IS-3000 SERIES INFRARED SCANNER

Similar documents
Model LS 250 Loop Scanner Operator s Manual. Version

Rota-Sonde DC4500. Smart display with Signal level. Easy alignment with Laser Line. Design for the most difficult applications

Legros sas ZI Portuaire BP 93 bld de Châtillon

INTERPLANT STANDARD - STEEL INDUSTRY

Model OB-ITF Infrared Through-Beam Fiber Optic Optical Barrier Operator s Manual. Version

6.00 INFRARED ANALYZER

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

AEI800L Avid extreme Liquid Cooled Inverter Module Data Sheet REV 00, March AEI800L Liquid Cooled Inverter Module Data Sheet

Model Sono-Trak Transit Time

SPECIFICATION NO Model Automatic GTAW Welding System

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

ELECTRONICS FOR PULSE PICKERS

CXE880 FIBRE OPTIC NODE

Distance Sensors BOD 26K.... with optional Master-Slave-Mode

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

ZM18 Series DATASHEET SENSORPARTNERS.COM. Sensor Partners BVBA Z.1 Researchpark 310 B-1731, Zellik Belgium

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

CXE880 FIBRE OPTIC NODE

RUDOLF Digital power analyzer. Advanced Version

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

CXE880 FIBRE OPTIC NODE

Radar Scanner CRAT20-11/11 - normal beam angle - long range

Portable Multi-Channel Recorder Model DAS240-BAT

The wireless alternative to expensive cabling...

Sarasota CM200 Sarasota HME900 Density Converter Electronics

( F L O W I Z F A M I L Y )

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

SVP CONTROL AND VISUALIZATION OF VOLTAGE, PHASE AND FREQUENCY IN THREE-PHASE LINES WITH NEUTRAL

High precision laser sensors. for dimensional measurement. TPreciCura line

PD300. Transformer, generator and motor protection Data sheet

Photo-electric Amplifier ISG-A123 1-channel automatic amplifier

Target disk flowmeter for liquids and gases

Using the AcuDew Moisture Transmitter

Metis M311 / M322. Highly Advanced, Full Featured 2-Color Pyrometer Series

Compact, Low-Cost Solutions

PROCESS & TEMPERATURE CONTROLLERS

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

CAMTO. Arc detecting relay. system. January Revised August D D1200

Electro-Magnetic Flowmeters COPA-XE

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

KNC-SRV-FD423 Series Servo Driver

DC Electronic Loads 8500 series

The wireless alternative to expensive cabling...

Conductivity Analyzer

Brunata Optuna H. Properties. Counter

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

LASER DIODE SOURCE FIBER OPTIC (SINGLE OR MULTI-WAVELENGTH)

INSTRUCTION MANUAL VIBRATION SWITCH CVS 100 LC

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS

Sultan Liquid- Acoustic Wave Technology

Level Measurement Continuous level measurement Radar transmitters

Analogue temperature controllers

Specification DataFile

LN-25 PRO Wire Feeder

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

SR Series Self-Contained Two-Color Infrared Thermometers

SILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets

Absolute Encoders Multiturn

The wireless alternative to expensive cabling...

Metis H311 / H322. Highly Advanced, Full Featured 2-Color High-Speed Pyrometers

LN-25 PRO Wire Feeder

Photodiode Heads and Instruments

Specification. Scanning Laser Range Finder UTM-30LX/LN C /6. Date: Symbol Amendment Details Amendment Date Amended by Number

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

12. ELECTRONICS & INSTRUMENTATION FOR TEMPERATURE

DC Electronic Loads 8500 Series

Optical laser distance sensors. Dimensioned drawing

3DM phase Digital Stepper Drive

KINAX SR 719 Programmable Transmitter for Position Feedback

ISOMAG UNIQUE PID REGULATOR + MAG CONVERTER THE FRIENDLY MAG METER

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

IFC 010 Signal Converter

DA 30 High Torque Technical Specification

General Specifications

Moving Test - MT3000

Distance sensors. System description. Distance measurement using triangulation

ph or ORP Transmitter

LKAT2 Portable. High Current, Portable, Multi-size Head AC / DC Current Measurement System. Application Examples. Key Features

