Name Number of I/O points (words used) Model Antenna style. 512 outputs max. (32 words) Magnetic Base Antenna (1) --- WD30-AT001 (See note.

Similar documents
FA Wireless SS Terminals

CompoBus/D-type Digital Controller

High-speed, wireless communication with easy installation and simple wiring!! *Antenna sold separately. 250 m range. Antenna with cable available

Multi-point Temperature Controller

onlinecomponents.com

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

NPN PNP NPN PNP NPN PNP

CompoNet Gateway Unit for CC-Link

Multipoint Temperature Controller

Connect V680 Antennas and Amplifier Units to a V680-series Controller, and read or write data from or to RF Tags. Standard Programmable Controller

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

FP-DO-400 and cfp-do-400

Field Network SRT Series

Solid-state Timer H3DS

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

FINAL DRAFT TECHNICAL REPORT CLC/FprTR RAPPORT TECHNIQUE TECHNISCHER BERICHT January English version

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Distance-setting Photoelectric Sensor

Model Number Structure

FP-RLY-420. Features. Installing the FP-RLY-420. FieldPoint Operating Instructions. Eight-Channel SPST Relay Module

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

V680-HAM42-DRT DeviceNet ID Slave

Features. Panel Meters with Advanced Signal Processing Capabilities K3HB

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

Self-powered Counter

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

Smart Power Relay E I...

Correction Reissue. Product Discontinuation Notices

V680-CA5D01-V2. V700-A40/41/42/43/44/45 Cable length (2/3/5/10/20/30) M. Cable length (0.5/5/10) M. Antenna V680-H01-V2 Cable length 0.

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Ultraminiature Photoelectric Switches with Self-contained Amplifier

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

The compact test- disconnect terminal interface system for protection and secondary technology

Built-in Amplifier Photoelectric Sensor

1.5 GHz Active Probe TAP1500 Datasheet

Distance-setting Photoelectric Sensor

Digital Indicators K3HB Series

Remote Sensor Amplifier Terminal

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series

Phase-sequence Phase-loss Relay

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

1204 Reflected Wave Reduction Device

MODEL: WL40MW1F. Wireless I/O WL40F Series

Model Number Structure

Solid-state Twin Timer

Power supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model

Usable even in welding environments. From power supply ON to start of communication: Min. 250 ms * 1 *1 For wireless slave. Number of I/O points

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

Fasteners Torque/clamp force testing (ISO 16047:2005)

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:

Count/Time Totalizers

E2C-EDA. Proximity Sensor with Separate Amplifier Enables Easily Making Highprecision Sensitivity Settings. Ordering Information

Capacitive Proximity Sensor


Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

Process-Controller HPP-25

Absolute Rotary Encoder

Temperature Controllers E5 J

Z500. High-Precision Sensor that Measures and Displays an Object's Profile. Profile Measuring System

Walkie Talkie APMP300. User manual

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

FP-RTD-124 AND CFP-RTD-124. Features. FieldPoint Operating Instructions. Eight-Channel Four-Wire RTD and Resistance Input Modules

User Manual for 24 GHz Blind-Spot Radar Sensor

Communication systems for meters and remote reading of meters - Part 4: Wireless meter readout (Radio meter reading for operation in SRD bands)

Base Mounted Plug-in Unit

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

HRS2 Series PCB Relays

OPERATION MANUAL. SI unit EX120-SDN1 EX121-SDN1 EX122-SDN1 EX124D/U-SDN1

OPERATING INSTRUCTIONS NI Port DeviceNet Module

LENORD. +BAUER... automates motion. Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter

E2B PROXIMITY SENSORS

DATA SHEET MKP 435 X2

This document is a preview generated by EVS

Panel Mount PLC. NEW standard: Timer + Counter + Temperature Controller + PLC. The FP-e PLC comes in the following three types

Process Control HPP-25

40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES

Output configuration. Dark-ON. Light-ON. Dark-ON. Light-ON. Dark-ON. Light-ON

Regulatory Compliance Addendum for the Multi-Mode Wireless LAN Unit (WLU-2100)

RFC1000-CE Cloud Relay. MadgeTech Cloud Services Data Logger Hub. Product User Guide

