Matrix Power Company MH xxx-va series Specification Document

Similar documents
Product Specification

TC-2U70PD8. Switching Power Supply ( 2U 700W 80PLUS) SPECIFICATION. Revision: 2.0

TC-600PD2. Switching Power Supply ( 600W PS2 ATX12V ) SPECIFICATION. Revision: 1.0

SPECIFICATION SilverStone ST30NF for Standard Switching Power Supply With Active PFC PS/2 Fanless 300W

SPECIFICATION. SilverStone OLYMPIA OP1000 Switching Power Supply Active PFC

SFX Form Factor SST-SX650-G SST-SX500-G. The standard SFX power supply benchmark

ST-250MAK-05E. Switching Power Supply SPECIFICATION

TC-750PD8. Switching Power Supply ( PS2 ATX750W 8 0 PLU S ) SPECIFICATION. Revision: 1.0

SPECIFICATION ESD FSP600-80PSA(SK) Released Date:2017/02/08-10:47:01

AC/DC Power Supply Series APPLICATION NOTE

SPECIFICATION. SilverStone Zeus ST75ZF. Switching Power Supply. With Active PFC PS/2 750W

SPECIFICATION ARP

SPECIFICATION ESD Released Date:2012/12/20-10:56:04

NIGHTJAR SERIES SST-ST45NF. Optimum fan-less power supply with stability and silence

AC/DC Power Supply Series APPLICATION NOTE

SPECIFICATION ESD Released Date:2012/09/28-18:39:41

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

AC/DC Power Supply Series APPLICATION NOTE

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

PDAM500 Series 500W Power Supply

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

SSD3000 MODULE 280 WATT 12V FRONT END 8.66 x 1.99 x x 50.5 x 40mm

OP650 -P. Single rail stepping up to a higher gear OP SERIES

REDUNDANT DC 200W POWER SUPPLY. Technical Specifications TD-DC-200W-12V

DA850. The all around power DECATHLON

REDUNDANT AC 300W POWER SUPPLY. Technical Specifications TD-AC-300W-MAX

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

MINI-ITX Power Supply

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE BPS-460RDX 6-OUTPUT 460W+460W BEST POWER SOLUTIONS, INC.

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

ENHANCE SWITCHING POWER SUPPLY SPECIFICATION 250 WATT MODEL NO:V525

SPECIFICATION ESD FSP300-60GHT,(85)F. Released Date:2016/05/18-15:38:12

STRIDER ESSENTIAL SERIES SST-ST50F-ES230 Power for everything you need

Switching Power Supply SPECIFICATION

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

IP67 DESCRIPTION KEY FEATURES MARKET SEGMENT AND APPLICATIONS TRC ELECTRONICS, INC

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

AED500H22S Power Supply Product Specification. An APM Electronics USA, Inc. Power Supply Specification For ERP1U Power Supply

SPECIFICATION. SilverStone. 300W SFX Switching Power Supply FSP300-60GHS Meet 80 Plus Active PFC Circuit Full Range Input Small Size

Output Voltage Output Amps Input Range Max. Iin FL Efficiency (Tb=25 C) O/P Set Point

AC/DC Power Supply Series APPLICATION NOTE

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

200 WATT TH SERIES DC/DC CONVERTERS

AC/DC Power Supply Series APPLICATION NOTE

LB115S 115W Single Output

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

Line Reg Load Reg Ripple Efficiency *Model Number Output V Output I (nom/max) (nom/max) & Noise (min/nom)

AEA300R22S / AEA400R22S-1 Power Supply Product Specification

TB65 65W Single Output Test and Measurement/Industrial Series

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

QUARTER-BRICK SERIES Single Output Performance Products

Rev. Page Item Date Description A2 4. MAR Update output rating & input voltage

18093-PS PHIHONG TECHNOLOGY CO., LTD. General Specification PSM (DC)

QUARTER-BRICK SERIES Single Output Value Products

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

INPUT VOLTAGE STARTING MINIMUM NORMAL MAXIMUM MAXIMUM INPUT RANGE VOLTAFE VOLTAGE VOLTAGE VOLTAGE CURRENT

DDP400 SERIES KEY FEATURES DESCRIPTION MARKET SEGMENTS AND APPLICATIONS

SFD550-12BG Front-End Preliminary Data Sheet DC Input, 12V Output, 550 Watts

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

SPECIFICATION ESD FSP460-60HCN. Released Date:2011/04/01-15:26:46

Doc. EA Model Number:

