Aquaflex Universal Soil Moisture Sensor (Model SI.162-mA) -User Manual- ma Version -

Similar documents
Aquaflex Universal Soil Moisture Sensor (Model SI.162-mA) -User Manual- ma Version -

Aquaflex Universal Soil Moisture Sensor (Model SI.162-Pulse) -User Manual- Pulse Version -

Aquaflex Soil Moisture Sensor (SI.60) -User Manual-

Soil Moisture Smart Sensors (S-SMx-M005)

Flex Fence Instruction Manual

ClearSpan PolyMax Windbreak Wall

FENCE INSTALLATION GUIDE 8 HIGH WALLS

M E E T I N S T R U M E N T A T I E MAS ma Soil Moisture Sensor. User Manual. Version 4

Raceline / Shockline/Endloop Installation Manual

ACE 250 Key Features. 18 Garrett Metal Detectors

ARTIFICIAL GRASS GENERAL PROJECT INSTALLATION TIPS. Buy or Rent HAND TOOLS & POWER EQUIPMENT. SHOP ONLINE or AT YOUR LOCAL HOME DEPOT STORE

ALUMINUM FENCE. Additional freight charges may apply depending on order size. Please call for quote at

automatic embosser & die cutter USER MANUAL

Build your own. Pack. Stages 19-22: Continue building Robi s left arm

Tapecoat. Application Guideline

Installation Instructions. Tools Needed. Tape measure. Level. Shovel or Post hole digger. Concrete. Drill. Stakes. Mallet or hammer.

Spring Quilling. By Eileen Walters. Materials Required: To Make The Card: Daffodils:

Welcome to the DIY Thirsty Plant Kit - Manual

Ready-To-Assemble VersaRail INSTALLATION INSTRUCTIONS

PRIVACY FENCE WITH LATTICE INSTALLATION INSTRUCTIONS

Ranch Rail Vinyl Fence

Q-Zone Hoop-Frame. Assembly Instructions. Copyright July 11, 2018 Grace Company (Reproduction Prohibited) Version 1.8

WELDING. Section nine 9.1 CORRECT TOOLS

6a. Eight Steps to Chain-Link Fence Installation

Please Do Not Return This Product To The Store!

PATRIOT DOCKS ASSEMBLY INSTRUCTIONS

PRIVACY FENCE WITH SCALLOPED PICKET INSTALL INSTRUCTIONS

15mm Solid European Droploc Oak Fitting Guide & Warranty Information

Owner s Manual. FT100X. 4ft Folding Football Table. Manual version 2.1

Mount to the Wall INSTALLATION MANUAL

Explorer Wiring Kit (assembled)

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

MFJ-203 Bandswitched Dip Meter

TRAMPOLINE A SSEMBLY I N S T RUC T I ONS

NEVADA ASSEMBLY INSTRUCTIONS

FENCE INSTALLATION GUIDE 6 HIGH FENCE

Making Ethafoam Preservation Rollers for Storing East Asian Scrolls

U. M. ARMY Texas Conference. Wheel Chair Ramp Manual

3 Dynatel M Series Locating and Marking System DOCUMENT NEW- TO- THE- WORLD TECHNOLOGY OBSOLETE DAMAGE PREVENTION PIN- POINT ACCURACY SAFETY

Sailcloth Fabric Replacement Top and Doors with Tinted Side and Rear Curtains Installation Instructions

TABLE OF CONTENTS. 1. Introduction Operation System Service Reference Index... 18

INSTALLATION INSTRUCTIONS

Chapter 6 Frame And Lens Repairs

1. Layout. Step 1. Step 2. Step 3. Fig. 1

MUDPLASTERED BAMBOO-SHELTER as temporary dwelling until the real house can be built can last for 6-8 years

Big Oz. Rocket. User Guide V0313

E N G L I S H GARDEN SHED. Assembly Instructions. Suitable for Models WITH VARYING DEPTHS

GC-1032 Metal Detector OWNER S MANUAL

WaterScout SM100 Soil Moisture Sensor Catalog # 6460

Instructions For Installing A Pig Fence

Tauten Tab Tension Screen User Manual

WARNING: Be sure you have read and understood the Safety Information sheets before you begin your pool installation.