CLV 480 Bar Code Scanner For near and far Dynamic focus control Advanced line

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

SCXI CURRENT INPUT,HIGH-VOLTAGE TERMINAL BLOCK

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

EE1941XS/EN1941XS One-Way Serial RF Module Installation and Operation Manual

PRODUCT DATA. DC Response Accelerometers Types 4570, 4571, 4572, 4573, 4574, and 4575

Temperature Input Module for Zone 1 Series 9482/32

Emitting and receiving element pitch: 10 mm in

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON

2-channel speed sensor GEL 247 Compact sensor for harsh applications

Through-beam ring sensors

SCXI High-Voltage Terminal Block

Fästelement Sexkanthålsskruvar (ISO 4762:2004) Hexagon socket head cap screws (ISO 4762:2004)

3. Contact Form A: SPST-NO

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

Transcription:

DeviceNet Wireless Communication WD30 The DeviceNet wireless units, consisting of a DeviceNet wireless master station and a DeviceNet wireless slave station, allow wireless communication with DeviceNet slaves. Up to 3,200 I/O points can be communicated through a single Unit. Uses spread spectrum technology for superior noise resistance in manufacturing environments. Compact construction. Long-range communications have been achieved with a relay function (3 repeaters max.). Explicit message communication is supported. Remote I/O Ordering Information List of Models Name Number of I/O points (words used) Model Antenna style DeviceNet Wireless Master 1,600 inputs max. (100 words) WD30-ME Pencil antenna 1,600 outputs max. (100 words) WD30-ME01 Magnetic base antenna DeviceNet Wireless Slave 512 inputs max. (32 words) WD30-SE Pencil antenna 512 outputs max. (32 words) WD30-SE01 Magnetic base antenna Magnetic Base Antenna (1) --- WD30-AT001 (See note.) --- Note: The WD30-AT001 Magnetic Base Antenna can be used with the WD30-ME, WD30-ME01, WD30-SE, and WD30-SE01. Optional Accessories (Micro Connectors) Name Model Shielded T-branch Connector DCN2-1 Connector with one branch Cable with Shielded Connectors DCA1-5CN@@W1 Cables with connectors on both ends DCA1-5CN@@F1 Cables with a connector socket on one end Shielded DRS2-1 with plug connector Included Accessories The following accessories are included with a DeviceNet Wireless Master or DeviceNet Wireless Slave. Two antennas DeviceNet Wireless Units Instruction Sheet Sticker Two M4 mounting bolts (with nuts, flat washers, and spring washers) Optional Accessories (Configurator Software) Name Model Configurator (PC Card) 3G8E2-DRM21-EV1 Configurator Software WS02-CFDC1-E WD30 571

System Configuration CS1W-DRM21 DeviceNet Unit DCN1-3C T-branch Tap Main line DeviceNet network Main line 3G8E2-DRM21-EV1 PC Card (included with Configurator Software) WS02-CFDC1-E Configurator Software (Ver. 2.2 or higher) Master DRS2-1 Slave DCN2-1 T-branch Connector DCN1-3C T-branch Tap with Master DRS2-1 DCN2-1 T-branch Connector PLC I/O Link Unit Slave DRS1-T Terminating Resistor Terminal Block E5EK-DRT Digital Process Controller Repeater DRS2-1 DCN2-1 T-branch Connector Slave DRS1-T Terminating Resistor Terminal Block General DeviceNet communications power supply 11 to 25 V DC (Supplied from the DeviceNet network power supply.) voltage Current consumption (See note.) 350 ma max. (at startup), 120 ma average Ambient temperature Operating: 10 to 50 C Storage: 20 to 65 C Ambient humidity Operating:25% to 85% (with no condensation) Weight Approx. 200 g Note: Select a power supply with excess capacity. (We recommend a minimum of 25 W.) 572 Remote I/O

