Series 9000 Vinyl Fixed Window

Similar documents
Series 9000 Vinyl Fixed Window

Series 9000 Vinyl Single Hung

Series 6000 Vinyl Single Hung

Series 9000 Vinyl Horizontal Slider

Series 6000 Vinyl Horizontal Slider

Series 6000 Vinyl Fixed Window Contents

4300Wi WOOD INTERIOR CASEMENT VINYL WINDOW gerkin.com

Architectural Manual. Vinyl Windows & Patio Doors

SECTION BULLET- RESISTANT DOORS

A. ASTM D Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.

Style Line Series. Vinyl Windows. Architectural Manual

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Air Infiltration The amount of air leaking in and out of a building through cracks in walls, windows, and doors.

Dear Contractor, I am glad that you are interested in our window rebate program.

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

Tools required by installer: Materials required by installer:

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

Vinyl Windows Manufactured by VPI Quality Windows

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

INSTALLATION GUIDELINES: X25 SERIES using perimeter installation fin

PROJECT LOCATION SECTION PREFINISHED STEEL DOOR FRAMES

Vinyl Windows and Doors Manufactured by VPI Quality Windows

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Cable Bay Windows. Tuscany Vinyl Replacement Window. - Min Max SINGLE-HUNG

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS

Architectural Manual. Premium Vinyl Windows & Patio Doors

DF COLLECTION. Architectural Detail Guide Double-Hung Window DF 3604 TABLE OF CONTENTS

Bovard Studios Inc. Section April 6, 2004 Page 1

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

Architectural detail manual Double-Hung window DF3604

Architectural Manual. Premium Vinyl Windows & Patio Doors

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

VYTEC ARCHITECTURAL SPECIFICATIONS

AA TM 3900 THERMAL SLIDING DOOR

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

Architectural Manual. Premium Vinyl Windows & Patio Doors

SECTION HOLLOW METAL DOORS AND FRAMES

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

AAMA Voluntary Guideline For Engineering Analysis of Window and Sliding Glass Door Anchorage Systems

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

Definitions and Design Considerations... W-CR-2

Doors & Windows. Series 700 Windows, Single Hung Tilt Standard Features. Slider Lock. Vinyl Windows. J-Rail '

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

Storefront Installation Guide

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

GUIDELINE SPECIFICATIONS

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

SECTION INTERIOR SIGNAGE

Steel Reinforced Joining Guide (Horizontal / Vertical)

THERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE)

Awning and Casement Window

about us PLYGEM

Product Guide Specification For Nonrated & 20-Minute Rated Doors

PRODUCT DESCRIPTION. This evaluation report includes aluminum clad wood skylights based on the following tested configurations:

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS

Sun Windows General Information New Construction Hinged Door Installation Instructions

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

SERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS

DETAILED STILE AND RAIL WOOD DOOR SPECIFICATION

TESTED FOR Report No. : A04H-009 Date : February 10, 2004 FLEETWOOD ALUMINUM PRODUCTS, INC. Page : 1 of Railroad Street Corona, CA 91720

Non-Reinforced Joining Guide (Horizontal/Vertical)

WOOD OUT SWING AWNING, CASEMENT, & HOPPER WINDOW

Installation Recommendations for Finless Frame Doors

GENERAL INSTALLATION GUIDELINES

SECTION B INDEX STOREFRONT FRAMING SYSTEMS

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

Window Frame Installation Instructions For Nail-on and Block Frames

GENERAL INSTALLATION GUIDELINES

NEW CONSTRUCTION, REPLACEMENT AND FLUSH FIN REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS

A. All trim that has been damages, broken, or missing shall be repaired or replaced with material of the same size, shape, and type.

All Window Installation Instruction

Architectural Manual. Premium Vinyl Windows & Patio Doors

(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS

14000 Series. Fabrication and Installation Instructions

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

DHS-500 IMPACT SYSTEM INSTALLATION MANUAL

SECTION FRAMELESS GLASS SLIDING BI-FOLD SHOWER DOOR HARDWARE

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION

14000 Series. Fabrication and Installation Instructions

SECTION MANUFACTURED CASEWORK

Masonite Steel Entry Doors

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023)

4500 Series. Fabrication and Installation Instructions

Architectural Testing AAMA 501 TEST REPORT. Report Number: C Rendered to: Tubelite, Inc. Walker, Michigan

MANUFACTURING INC. Specifications

INTEX Millwork Solutions SECTION EXTERIOR PVC PERGOLAS (IBC Compliant)

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

General Information... Elevation Notes... Elevation Notes Transom... Light Cut Information... Clear Opening Design Data Table 1 & 2 Panel...

