Innovative Solutions. Screw Removal Technique

Similar documents
Surgical Technique. Acutrak Headless Compression Screw System

Instruments for Removing DePuy Synthes Screws. Screw Removal Set

Instruments for removing Synthes screws. Screw Extraction Set. Handling Technique

P O L A R I S. H a n d & F o o t. Headless Screw System PRODUCT INFORMATION

ISO Plate SURGICAL TECHNIQUE

Cannulated Screws Ø 3.5 mm / 4.5 mm

OPERATIVE TECHNIQUE RIVAL REDUCE FRACTURE PLATING SYSTEM. foot & ankle trauma procedures

OPERATIVE TECHNIQUE RIVAL BITE HEADED CANNULATED AND HEADLESS COMPRESSION SCREWS. foot & ankle applications

Table of Contents 2-6. Introduction. Indications Surgical Technique. Ordering Information 15-24

DART-FIRE. Small Screw System SURGICAL TECHNIQUE

HCS 2.4/3.0. The countersinkable compression screw.

DISTAL RADIUS PLATES 3.5 mm / ANGULARLY STABLE. Distal radius plates 3,5 mm / angularly stable. Locking bone screws. Cortical bone screw

DART-FIRE. Small Screw System SURGICAL TECHNIQUE

Integra. Capture Screw System SURGICAL TECHNIQUE

The Percutaneous Reduction Forceps Technique Guide

UJAM AA O RTHO PTY LTD 100 HYDE PARK C LO SE HYDE PARK 2196 W W W.UJAM AAO RTHO.C O M

DART-FIRE. Small Screw System SURGIC A L T ECHNIQUE

Small Plate and Screw System SURGICAL TECHNIQUE

Technique Guide. 7.0 mm Cannulated Screws. Part of the Synthes Cannulated Screw System.

4.0 CANNULATED SCREW SYSTEM

Screw Removal Set

1.5 MM LCP SYSTEM. For treatment of fractures and arthrodeses of canines and felines SURGICAL TECHNIQUE

MEDICAL ADVANCED TECHNOLOGY EMERGENCY REMOVAL UNIVERSAL EXTRACTION SET. for Intramedullary Nail System

BioDrive Micro Screw System

DLS Dynamic Locking Screw. Combined with LCP Locking Compression Plate.

MaxTorque. surgical technique. Cannulated Screw System. Foot & Ankle. OrthoHelix Technology

PRODUCT SUMMARY. 80 Total Angulation

SpeedTip CCS 5.0, 7.0

Titanium Modular Hand System. For fractures, replantations and reconstruction of the hand.

TwinFix Surgical Protocol. 3.2mm Cannulated Compression Screw System

Mecron Cannulated Screws

2.4 mm and 3.0 mm Headless Compression Screws

Technique Guide. 4.5 mm Cannulated Screws. Part of the Synthes Cannulated Screw System.

Ankle Fracture System. Surgical Technique STRENGTH FROM WITHIN

MTP Fusion Surgical Technique

Surface Vise 05G10.50

7.0 mm Cannulated Screws

3.5 mm Cannulated Screw Technique Guide

Technique Guide. Cable System. For Orthopaedic Trauma Surgery.

MTP Set SURGICAL TECHNIQUE

Peanut Growth Control Plating System. Surgical Technique

Technique Chart. DHS/DCS One-Step Insertion Wrench. For use with DHS/DCS One-Step Lag Screws.

Instructions for Use. LCP Locking Compression Plate. Combine without Compromise.

Technique Guide Supplement. Standard DHS Lag Screw with LCP DHHS Sideplate.

Part of the DePuy Synthes Cannulated Screw System. 3.5 mm Cannulated Screws

The information contained in this document is intended for healthcare professionals only.

CHARLOTTE CLAW Plate Compression Locking Arthrodesis by Wright SURGICAL TECHNIQUE

VLP FOOT Variable Angle Locked Plating System

Treace Medical Concepts Plating System

CHARLOTTE. Multi-Use Compression Screw

VECTRA SURGICAL TECHNIQUE. Anterior cervical plate system. This publication is not intended for distribution in the USA.

