverter Series

SPECIFICATION, CONTROLS AND ACCESSORIES

AGN 124 AVR Power Supplies

SPECIFICATION, CONTROLS AND ACCESSORIES

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

SYNCHRONOUS MACHINES

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

AGN 022 Conditions for Parallel Operation

AGN 124 AVR Power Supplies

D I G I T A L V O L T A G E R E G U L A T O R

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

Sizing Generators for Leading Power Factor

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

Code No: R Set No. 1

Generation Interconnection Study Data Sheet Synchronous Machines

Contents. About the Authors. Abbreviations and Symbols

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

Power Processor - Series 700F 10KVA to 150KVA

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

Conventional Paper-II-2011 Part-1A

STEADY STATE REACTANCE

The new Yaskawa Varispeed G7 Inverter

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

Low Voltage Alternators

Using the VR448 in place of the Marathon DVR 2000

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

APPENDIX B: Generation Interconnection Application Form

R448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A

PAPER-II (Subjective)

Technical Data Sheet for AvK-Alternators

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

Technical Data Sheet for AvK-Alternators

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

Technical Data Sheet for AvK-Alternators

ECP3 4. Rev. 1. Powered by TCPDF (

NPE32 4. Rev. 1. Powered by TCPDF (

PART 1 OWNER/APPLICANT INFORMATION

VOLTAGE REGULATOR R 449. Installation and maintenance. This manual must be sent to the end user R 449 X2 Z1 X1 Z2 E+ E- (12V - 10A)

AGN 026 Harmonic Voltage Distortion

Technical Data Sheet for AvK-Alternators

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Impact Assessment Generator Form

Distributed Generation Application Form (Generation of Greater than 20 kw to 15 MW)

R438 A.V.R. Installation and maintenance. This manual is to be given to. the end user CALL US TODAY POWER-58. SHOP ONLINE

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

TABLE OF CONTENT

Transcription:

MV 804 S WDG 51 - Technical Data Sheet

FRAME MV 804 S SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including BS5000, VDE 0530, NEMA MG1-32, AS1359, CSA C22.2, UL and CE; as well as a wide range of international Marine Certification Approvals, can be met on request. For clarification regarding compliance please contact Cummins Generator Technologies DESCRIPTION The STAMFORD PI range of synchronous ac generators are brushless with a rotating field. They are separately excited by the STAMFORD Permanent Magnet Generator (PMG). This is a shaft mounted, high frequency, pilot exciter which provides a constant supply of clean power via the Automatic Voltage Regulator (AVR) to the main exciter. The main exciter output is fed to the main rotor, through a full wave bridge rectifier, protected by surge suppression. VOLTAGE REGULATORS The P range generators complete with a PMG are available with one AVR. The AVR has soft start voltage build up and built in protection against sustained over-excitation, which will de-excite the generator after a minimum of 8 seconds. Underspeed protection (UFRO) is also provided on both AVRs. The UFRO will reduce the generator output voltage proportional to the speed of the generator below a presettable level. The MA330 AVR is 3 phase rms sensed with a voltage regulation of 0.5% rms (see the note on regulation). The UFRO circuit has adjustable slope and dwell for controlled recovery from step loads. An over voltage protection circuit will shutdown the output device of the AVR, it can also trip an optional excitation circuit breaker if required. As an option, short circuit current limiting is available with the addition of current transformers. The MA330 AVR needs a generator mounted current transformer to provide quadrature droop characteristics for load sharing during parallel operation. Provision is also made for the connection of the STAMFORD power factor controller, for embedded applications, and a remote voltage trimmer. WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for troublefree supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low levels of voltage waveform distortion. TERMINALS & TERMINAL BOX Standard generators feature a main stator with 6 ends brought out to the terminals, which are mounted on the frame at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access. SHAFT & KEYS All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. INSULATION/IMPREGNATION The insulation system is class 'H'. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. NOTE ON REGULATION The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%. NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing is typical of the product range. 2