Wireless Interface Wave type Communication method Frequency band Number of channels Antenna power Data transfer speed between wireless units Transmission distance (See note 1.) Relay stations Max. number of sets in the same area (See note 1.) Max. number of wireless Slaves Spread Spectrum (direct sequence; DS-SS) Simplex (half duplex) 2.4 GHz (2401 MHz to 2480.2 MHz) 34 channels (based on frequency division) 10 mw 100 kbps Indoors: 60 m (approx. 50 m with magnetic base antennas) Outdoors: 300 m (unobstructed) 3 repeaters max. 10 sets max. 64 max. Note: 1. The actual transmission distance depends on many factors in the installation environment. 2. The wireless system is not suitable for applications requiring real-time control. DeviceNet Interface (Summary) Communications functions (See Master/Slave connections Remote I/O functions and Explicit message communications functions note.) Self-diagnostic functions Unit WDT error, hardware errors (such as memory and CAN errors), and setting errors DeviceNet communications Duplicate node address errors, Bus OFF detection, and connection timeout Device profiles Communication control unit Refer to Appendix A of the WD30 DeviceNet Wireless Units Operation Manual for various DeviceNet IDs (vendor, device type = communication adapter, product code, product revision, product name, serial number, status, and I/O unit IDs.) Remote I/O Note: FINS message communications are not supported. Explicit messages must be handled in the ladder program. Refer to the WD30 DeviceNet Wireless Units Operation Manual for details. I/O Points Name DeviceNet Wireless Master DeviceNet Wireless Slave Number of I/O points (words used) 1,600 inputs max. (100 words) 1,600 outputs max. (100 words) 512 inputs max. (32 words) 512 outputs max. (32 words) Note: Relay Stations can be used to create up to 3 levels and DeviceNet Slaves can be connected in each level. s are required when Slaves are connected to a Relay Station or Slave Station. Refer to the WD30 DeviceNet Wireless Units Operation Manual for details on installation. Dimensions Note: All units are in millimeters unless otherwise indicated. WD30-ME and WD30-SE DeviceNet Wireless Units WD30-ME01 and WD30-SE01 DeviceNet Wireless Units WD30-AT001 Magnetic Base Antenna (Included with the WD30-ME01 and WD30-SE01.) 62 16 15 74 15 115 94 WD30--ME V1 WIRELESS UNIT No. 159 WD30--ME V1 WIRELESS UNIT No. 13.3 MS NS 85 MS NS WS 85 20 Cable length: 2,000 59.5 59.5 95.8 dia. 39 3.8 dia. 80 35 80 35 6 Precautions Refer to the WD30 DeviceNet Wireless Units Datasheet (Catalog No. M502-E1-@, M503-E1-@) or WD30 DeviceNet Wireless Units Operation Manual (Catalog No. M071-E1-@) for more detailed specifications. WD30 573

Wireless I/O Terminal WT30 Construct a Wireless System for ON/OFF Data Collection That Is Ideal for Monitoring Production Site Equipment Wireless Slave Station equipped with I/O. Height of 90 mm and DIN Rail mounting enables installation in control panels. Easily check wireless communications status from indicator display. I/O Slave Stations can also be used as Slave Stations in WD30 systems. Ordering Information List of Models Wireless Unit model Type /No. of I/O points WT30-M01-FLK Serial master RS-232C WT30-SID16 I/O slaves 16 DC inputs (NPN/PNP) WT30-SMD16 8 DC inputs (NPN/PNP) + 8 transistor outputs (NPN) WT30-SMD16-1 8 DC inputs (NPN/PNP) + 8 transistor outputs (PNP) Accessories Antennas Model WT30-AT001 WT30-AT002 WT30-AT003 Communications Cables Type Magnet-base Antenna (2 antennas per set) Flat Diversity Antenna (1 antenna) Pencil Antenna (2 antennas per set) Model Length Application XW2Z-0100U-3 1 m For personal computer XW2Z-0200U-3 2 m Model Length Application XW2Z-0500U-3 5 m XW2Z-0200U-5 2 m Cross cable for PLC XW2Z-0500U-5 5 m Other Model Type WT30-FT001 DIN Rail Mounting Bracket (for TH35-7.5) WT30-FT002 DIN Rail Mounting Bracket (for TH35-15) WT30-FT003 Surface Mounting Bracket (screw-mounting) (2 brackets per set) WT30-FT011 Flat Diversity Antenna Mounting Brackets (with magnets) WT30-CA2M Antenna Extension Cable (1 cable, 2 m) Applicable Countries Wireless standards have been met for the following countries. Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungry, Iceland, Ireland, Italy, Japan, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland, UK, USA 574 Remote I/O