SPECIFICATION ESD FSP500-60GHC. Released Date:2012/12/26-15:25:33

MB120S 120W Single Output Medical Series

OVP 2:1. Wide Range. Protection

Efficiency (typ.) (Range) Load. Output Current Input Current Reflected Ripple

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

SXN15 48V SERIES. Dual output TÜV. High Efficiency DC/DC Converters

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

Power Supplies 3. SDN-C Compact DIN Rail Series

DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

IS -500RSH1UP. Redundant Power Supply ( 1U- 500W ) SPECIFICATION. Revision: 1.0

Model and Output Power Output Nominal Voltage Package Option Means of Protection Grade. 12 V DC: -US12 Open Frame: -OF. 24 V DC: -US24 U-Chassis: -UC

Power Supply Unit (550W)

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

DDP400 and MDP400, SC series, are sealed, full potted, compact, high efficiency, small form factor AC-DC power supplies.

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Watts HCP Series

Technical Reference Notes AIT00ZPFC-01NL. AIT00ZPFC 150W AC-DC Converter Module

Single negative output

SPECIFICATION ESD FSP250-60HNC. Released Date:2012/08/15-21:58:49

Electrical Specifications. > 0.9 beginning at 20% load. ITHD 10% Leakage current. Ordering Information

48V Output AC/DC Converter Box Type Package

PM24S/DR24S series 60W Single Output DC/DC Converter

(typ.) (Range) Parameter Model Min. Typ. Max. Unit

(DOSA) VDC, 5.5 A.

Medical / Industrial AC-DC Power Supply 1200W with 5V/2A Standby / MEB-1K2A series

AIH - 300Vin, 250W, DC-DC Converter Module

Product Specification sheet

Electrical Specifications

DA45C USB-PD. Product Descriptions. 45 Watts

X Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters

Cool Power Technologies

POWER DS500SDC. 500 Watts Distributed Power System. Data Sheet

TE60 60W Single Output External Power Test & Measurement/Industrial Series

Transcription:

Matrix Power Company MH xxx-va series Specification Document

TABLE OF CONTENTS 1. Scope 2. Applicable document: 3. Electric specification: 3.1 AC input requirement: 3.1.1 AC input requirement 3.1.2 Over current protection 3.1.3 Inrush current limiting 3.1.4 Input under voltage 3.1.5 Electrical fast transient/burst 3.2 DC output requirements: 3.2.1 DC voltage regulation 3.2.2 remote sense 3.3 Power description: 3.3.1 Output requirement 3.3.2 Efficiency 3.3.3 Output ripple and noise 3.3.4 Output transient response 3.3.5 +5Vdc and +3.3Vdc power sequencing 3.3.6 voltage hold-up time 3.4 Timing / housekeeping / control 3.4.1 Power_OK 3.4.2 Power_ON 3.4.3 +5Vsb 3.4.4 Power ON time 3.4.5 Rise time 3.4.6 Overshoot at turn_on/turn_off 3.4.7 Reset after shutdown 3.4.8 +5vsb at power down 2

3.5 Output protection: 3.5.1 Over voltage protection 3.5.2 Short circuit protection 3.5.3 No load operation 3.5.4 Over current protection 3.5.5 Over load protection 3.5.6 Output bypass 4. Mechanical requirement: 4.1 Label and marking 4.2 Physical dimension 4.3 Air flow / fan 4.4 Connector 5. Environment requirement 5.1 Environment requirement 5.2 Thermal shook (shipping) 5.3 Humidity 5.4 Altitude 5.5 Mechanical shock 5.6 Vibration 6. Electromagnetic compatibility 7. Reliability 7.1 Mean time between failure (MTBF) 7.2 Compatibility 7.3 Safety requirement 3

