Series PROPULSION TELEGRAPH PRIME MOVER CONTROLS INC.

Similar documents
Data Sheet. Earth Leakage Relay RISH ELR/ELR+/ELR VI/ELR VI(NE) A V RISH ELR VI. Record. Digital Protection Relay RESET TEST ENTER

RISH ELR Earth Leakage Relay Preliminary Datasheet True RMS Measurement Trip relay cum DPM CBCT Open Detection 4 digit 7 segment LED display

Data Acquisition Modules/ Distributed IO Modules

Wireless Gas Detection System

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

OVEN INDUSTRIES, INC. Model 5C7-362

C-Band Redundant LNA Systems

Modbus I/O. RS-485 to 3-wire Universal 50W Power Supply

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

X-Band Redundant LNA Systems

WaveNet. Wireless Monitoring.

Redundant LNA Systems

AS-LED COMBINED OBSTRUCTION LIGHTS

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Stand Alone Rudder Angle Indicator System

DEVICE CONFIGURATION INSTRUCTIONS. WinFrog Device Group:

3 & 4 Wire Self Compensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg.

MiniSafe Light Curtains

PEM353. Universal measuring device

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

Installing the IPS 4240 and the IPS 4255

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series

ISOMETER iso685- -B. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet

XIOC technology and networking modules

Parts Bulletin V"OLV"OPENTA. P QL Thruster Remote Control Models: QL Accessories. AB Volvo Penta SE Goteborg, Sweden

Contents. Instruction Leaflet IL E Effective March HMi VU Series Instruction Leaflet. Description... Page. Preface...

Absolute encoders multiturn

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

Magnetic absolute encoder GEL 2035 Serial interface (SSI), 24 Bit

Concept of Serial Communication

A Super trainer with advanced hardware and software features only found in very expensive equipment.

Modbus communication module for TCX2: AEX-MOD

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

ISOMETER IRDH575. Approvals

luxcontrol lighting control system DSI sensors smartdim SM lp Control module for combination with ambient light sensor, switch or presence sensor

2000W Pure Sine Wave Inverter / Charger

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

OPERATING MANUAL Rish Eine. Size: 48 x 96 Size: 96 x 96

TECHNICAL PRODUCT DATASHEET

1000TR. Instructions

ENCODER. SSI Multiturn. Series , Key-Features: Content:

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

General Specifications

Medidores de vibración salida RS232 Datalogger VT-8204 LUTRON manual ingles

XXXX e. X d.. X X X a

DCM20 Series. Three-Function DC Power Meters. DCM20 DISPLAY PRODUCT OVERVIEW FEATURES

MARITIME AND ENERGY PRODUCT CATALOGUE NOVEMBER

1M122A Transformer Parallel Control System

Conductivity Analyzer

Online data sheet FLOWSIC600 GAS FLOW METERS

ICM/ICAD Motorized Valve. Quick Start Guide. Installation, Programming, and Trouble-shooting REFRIGERATION & AIR-CONDITIONING

1 INTRODUCTION 1.1 PRODUCT DESCRIPTION

Hub and Cluster. ogramming Manual. Pro MAN3090

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

U-GAGE Q45U Long-Range Ultrasonic Sensors

Addendum 1.4_2. (Addendum to MX420 Operator s Manual)

NEW DIGITAL PUMP LOAD CONTROL

XARS8D18p / XARS12D18p / XARS8L12p Quick Start Guide

ACK. Menue. Channel 1 Alarm Channel 2 Ch 2. Outputs. Filter constant. Output: Current limit 0.11 A ± 10 % Int. voltage drop 2.5 V at max.

XXXX e. X d.. X X X a

LED Driver Compact dimming

SUBJECT TO CHANGE WITHOUT NOTICE

DFDA5000 Reserve Manual Controller. With Servo Amplifier. Operation Instruction

STRATUS CONTROLLER MANUAL September 14, 2015

8 Input/8 Output AC Block I/O Module

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

vacon 100 flow ac drives application manual

SAPLING WIRELESS SYSTEM

Relay Driver Overview and Applications

General Specifications

U1600 ENERGY CONTROL SYSTEM. Applications

Wiring Instructions for 10, 16 & 20 Function, 92 & 93 Series, FET Receivers.

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 350mA 550mA ECO lp ECO series

LED Driver Linear / area dimming. Udriver LCAI 20W 350mA 550mA ECO lp ECO series

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Absolute Encoders - Singleturn

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series

General Specifications

Alpha 50. Technical Data Sheet. Special Features

impact VC-500LR Monolight INSTRUCTIONS

Electronic Circuit Breaker ESS1 for System SVS1

ISOMETER iso685- Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

luxcontrol lighting control system DALI sensors basicdim RCL DBC Control module for combination with ambient light sensor, switch and presence sensor

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

BLuAC5 Brushless Universal Servo Amplifier

CROSS Chassis from 160 A to 450 A

Absolute encoders multiturn

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

AES Central Station. INCLUDING: 7000/2 Dual Receiver 7100 Network Controller 7030 Transceiver INSTALLATION & OPERATION MANUAL

ZIEGLER PRO-P Power / Phase Angle / Power Factor Transducer

Specification DataFile

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

TECHNICAL DATASHEET #TDAX021901

The Hue driver allows North to interface with a Philips Hue wireless lighting system. Available for Commander and ObSys.

