Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014

Similar documents
Photons and solid state detection

Last class. This class. CCDs Fancy CCDs. Camera specs scmos

Welcome to: LMBR Imaging Workshop. Imaging Fundamentals Mike Meade, Photometrics

Engineering Medical Optics BME136/251 Winter 2018

CCDS. Lesson I. Wednesday, August 29, 12

Lecture 12 OPTICAL DETECTORS

Camera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note

Optical Receivers Theory and Operation

Redefining Measurement ID101 OEM Visible Photon Counter

CCD Characteristics Lab

Electron-Multiplying (EM) Gain 2006, 2007 QImaging. All rights reserved.

Components of Optical Instruments

OFCS OPTICAL DETECTORS 11/9/2014 LECTURES 1

Fundamentals of CMOS Image Sensors

Ground-based optical auroral measurements

Charged Coupled Device (CCD) S.Vidhya

Page 1. Ground-based optical auroral measurements. Background. CCD All-sky Camera with filterwheel. Image intensifier

Control of Noise and Background in Scientific CMOS Technology

CCD Analogy BUCKETS (PIXELS) HORIZONTAL CONVEYOR BELT (SERIAL REGISTER) VERTICAL CONVEYOR BELTS (CCD COLUMNS) RAIN (PHOTONS)

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons

2013 LMIC Imaging Workshop. Sidney L. Shaw Technical Director. - Light and the Image - Detectors - Signal and Noise

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

Tutors Dominik Dannheim, Thibault Frisson (CERN, Geneva, Switzerland)

Charged-Coupled Devices

Photodiode: LECTURE-5

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

A Measurement of the Photon Detection Efficiency of Silicon Photomultipliers

How Does One Obtain Spectral/Imaging Information! "

Electron-Bombarded CMOS

Properties of a Detector

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

IV DETECTORS. Daguerrotype of the Moon, John W. Draper. March 26, 1840 New York

Based on lectures by Bernhard Brandl

Single-Photon Counting Detectors for the Visible Range Between 300 and 1,000 nm

An Introduction to CCDs. The basic principles of CCD Imaging is explained.

light sensing & sensors Mo: Tu:04 light sensing & sensors 167+1

The Benefits of Photon Counting... Page -1- Pitfalls... Page -2- APD detectors... Page -2- Hybrid detectors... Page -4- Pitfall table...

Light Collection. Plastic light guides

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 20

EE 392B: Course Introduction

High Performance. Image Intensifiers

Light Microscopy for Biomedical Research

Production of HPDs for the LHCb RICH Detectors

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Silicon sensors for radiant signals. D.Sc. Mikko A. Juntunen

Advancement in development of photomultipliers dedicated to new scintillators studies.

TDI Imaging: An Efficient AOI and AXI Tool

Direct Measurement of Optical Cross-talk in Silicon Photomultipliers Using Light Emission Microscopy

CHAPTER 11 HPD (Hybrid Photo-Detector)

The new CMOS Tracking Camera used at the Zimmerwald Observatory

Lecture 7. July 24, Detecting light (converting light to electrical signal)

Electron Multiplying Charge-Coupled Devices

High collection efficiency MCPs for photon counting detectors

An Introduction to the Silicon Photomultiplier

A new Photon Counting Detector: Intensified CMOS- APS

Detectors for Sensitive Detection: HyD

UNIT VIII-SPECIAL PURPOSE ELECTRONIC DEVICES. 1. Explain tunnel Diode operation with the help of energy band diagrams.

Scintillation Counters

Acquisition. Some slides from: Yung-Yu Chuang (DigiVfx) Jan Neumann, Pat Hanrahan, Alexei Efros

A new Photon Counting Detector: Intensified CMOS- APS

Radiation transducer. ** Modern electronic detectors: Taking the dark current into account, S = kp + bkgnd over the dynamic range.

Characterisation of SiPM Index :

Where detectors are used in science & technology

Silicon Photomultiplier

The Charge-Coupled Device. Many overheads courtesy of Simon Tulloch

EM-CCD Technical Note (Dec./2009)

Introduction to Image Intensifier Tubes

Detectors for Optical Communications

The Role of Detectors in Spectroscopy

Recent Development and Study of Silicon Solid State Photomultiplier (MRS Avalanche Photodetector)

Chapter 3 OPTICAL SOURCES AND DETECTORS

Week 9: Chap.13 Other Semiconductor Material

The Design and Construction of an Inexpensive CCD Camera for Astronomical Imaging

Digital Imaging Rochester Institute of Technology

Advanced Camera and Image Sensor Technology. Steve Kinney Imaging Professional Camera Link Chairman

High Performance. Image Intensifiers

Development of Photon Detectors at UC Davis Daniel Ferenc Eckart Lorenz Alvin Laille Physics Department, University of California Davis