4S, 5S, 5A, 6S, 6A, 8S, 9S, 10S, 10A, 26S, 29S, 35S, 35A, 36S,

Golden Mask Deep Hunter LE

How to erect a fence FREE

Artificial Grass. Fitting Guide

CertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS. Fence Installation Guide 3', 4' & 6' High

Asset Protection Cathodic Protection Soil Resistivity Measurement. Work Instruction No.:

TOOLS NEEDED FOR PREGRA ARTIFICIAL GRASS INSTALLATION

V-Groover SIMPLEX INSTRUCTION AND OPERATION MANUAL M O DEL 703. For best results use only authentic Logan blades.

Desktop Trebuchet Kit Assembly Instructions

Yara Water Solution. Installation Guide. Product summary: - Included components - Tools for setup - Installation overview

INSTRUCTION MANUAL INF Fax: (503)

MERRY GO ROUND ITEM NO: 8030

IDAHO ASSEMBLY INSTRUCTIONS. BASE SIZE: 1.800m x 1.200m

ENVYPET 1(800) How to Install Your Turf 2013 Edition

SIMPLEX ELITE MAT CUTTER

Constructing Wire Fences

FUNCTIONAL DESCRIPTION

By Laurie Pessetto. Create your pattern. The decorative fabric will be on the edges of the circle layers.

M-66. Operating Manual FISHER RESEARCH LABORATORY. Valve and Box Locator (Metal Detector)

7 x 14 flybed tramp. VISIT LINK BELOW FOR INSTALL VIDEO

00108/00110 INSTRUCTION MANUAL

Side "A" Stake here. Side "C" Side "D" Side "B" Here Shirley and I are setting up a 10 X 16 ground work.

1.0. Aluminum Prebuilt Fence. Owner's Manual. Version. For Home, Haven, Select & Premier Series. Installation Instructions

Fabric Replacement Top and Doors

FOLDING MACHINE PF-45A OPERATOR MANUAL 1. FUNCTION

M-66. Valve and Box Locator (Metal Detector) Operating Manual

STAFF User Manual. Manual Part #

Laying and maintenance of cement tiles

EmagiKit. Privacy Pod Plus. Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY

A Deluxe LED Blinky That You Can Build!

Gardman Lean-to Greenhouse Assembly Instructions

RHINO II Bottom Drain Installation Instructions

Greenhouse Assembly Instructions

PRO-RIB FENCE PANELS INSTALLATION GUIDELINES. Virtually Maintenance Free Available in 24 Colors Custom Heights Available by the Inch

Storefront Installation Guide

LED Neon Light Round

OWNER'S MANUAL. Please Do Not Return This Product To The Store!

Installation Manual. Architectural Essentials Accessories

14 x 14 super quad. VISIT LINK BELOW FOR INSTALL VIDEO

Step by Step Wing Bagging

SuperTrack Parts List

Harmony Remote Repair

Please Do Not Return This Product To The Store!

TP3100(EA) Series TP3123(EA) / TP3126(EA) / TP3129(EA) / TP3132(EA)

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set #

Holz-Her Sliding Table Saw Kit Installation Instructions: For 1243 Cross-Cut Kits 2 DRO Retrofit

Project: Client: Part #: NEON -P FLT HB 24VDC WHT lc con cab. Date: Qty:

year5 Luxaflex Guarantee Guarantee, Installation and Operating Instructions Luxaflex Duette & Plissé Blinds Freehanging Models

Transcription:

Aquaflex Universal Soil Moisture Sensor (Model SI.162-mA) -User Manual- ma Version - The AQUAFLEX Universal Sensor (part # SI.162) uses the unique AQUAFLEX measurement technique using a 3m (10 ) long flexible tape to measure a volume of 6 litres (370 cubic inches) of soil. The Aquaflex Universal Sensor (ma Version) has two separate 4 to 20mA outputs of soil moisture (in volumetric percent), and soil temperature. These outputs facilitate easy connection to irrigation controllers, telemetry systems etc These signals may be used separately or simultaneously at any time without any changes to the sensor Sensor Installation Recommendations for sensor installation are given below. Your local AQUAFLEX Distributor will be pleased to give advice about the most suitable method of installation for your application. It is important that the sensor serial number and the location of the sensor are recorded: Serial Number Date Installed Location There are two main methods for installing the sensors, the choice of which to use depends on the required installation depth for the sensor. For shallow installation (eg turf applications) the sensor can be simply slit into the turf. For deeper installations a trench must be dug for the sensor. Installation Hints Always unroll the data cable. Pulling cables off the side of a roll results in the cable coiling, which makes it difficult to install in the trench. Install the data cable in a metal or plastic conduit if there is risk of damage from spiking etc. NOTE: The flat sensor cable must not be similarly protected. Ensure that the sensor cable is at least 150mm away from any foreign objects. Make sure you install in a place that will give readings that are representative for the whole irrigation area. If you have any questions please call Nicole Scannell on 021 811 411 or the office (see footer below). A q u a f lex N Z a d i v i s i on o f S t r ea t In s t ru m en t s L i m ited, 4 a E xp o P l a c e, P O B o x 2 4 0 71, C h r is tc h u rc h, Ne w Z e a l a n d Phone +64 3 384 8900 Fax +64 3 384 8901 info@aquaflex.co.nz www.aquaflex.co.nz

Shallow Installations (e.g. Turf) 1. Select and mark the position of the sensor with a string line. Position the sensor where it can be easily located in future e.g. on a marker line on a sports field or in a position on a golf green marked by sight markers (e.g. between two known points). 2. Note: If the soil is sandy, it is easier to install the sensor when the soil is wet, because it holds together better. 3. With a turf cutter or sharp, flat blade, carefully cut a slit in the turf. 4. Carefully insert the sensor into the slit to the desired depth. Note: The sensor must be installed on its edge. 5. For the electronics block at the end of the sensor, carefully peel back sufficient turf to create a slightly larger and deeper cavity in which to bury the block. Fold the turf back. 6. Gently push from behind each side of the slit to close it. Pack from the sides to recreate original density and remove air pockets. 7. Repair and smooth as necessary. 8. Apply a liberal amount of irrigation/water to allow the sensor to bed in and remove air pockets. 9. Run the data cable in a slit or trench to the desired location (e.g. an Adcon Telemetry add IT 720 Wireless Sensor Interface). Note: ensure that the cable is buried deep enough to avoid damage during maintenance. Run string line and cut a slit in turf Push sensor to desired depth Completed Installation AF-201-02 27 August 2014 2

Fenceline Deeper Installations (e.g. Agriculture or Vineyard) If you have any questions please call Nicole Scannell on 021 811 411 or the office. Make sure you install in a place that will give readings that are representative for the whole irrigation area. Please note that we now recommend that the Aquaflex data cable is installed 90 degrees from the fence line and the Aquaflex sensor runs parallel with the fence. (See Figure 1.0 below). Aquacom Unit attached to post Upper Aquaflex Sensor Aquaflex Data Cable (3 to 20m) Lower Aquaflex Sensor Figure 1.0 Aquaflex Installation Diagram Installing the data cable 1. Dig a data cable trench 400-500 mm deep from the base of the post out into the paddock. This trench may be 3 metres, 10 meters or 20 metres long depending on the length of data cable supplied with the Aquaflex. Remove the turf and place on one side of the trench and the soil on the opposite side. 2. Plug the sensor(s) into the telemetry unit and lay the data cable in the bottom of the trench and cover it with soil. Compact down with feet as you go so that the cable is flat and straight along the bottom of the trench. 3. Use the cable ties to keep the data cable against the post so that cows or other animals don t chew it. 4. Near the AQUAFLEX end leave the ditch open as it is easier to install the AQUAFLEX with flexibility in the data cable. Installing the Upper Aquaflex Sensor Refer to Figure 1 for the location of the trench for the Upper Sensor. When digging the data cable trench take note of how deep the topsoil is and where the majority of the roots are. The top sensor should only be installed within the majority of the root zone and within the topsoil as a general rule we install the sensor to 300 mm at the deepest. This removes the effect that a sub soil with different water holding capacity can have on the moisture measurement as the Aquaflex takes an average over the whole sensor. 1. Lay a plastic sheet or similar alongside the area where the trench is being dug. Dig out the turf and lay on the opposite side from the plastic sheet. If soil is falling from the turf then it would be advisable to lay the turf onto the plastic sheet. AF-201-02 27 August 2014 3