General WT30-M01-FLK Serial Master WT30-SID16/SMD16/SMD16-1 I/O Slaves Power supply Rated voltage 24 V DC (wireless communications power sup- Allowable voltage range 20.4 to 26.4 V DC ply) Power consumption 3 W max. (See note 1.) /output power supply (for output circuits) Insulation resistance Rated voltage --- 24 V DC Allowable voltage range --- 20.4 to 26.4 V DC 20 MΩ min. (at 100 V DC) between the power supply and chassis 20 MΩ min. (at 100 V DC) between the power supply and all I/O and I/O power supply and between the power supply and chassis Dielectric strength 1,500 V AC for 1 min between power supply and chassis 1,500 V AC for 1 min between the power supply and all I/ O and I/O power supply and between the power supply and chassis Noise immunity IEC61000-4-4. 1 kv (power supply line) Vibration resistance (See note 2.) JIS C0040 Frequency: 10 to 55 Hz; Amplitude of 0.35 mm or acceleration of 50 m/s², whichever is smaller (DIN Rail mounting: single amplitude of 0.1 mm or acceleration of 15 m/s²) 10 sweeps of 8 min each (i.e., 80 min in total) in X, Y, Z directions Shock resistance Conforms to JIS C0041: 300 m/s2 3 times each in X, Y, and Z directions Ambient operating temperature Ambient operating humidity Ambient environment Storage temperature Protective structure Terminal construction Power supply and I/O Serial Safety standards Weight -10 to 55 C (with no condensation or icing) (with the Terminal mounted with the dust-proof label facing up) 25% to 85% (with no condensation or icing) No corrosive gases -25 to 65 C (with no condensation or icing) IP20 Screwless terminal block (Phoenix Contact FFKDS/V1-5.08 or equivalent) D-sub, 9-pin (female) Inch screws (OMRON XM2F-0910- --- 132 or equivalent), Master station only UL: UL508 (Listing) 330 g max. Number of simultaneously ON I/O points 10 max.: -10 to 55 C (with no condensation or icing) 16 max.: -10 to 50 C (with no condensation or icing) (with the Terminal mounted with the dust-proof label facing up) Remote I/O Note: 1. Provide a power supply of at least 15 W, considering the inrush current generated at startup. 2. Use the WT30-FT003 Surface Mounting Bracket when installing the WT30 in environments subject to vibration. Wireless Interface Wave type Communication method Frequency band Number of channels Transmitter output power Baud rate between wireless stations Communications distance (See note.) Error detection method Relay functions Number of stations per area (See note.) Number of I/O Slaves connected Spread Spectrum (direct sequence; DS-SS) Simplex 2,401 to 2,480.2 MHz 67 channels (based on switching) 10 mw/mhz 100 kbps Indoors: 60 m min. (approx. 50 m min. with Magnet-base Antennas and Flat Diversity Antennas) Outdoors: Approx. 300 m min. (anticipated distances) (without using relay stations) CRC-CCITT (16 bits) One stage using I/O slave for the serial master configuration. 10 sets max. (recommended) 64 max. Note: Varies according to the installation environment. WT30 575

Dimensions WT30-M01-FLK 13.3 105 13.3 WT30-SID16/SMD16/SMD16-1 105 120 (15) Four, 5 dia. 60 40 90 (15) Surface mounting bracket WT30-FT003 7.3 DIN rail mounting bracket WT30-FT001 or WT30-FT002 Wiring WT30-SID16 WT30-SMD16/SMD16-1 power supply (PNP) IN V G 0 1 2 3 COM 4 5 6 7 COM ERRP /output power supply (PNP) IN V G 0 1 2 3 COM 4 5 6 7 COM ERRP 24 V DC 0 V 8 9 10 11 COM 12 13 14 15 COM ERRN IN Power supply (NPN) 24 V DC 0 V 0 1 2 3 COM 4 5 6 7 COM ERRN OUT Power supply Outputs Outputs (NPN) 576 Remote I/O