Metis M311 / M Color Pyrometer Series

Direct Digital Control of package units, VAV boxes, and other terminal unit applications. The TCX 840

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

LST400 Ultrasonic level / open channel flow transmitter

LASER. Analog Laser Displacement Transducer. LAS Series. Key-Features:

INTRODUCTION 提夫自控技术 ( 上海 ) 有限公司 LAS laser sensors cover measurement ranges from 1 to mm. The integrated micro-controller delivers an accur

Coherent Laser Measurement and Control Beam Diagnostics

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

BATAILG TAIL GAS ANALYZER. Rev. 1.1

Model WHD Weld Hole Detector Operator s Manual. Rev 1.1

Triple-IN. Selection table: 3D Scanner PSCXXX-90 Summary: Technical Data. PSCXXX-90 preliminary Technical Data. Triple-IN GmbH PSCXXX-90/14.

8V General information. 2 Order data 8V

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter

DIGITAL LASER DISTANCE METER

NON-AMPLIFIED PHOTODETECTOR USER S GUIDE

3 - Protection components Circuit-breakers

Transcription:

IS-3000 SERIES INFRARED SCANNER NON-CONTACT, RELIABLE, PRECISE, LONG RANGE POSITIONING FOR HOT OR COLD PRODUCTS FEATURES ANALOG AND DIGITAL OUTPUTS INDICATIVE OF TARGET POSITION, WIDTH AND TEMPERATURE TRANSISTOR AND RELAY OUTPUTS FOR DETECTION OF PRODUCT AUTOMATIC GAIN CONTROL ADJUSTABLE SCAN ANGLE FROM 0 to 44 DEGREES RADIANT BAR NOT REQUIRED FOR PRODUCT ABOVE 150 C/ 300 F SET UP and DIAGNOSTICS via HAND-HELD TERMINAL or LAPTOP APPLICATIONS: The IS-3000 is the best-designed and precise scanning system for a broad range of measurement and position applications including: Loop Control Strip Centering Cut-to-Length Crop Shear Optimization Width Control Edge Positioning MADE IN THE USA 2014 IS-3000 INFRARED SCANNER 1

DESCRIPTION: SCANNING PRINCIPLE: The field of view is vertically scanned by a rotating mirror with 20 spherical faces that reflect infrared energy to the photodiode (PbS) (Figure 1). Position information is processed by the electronics, and converted to an analog output, which is proportional to the position of hot product within the field of view (Figure Figure 1 2). The time T between the reference pulse and the measuring pulse is equivalent to the angle a between the beginning of the scanned field and the position of the leading edge of the hot product. The sensor converts the time T into an analog voltage, which is proportional to the angle and independent of the scanning motor speed. The 20 separate measurements taken with each mirror facet are averaged together to provide an extremely accurate measurement with low standard deviation. Cell signals after shaping Figure 2 LE Reference Reference cell IR test source Measuring T: time α Electronic Module V= ka TE Measuring cell The IS-3000 uses a lead sulfide (PbS) photocell. A comparison of different photocells is shown below. Responsivity versus wavelength curves shows that lead sulfide has superior detection capabilities for hot metal. The output level is sufficient to provide reliable detection even with product temperatures as low as 200 C (392 F), and is continuous when the hot product is in the viewing field. These characteristics allow the lead sulfide photocell to provide reliable hot product detection, even through steam, dust and water. IS-3000 (PbS) 2014 IS-3000 INFRARED SCANNER 2

IS3000-HMD: HOT METAL DETECTOR Ultimate end scanning Cold bar detection on roller table IS3000-LS: LOOP SCANNER LE TE α α Radiant bar Hot bars/rods/wires Loop Control Cold Strip Loop Control IS3000-HW: HOT WIDTH AND IS3000-CW: COLD WIDTH Radiant bar Hot plate centering, camber and width measurement Cold strip centering, camber and width measurement Billet & bloom of slab cut to length 2014 IS-3000 INFRARED SCANNER 3