Ascent. Posterior Occipital Cervico-Thoracic (POCT) System

RC4WD R2 Disconnect Transmission parts replacement guide

Technique Guide. LCP Pilon Plate 2.7/3.5

6.5 mm and 7.3 mm Cannulated Screws Technique Guide

HDL(M)6 Nut/Screw Assembly

Surgical Technique 1

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

5th Metatarsal Fracture System Surgical Technique

Extracts without expanding material Ideal for pipes and fittings Works on left-hand or right-hand threads

Anterior Cervical Plate SURGICAL TECHNIQUE GUIDE. Surgeon Driven Innovation

Manuals are subject to change; the most current version of each manual is always available online. Printed on: November 25, 2015

Aviator Anterior Cervical Plating System System Overview. Visual and tactile confirmation Increased Angulation Simplified instrumentation

MINI INSTRUMENTS & IMPLANTS

Video Wall Installation Instructions 2W X 3H, 3W X 3H

No-Mar tip conversion/replacement procedure

INSTALLATION OF WELLS SUPER QUICK CHUCK LEFT HAND ON BALDOR LATHE

Ulna Shortening System 2.5

HCS 1.5. The countersinkable compression screw.

Arthrex. Bio-Compression. Screw System. Knee OCD. Hand, Wrist & Elbow. Foot & Ankle

Integra. Stainless Headed Compression Screw System SURGICAL TECHNIQUE

LCP Pilon Plate 2.7/3.5

64 SECUROS Orthopedic Resource Guide 1 (877) BONEFIX ( )

Small Fragment Locking Compression Plate (LCP ) System Stainless Steel and Titanium TECHNIQUE GUIDE

TOOLS AND INSTALLATION

Standard Kit #1 (5-way switch)

PRE-OPERATIVE PREPARATIONS

Vortex TRAUMATOLOGY. Vortex Distal Femur

IDR assembly instructions:

For the Reduction of Displaced Craniofacial Fractures. Threaded Reduction Tools and T-Handle

Proximal Humerus System 3.5

EllisSaw.com. EllisSaw.com P.O. Box Verona, WI

Surgical Technique ANAX TM OCT. Spinal System

OPERATIVE TECHNIQUE RIVAL VIEW PLATING SYSTEM. foot & ankle reconstruction procedures

Fibula Plating System

Sentinel Series Cigar Humidor End Tables

Written By: Thomas Opsomer

SpeedTip CCS 5.0, 7.0

Bio-Compression. Arthrex. Screw System

Grizzly Drill Press SOP

Biomet Peritrochanteric Nail (PTN) System. Surgical Technique

Surgical Technique Guide

3.5 mm/2.7 mm LCP. Pancarpal Arthrodesis Plate. For treatment of carpal joints in dogs

LCP Pilon Plate 2.7/3.5

Back to health. Back to work. Back to life.

Important Loading Information. Tools Required. Meridian Lateral Files Instructions

3.5 mm/ 2.7 mm LCP. PanCarPaL arthrodesis S PLate. BroCHUre. For treatment of carpal joints in dogs

8.0 RE-CALIBRATION OF SPACE

SCULL HANDLES AND GRIPS INSTRUCTION BOOKLET

RTI TECHNOLOGIES, INC.

Transcription:

Innovative Solutions Screw Removal Technique

Screw Removal Introduction Acumed is an industry leader in innovations for extremities and trauma. We are dedicated to pioneering solutions that benefit the patient and drive the industry forward. CONTENTS Screw Removal Introduction 2 Features and Benefits 3 Screw Removal Usage Chart 4 Acutrak Screw Removal Technique 5-6 Plate Screw Removal Surgical Technique 8-9 Acutrak Screw Removal Ordering Information 10 Plate Screw Removal Ordering Information 11 The Acumed Screw Removal system allows you to remove any Acumed bone Plate or Acutrak Headless Compression Screw with ease. The system is a complement to our innovative Acumed bone plates and Acutrak Headless Compression Screws. Each component of the extensive system is designed specifically for our bone plates and Acutrak Screws, with customized geometry to exactly match our products. The versatility of the system allows you to use the instrumentation in any screw removal situation you are presented with in the operating room. The Acumed Screw Removal system is part of our ongoing commitment to support all your orthopaedic cases, whether it s insertion or removal. Solid Hex Driver Designed with stronger material for reduced stripping Cannulation removed to increase strength Easyout Cutting flutes to grasp stripped hex Ideal geometry for screw removal Left-Handed Drills Tip specifically designed for drilling titanium implants 2