2. Start at the shallow (box end). Dig down to 50mm. The box contains the thermometer so needs to sit at 100 mm depth to give a standard temperature reading. 3. Remembering to remove and place the soil in its natural layers/horizons on the plastic sheet, dig a sloping trench down to the bottom of the topsoil across the 3 metre length of the Aquaflex Sensor. Nominated depth 4. Once the trench has been dug make sure that the bottom of the ditch is on an even slope. 5. Lay the Aquaflex Sensor down in the middle of the trench. One person holding the box end and the other laying the Aquaflex Sensor down to the far end. The Aquaflex Sensor is installed on the edge (so that water cannot sit on the top of the sensor). 6. Make sure you apply the right layer of soil and stones in the appropriate place. Move the soil around before packing it down to ensure any air gaps have been filled in by loose aggregates. 7. Pack tightly with either your feet or post hole rammer depending on the surrounding soil profile you want the soil to return to its original density as best as possible. Make sure that you don t ram or stand on the Aquaflex as it may bend over or damage it. 8. Stones are to be replaced in the trench as best as possible, directly beside or on the sensor is not advised due to air gaps and possible sensor damage, place the stones in the trench where they will not cause damage to the sensor with compaction. 9. Insert a paver at each end of the Aquaflex sensor (put 200 mm further out than the real end) Also Streat Instruments insert a sticker diagram of where the sensor is on the inside the radio telemetry box so that the farmer can easily identify where the sensor is. Installing the lower sensor (If one has been purchased) Refer to Figure 1 for the location of the trench for the Lower Sensor (in the opposite direction to where the Upper Sensor is installed from the end of the data cable trench). 1. Lay a plastic sheet or similar alongside the area where the trench is being dug. Dig out the turf and lay on the opposite side from the plastic sheet. If soil is falling from the turf then it would be advisable to lay the turf onto the plastic sheet. 2. Dig the trench to a depth which is below the root zone, this is most often 500mm in a grass pasture. Again the soil needs to be removed in its layers and placed onto a plastic sheet. Ensure you remove the soil in layers, at least three soil layers would be advisable. 3. The lower sensor usually gets installed horizontally at one depth (i.e not on a slope), lay the bottom sensor on its edge at the bottom of the trench and place the correct AF-201-02 27 August 2014 4

layer of soil /stones around it. Place the soil, around the sensor to and move the soil around to ensure any large air gaps are filled in by loose soil. 4. Make sure you apply the right layer of soil and stones in the appropriate place. Stones are to be replaced in the trench as best as possible, directly beside or on the sensor is not advised due to air gaps and possible sensor damage, place the stones in the trench where they will not cause damage to the sensor with compaction. This is most important if you want you Aquaflex Sensor to work properly and accurately as soon as possible. 5. Fill in the trench slowly making sure the soil from each level is replaced as it was removed. Pack tightly with either your feet or post hole rammer depending on the surrounding soil profile you want the soil to return to its original density as best as possible. Make sure that you don t ram or stand on the Aquaflex as it may bend over or damage it. 6. Once the Aquaflex trench has been filled, complete filling the cable trench and replace the turf. 7. Replace the turf and ram or roll the top of all the trenches with the digger tracks as long as no risk of over-compaction is present. 8. Advise the land owner of the maintenance that is necessary to gain accurate data, it is easiest to give them a copy of the maintenance guidelines which include heavy rolling, installing an outrigger etc etc. Helpful Pictures Soil removed and placed in three layers. Top sensor being installed to 25mm at the deep end. AF-201-02 27 August 2014 5