STA1600LN x Element Image Area CCD Image Sensor

Photomultiplier & Photodiode User Guide

Time Delay Integration (TDI), The Answer to Demands for Increasing Frame Rate/Sensitivity? Craige Palmer Assistant Sales Manager

Gamma Spectrometer Initial Project Proposal

Introduction to CCD camera

the need for an intensifier

ICMOS: Intensified CMOS Camera for Biological Applications. Diana Hilton

Leica TCS SP8 Quick Start Guide

Charge-Coupled Device (CCD) Detectors pixel silicon chip electronics cryogenics

High Resolution BSI Scientific CMOS

Chemistry Instrumental Analysis Lecture 7. Chem 4631

Three Ways to Detect Light. Following: Lord Rosse image of M33 vs. Hubble image demonstrate how critical detector technology is.

Development of New Large-Area Photosensors in the USA

BSI scmos 400BSI. Super Signal to Noise Ratio NEW

Overview. Charge-coupled Devices. MOS capacitor. Charge-coupled devices. Charge-coupled devices:

Image acquisition. In both cases, the digital sensing element is one of the following: Line array Area array. Single sensor

Advances in microchannel plate detectors for UV/visible Astronomy

SiPMs for solar neutrino detector? J. Kaspar, 6/10/14

Light gathering Power: Magnification with eyepiece:

Direct Measurement of Optical Cross-talk in Silicon Photomultipliers Using Light Emission Microscopy

THE CCD RIDDLE REVISTED: SIGNAL VERSUS TIME LINEAR SIGNAL VERSUS VARIANCE NON-LINEAR

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

You won t be able to measure the incident power precisely. The readout of the power would be lower than the real incident power.

Transcription:

Detectors for microscopy - CCDs, APDs and PMTs Antonia Göhler Nov 2014

Detectors/Sensors in general are devices that detect events or changes in quantities (intensities) and provide a corresponding output, generally as an electrical or optical signal What do we expect of a sensor while taking an image? speed as fast as possible work within a wide range of light levels good dynamic range work at different emission wavelength enough resolution to see details low noise level (good signal-to-noise ratio)

Sensitivity A sensor's sensitivity indicates how much the sensor's output changes when the input quantity being measured changes (ratio between output signal and measured property) Sensitivity is a horrible word which is often confused with Quantum Efficiency, Pixel Size, Signal and Signal to Noise some key facts: Photons convert to electrons in sensors and they can then be measured this conversion rate is defined as Quantum Efficiency Sensors convert photons of some wavelengths better than others The number of photons that interact with a pixel depend on the physical size of the pixel We can have a sensitive sensor but if our signal to noise is low we get a noisy image with data we cannot decipher

Quantum Efficiency (QE) QE is a measure of the effectiveness of an imager to produce electronic charge from incident photons The wavelength of incoming light and photon absorption depth are directly related; the shorter the wavelength, the shorter the penetration depth into the silicon Incoming Light e - e - e - e - e - e - e - e - e - e - Electronical Connection Polysilicon Gate Silicon Dioxide Silicon Potential Well

What is actually happening at each pixel? 1. Photon hits the CCD sensor 2. is then converted to an Electron 3. and digitised using an Analogue to Digital converter (ADC) 4. Electron value is now converted to a grey scale 5. User measures grey scale (ADU)

Different Detector Types CCD Charged Coupled Device EMCCD Electron Multiplied CCD CMOS Complementary Metal Oxide Semiconductor PMT Photon Multiplier Tube APD Avalanche Photodiode

CCD Fundamentals Invented in 1970 at Bell Labs A silicon chip that converts an image to an electrical signal Image is focused directly onto the silicon chip Widely used in TV cameras and consumer camcorders

Bucket Brigade Rainfall Analogy rain intensity may vary from place to place parallel buckets on a conveyor belt transported stepwise to a row of empty serial buckets serial buckets move on a second conveyor oriented perpendicularly to the first accumulated rainwater in each bucket is transferred sequentially into a calibrated measuring container ( = CCD output amplifier) process is repeated until all parallel buckets are shifted to the serials

Readout of a CCD camera shutter is opened to begin accumulation of photoelectrons end of the integration period = shutter is closed accumulated charge is shifted row by row across the parallel register into the serial register charge contents of serial pixels are transferred into an output node to be read by an on-chip amplifier, which boosts the electron signal and converts it into an analog voltage output an ADC assigns digital value for each pixel according to its voltage each pixel value is stored in computer memory or camera frame buffer serial readout process is repeated until all pixel rows of the parallel register are emptied CCD is cleared of residual charge prior to the next exposure

Camera Noise is uncertainty is plus or minus (not additive) is driven by statistics can be calculated is not background standard deviation is an easy way for us to measure noise noise exists on every camera and in every measurement dependent on the image scale used you may or may not see it noise distorts measurements and increases the uncertainty in measurements.