Features and Benefits Customized for Optimal Performance The distinct geometry of Acumed Screw system is tailored to match our product line to enable efficient removal in any situation. Ease of Use All of our removal instrumentation is easy to assemble and use. AO quick releases are provided on all instrumentation to help shorten the case. Trephine Thin wall to remove less bone Tapered interior to encapsulate proximal portion of screw Screw Removal Tip Force fit on threads to lock the screw Impact Driver For use with Acutrak Plus, Acutrak 6/7 and Acutrak 2-5.5 Headless Compression Screws 3

Screw Removal Tool Usage Chart Solid Drivers Easyouts Left-Handed Drills Screw 80-0583 (1.5 mm) 80-0632 (2.0 mm) HPC0025 (2.5 mm) 80-0633 (3.0 mm) 80-0634 (3.5 mm) 80-0635 (4.0 mm) 80-0636 (Cruciform) 80-0598 (1.5 mm) 80-0599 (2.0 mm) 80-0600 (2.5 mm) 80-0601 (3.0 mm) 80-0602 (3.5 mm) 80-0604 (4.0 mm) 80-0399 (1.5 mm) 80-0400 (2.0 mm) 80-0401 (2.5 mm) 80-0402 (3.0 mm) 80-0403 (3.5 mm) 80-0404 (4.0 mm) Acutrak Mini Acutrak Standard< 20 mm Acutrak Standard > 20 mm Acutrak 4/5 Acutrak Plus Acutrak 6/7 Acutrak 2 Micro Acutrak 2 Mini Acutrak 2 Standard Acutrak 2-5.5 2.3 CO Screws 2.7 CO, COL and Tap-Loc Screws 3.5 CO, COL and Tap-Loc Screws Cruciform Screws Trephines Removal Tips Impact Drivers Screws 80-0205 80-0206 80-0207 80-0208 80-0209 80-0210 80-0211 80-0212 80-0213 80-0214 80-0216 80-0217 80-0612 80-0613 80-0614 80-0615 80-0616 80-0605 (3.0 mm) 80-0606 (4.0 mm) Acutrak Mini Acutrak Standard< 20 mm Acutrak Standard > 20 mm Acutrak 4/5 Acutrak Plus Acutrak 6/7 Acutrak 2 Micro Acutrak 2 Mini Acutrak 2 Standard Acutrak 2 5.5 2.3 CO Screws 2.7 CO, COL and Tap-Loc Screws 3.5 CO, COL and Tap-Loc Screws Cruciform Screws 4

Acutrak Screw Removal Steps Screw is not broken Solid Drivers Easyouts Trephines Removal Tips Impact Drivers 3.0 and 4.0 Hex sizes only Hex is stripped Screw is broken Proximal Solid Drivers Easyouts Trephines Removal Tips Impact Drivers 3.0 and 4.0 Hex sizes only Distal Left-Handed Drills 5

Acutrak Screw Removal Technique The Acumed Screw Removal system is designed for easy and efficient screw removal. The following pages detail proper removal techniques, including simple tips and guidelines for removing screws when there is resistance or other difficulties. 1Using the Driver Clean out the hex in the screw. Using the solid hex driver, try to remove the screw. It may help to advance the screw approximately a quarter turn to break the bond between the titanium and the bone. Turn the driver slowly and firmly making sure to keep the driver in line with the screw. If there is resistance or a risk of breakage, proceed to the next step. 2Using the Easyouts Make sure the hex is clear. The easyouts should be turned by hand. Turn the easyout counter-clockwise with firm constant pressure in line with the screw. It may help to offset the easyout by a couple of degrees so it wedges into the head of the screw. If the easyout is spinning, tap it with a mallet to move it further inside the hex. If the easyout doesn t engage the hex or strips the hex, proceed to the next step. 3 Using the Trephines The trephines are designed for specific screws and for coring small amounts of bone away from the screw while internally engaging on the threads of the screw. The trephines need to be used under power, at low rpm s, high pressure and in reverse. A guide wire may be used to help line up the trephine, which is cannulated, but it is not required. If using a guide wire, insert the guide wire into the screw s cannulation and then place the trephine over the guide wire and push down until it contacts the bone around the screw. If not using a guide wire just place the trephine over the end of the screw. If the trephine engages the screw, the screw will start to back out of the hole. Keep rotating until the screw is completely out of the hole. If the trephine doesn t engage the screw, stop and proceed to the next step. The removal tip is designed to fit in the core created by the trephine. 6