SECTION WOOD DOORS

ARCHITECTURAL STICK SYSTEMS

UNIVERSITY SERIES Fixed, Projected and Casement Steel Windows

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

Storage and Installation of welded LL Hollow Metal Door Frames in Steel Studs

SECTION SHEET METAL FLASHING AND TRIM

Product Guide Specification

JAMESTOWN175 SERIES Fixed, Projected and Casement Steel Windows

PATHWAY 3G MODULAR ACCESS SYSTEM

Transcription:

Series 2030 Picture Window Series 9000 Vinyl Fixed Window Contents List of Architectural Drawings... 9000PW - 3 Elevations - 9000 Fixed... 9000PW - 4 Available Sizes - 9000 Fixed... 9000PW - 5 Elevations, cont. - 9000 Fixed... 9000PW - 6 Available Sizes, cont. - 9000 Fixed... 9000PW - 7 Elevations, cont. - 9000 Fixed... 9000PW - 8 Available Sizes, cont. - 9000 Fixed... 9000PW - 9 Series 9000 Fixed Window specification... 9000PW - 11 Series 9000PW Test Data: AAMA Structural Performance... 9000PW - 15 Series 9000PW Test Data: NFRC Thermal Performance... 9000PW - 15 Architectural Drawings... 9000PW - 18

9000PW - 2 PHONE:1-800-322-8050 FAX: 1-509-453-6143 5/2014

Fixed Series 9000 List of Architectural Drawings Fixed window, horizontal and vertical section (9000PW_1.dwg)... 9000PW - 18 Fixed window, horizontal and vertical detail (9000PW_1d.dwg)... 9000PW - 19 Fixed t-barred to fixed, horizontal and vertical section (9000PW_2.dwg)... 9000PW - 20 Fixed t-barred to fixed, horizontal and vertical detail (9000PW_2d.dwg)... 9000PW - 21 Fixed with divider, horizontal and vertical section (9000PW_4.dwg)... 9000PW - 22 Fixed with divider, horizontal and vertical detail (9000PW_4d.dwg)... 9000PW - 23 Fixed mulled to fixed, horizontal and vertical section (9000PW_5.dwg)... 9000PW - 24 Fixed mulled to fixed, horizontal and vertical detail, vent (9000PW_5d.dwg)... 9000PW - 25 List of Architectural Drawings 5/2014 PHONE:1-800-322-8050 FAX: 1-509-453-6143 9000PW - 3

Fixed Series 9000 Elevations - 9000 Fixed Elevations - 9000 Fixed 9000PW - 4 PHONE:1-800-322-8050 FAX: 1-509-453-6143 5/2014

Fixed Series 9000 Available Sizes - 9000 Fixed Local: (509) 248-4462 U.S., Alaska, Hawaii: (800) 322-8050 FAX: (509) 453-6143 9000 Picture Windows Rough Opening Width 12 18 24 30 36 42 48 54 60 12 18 x 12 24 x 12 30 x 12 36 x 12 42 x 12 48 x 12 54 x 12 60 x 12 Rough Opening Height 18 12 x 18 18 x 18 24 x 18 30 x 18 36 x 18 42 x 18 48 x 18 54 x 18 60 x 18 24 12 x 24 18 x 24 24 x 24 30 x 24 36 x 24 42 x 24 48 x 24 54 x 24 60 x 24 30 12 x 30 18 x 30 24 x 30 30 x 30 36 x 30 42 x 30 48 x 30 54 x 30 60 x 30 36 12 x 36 18 x 36 24 x 36 30 x 36 36 x 36 42 x 36 48 x 36 54 x 36 60 x 36 42 12 x 42 18 x 42 24 x 42 30 x 42 36 x 42 42 x 42 48 x 42 54 x 42 60 x 42 48 12 x 48 18 x 48 24 x 48 30 x 48 36 x 48 42 x 48 48 x 48 54 x 48 60 x 48 54 12 x 54 18 x 54 24 x 54 30 x 54 36 x 54 42 x 54 48 x 54 54 x 54 60 x 54 60 12 x 60 18 x 60 24 x 60 30 x 60 36 x 60 42 x 60 48 x 60 54 x 60 60 x 60 66 12 x 66 18 x 66 24 x 66 30 x 66 36 x 66 42 x 66 48 x 66 54 x 66 60 x 66 72 12 x 72 18 x 72 24 x 72 30 x 72 36 x 72 42 x 72 48 x 72 54 x 72 60 x 72 Available Sizes - 9000 Fixed 5/2014 PHONE:1-800-322-8050 FAX: 1-509-453-6143 9000PW - 5