Noise Sources 1. Dark Current noise from heat and cosmic noise exposure dependent (less important) 2. Read Noise noise of reading the signal fixed 3. Photon Shot square route of signal signal dependent (Poission distributed) SNR = S QE (S QE) 2 +DC + σ R 2 S =Signal in Photons (converted to electrons by * QE) QE = Quantum Efficiency of light at that emission D = Dark Current Noise = Dark Current * Exposure Squared σ R = Read Noise

EMCCD- Electron Multiplied CCD based on CCD technology addition of an Electron Multiplication register ( gain register between the usual serial shift register and the output amplifier) enabling higher signals relative to the fixed camera noise issues with EMCCDs EM Gain decay Bias Stability EM Gain Stability (aging) Back ground events dark current Excess Noise Factor (uncertainty due to unpredictable multiplication of electrons)

Front- and Backside-Illumination, Intensified CCD Frontside Backside Photocathode MCP Phospher Screen Fiber Optics A back-illuminated sensor orientates the wiring behind the photocathode which improves the chance of an input photon being captured from about 60% to over 90%. An ICCD is a CCD that is optically connected to an image intensifier sitting in front of the CCD

Excursus: Photomultiplier Tube (PMT) constructed from a glass envelope with a high vacuum inside, which houses a photocathode, several dynodes, and an anode photons produce electrons at the photocathode (photoelectric effect) electrons are multiplied by the process of secondary emission (amplification 10 8 )

MCP Microchannel Plate MCP Channel Incident Electron Channel Wall Output Electrons (thousands times) VD Each channel in the MCP is a secondary electron multiplier, multiplying electrons with each bounce off the channel wall

PMT release electrons with a peak quantum efficiency of about 40 % the photocathode active area ranges in size from a few millimeters to a half meter in diameter, depending upon the application. commonly used in applications without spatial resolution Photomultiplier tubes (PMTs) are widely used in confocal microscopes and high-end automatic exposure bodies for film cameras as well as in spectrometers because PMTs do not store charge and respond to changes in input light fluxes within a few nanoseconds, they can be used for the detection and recording of extremely fast events typically generate low noise values (and dark current) resulting in a huge dynamic range over which electrical current output still accurately reflects the photon flux

CMOS - Complementary metal-oxide-semiconductor CMOS technology, as CCD, uses an array of light sensitive pixels to collect full area image CMOS technology differs by completing all digitisation at the pixel point (faster) CMOS sensors require around 100x less power than CCD making them the perfect choice for camera phone sensors low costs disadvantages: small pixels so low dynamic range, high noise level, Rolling shutter, lower QE

CMOS goes Scientific (scmos) in 2009 manufacturers launched a camera technology called SCMOS (scientific CMOS) a new sensor type with low noise less than 2e read noise high speed 100 fps high QE 55-70% high resolution 2-5 million pixel BUT: Noise/Uncertainty occurs with the readout and digitization of each pixel s signal noise is not longer Gaussian distributed (random telegraph noise) rolling shutter (distortion of moving objects, poor synchronization with changing illumination experiments)

Summary CCD cameras have been the standard for general microscopy applications for many years and will continue to be the best choice for a variety of applications from colour imaging and fixed sample fluorescence to long stare applications EMCCD cameras continue to offer the best solution when imaging at very low light levels with speed, for example single molecule fluorescence SCMOS is a new addition to the sensors available for microscopy when speed is key. Combining this with great sensitivity a large field of view and low noise. Well suited to applications such as SPIM.

PIN - Diode PIN-Diode Incident photon creates an electron-hole pair (inner photoelectric effect) holes move toward the anode, and electrons toward the cathode, and a photocurrent is produced. The total current through the photodiode is the sum of the dark current PIN = high-level injection = electric field extends deeply into this region

APD Avalanche Photodiode APDs are similar to regular PIN diodes but operate with much higher revers bias have an additional heavily doped p- or n-region which allows an amplification (avalanche multiplication) acceleration of charge carriers in depletion region and generation of new secondary charge carriers via impact ionization (like PMTs) because of high revers voltage (close to breakdown voltage) of several 100V high magnifications of primary charge carriers for voltages bigger then the breakdown voltage = avalanche effect = amplification 10 6

APD Some Key Facts active area 1 mm 2 and 10 µm x 10 µm for a high-speed APD. It is therefore difficult to focus the fluorescence onto the APD, so the sensitivity is too low for most measurements. dead times of 100ns, wavelength dependent, event rates ca. 10MHz routinely used for TCSPC, especially in applications where the emission can be tightly focused, such as single-molecule detection (SMD) and fluorescence correlation spectroscopy (FCS) APDs have high quantum efficiencies at real wavelengths, and are the detector of choice for these applications.

The End!