1. SCOPE: This document outlines the power supply specification of MH-series. 2. Applicable Documents: See ATX Specification Version 2.03/_12V version 1.3,BTX 1.0/ 1.1/ 2.0 and Intel ATX Power Supply Design Guide Version 0.9. 3. Electric specification: The electrical requirements that follow are to be met over the environmental ranges specified in Section 5 unless otherwise noted. 3.1 AC input requirement: 3.1.1 AC input requirement: a. The power supply shall be capable of supplying full rated output power over two input voltages ranges rated 115 VAC and 230 VAC RMS nominal at 0 ~ 50. b. Input voltage range Input frequency range Selecting 85Vac ~ 135Vac 47Hz ~ 63Hz Select switch 170Vac ~ 265Vac 47Hz ~ 63Hz Select switch c. Auto range: **optional d. PFC function **optional *For Active PFC Vin=100-240Vac full-range, PF=0.95min. *For Passive PFC Vin=115/230Vac by-switch, PF=0.85 typ. 3.1.2 AC over current Protection: The power supply shall incorporate primary fusing for input overcurrent protection. Fuses should be slow-blow type or equivalent to prevent nuisance trips. 3.1.3 Inrush Current Limiting: Maximum inrush current from power-on (with power on at any point on the AC Sine) and including, but not limited to, three line cycles, shall be limited to a level below the surge rating of the input line cord, AC switch if present, bridge rectifier, fuse, and EMI filter components. Repetitive ON/OFF cycling of the AC input voltage should not damage the power supply or cause the input fuse to blow. 3.1.4 Input under voltage: The power supply shall contain protection circuitry such that the application of an input voltage below the minimum specified in Section 3.1, Table 1, shall not cause damage to the power supply. 4

3.1.5Electrical fast transient/burst: No unsafe operation is allowed under any condition. No user-noticeable performance degradation up to +- 1 kv Mains, +- 500V Signal Cable, is allowed. Automatic or manual recovery is allowed for other conditions. 3.2 DC Output Requirements 3.2.1 DC Voltage Regulation The DC output voltages shall remain within the regulation ranges shown in Table 3 when measured at the load end of the output connectors under all line, load, and environmental conditions. The voltage regulation limits shall be maintained under continuous operation for a period of time equal to or greater than the MTBF specified in Section 7.2 at any steady state temperature and operating conditions specified in Section 5. Table 3: DC Output Voltage Regulation Output Range Min. Nom. Max. Unit +12Vdc ±5% +11.40 +12.00 +12.60 Volts +5Vdc +5-4% +4.80 +5.00 +5.25 Volts +3.3Vdc +5-4% +3.17 +3.30 +3.46 Volts -5Vdc ±5% -4.75-5.00-5.25 Volts -12Vdc ±10% -11.40-12.00-13.20 Volts +5Vsb ±5% +4.75 +5.00 +5.25 Volts 3.2.2Remote Sensing a. For the +12V, +5 V and +3.3 V, the power supply shall use remote sensing wires to achieve regulation at the output connector to compensate for voltage drop of cable, connector, and PCB trace. If the remote connection is lost to any of these outputs, then internal resistive feedback causes the power supply to regulate and prevent OVP. b. The power supply should have remote sense return (Returns) to regulate out ground drops for all output voltages, +12V, +3.3V, and +5V. The power supply will uses remote sense (+3.3Vs, +5Vs, +12Vs) to regulate out drops in the system for the +3.3V, and +5V outputs. Remote sense must be able to regulate out a minimum of 250mV of drop on the +3.3V and +5V outputs. The remote sense return (Returns) must be able to regulate out a minimum of 100mV of drop in the power ground return. The current in any remote sense line shall be less than 10mA to prevent voltage sensing errors. The power supply must operate within specification over the full range of voltage drops from the power supply's output connector to the remote sense points. 3.3 Power Description: 5

3.3.1 Output requirement: Table 4.1: MH350-VA Power Distribution Configuration Outputs MIN MAX Watt Peak 3.3V 0.0A 28.0A 92.4 40.0A 5.0V 1.0A 35.0A 150.0 40.0A -5.0V 0.0A 0.5A 2.5 1.0A 12.0V 0.0A 28.0A 336.0 28.0A -12.0V 0.0A 0.8A 9.6 1.5A 5.0Vsb 0.0A 2.00A 10.0 3.0A Total = 350 Watt Maximum combined wattage of 3.3V and 5.0V outputs is 175W. Table 4.2: MH400-VA Power Distribution Configuration Outputs MIN MAX Watt Peak 3.3V 0.0A 28.0A 92.4 40.0A 5.0V 1.0A 40.0A 200.0 60.0A -5.0V 0.0A 0.5A 2.5 1.0A 12.0V 0.0A 30.0A 360.0 32.0A -12.0V 0.0A 0.8A 9.6 1.5A 5.0Vsb 0.0A 2.00A 10.0 3.0A Total = 400 Watt Maximum combined wattage of 3.3V and 5.0V outputs is 200W. Table 4.3: MH450-VA Power Distribution Configuration Outputs MIN MAX Watt Peak 3.3V 0.0A 28.0A 92.4 40.0A 5.0V 1.0A 45.0A 225.0 60.0A -5.0V 0.0A 0.5A 2.5 1.0A 12.0V 0.0A 35.0A 420.0 37.0A -12.0V 0.0A 0.8A 9.6 1.5A 5.0Vsb 0.0A 2.00A 10.0 3.0A Total = 450 Watt Maximum combined wattage of 3.3V and 5.0V outputs is 225W. Table 4.6: MH500-VA Power Distribution Configuration 6