FRAME MV 804 S WINDING 51 RATINGS REFER TO SALES AND SERVICE BRIEFING MAXIMUM ALTITUDE 1000 METRES ABOVE SEA LEVEL MAXIMUM AMBIENT TEMPERATURE 40º C CONTROL SYSTEM SERIES 3 SEPARATELY EXCITED BY P.M.G. A.V.R. FULL WAVE RECTIFIED VOLTAGE REGULATION ± 0.5% WITH 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT REFER TO SHORT CIRCUIT DECREMENT CURVES OF THIS SECTION INSULATION SYSTEM CLASS H PROTECTION IP23 STANDARD RATED POWER FACTOR 0.8 STATOR WINDING DOUBLE LAYER LAP WINDING PITCH 2/3 WINDING LEADS 6 R.F.I. SUPPRESSION BS EN 50081/2-1/2 VDE 0875G VDE 0875N For other standards apply to the factory WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 3.0% MAXIMUM OVERSPEED 2250 Rev/Min BEARING DRIVE END ISO 6232 C3 BEARING NON DRIVE END ISO 6324 C3 EFFICIENCY REFER TO EFFICIENCY CURVES OF THIS SECTION FREQUENCY 50Hz 60Hz TELEPHONE INTERFERENCE THF< 2% TIF<50 COOLING AIR 3 m 3 /sec 3.5 m 3 /sec VOLTAGE STAR (Y) 3300 4160 kva BASE RATING FOR REACTANCE VALUES Xd DIRECT AXIS SYNCHRONOUS 2900 2.900 3530 2.500 X'd DIRECT AXIS TRANSIENT 0.231 0.213 X''d DIRECT AXIS SUB-TRANSIENT 0.170 0.157 Xq QUADRATURE AXIS REACTANCE 2.000 1.840 X''q QUAD. AXIS SUB-TRANSIENT 0.323 0.297 XL LEAKAGE REACTANCE 0.120 0.110 X2 NEGATIVE PHASE SEQUENCE 0.247 0.227 X0 ZERO PHASE SEQUENCE 0.039 0.036 REACTANCES ARE SATURATED T'd TRANSIENT TIME CONSTANT T''d SUB-TRANSIENT TIME CONSTANT T'do O.C. FIELD TIME CONSTANT Ta ARMATURE TIME CONSTANT SHORT CIRCUIT RATIO VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED 0.200 0.015 4.150 0.083 1/Xd STATOR WINDING RESISTANCE (L-N) ROTOR WINDING RESISTANCE EXCITER STATOR FIELD RESISTANCE EXCITER ROTOR RESISTANCE (L-L) PMG STATOR RESISTANCE (L-L) 0.03390 1.400 17.50 0.076 3.800 RESISTANCE VALUES ARE IN OHMS AT 20º C NO LOAD EXCITATION VOLTAGE 15.0 FULL LOAD EXCITAION VOLTAGE 63.0 Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. 3

FRAME MV 804 S WDG 51 50 Hz THREE PHASE EFFICIENCY CURVES 3300 V 98.0 97.5 1.0 97.0 % P.F. 96.5 0.9 96.0 0.8 95.5 95.0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 2900 kva FRAME MV 804 S WDG 51 60 Hz THREE PHASE EFFICIENCY CURVES 4160 V 98.0 97.5 1.0 97.0 0.9 96.5 % P.F. 96.0 0.8 95.5 95.0 94.5 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 3530 kva 4