The LEBOW 7554 Operator's Manual 7.2

Overboard Recovery Communications Apparatus (ORCA ) RX-102 Receiver User s Manual

Transcription:

PROUCT BULLETIN SB 8202-4000 Series 8202-4000 The PMC series 8202-4000 Engine Order Telegraph is a dependable and compact marine telegraph for single or twin screw systems. The 8202 functions independently of the ship s main propulsion controls and allows emergency operation when primary remote controls fail. FETURES Nine Port orders, nine Starboard orders, Bridge Control orders, and a Finished with Engines order Independent Standby orders Optional wrong direction alarms Single or twin screw Forward or ft facing ouble Ended vessels Up to nine engine room units and nine bridge units Super bright order indicators for daylight operation Backlit buttons for night operation Bridge units are dimmable Lamp test ual 24 V C supply inputs Redundant isolated 8202 networks (communication redundancy optional) river outputs for external order and wrong direction bells Self diagnostics and trouble shooting display IN mounting IP65 splash proof front Optional I/O: - Two relay outputs for system fault and power faults - Isolated RS485 comm port for Voyage ata Recorder - Local disable input - Machinery direction inputs PROPULSION TELEGRP PRIME MOVER S INC. SB 8202-4000

PROPULSION TELEGRP ESCRIPTION The PMC series 8202-4000 Engine Order Telegraph is a compact marine telegraph for single or twin screw systems. It operates as a stand alone or backup system. The 8202 functions entirely independently of the ship s main propulsion controls and allows emergency operation when primary remote controls fail. The 8202 provides pushbutton communications of all standard propulsion orders between bridge and engineroom. dditionally standby orders are included, these orders can be operated at any time independently of the propulsion orders. Communication is fully bi-directional; orders may be placed from either source. Optionally, propulsion machinery direction can be monitored in head, Stop¹, and stern positions. Wrong direction status is visually and audibly alarmed at all stations. Up to nine bridge and nine engineroom telegraphs may be connected together with a minimum configuration of one bridge and one engineroom telegraph. Twin screw telegraph systems can have split Port and Starboard telegraphs for local at machinery stations. Order indicators are super bright LEs for daylight operation and all buttons have backlit legends for night operation. Bridge telegraphs are fully dimmable and can be grouped together to dim in unison. esigned for the harsh marine environment, the 8202 is both rugged and reliable. Connections to the 8202 have been designed to reduce installation cost. Only one twisted pair cable is required for communication, or an optional seconded twisted pair cable can be used for redundant communication. Each telegraph is powered directly from the ship s 24 V C power and can auto transfer to a backup 24 V C power source. Self diagnostics are performed by each 8202 for various fault conditions. Fault status is visually and audibly alarmed at all stations. Set up of the 8202 (display type, order bell time delay, wrong direction, etc.) is via a navigation switch and LC, making set up and service a simple procedure. System accessories available from PMC include: bells, horns and project specific drawings. OPERTION The 8202 consists of three order groups: Port, Starboard and Standby orders. These groups operate as follows: 1. Completed orders are displayed as indicators steady ON and all audible signals are silent. 2. new order can be placed by pressing another order button which then flashes the newly requested order at all stations. t the same time the internal horn operates and will continue to operate until the order is acknowledged. The optional external order bell can be set to sound after an adjustable time delay. 3. The new order is acknowledged at the receiver by pushing the button next to the flashing order indicator, which then turns the order indicator to steady ON. The previous order is cancelled, and all audible signals are silenced. 4. New orders can be changed (by placing a different order) or cancelled (by pressing the existing acknowledged order) at the transmitting telegraph group prior to being acknowledged. (Optional) This option annunciates when the order direction (head, Stop¹, stern) does not match the propulsion machinery direction.: 1. The wrong direction alarm is enabled when an head, Stop¹, or stern order is acknowledged. The wrong direction alarm is disabled when Bridge Control or Finished With Engines is acknowledged. 2. If the acknowledged order and the machinery direction does not match, the wrong direction indicator will flash. fter an adjustable time delay, the internal horn and optional external bell will sound. 3. Pressing the Silence button will silence the internal horn and external bell. 4. When the acknowledged order matches the machinery direction, the wrong direction indicator will extinguish and the internal horn and external bell will silence. With a twin screw telegraph, the Port and Starboard wrong direction indicators function independently of each other. ¹ Wrong direction can be setup to ignore Stop. PRIME MOVER S