Fixed Series 9000 Elevations - 9000 Fixed Elevations, cont. - 9000 Fixed 9000PW - 6 PHONE:1-800-322-8050 FAX: 1-509-453-6143 5/2014

Fixed Series 9000 Available Sizes - 9000 Fixed Local: (509) 248-4462 U.S., Alaska, Hawaii: (800) 322-8050 FAX: (509) 453-6143 9000 Picture Windows Rough Opening Width 66 72 78 84 90 12 66 x 12 72 x 12 78 x 12 84 x 12 90 x 12 Rough Opening Height 18 66 x 18 72 x 18 78 x 18 84 x 18 90 x 18 24 66 x 24 72 x 24 78 x 24 84 x 24 90 x 24 30 66 x 30 72 x 30 78 x 30 84 x 30 90 x 30 36 66 x 36 72 x 36 78 x 36 84 x 36 90 x 36 42 66 x 42 72 x 42 78 x 42 84 x 42 90 x 42 48 66 x 48 72 x 48 78 x 48 84 x 48 90 x 48 54 66 x 54 72 x 54 78 x 54 84 x 54 90 x 54 60 66 x 60 72 x 60 78 x 60 84 x 60 90 x 60 66 66 x 66 72 x 66 78 x 66 84 x 66 72 66 x 72 72 x 72 78 x 72 Available Sizes, cont. - 9000 Fixed 5/2014 PHONE:1-800-322-8050 FAX: 1-509-453-6143 9000PW - 7

Fixed Series 9000 Elevations - 9000 Fixed Elevations, cont. - 9000 Fixed 9000PW - 8 PHONE:1-800-322-8050 FAX: 1-509-453-6143 5/2014

Fixed Series 9000 Available Sizes - 9000 Fixed Local: (509) 248-4462 U.S., Alaska, Hawaii: (800) 322-8050 FAX: (509) 453-6143 9000 Picture Windows Rough Opening Width 96 102 108 114 120 12 96 x 12 Rough Opening Height 18 96 x 18 102 x 18 108 x 18 114 x 18 120 x 18 24 96 x 24 102 x 24 108 x 24 114 x 24 120 x 24 30 96 x 30 102 x 30 108 x 30 114 x 30 120 x 30 36 96 x 36 102 x 36 108 x 36 114 x 36 120 x 36 42 96 x 42 102 x 42 108 x 42 114 x 42 120 x 42 48 96 x 48 102 x 48 108 x 48 114 x 48 120 x 48 54 96 x 54 102 x 54 60 96 x 60 66 72 Available Sizes, cont. - 9000 Fixed 5/2014 PHONE:1-800-322-8050 FAX: 1-509-453-6143 9000PW - 9

9000PW - 10 PHONE:1-800-322-8050 FAX: 1-509-453-6143 5/2014

Series 9000 Picture Specification I. GENERAL REQUIREMENTS A. Provide Prime Window Systems Series 9000 Picture windows where shown on the drawings, according to the following specifications. B. Work Included: 1. Shop fabricated rigid polyvinyl chloride (PVC) windows. 2. Shop glazing. C. Quality Assurance: 1. Manufacturer must have been in production of vinyl windows for at least five years. 2. Products must be individually labeled with NFRC Thermal Certification, and AAMA Structural Certification labels, indicating the specified performance level. 3. All extrusions used must be listed in the AAMA Certified PVC Extrusions Directory for conformance to AAMA 109 procedures. 4. Windows must be installed plumb and true into prepared openings in accordance with approved shop drawings or the latest version of AAMA 2400 or ASTM E2112. D. Delivery, Storage, and Handling: 1. Deliver windows to jobsite. 2. Identify each window with series type, U-factor, and work order number. 3. Store off ground, on a flat surface in a near vertical position, under cover and protected from weather. E. Warranty: 1. Residential - Limited lifetime warranty coverage shall be provided for as long as the original owner owns the home. Warranty coverage shall include defects in materials and/or workmanship in vinyl material products manufactured by Prime Window Systems, Yakima, Washington. 2. Multi-Family - If Prime Window Systems products are installed in nonowner multi-family occupied dwellings then this warranty is limited to 10- Years on parts and 1 year on labor from the date of delivery. 3. Commercial - Limited warranty coverage shall be extended for a 2 year period on commercial applications, excluding parts and labor. 4. Terms of the warranty, limitations, and conditions of the warranty coverage shall be available by contacting Prime Window Systems.

