E Series 9.00 (1/2) E series

Similar documents
10.00 (1/2) PAC series

AC/DC current clamps (1/2) E N series

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

Current clamps for AC current

AC/DC Current Oscilloscope Probe Model SL261

Flexible AC current probes

Current clamps for AC current

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Agilent 1146A AC/DC Oscilloscope Current Probe

Current clamps for AC current

current clamps catalogue

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

AC/DC Current Probes Model MR411 Model MR521


1587/1577 Insulation Multimeters

MR461 MR561 AC/DC OSCILLOSCOPE CURRENT PROBES. User Manual. AC/DC CURRENT PROBE Model MR 561. AC/DC CURRENT PROBE Model MR V CAT III - 600A

FLEXIBLE CURRENT PROBES

Current Clamps. Catalogue

Wide-band Models from DC to 100 MHz

Variable-Gain High Speed Current Amplifier

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

K1 K2. User's manual AC/DC CURRENT PROBE C H A U V IN A R N O U X AC/DC CURRENT PROBE. 1 mv/ma OFF 300V CAT II

FlexProbe FLEXIBLE AC CURRENT PROBE. User Manual. FlexProbe ON OL 1000V CAT III 300A 3000A OFF

79/26 Series III Multimeter

GAMMA 20 DIGITAL MULTIMETER

80i-110s AC/DC CURRENT PROBE

Analog Digital Multimeter with Insulation Resistance Measurement

AC FLEXIBLE CURRENT PROBE CA 3000

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

Fluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

ATK Clamp Meter

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

Current Clamp. 210

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

Fluke 83V and 87V Digital Multimeters

CA60 ma Current Clamp

SUBJECT TO CHANGE WITHOUT NOTICE

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

METRAClip87 and 88 Clamp Multimeters

Wide-band Models from DC to 100 MHz

MiniFlex MF MF FLEXIBLE AC CURRENT SENSOR. User Manual

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Preface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention

Fluke 370 FC Series true-rms wireless AC/DC clamp meters

Wide-band Models from DC to 100 MHz

TORKEL 900-series Battery Load Unit

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

Indeks: WMXXCMM60 Advanced Industrial Multimeter

User s Guide. 400A AC/DC Clamp Meter. Model MA220

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

APPA 300 Series. The Most User-Friendly High Performance Multimeter

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

MS2030 CAT III 600 V A V AUTO RS232

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, this instruction manual is the description about t

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, the product specification is about the function, u

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

BENNING. CM7 Electrical Tester. Service Information

METRAClip85 and 86 Clamp Multimeters

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

SPECIFICATION Item no.: T60404-N4646-X764

TORKEL 900-series Battery Load Unit

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

CPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,

Data sheet IDM 99III Digital Multimeter

Digital Clamp Meter Model: &

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

200Amp AC Clamp Meter + NCV Model MA250

GAMMA 12 DIGITAL MULTIMETER

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

IDM 503 & 505 Digital Multimeters

DC MHZ PXI Differential Instrumentation Amplifier

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

Model 77 Series IV. Digital Multimeter. Users Manual

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Pen-type DIGITAL MULTITESTER

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

AC/DC CLAMP METER USER S MANUAL

MiniFlex MF HF MF HF FLEXIBLE AC CURRENT SENSOR. User Manual. High Frequency Response for Oscilloscopes

F 03. Pince multimètre Clamp multimeter Vielfachmesszange Pinza multimetro Pinza multimetrica

# Digital Multimeter

AC/DC Current Measurement Systems

GAMMA 10 DIGITAL MULTIMETER

LH240 LH1040 LH2040 LH2015

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

Fluke 170 Series True-rms Digital Multimeters

Data sheet IDM 98III Digital Multimeter

2000 A DCA/ACA CLAMP + DMM,

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Fluke 1587 FC/1577 Insulation Multimeters

FINE INSTRUMENTS CORPORATION

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Agilent 970-Series Handheld Multimeters Data Sheet

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

NOTE: Fully read and understand this manual before using this Digital Multimeter.

UT207/208. Digital Clamp Multimeter P/N:

Transcription:

Clamp-on AC/DC current probes E Series The clamps use Hall effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. The elongated, narrow design of these clamps makes it possible to probe into tight spaces which comes into it s own when carrying out measurements in cable bundles or in other restrictive areas like circuit boards, motor controls or motor vehicle electric s. Their inherent low phase shifting also goes to ensure reliable and accurate power measurements. These clamps have a voltage output (mv) and their ability to measure AC and DC signals is useful for true RMS measurements. Model E6N is the most sensitive and hence the most suited to low current measurement. The E Series clamps all make excellent work mates for multimeters, recorders and logging equipment etc. Model E3N can be used directly linked up to an oscilloscope. 101 974 - Ed 1-00 9.00 (1/2)

Ø 11,8 mm max + I + Zero 231 mm 67 mm 36 mm Title : Drawing N Drawn: Manufactured by: 101 974 - Ed 1-00 9.00 (2/2)