PRIME MOVER S INC. PRIME MOVER S INC. PRIME MOVER S INC. PRIME MOVER S INC. PRIME MOVER S INC. PRIME MOVER S INC. PROPULSION TELEGRP Typical Telegraph System Block iagram for twin screw installation Port Wing Console Bridge Center Console Starboard Wing Console 8202-4400 PROPULSION TELEGRP 8202-4400 PROPULSION TELEGRP 8202-4400 PROPULSION TELEGRP Primary & Secondary Power (16 WG cable) Optional communication to Voyage ata Recorder (16 WG shielded twisted pair) 8202 Network Cable(s) (One 16 WG shielded twisted pair, or two twisted pairs for optional redundant communication) Fault Contact to Ship's larm Primary & Secondary Power (16 WG cable) 8202-4400 PROPULSION TELEGRP Engine Control Room 8202-4100 PROPULSION TELEGRP 8202-4000 PROPULSION TELEGRP Port Local at Engine Stbd Local at Engine PRIME MOVER S

ENSIONS N CUTOUT FOR 8202-4000 SERIES PROPULSION TELEGRP SIE VIEW BCK VIEW CUTOUT PRIMRY BCKUP P/N S/N 21 192mm 7.56" 1 PRIMRY 2 3 BCKUP 4 5 6 Bell ORER 7 Bell 0V 8 Bell UX 9 Bell 0V PRIME MOVER S INC. 8202-4000 PROPULSION TELEGRP SETUP / 22 23 I/P 24 I/P 0V 25 ISBLE 26 27 UX 28 29 30 182mm 7.17" 182 134mm +1.0-0.0 7.17" 5.28" +0.04-0.0 10 ata COM 2 11 ata 12 ata COM 3 13 ata ata COM 0 ata 31 32 33 34 C2 ON C3 ESC Tx C0 ON Rx SW1 Rx Rx SW2 1mm (0.04") min. 16mm (0.63") max. 88mm 3.46" 7.5mm 0.30" 144mm 5.67" 134mm 5.28" Mounting hardware is included with each unit and consists of 4 knurled thumb nuts and 4 clamps. Mounting gasket pre-installed on all telegraph units. Supply: ual 24 V C inputs Nominal 24 V C, range 12 to 35 VC Low voltage alarm at 17 V C 320 m nominal, 500 m peak 780 m peak with 2 PMC bells active Input power fuse, 5, type TC-5 Inputs / Outputs (Standard): 2 bell driver outputs, high side driver, 2 amps @ supply power (self resetting over current / over temperature protection) 2 networks for 8202, isolated CN ports (self resetting fuses and terminator switch) Inputs / Outputs (Optional): Isolated RS485 comm port (NME 0183, Modbus RTU, or SCII printer logger) (self resetting fuses and terminator switch) 2 relay outputs, form 'C' contacts, 1 amp @ 24 V C 5 inputs, dry contacts required for inputs (local disable and propulsion machinery direction inputs) SPECIFICTIONS: Environmental: Operating temperature -20 to +70 C Storage temperature -30 to +80 C Vibration: Frequency range 2 to 100 z Peak to peak amplitude 2 mm below 13.2 z cceleration amplitude 0.7 g above 13.2 z Physical: IP65 front (IP40 case) imensions 192 mm 144 mm W 94 mm Weight 1.4 kg Removable terminal block for 14 to 20 WG wires Recessed Lexan System ccessories vailable from PMC: Wrong direction sensors Bells, horns, lights and beacons Project specific connection diagrams drawn with utoc Set up and testing of system by PMC personnel PROUCT REFERENCE\8202_TLG\C_BULLTN\SB-8202-4000R01.I PRIME MOVER S INC. 3600 GILMORE WY, BURNBY B.C. CN V5G 4R8 TEL (604) 433-4644 FX (604) 433-5570 LL RIGTS RESERVE

PROPULSION TELEGRP QUEIONNIRE Vessel Name: Year Built: Vessel Type: ull Type: Length: isplacement: Model Name: ull Number: IMO Number: Regulatory Body: Class: Class Notations: Number of Shafts: Single screw Twin screw ouble ended, twin screw Other (specify) Number of Telegraph Stations: (Specify *aft facing, outside and non-dimmable stations) Bridge Engine Control Room Local t Engine Other (specify) Machinery Wrong irection larm: Required udible and Visual evices: ( single bell can be used for both order active and wrong direction) QTY of telegraph order bells per station QTY of wrong direction bells per station Visual indicator/beacon (specify location) USCG power fault horn: Required ata Logger Output Signal: Power Source vailable: (Classification Society may require battery back up [UPS]) NME 0183 ModBus RTU Slave 24 V C (preferred) 120 V C 60 z Other (specify) Redundant Power Sources: Redundant Communication: Yes No Required PRIME MOVER S INC. 8202-4400 PROPULSION TELEGRP PRIME MOVER S INC. 8202-4400 PROPULSION TELEGRP Forward Facing *ft Facing Forward Facing *ft Facing PRIME MOVER S INC. 8202-4100 PROPULSION TELEGRP PRIME MOVER S INC. 8202-4100 PROPULSION TELEGRP PRIME MOVER S

PROPULSION TELEGRP PRIME MOVER S INC. 8202-4400 PROPULSION TELEGRP SCLE 1 : 1 PRIME MOVER S