Acutrak Screw Removal Technique 4Using the Removal Tip Thread the removal tip on the end of the supplied quick release shaft and place over the screw. The screw removal tip should be used by hand. Firmly tap the tip onto the end of the screw. A mallet may be used to make sure the tip is firmly attached to the screw. Rotate the tip counter clockwise until the screw is removed. 5Using the Left-Handed Drill If the screw is broken and the proximal portion of the screw is removed, assess the amount of the screw that is left. If you have more than half of the screw, use the same size left-handed drill as the hex size of the screw you are removing. If you have less then half of the screw, use the next smallest left-handed drill. Using the drill in reverse, insert the drill tip into the cannulation of the fragment. With a low to medium drill speed and high pressure, drill out the cannulation to a depth of approximately 4 mm to 5 mm. The drill flutes may serve to remove the fragment. If the drill does not remove the fragment, use the same size easyout to remove it. 6Using the Impact Drivers The impact drivers are designed to be used with Acutrak Plus, Acutrak 6/7 and Acutrak 2-5.5 screws. They should only be used if all the preceding removal steps did not remove the screw. To use the impact driver, place the tip of the impact driver in the screw hex. Place the impact driver handle over the hex end of the impact driver. Using a mallet lightly tap the impact driver to wedge the tip into the screw hex. Rotate the impact driver counter-clockwise until the screw is removed. 7

Plate Screw Surgical Technique Techniques for plate screw removal are similar to those of Acutrak Screw removal, but not exactly the same. So be sure to carefully follow the tips and guidelines as described. 1Using the Driver Clean out the hex in the screw. Use the solid hex driver to try and remove the screw. It may help to initially try and advance the screw approximately a quarter turn to break the bond between the titanium and the bone. Turn the driver slowly and firmly making sure to keep the driver in line with the screw. If there is resistance or a risk of breakage, proceed to the next step. 2Using the Easyouts Make sure the hex is clear. The easyouts should be turned by hand. Turn the easyout counter-clockwise with firm constant pressure in line with the screw. It may help to offset the easyout by a couple degrees so it wedges into the head of the screw. If the easyout is spinning, tap it with a mallet to get it further inside the hex. If the easyout does not engage the hex or if there is a risk of splitting, proceed to next step. 3Using the Left-handed Drill Use the left-handed drill inverse to remove the head of the screw. The drill may act as an easyout and remove the screw instead of removing the head. Regardless, you should remove the plate from the bone. If one of the screws could not be removed and the drill did not remove the head, use a burr to cut the plate on either side of the remaining screw and then remove the plate. Use suction to vacuum up the chips. Once the plate is removed go to the next step. 8

Plate Screw Surgical Technique 4Using the Trephines The trephines are designed for specific screws and for coring small amounts of bone away from the screw while internally engaging on the threads of the screw. The trephines need to be used under power, at low rpm s, high pressure and in reverse. A guide wire may be used to help line up the trephine, which is cannulated, but it is not required. If using a guide wire, insert the guide wire into the screw s cannulation and then place the trephine over the guide wire and push down until it contacts the bone around the screw. If not using a guide wire just place the trephine over the end of the screw. If the trephine engages the screw, the screw will start to back out of the hole. Keep rotating until the screw is completely out of the hole. If the trephine doesn t engage the screw, stop and proceed to the next step. The removal tip is designed to fit in the core created by the trephine. 5Using the Removal Tip Thread the removal tip on the end of the supplied quick release shaft and place over the screw. The screw removal tip should be used by hand. Firmly tap the tip onto the end of the screw. A mallet may be used to make sure the tip is firmly attached to the screw. Rotate the tip counter-clockwise until the screw is removed. CO & COL Screw Plates Screw Removal Steps Solid Drivers Easyouts Left-Handed Drills Trephines Removal Tips If the easyout does not engage the hex, drill off the head of the screw and remove the plate. You can then use trephines to remove screws. 9