Outputs MIN MAX Watt Peak 3.3V 0.0A 28.0A 92.4 40.0A 5.0V 1.0A 50.0A 250.0 60.0A -5.0V 0.0A 0.5A 2.5 1.0A 12.0V 0.0A 35.0A 420.0 40.0A -12.0V 0.0A 0.8A 9.6 2.0A 5.0Vsb 0.0A 2.00A 10.0 3.0A Total = 500 Watt Maximum combined wattage of 3.3V and 5.0V outputs is 250W. Table 4.7: MH600-VA Power Distribution Configuration Outputs MIN MAX Watt Peak 3.3V 0.0A 28.0A 92.4 40.0A 5.0V 1.0A 50.0A 250.0 60.0A -5.0V 0.0A 0.5A 2.5 1.0A 12.0V 0.0A 35.0A 420.0 48.0A -12.0V 0.0A 0.8A 9.6 2.0A 5.0Vsb 0.0A 2.00A 10.0 3.0A Total = 600 Watt Maximum combined wattage of 3.3V and 5.0V outputs is 300W. 3.3.2Efficiency a. The efficiency of the power supply should be met over the AC input range defined in Table 1, under the load conditions defined in Section 3.3, and under the temperature and operating conditions defined in Section 5. The power supply should be a typical of 72% efficient under full load as defined in the applicable configuration. b. The +5Vsb standby supply efficiency should be 65% at 2.0A output. Standby efficiency is measured with the main outputs off and with PWR_ON high. The AC input power shall not exceed 8 W when the main outputs are in the "DC disabled" state with 1.0 A load on +5VSB and the input is 230 VAC/50 Hz or 115VAC/60Hz. 3.3.3 Output Ripple/Noise a. The following output ripple/noise requirements should be met throughout the load ranges specified in Section 3.3, and under all input voltage conditions as specified in Section 3.1. b. Ripple and noise are defined as periodic or random signals over a frequency band of 10 Hz to 20 MHz. Measurements shall be made with an oscilloscope with 20 MHz bandwidth. Outputs should be bypassed at the connector with a 0.1 uf ceramic disk capacitor and a 47 uf electrolytic capacitor to simulate system loading. Table 5: DC Output Noise/Ripple 7

Output Max Ripple & Noise (mvpp) +12VDC 120 +5VDC 50 +3.3VDC 40-5VDC 50-12VDC 120 +5VSB 50 3.3.4 Output Transient Response The +3.3VDC, +5VDC and +12V outputs will see transients up to 50% of the maximum output current. \ The transient slew rate will be 2.5 A/ms. The power supply should be stable under all transient conditions from any steady state load, and the over/undershoot should be within the regulation band stated in Section 3.2.1. 3.3.5 +5VDC/+3.3VDC Power Sequencing The +5VDC output level must be equal to or greater than the +3.3VDC output at all times during power-up and normal operation. The time between the +5VDC output reaching its minimum in-regulation level and +3.3VDC reaching its minimum in-regulation level must be less than or equal to 20 msec. 3.3.6 Voltage Hold-up Time The power supply shall maintain output regulation per Section 3.2.1 despite a loss of input power at the nominal range (Low = 115 VAC, 60 Hz or 230 VAC, 50 Hz) at maximum continuous output load as applicable for a typical of 17 ms. 3.4 Timing / Housekeeping / Control Figure 1: Power Supply Timing Notes: a. T2 is defined in Section 3.4.5 b. T3, T4, and T5 are defined in Table 7 3.4.1 PWR_OK 8