Series 9000 Picture Window Specification F. System Performance: AAMA/WDMA/CSA 101/I.S.2/A440-2005 Performance Class FW-C45 (96 x 60); AAMA/WDMA/CSA 101/I.S.2/A440-2008 Performance Class CW-PG45 (96 x 60)-Type FW. 1. Air Infiltration : Not to exceed 0.1 CFM at 1.57 PSF in accordance with ASTM E283. * note 1 2. Water Resistance : No leakage when subjected to 12.00 PSF for four, five minute cycles per ASTM E547. 3. Structural : No damage after structural loading of 67.5 PSF per ASTM E330. 4. Thermal : U-factor not to exceed 0. * note 2 when tested in accordance with NFRC 100-2010 procedures. Each unit shall bear a NFRC certification label. II. PRODUCTS A. Series 9000 Picture Windows as manufactured by: Prime Window Systems, 3400 Tacoma Street, Union Gap, WA 98903 1-800-322-8050 B. Materials: 1. Frames, sash, mullions, and snap-in dry glazing bead members: High impact rigid polyvinyl chloride ( PVC), compounded specifically for windows and doors. Material must meet ASTM Standard D 4726 and shall be lead-free. Frame width shall be 3 1 /4" minimum with an integrally extruded nailing flange. 2. Available colors: standard colors are white, almond (beige) and adobe; premium exterior color is dark brown exterior with white interior. 3. Fasteners: Stainless steel, or corrosion resistant finish. 4. Insulating glass: Hermetically sealed units, ¾" overall thickness. Glazing shall be a minimum of float quality and of adequate strength for the size and use intended. C. Fabrication & Construction: 1. Windows must be constructed in a neat and workmanlike manner. All frame and sash corner joints shall be miter cut and fusion welded. Welds are to be dressed and finished to match the surrounding surfaces. 2. PVC window members shall have an integral white, almond or adobe color throughout the profile. Exposed surfaces shall be smooth and uniform in appearance.

Series 9000 Picture Window Specification 3. Brown exterior finish (when specified) shall utilize solar reflective polyurethane coatings. To prevent deformation and separation, solid brown extrusions and multi-layer co-extrusions will not be allowed. 4. An internal drainage shall be incorporated into the frame. 5. Glass units shall be held in place by an AAMA approved internal glazing tape and an externally mounted glazing bead. Glazing tape positioned on the exterior glazing surfaces shall not be permitted. Glass units must be supported by load- bearing setting blocks. D. Installation: 1. Windows shall be installed by experienced workmen in accordance with architect s instructions and architect s drawings. 2. Proper window installation methods are the responsibility of the architect and/or builder. Recommended installation methods are not the responsibility of Prime Window Systems, Yakima, Washington. Please refer to the latest version of AAMA 2400 or ASTM E2112 for installation procedures. DI. Cleaning 1. All vinyl and glass must be cleaned inside and out. Temporary labels shall be removed, leaving the NFRC and AAMA labels for final inspection. Under no circumstances should solvents be used for cleaning. END OF SECTION ARCHITECT S NOTES: Note 1: Product surpasses AAMA requirement of 0.3 cfm per square foot. Note 2: To specify a U-factor, select from the chart below. A complete chart of NFRC tested U- factors is found in the test data section. NFRC CERTIFIED U - FACTORS 3/4" O.A. glazing Low E Glass* and Argon U-factor = 0.27 1 1/8" O.A. glazing Triple pane, Low E* and Argon U-factor = 0.16 * Standard - Cardinal LoE 2-272 (.04 emissivity)