Clamp-on AC/DC current probe Model E1N Current 2 A AC/DC 150 A AC/DC Ouput 1 mv/ma 1 mv/a Current Range: 50 ma...150 A AC/DC on two ranges 1 mv/ma and 1 mv/a AC or DC Accuracy and phase shift (1): Range 1 mv/ma (1 V/A) 1 mv/a Current range 50 ma...2 A DC 500 ma...150 A 50 ma...1.5 A AC % Accuracy of 2% ±20 mv 500 ma...100 A AC/DC : output signal 1.5% ±30 µv 100...150 A DC : 3% 100...120 A AC : 3% Frequency range DC...2 khz DC...8 khz Phase shift DC...65 Hz : 3 DC...65 Hz : 1 Min. load impedance 10 kω 2 kω Noise DC...1 Hz : 3 mv DC...1 Hz : 3 µv 1 Hz...10 khz : 10 mv 1 Hz...10 khz : 10 µv 10...100 khz : 18 mv 10...100 khz : 18 µv (EC Stamp): - Electrical discharge IEC 1000-4-2 - Radial Field IEC 100-4-3 - Rapid Transients IEC 1000-4-4 - Magnetic Field to 50/60 Hz IEC 1000-4-8 70 Hrs approx. 6 ma Temperature influence: < 0.2% per C Operating relative humidity: +10 to +30 C : 85 ±5% RH (without condensation) +4 : 45 ±5% RH (without condensation) Operating altitude: 11.8 mm 20 turn potentiometer (± 1.5 A min) 1 m on a 38 mm container of oak on concrete, test in accordance with IEC 1010 IP20 in accordance with IEC 529 Casing : UL94 V2 330 g with batteries Via 1.5 m double-wound cable with reinforced or double insulation, ended with two elbowed 4mm male safety plugs. (1) Conditions : 23 C ±5 K, 20 to 75% RH, 48 to 65 Hz, external magnetic field < 40 A/m, no current carrying conductor nearby, centred test sample, load impedance 1 MΩ Clamp on AC/DC current probe model E1N with battery and user s manual P01.1200.30A 101 974 - Ed 1-01 9.01 (1/1)

Clamp-on AC/DC current probe for oscilloscope use Model E3N (Insulated current probe) Current 10 A peak 100 A peak Ouput 100 mv/a 10 mv/a In mv (1000 mv peak max) Accuracy and phase shift (1): Range 100 mv/a 10 mv/a Current range 50 ma...10 A peak 1 A...100 A peak % Accuracy of 3% ±5 mv 500 ma...40 A peak: Output signal 4% ±500 µv 40...100 A peak : 15% max at 100 A Frequency Range DC...100 khz (-3 db) Phase shift DC...65 Hz: < 1.5 DC...65 Hz: < 1 1 MΩ and 100 pf Insertion Impedance 0.01 Ω Noise 6 mv 600 µv Slew Rate 0.3 V/µs 20 mv/µs Rise/Fall Time 3 µs 4 µs Influence of adjacent conductor: < 0.2 ma/a AC Influence of conductor positioning in the clamp s jaws: 0.5% of the reading at 1 khz 55 Hrs approx. 8.6 ma Overload indicator : Red LED indicates the measured current is too high for the selected range. Temperature Influence: < 0.2% per C Operating Relative Humidity: +10 to +30 C: 85 ±5% RH (without condensation) +4: 45 ±5% RH (without condensation) Operating altitude: 11.8 mm Ø 20 turn potentiometer 1 m on a 38 mm container of oak on concrete, test in accordance with IEC 1010 IP20 in accordance with IEC 529 Casing : UL94 V2 330 g with battery Via 2 m coaxial cable ended with BNC insulated plug. (EC Stamp): - Electrical Discharge IEC 1000-4-2 - Radial Field IEC 100-4-3 - Rapid transients IEC 1000-4-4 - Magnetic Field to 50/60 Hz IEC 1000-4-8 (1) Conditions: 23 C ±5 K, 20 to 75% RH, 48 to 65 Hz, external magnetic field < 40 A/m, no current carrying conductor nearby, centred test sample, load impedance 1 MΩ Clamp-on AC/DC current probe model E3N for oscilloscope use, with battery and user s manual P01.1200.43A 101 974 - Ed 1-02 9.02 (1/1)

Clamp-on AC/DC current probe Model E6N Current 2 A AC/DC 80 A AC/DC Ouput 1 mv/ma 10 mv/a Current range: 5 ma...80 A AC/DC on two ranges 1 mv/ma and 10 mv/a AC or DC Accuracy and Phase shift (1): Range 1 mv/ma (1 V/A) 10 mv/a Current range 5 ma...2 A DC 20 ma...80 A DC 5 ma...1.5 A AC 20 ma...80 A AC % Accuracy of output signal 2% ±5 mv 20 ma...50 A DC: 4% ±200 µv 50 to 80 A DC: 12% 20 ma...40 A AC: 4% ±200 µv 40 to 60 A AC: 12% Frequency range DC...2 khz DC...8 khz Phase shift DC...65 Hz: 1 DC...65 Hz: 1 Min. load impedance > 10 kω > 2 kω Noise DC...1 Hz: 2 mv DC...1 Hz: 20 µv 1 Hz...10 khz: 10 mv 1 Hz...10 khz: 100 µv 10...100 khz: 10 mv 10...100 khz: 100 µv Overload: 120 A continuous 70 Hrs approx. 6 ma Temperature influence: < 0.2% par C Operating Relative Humidity: +10 to +30 C: 85 ±5% RH (without condensation) +4: 45 ±5% RH (without condensation) Operating Altitude: 11.8 mm 20 turn potentiometer (± 1.5 A min) 1 m on 38 mm of oak on concrete, test in accordance with IEC 1010 IP20 in accordance with IEC529 Casing: UL94 V2 330 g with battery Via 1.5 m double wound cable with reinforced or double insulation, ended with two elbowed 4 mm male safety plugs. (EC stamp): - Electrical discharge IEC 1000-4-2 - Radial field IEC 100-4-3 - Rapid transients IEC 1000-4-4 - Magnetic field to 50/60 Hz IEC 1000-4-8 (1) conditions : 23 C ±5 K, 20 to 75% RH, 48 to 65 Hz, external magnetic field < 40 A/m, no current carrying wire nearby, centred test sample, load impedance 1 MΩ Clamp-on AC/DC current probe model E6N with battery and user s manual P01.1200.40A 101 974 - Ed 1-03 9.03 (1/1)