FRAME MV 804 S WDG 51 50Hz FULL WAVE RECTIFIED AVR LOCKED ROTOR MOTOR STARTING CURVE X 30.0 3300V PER CENT TRANSIENT VOLTAGE DIP 25.0 20.0 15.0 10.0 5.0 0.0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 LOCKED ROTOR kva FRAME MV 804 S WDG 51 50Hz Three Phase Short Circuit Decrement Curve No- Load Excitation at Rated Speed Based on series star (wye) connection x 10000 NOTE 1 THE FOLLOWING MULTIPLICATION FACTORS SHOULD BE USED TO ADJUST THE VALUES SYMMETRIC ASYMMETRICAL FROM CURVES BETWEEN THE 0.001 SECONDS AND THE MINIMUM CURRENT POINT IN RESPECT OF NOMINAL OPERATING VOLTAGE VOLTAGE FACTOR 3300V X 1.00 CURRENT (Amps) 1000 THE SUSTAINED CURRENT VALUE IS CONSTANT IRRESPECTIVE OF VOLTAGE LEVEL NOTE 2 THE FOLLOWING MULTIPLICATION FACTORS SHOULD BE USED TO CONVERT THE VALUES CALCULATED IN ACCORDANCE WITH NOTE 1 TO THOSE APPLICABLE TO THE VARIOUS TYPES OF SHORT CIRCUIT 3 PHASE 2 PHASE L-L 1 PHASE L-N INSTANTANEOUS X 1.0 X 0.87 X 1.30 MINIMUM X 1.0 X 1.80 X 3.20 SUSTAINED X 1.0 X 1.50 X 2.50 MAX SUSTAINED DURATION 10 SEC 5 SEC 2 SEC 100 0.001 0.01 0.1 1 10 TIME (secs) ALL OTHER TIMES ARE UNCHANGED SUSTAINED SHORT CIRCUIT = 1522 Amps 5

FRAME MV 804 S WDG 51 60Hz FULL WAVE RECTIFIED AVR LOCKED ROTOR MOTOR STARTING CURVE X 30.0 4160V PER CENT TRANSIENT VOLTAGE DIP 25.0 20.0 15.0 10.0 5.0 0.0 0 1000 2000 3000 4000 5000 LOCKED ROTOR kva FRAME MV 804 S WDG 51 60Hz Three Phase Short Circuit Decrement Curve No- Load Excitation at Rated Speed Based on series star (wye) connection x NOTE 1 10000 THE FOLLOWING MULTIPLICATION FACTORS SHOULD BE USED TO ADJUST THE VALUES SYMMETRIC FROM CURVES BETWEEN THE 0.001 SECONDS AND THE MINIMUM CURRENT POINT IN ASYMMETRICAL RESPECT OF NOMINAL OPERATING VOLTAGE VOLTAGE FACTOR 4160V X 1.00 CURRENT (Amps) 1000 100 0.001 0.01 0.1 1 10 TIME (secs) THE SUSTAINED CURRENT VALUE IS CONSTANT IRRESPECTIVE OF VOLTAGE LEVEL NOTE 2 THE FOLLOWING MULTIPLICATION FACTORS SHOULD BE USED TO CONVERT THE VALUES CALCULATED IN ACCORDANCE WITH NOTE 1 TO THOSE APPLICABLE TO THE VARIOUS TYPES OF SHORT CIRCUIT 3 PHASE 2 PHASE L-L 1 PHASE L-N INSTANTANEOUS X 1.0 X 0.87 X 1.30 MINIMUM X 1.0 X 1.80 X 3.20 SUSTAINED X 1.0 X 1.50 X 2.50 MAX SUSTAINED DURATION 10 SEC 5 SEC 2 SEC ALL OTHER TIMES ARE UNCHANGED SUSTAINED SHORT CIRCUIT = 1862 Amps 6

FRAME MV 804 S WINDING 51 0.8 Power Factor RATINGS Class - Temp Rise Cont. F - 105/40 C Cont. H - 125/40 C Standby - 150/40 C Standby - 163/27 C 50Hz Star (V) kva 3300 3300 3300 3300 2660 2900 3100 3190 kw 2128 2320 2480 2552 Efficiency (%) 96.4 96.3 96.2 96.1 kw Input 2208 2409 2579 2655 60Hz Star (V) kva kw 4160 4160 4160 4160 3250 3530 3775 3880 2600 2824 3020 3104 Efficiency (%) 96.5 96.4 96.4 96.3 kw Input 2695 2928 3134 3222 TYPICAL DIMENSIONS - Further arrangements available - please refer to factory Barnack Road Stamford Lincolnshire PE9 2NB Tel: 00 44 (0)1780 484000 Fax: 00 44 (0)1780 484100 2009 TD_MV804S.51.GB_03.09_09_GB