9000PW - 14 PHONE:1-800-322-8050 FAX: 1-509-453-6143 5/2014

Series 9000PW Test Data: NFRC Thermal Performance Series 9000 Fixed Window Test Data AAMA Certified Structural Performance Class FW-C45 Air Infiltration: <0.1 CFM at 1.57 PSF in accordance with ASTM E283. Water Resistance: No leakage when subjected to 12.0 PSF for four, five minute cycles per ASTM E547. Structural: No damage after structural loading of 67.5 PSF per ASTM E330. FW-C45: 96 x 60 test size NFRC Certified Thermal Performance In accordance with NFRC 100-2010 and 200-2010 procedures SHGC VT SHGC VT 9000PW Glazing Description U-Factor No Grids No Grids Grids <1" Grids <1" 3/32 LoE 2-272, Argon, 0.75" OA 0.27 0.44 0.63 0.40 0.57 1/8 LoE 2-272, Argon, 0.75" OA 0.26 0.44 0.63 0.40 0.56 1/8 LoE 2-272, Argon, 0.75" OA, Sculpt Grid 0.28 0.40 0.56 3/16 LoE 2-272, Argon, 0.75" OA, No Grid 0.28 0.43 0.62 3/16 LoE 2-272, Argon, 0.75" OA, Grid 0.29 0.38 0.55 3/32 LoE 3-366, Argon, 0.75" OA 0.26 0.24 0.57 0.22 0.51 1/8 LoE 3-366, Argon, 0.75" OA 0.26 0.24 0.56 0.22 0.51 1/8 LoE 3-366, Argon, 0.75" OA, Sculpt Grid 0.27 0.22 0.51 3/16 LoE 3-366, Argon, 0.75" OA, No Grid 0.27 0.24 0.55 3/16 LoE 3-366, Argon, 0.75" OA, Grid 0.29 0.22 0.50 1/8 LoE-180, Argon, 0.75" OA 0.27 0.60 0.69 0.54 0.62 1/8 LoE-180, Argon, 0.75" OA, Sculpt Grid 0.29 0.54 0.62 3/16 LoE-180, Argon, 0.75" OA, No Grid 0.29 0.57 0.68 3/16 LoE-180, Argon, 0.75" OA, Grid 0.30 0.52 0.61 1/8 LoE 2-272, LoE i89, Argon, 0.75" OA 0.22 0.35 0.61 0.32 0.55 1/8 LoE 2-272, LoE i89, Argon, 0.75" OA, Sculpt Grid 0.23 0.32 0.55 3/16 LoE 2-272, LoE i89, Argon, 0.75" OA, No Grid 0.23 0.35 0.60 3/16 LoE 2-272, LoE i89, Argon, 0.75" OA, Grid 0.25 0.31 0.54 1/8 LoE 3-366, LoE i89, Argon, 0.75" OA 0.21 0.23 0.55 0.21 0.49 1/8 LoE 3-366, LoE i89, Argon, 0.75" OA, Sculpt Grid 0.23 0.21 0.49 3/16 LoE 3-366, LoE i89, Argon, 0.75" OA, No Grid 0.22 0.24 0.54 3/16 LoE 3-366, LoE i89, Argon, 0.75" OA, Grid 0.25 0.21 0.49 1/8 LoE-180, LoE i89, Argon, 0.75" OA 0.22 0.54 0.67 0.49 0.61 1/8 LoE-180, LoE i89, Argon, 0.75" OA, Sculpt Grid 0.24 0.49 0.61 3/16 LoE-180, LoE i89, Argon, 0.75" OA, No Grid 0.24 0.52 0.66 3/16 LoE-180, LoE i89, Argon, 0.75" OA, Grid 0.26 0.47 0.59 3/16 LoE 2-272, Argon, 1-1/8" OA 0.27 0.43 0.62 0.39 0.55 3/16 LoE 3-366, Argon, 1-1/8" OA 0.27 0.24 0.55 0.22 0.50 3/16 LoE-180, Argon, 1-1/8" OA 0.28 0.58 0.68 0.52 0.61 3/16 LoE 2-272, LoE i89, Argon, 1-1/8" OA 0.22 0.35 0.60 0.31 0.54 3/16 LoE 3-366, LoE i89, Argon, 1-1/8" OA 0.22 0.23 0.54 0.21 0.49 3/16 LoE-180, LoE i89, Argon, 1-1/8" OA 0.23 0.52 0.66 0.47 0.59 5/2014 PHONE:1-800-322-8050 FAX: 1-509-453-6143 9000PW - 15