Acutrak Removal Ordering Information Acutrak Screw Removal Part # Qty Per Set 1.5 mm Quick Release Solid Hex Driver 80-0583 2 2.0 mm Quick Release Solid Hex Driver 80-0632 2 2.5 mm Quick Release Solid Hex Driver HPC-0025 2 3.0 mm Quick Release Solid Hex Driver 80-0633 2 3.5 mm Quick Release Solid Hex Driver 80-0634 2 4.0 mm Quick Release Solid Hex Driver 80-0635 2 1.5 mm Easy Out 80-0598 2 2.0 mm Easy Out 80-0599 2 2.5 mm Easy Out 80-0600 2 3.0 mm Easy Out 80-0601 2 3.5 mm Easy Out 80-0602 2 4.0 mm Easy Out 80-0603 2 1.5 mm Left-Handed Drill 80-0399 2 2.0 mm Left-Handed Drill 80-0400 2 2.5 mm Left-Handed Drill 80-0401 2 3.0 mm Left-Handed Drill 80-0402 2 3.5 mm Left-Handed Drill 80-0403 2 4.0 mm Left-Handed Drill 80-0404 2 Acutrak Mini Trephine 80-0210 2 Acutrak Standard Trephine < 20 mm 80-0209 1 Acutrak Standard Trephine> 20 mm 80-0208 1 4/5 Trephine 80-0207 2 Plus Trephine 80-0206 2 6/7 Trephine 80-0205 2 Acutrak 2 Standard Trephine 80-0211 2 Acutrak 2 Mini Trephine 80-0212 2 Acutrak 2 Micro Trephine 80-0213 2 Acutrak 2-5.5 Trephine 80-0214 2 3.0 mm Impact Driver Tip 80-0605 1 4.0 mm Impact Driver Tip 80-0606 1 Micro Removal Tip 80-0612 3 Mini Removal Tip 80-0613 3 Standard Removal Tip 80-0614 3 Large Removal Tip 80-0615 3 Extra Large Removal Tip 80-0616 3 Screw Removal Tip Shaft 80-0610 1 Removal Tip Wrench 80-0611 1 Impact Driver Handle 80-0607 1 Vise Grips Teleflex: KM48600 80-0617 1 T-Handle, Silicone, A-O Connector 80-0637 1 Periosteal Elevator MS-46211 1 Sharp Hook PL-CL06 1 Acutrak & Acutrak 2 Screw Removal Tray Assembly 80-0586 1 10

Plate Screw Removal Ordering Information Plate Screw Removal Part # Qty per Set 3.5 CO Trephine 80-0216 2 2.7-2.3 CO Trephine 80-0217 2 2.5 mm Left-Handed Drill 80-0401 2 3.0 mm Left-Handed Drill 80-0402 2 1.5 mm Solid Hex Driver Tip, Quick Release 80-0583 2 1.5 mm Easy Out 80-0598 4 2.5 mm Easy Out 80-0600 4 Screw Removal Tip Shaft 80-0610 1 Removal Tip Wrench 80-0611 1 Micro Removal Tip 80-0612 6 Mini Removal Tip 80-0613 6 Locking Pliers, Small 80-0617 1 Cruciform Driver Tip, Quick Release 80-0636 2 T-Handle, Small, Fixed, Quick Release Connector 80-0637 1 2.5 mm Quick Release Solid Hex Driver HPC-0025 2 Periosteal Elevator MS-46211 1 Sharp Hook PL-CL06 1 Universal Tray Plate & Screw Removal Assembly 80-0474 1 To order products or for more information on the full line of Acumed innovative surgical solutions, please contact your local Acumed Sales Representative. www.acumed.net 11

5885 NW Cornelius Pass Road Hillsboro, OR 97124 (888) 627-9957 www.acumed.net Distributed by: Effective 4/2011 SPF10-00-A 2011 Acumed LLC These materials contain information about products that may or may not be available in any particular country or may be available under different trademarks in different countries. The products may be approved or cleared by governmental regulatory organizations for sale or use with different indications or restrictions in different countries. Products may not be approved for use in all countries. Nothing contained on these materials should be construed as a promotion or solicitation for any product or for the use of any product in a particular way which is not authorized under the laws and regulations of the country where the reader is located. Specific questions physicians may have about the availability and use of the products described on these materials should be directed to their particular local sales representative. Specific questions patients may have about the use of the products described in these materials or the appropriateness for their own conditions should be directed to their own physician.