Documentation 1. AQUAFLEX Records Sensor 1 S/no.: Sensor 1 Depth: 50 to mm Sensor Cable Length: m Top sensor installed to (depth): mm Topsoil depth: mm Topsoil Type: Topsoil Stone size: mm Topsoil Stone %: Subsoil Type: Subsoil Stone size: mm Subsoil Stone %: Sensor 2 S/no.: Sensor 2 Depth: mm Upper Sensor to mm Data Cable m Lower Sensor 500 mm Please draw an Arrow to show North on the diagram. Note the upper and lower can be installed in either direction. AF-201-02 27 August 2014 6

Converting the Signal to Soil Moisture or Temperature 4-20mA Outputs For Moisture: Moisture (%) = 3.75 x C - 15 For temperature : Temp ( C) = 3.75 x C 25 Where C is the output current in ma. When a 125 Resistor is Used to Convert the 4-20mA Signal to a 0.5 to 2.5 volt Signal For Moisture: Moisture (%) = 30 x V - 15 For temperature: Temp ( C) = 30 x V - 25 Where V is the output voltage. Electrical Connections Wire Colour Red Black Violet Description Sensor power +ve, 6.0 to 26 Volts. Sensor ground, 0 Volts Not Used White Moisture output, ma + Blue Moisture output, ma - Brown Temperature output, ma + Orange Temperature output, ma - Moisture output, 4-20 ma. Temperature output, 4-20mA. Yellow Factory only, do not connect. Note: The Sensor Ground and ma - cores are connected internally within the sensor, therefore this sensor is not suitable for situations that require fully isolated outputs. Sensor Fault Indicators If a fault occurs, the sensor outputs special signals, as follows: Signal (V across 125 load ) Fault condition 0mA 0 V 0 ppm A broken wire or possible failure in the sensor. Check the wiring and repair. Contact your distributor if wires are intact. 1 ma 0.125 V 2.5 ppm Moisture reading out of expected range. If this output continues, contact your distributor. (Note: sensors will often give this output when in air, before burial this is normal) 2 ma 0.250 V 5.0 ppm Low battery or supply voltage. Replace the batteries or check power supply. 3 ma 0.375 V 7.5 ppm Critical sensor settings have been lost. Contact your distributor. AF-201-02 27 August 2014 7

Specifications Power supply voltage Power supply current 4-20mA outputs +6.0 to +26 Volts, DC. 10mA average, 150mA peak (for 60 milliseconds during measurement) plus two current loops of up to 20mA each. Moisture Output 4-20mA representing the moisture range 0-60%. Temperature Output 4-20mA representing the temperature range -10 to 50 C. Maximum load resistance 250 with 9 Volts supply. 1 k with 24 Volts supply. The 4-20mA signals may be converted to voltage signals by connecting external resistors across the 4-20mA outputs. Using a 125 resistor results in a 0.5 to 2.5V range. Time to measure Time between measurements Operating Temperature Soil Moisture Measurement Range Precision / Repeatability Accuracy Soil Temperature Measurement Range Accuracy 1.5 seconds after power supplied (typical). 2 second maximum. 1 minute, if power applied constantly. -10 to 40 C (14 to 104 F) 0 to 60% volumetric moisture content ± 0.5% volumetric moisture content ± 2% volumetric moisture content The temperature is measured at the body of the sensor, not along the moisture-sensing cable. -10 to 50 C (14 to 122 F) ± 0.5 C (0.9 F) Conditions of Use Aquaflex must be installed as specified. Use of Aquaflex data is entirely at the discretion of the user and should therefore be subject to current best practice principles of soil moisture management and agronomic management. Neither Streat Instruments nor its Distributors shall be liable (whether in contract, tort or otherwise) for any loss (including but not limited to loss of profits and consequential loss) of any kind whatever arising out of any published material or in connection with the performance or use of Aquaflex. The serial number marked on each Aquaflex Sensor must be recorded and quoted for warranty claims. Streat Instruments 4A Expo Place PO Box 24071 Christchurch New Zealand Ph: +64 3 384 8900 Fax: +64 3 384 8901 mail@streatsahead.com www.streatsahead.com UK Office Garnett Group Unit 6 Great Russell Court Fieldhead Business Centre Bradford BD7 1JZ United Kingdom Ph: +44 1274 733 145 Fax: +44 1274 736358 mail@streatsahead.com www.streatsahead.com AF-201-02 27 August 2014 8