PWR_OK is a "power good" signal. It is asserted high by the power supply to indicate that the +5VDC and +3.3VDC outputs are above the undervoltage thresholds listed in Section 3.2.1 and that sufficient mains energy is stored by the converter to guarantee continuous power operation within specification for at least the duration specified in Section 3.3.6. Conversely, PWR_OK should be deasserted to a low state when either the +5VDC or the +3.3VDC output voltages falls below the undervoltage threshold, or when mains power has been removed for a time sufficiently long such that power supply operation cannot be guaranteed beyond the hold-up time. The electrical and timing characteristics of the PWR_OK signal are given in Table 7 and in Figure 1. Table 7: PWR_OK Signal Characteristics Signal Type Logic level Low Logic level high High state output impedance PWR_OK delay PWR_OK rise time Power down warning +5 V TTL compatible < 0.4 V while sinking 4mA Between 2.4 VDC and 5 VDC Output while sourcing 200uA 1KΩ from output to common 100 ms < T3 < 500 ms T5 10 ms T4 > 1 ms 3.4.2 PWR_ON a. PWR_ON is an active-low, TTL-compatible signal that allows a motherboard to remotely control the power supply in conjunction with features such as soft on/off, wake-on-lan, or wake-on-modem. When PWR_ON is pulled to TTL low, the power supply should turn on the five main DC output rails: +12VDC, +5VDC, +3.3VDC, -5VDC, and -12VDC. When PWR_ON is pulled to TTL high or open circuited, the DC output rails should not deliver current and should be held at zero potential with respect to ground. PWR_ON has no effect on the +5VSB output, which is always enabled whenever the AC power is present. b. Power supply shall provide an internal pull-up to TTL high. The power supply shall also provide debounce circuitry on PWR_ON to prevent it from oscillating on/off at startup due to activation by a mechanical switch. The DC output enable circuitry must be SELV-compliant. 3.4.3 +5VSB +5VSB is a "standby" supply output that is active whenever the AC power is present. It provides a power source for circuits that must remain operational when the five main DC output rails are in a disabled state. Example uses include soft power control, wakeonlan, wake-on-modem, intrusion detection, or suspend state activities. +5VSB is required for the implementation of PWR_ON. The +5VSB output should be capable of delivering 2.0A at +5 V ±5% to external circuits. 3.4.4 Power-on Time 9

The power-on time is defined as the time from when PWR_ON is pulled low to when the +5VDC and +3.3VDC outputs are within the regulation ranges specified in Section 3.2.1. The power-on time shall be less than 500ms. +5VSB shall have a power-on time of 2 seconds maximum after application of valid DC voltages. 3.4.5 Risetime The output voltages shall rise from <10% of nominal to within the regulation ranges specified in Section 3.2.1 within 0.1 ms to 20 ms (0.1 ms < T2 20 ms) 3.4.6 Overshoot at Turn-on/Turn-off The output voltage overshoot upon the application or removal of the input voltage, or the assertion / deassertion of PWR_ON, under the conditions specified in Section 3.1, less than 10% above the nominal voltage. There is a smooth and continuous ramp of each DC output voltage from 10% to 90% of its final set point within the regulation band, while loaded as specified in Section 3.3. The smooth turn-on requires that during the 10% to 90% portion of the rise time, the slope of the turn-on waveform is positive and have a value of between 0 V/ms and [Vout, nominal] V / 0.1 ms. Also, for any 5 ms segment of the 10% to 90% rise-time waveform, a straight line drawn between the end points of the waveform segment must have a slope [Vout, nominal] V / 20 ms. No voltage of opposite polarity present on any output during turn-on or turn-off. 3.4.7 Reset After Shutdown If the power supply latches into a shutdown state due to fault condition on its outputs, the power supply shall return to normal operation only after the fault has been removed and the PWR_ON (or DC input) has been cycled OFF/ON with a minimum OFF time of 3 second. 3.4.8 +5VSB at AC Power Down After AC power is removed, the +5VSB standby voltage output should remain at its steady state value for the minimum holdup time specified in Section 3.3.6 until it begins to decrease in voltage. The decrease shall be monotonic in nature, dropping to 0.0 V. There shall be no other perturbations of this voltage at or following removal of AC power. 3.5 Output Protection 3.5.1 Over voltage Protection The over voltage sense circuitry and reference shall reside in packages that are separate and distinct from the regulator control circuitry and reference. No single point fault shall be able to cause a sustained overvoltage condition on any or all outputs. The supply shall provide latch-mode overvoltage protection as defined below. Table 9: Overvoltage Protection 10