Series 9000 Fixed Window Test Data NFRC Certified Thermal Performance In accordance with NFRC 100-2010 and 200-2010 procedures SHGC VT SHGC VT 9000PW Glazing Description U-Factor No Grids No Grids Grids <1" Grids <1" 3/32 LoE 2-272 (1), Argon, 1-1/8" triple glaze 0.21 0.42 0.58 0.38 0.52 1/8 LoE 2-272 (1), Argon, 1-1/8" triple glaze 0.22 0.41 0.57 0.37 0.51 3/16 LoE 2-272 (1), Argon, 1-1/8" triple glaze 0.26 0.40 0.56 0.36 0.50 3/32 LoE 2-272 (2), Argon, 1-1/8" triple glaze 0.16 0.31 0.51 0.28 0.46 1/8 LoE 2-272 (2), Argon, 1-1/8" triple glaze, No Grid 0.17 0.31 0.50 1/8 LoE 2-272 (2), Argon, 1-1/8" triple glaze, Grid 0.18 0.28 0.45 3/16 LoE 2-272 (2), Argon, 1-1/8" triple glaze, No Grid 0.21 0.30 0.49 3/16 LoE 2-272 (2), Argon, 1-1/8" triple glaze, Grid 0.22 0.27 0.44 3/32 LoE 3-366 (1), Argon, 1-1/8" triple glaze 0.21 0.22 0.52 0.2 0.47 1/8 LoE3-366 (1), Argon, 1-1/8" triple glaze 0.22 0.22 0.52 0.2 0.46 3/16 LoE 3-366 (1), Argon, 1-1/8" triple glaze, No Grid 0.25 0.23 0.50 3/16 LoE 3-366 (1), Argon, 1-1/8" triple glaze, Grid 0.26 0.21 0.45 3/32 LoE 3-366 (2), Argon, 1-1/8" triple glaze 0.16 0.22 0.46 0.2 0.41 1/8 LoE 3-366 (2), Argon, 1-1/8" triple glaze, No Grid 0.17 0.22 0.45 1/8 LoE 3-366 (2), Argon, 1-1/8" triple glaze, Grid 0.18 0.2 0.40 3/16 LoE 3-366 (2), Argon, 1-1/8" triple glaze, No Grid 0.21 0.22 0.44 3/16 LoE 3-366 (2), Argon, 1-1/8" triple glaze, Grid 0.22 0.2 0.39 1/8 LoE-180 (1), Argon, 1-1/8" triple glaze 0.23 0.54 0.63 0.49 0.57 3/16 LoE-180 (1), Argon, 1-1/8" triple glaze 0.26 0.51 0.62 0.46 0.55 1/8 LoE-180 (2), Argon, 1-1/8" triple glaze, No Grid 0.18 0.49 0.61 1/8 LoE-180 (2), Argon, 1-1/8" triple glaze, Grid 0.19 0.44 0.55 3/16 LoE-180 (2), Argon, 1-1/8" triple glaze, No Grid 0.22 0.46 0.59 3/16 LoE-180 (2), Argon, 1-1/8" triple glaze, Grid 0.23 0.42 0.53 1/8 LoE 2-272, LoE-180, LoE i89, Argon, 1-1/8" triple 0.16 0.31 0.54 0.28 0.48 1/8 LoE 3-366, LoE-180, LoE i89, Arg, 1-1/8" triple, no grid 0.15 0.21 0.48 1/8 LoE 3-366, LoE-180, LoE i89, Argon, 1-1/8" triple, grid 0.16 0.19 0.43 1/8 LoE-180, LoE-180, LoE i89, Arg, 1-1/8" triple, no grid, temp 0.16 0.46 0.59 1/8 LoE-180, LoE-180, LoE i89, Arg, 1-1/8" triple, grid, temp 0.17 0.38 0.48 SHGC = Solar Heat Gain Coefficient; VT = Visible Transmittance Cardinal LoE 2-272: medium solar gain Low E for standard window applications; Cardinal LoE 3-366: low solar gain Low E for solar control applications; Cardinal LoE-180: high solar gain Low E for passive solar applications; LoE i89: interior surface Low E coating for maximum energy efficiency. Triple glaze: (1) denotes Low-E on one pane; (2) denotes Low-E on two panes. LoE 3-366 (2) uses Cardinal LoE 3-366 at the exterior pane and Cardinal LoE 2-272 at the interior pane of the triple glazed insulating glass unit. Sculptured grid is not available in triple-glazed units. Test data is subject to change without notice - consult factory for current values 5/2014 9000PW - 16 PHONE:1-800-322-8050 FAX: 1-509-453-6143 5/2014