SPECIFICATIONS: SYSTEM SENSITIVITY RANGE DETECTION THRESHOLD ENERGY AUTOMATIC GAIN CONTROL PHOTOCELL OPTIONS Adjustable gain, 6 levels programmable via digital serial link Programmable via digital serial link Available on analog and digital output Enabled via digital link PbS SCANNING ANGLE Full range adjustable between 0º to 44º TEMPERATURE RANGE > 150 C / 300 F SIGNALS DETECT RELAY SOLID STATE OUTPUT DIGITAL OUTPUT RATE ANALOG OUTPUTS (rate 20ms to 1s) FAULT RELAY Triggers on object detected within window Closing time: 7.5 ms / Opening time: 3 ms MOSFET isolated optocoupled relay 0/24 VDC & 24/0 VDC, 100 MA Response time: 2 ms 40 ms to 1 sec Programmable to send selected measurement 4-20 ma (standard), 0-20 ma, 0-10 VDC Triggers on power fault, 4-20mA fault, scanner fault, and over temperature limit ELECTRICAL POWER SUPPLY POWER CONSUMPTION SHIELDED CABLE CONNECTOR SERIAL LINK DIGITAL COMMUNICATION 100 to 240 VAC / 15 W (50-60 Hz) or 24 VDC / 8 W 20 VA or 10 VA for 24V 2 Meter, high-temperature Teflon cable Quick disconnect 15-pin HARTING plug with ground shield RS232, RS422 (long range, transmit only), RS485 duplex MECHANICAL LASER POSITIONING POSITIONING / ALIGNMENT 650nm (red) Class 2 laser Visible laser pointing feature HOUSING Cast aluminium housing rating: IP66 (NEMA 4 ) WATER / AIR COOLING PROTECTIVE HOOD MOUNTING OPERATING TEMPERATURE Removable water / air-cooling jacket Hinged protective hood with positive pressure air purge: 4-16 liters/min at 2 bars (0.14-0.56 ft3/min) at 29 PSI) Fully Adjustable foot mount swivel stand -10 C (14 F) to 60 C (140 F) Above 60 C (140 F) auxiliary cooling is required: 1-2 bars at 1-2 liters/min STORAGE TEMPERATURE -20 C (-4 F) to 70 C (158 F) INSIDE TEMPERATURE TOTAL WEIGHT Alarm (fail safe) Approx.12.25 kg / 27 Lbs. 2014 IS-3000 INFRARED SCANNER 4

Email: sales@ @americansensors.com ACCESSORIES: KHC500: Kevlar Jacket CB3000: Connection Box with LED display HS500: Adjustable stand, support and swivel heat shield (pipe not included) RB3000-PD: Portable radiant bar with diodes. Battery operated RB500: Portable radiant bar to simulate hot target (specify 115 or 230V AC) RB3000: 1-meter long, mill- duty radiant bar KP3000: Keypad Hand-held Terminal PDA3000-PC: 1 Bluetooth transceiver for Sensor or for PC 2014 IS-30000 INFRARED SCANNER 5

DIMENSIONS: ORDERING INFORMATION: Back View Version Input Voltage Electrical Analog Output IS-3000 - HMD Hot Metal Detector DC: 24 V N (standard) 4.20 (4-20 ma) LS Loop Scanner AC: 100 to 240 V DR (direct replacement *) 0.20 (0-20 ma) HW Hot Width ABB compatible LS 0.10 (0-10V) CW Cold Width with RB3000 All sensors are equipped with a 2 meter Teflon-shielded cable with Harting Connector. Please specify additional length, if required OPTIONS & ACCESSORIES: Options Stand Connection Box Radiant Bar Keypad Kevlar Jacket Bluetooth HS500 CB3000 RB500 KP3000 KHC500 PDA-3000-PC RB3000 Example Model Number: IS3000-HW -AC-N-4.20 2014 IS-3000 INFRARED SCANNER 6