Output Min. Nom. Max. Unit +12VDC 14.0 ----- 15.0 Volts +5VDC 5.8 ----- 6.9 Volts +3.3VDC 3.8 ----- 4.3 Volts 3.5.2 Short Circuit Protection An output short is defined as any output impedance of less than 0.1 ohms. The power supply shall shut down and latch off for shorting the +3.3VDC, +5VDC, +12VDC, -12V rails to return or any other rail. The power supply will shut down and latch off. The +5VSB must be capable of being shorted indefinitely, but when the short is removed, the power supply shall recover automatically. The power supply shall be capable of withstanding a continuous short-circuit to the output without damage or overstress to the unit (components, PCB traces, connectors, etc.) under the input conditions specified in Section 3.1. 3.5.3 No Load Operation The power supply shall be turn on, and no damage or hazardous condition should occur with all the DC output connectors disconnected from the load. 3.5.4 Over current Protection: **OPTIONAL If any one output of +5Vdc, +12Vdc and +3.3Vdc is over current then maximum load, the power supply is shut down by over current protection design, the output voltage shall drop to 0V at +5Vdc, +12Vdc, +3.3Vdc, +5Vsb, -5Vdc and 12Vdc output, and no any damage to the power supply. 3.5.5 Over load protection: The total power output is limit at 105~150%. 3.5.6 Output Bypass The output return is connected to the power supply chassis. The return will be connected to the system chassis by the system components. 4. Mechanical requirement: 4.1 Label and marking: The label must be follow safety ( UL, cul, TUV, CE ) request. 4.2 Physical dimensions 11

The supply shall be enclosed and meet the physical outline of 1U 1U: MH350~600-VA ; 40*100*250mm 4.3 Airflow / Fan Airflow will be provided by two fans in each power module and fans out the computer chassis. 4.4 Cable: following ATX specification. 5. Environment requirements: 5.1 Environment requirement: Operating ambient temperature: 0 ~ 50 The power supply be capable of supplying full rated output power over two input voltages ranges rated 115 VAC and 230 VAC RMS nominal at 25. Nonoperating ambient temperature: -40 ~ +70 (Maximum rate of change of 20 C/hr.) 5.2 Thermal shock (shipping): Nonoperating: -40 C to +70 C; 15 C/min < dt/dt < 30 C/min; 50 cycles; Duration of exposure to temperature extremes for each half cycle shall be 30 minutes. 5.3 Humidity: Operating: To 85% relative humidity (noncondensing) Nonoperating: To 95% relative humidity (noncondensing) Note: 95% RH is achieved with a dry bulb temperature of 55 C and a wet bulb temperature of 54 C. 5.4 Altitude: Operating: To 10,000 ft Nonoperating : To 50,000ft 5.5 Mechanical Shock Nonoperating : 50 g, trapezoidal input; velocity change > 170 in/s. Three drops on each of six faces are applied to each sample. Operational: The unit will be able to withstand 10g acceleration peak (11msec pulse duration). 5.6 Vibration 12

Nonoperating : 0.01 g2 / Hz at 5Hz, sloping to 0.02 g2/hz at 20Hz, and maintaining 0.02 g2 / Hz from 20 Hz to 500 Hz. The area under the PSD curve is 3.13 grms. The duration shall be 10 minutes per axis for all three axes on all samples. Also meet 5-17Hz, 0.1 double amplitude displacement; 17-500Hz, 1.5G acceleration; 5 to 500Hz random, 1G(RMS) acceleration. 6. Electromagnetic Compatibility Meet CE. Meet FCC. Meet CNS13438. 7. Reliability 7.1 Mean time between failure (MTBF): MTBF shall be follow 570F standard. a. Full load. b. 230Vac input. c. Ground benign. d. Ambient temperature: 25 The calculated MTBF of the power supply shall be greater than 100,000 hours under the following conditions: a. Full load. b. 230Vac input c. Ground benign d. 25 C ambient. 7.2 Compatibility All versions of the power supply will be backward compatible for form, fit, and function of the ATX/0.9/1.0/1.1/2.01/2.02/2.03/_12V/1.0/1.1/1.2/1.3, BTX/1.0/1.1/2.0 Version. 7.3 Safety Requirements The power supply must be meet UL, c-ul, TUV, CE, CB, FCC, CNS. 7.4 Web site: mapc.com.tw 13