5/2014 PHONE:1-800-322-8050 FAX: 1-509-453-6143 9000PW - 17

Architectural Drawings Fixed window, horizontal and vertical section (9000PW_1.dwg) NOT TO BE REPRODUCED WITHOUT EXPRESS PERMISSION OF PRIME WINDOW SYSTEMS 9000 Series, Picture Window Horizontal, Vertical Section Scale: Full Scale Drawing name: 9000PW_1.dwg Date: 3/23/12 Drafted by: CDY Prime Window Systems, 3400 Tacoma Street, Union Gap, Washington, 98903.

Fixed window, horizontal and vertical detail (9000PW_1d.dwg) NOT TO BE REPRODUCED WITHOUT EXPRESS PERMISSION OF PRIME WINDOW SYSTEMS 9000 Series, Picture Window Horizontal, Vertical Detail Scale: Full Scale Drawing name: 9000PW_1d.dwg Date: 3/23/12 Drafted by: CDY Prime Window Systemss, 3400 Tacoma Street, Union Gap, Washington, 98903.

Fixed t-barred to fixed, horizontal and vertical section (9000PW_2.dwg) NOT TO BE REPRODUCED WITHOUT EXPRESS PERMISSION OF PRIME WINDOW SYSTEMS 9000 Series PW, T-bar Mullion Horizontal, Vertical Section Scale: 3/4 Scale Drawing name: 9000PW_2.dwg Date: 7/13/12 Drafted by: CDY Prime Window Systems, 3400 Tacoma Street, Union Gap, Washington, 98903.

Fixed t-barred to fixed, horizontal and vertical detail (9000PW_2d.dwg) NOT TO BE REPRODUCED WITHOUT EXPRESS PERMISSION OF PRIME WINDOW SYSTEMS 9000 Series Picture, T-bar Mullion Horizontal, Vertical Detail Scale: Full Scale Drawing name: 9000PW_2d.dwg Date: 3/23/12 Drafted by: CDY Prime Window Systems, 3400 Tacoma Street, Union Gap, Washington, 98903.

Fixed with divider, horizontal and vertical section (9000PW_4.dwg) NOT TO BE REPRODUCED WITHOUT EXPRESS PERMISSION OF PRIME WINDOW SYSTEMS 9000 Series Picture Window Horizontal, Vertical Section- Divider Bar Scale: 3/4 Scale Drawing name: 9000PW_4.dwg Date: 7/3/12 Drafted by: CDY Prime Window Systems, 3400 Tacoma Street, Union Gap, Washington, 98903.

Fixed with divider, horizontal and vertical detail (9000PW_4d.dwg) NOT TO BE REPRODUCED WITHOUT EXPRESS PERMISSION OF PRIME WINDOW SYSTEMS 9000 Series, Picture Window Horizontal, Vertical Detail- Divider Bar Scale: Full Scale Drawing name: 9000PW_4d.dwg Date: 3/23/12 Drafted by: CDY Prime Window Systems, 3400 Tacoma Street, Union Gap, Washington, 98903.

Fixed mulled to fixed, horizontal and vertical section (9000PW_5.dwg) NOT TO BE REPRODUCED WITHOUT EXPRESS PERMISSION OF PRIME WINDOW SYSTEMS 9000 Series PW, Reinforcing Mullion Horizontal, Vertical Section Scale: 3/4 Scale Drawing name: 9000PW_5.dwg Date: 7/3/12 Drafted by: CDY Prime Window Systems, 3400 Tacoma Street, Union Gap, Washington, 98903.

Fixed mulled to fixed, horizontal and vertical detail, vent (9000PW_5d.dwg) NOT TO BE REPRODUCED WITHOUT EXPRESS PERMISSION OF PRIME WINDOW SYSTEMS 9000 Series Picture, Reinforcing Mullion Horizontal, Vertical Detail Scale: Full Scale Drawing name: 9000PW_5d.dwg Date: 7/3/12 Drafted by: CDY Prime Window Systems, 3400 Tacoma Street, Union Gap, Washington, 98903.

9000PW - 26 PHONE:1-800-322-8050 FAX: 1-509-453-6143 5/2014