ELECTRONICS TESTING CENTER, TAIWAN

Similar documents
ELECTRONICS TESTING CENTER(ETC), TAIWAN

CONFORMANCE TEST REPORT FOR EN /-6

ELECTRONICS TESTING CENTER, TAIWAN

FCC CLASS B COMPLIANCE REPORT (DOC)

ELECTRONICS TESTING CENTER, TAIWAN

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification

TEST REPORT... 1 CONTENT...

EMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

Page 1 of 14 Report No Test Report 2119: EOPENBOX LIMITED. Product: OPENBOX V8S. Commercial-In-Confidence

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

TEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.:

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

CERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

EMC TEST REPORT for Repel-it. REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TABLE OF CONTENTS. Report No.: SZ E01 1. GENERAL INFORMATION... 3

Test report TRFWL. Lotek Wireless Inc. SRX800 SRX A-SRX800. RSS-215 Issue 2, June Date of issue: July 11, 2014.

Report No.: 063L107-RF-CE-P14V02-2. Test Report. MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

FCC Test Report. : ASE Group 4F,No 133, Sec 4, Mingsheng E Rd, Songshan Dist, Taipei, Taiwan

TEST SUMMARY Seite 2 von 31. Prüfbericht - Nr.: Test Report No ANTENNA REQUIREMENT RESULT: Pass

To «Test_Standards» Test of: Radwin Ltd. Outdoor Subscriber Radio Unit. To: FCC CFR 47 Part 15B; ICES-003 Issue 6: 2016

ELECTRONICS TESTING CENTER, TAIWAN Report No.:13-12-RBO-024 EMC TESTING DEPARTMENT Page: 1/24

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

Table of Contents Page Total Page 7 1. General Information

Test Summary Seite 2 von 26. Prüfbericht - Nr.: Test Report No. Page 2 of 26

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release

RF Exposure Evaluation No. ARSQ00016

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

FCC Test Report. Report No.: AGC FE08. Attestation of Global Compliance (Shenzhen) Co., Ltd

CERTIFICATE. Issued Date: Apr. 02, 2009 Report No.: R-ITUSP01V01

TEST REPORT FROM RFI GLOBAL SERVICES LTD

Quality Auditing Institute # Schoolhouse Street, Coquitlam, BC, V3K 4X9, Canada. ISO Accreditation:

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

EMC TEST REPORT For Prokits Industries Co., Ltd.

TABLE OF CONTENTS 1.GENERAL INFORMATION PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) TEST STANDARDS TEST METHODOLOGY...4

FCC Part 15 Subpart B

FCC PART 15B TEST REPORT SZ DJI TECHNOLOGY CO., LTD

CERTIFICATION TEST REPORT

Declaration of Conformity (DoC)

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to

CUSTOM TEST REPORT FCC CFR47: 2007, Part 18, Subpart C, Microwave Oven Operating at ISM Frequency 2450 MHz ±50MHz


TEST REPORT TEST REPORT. Report Number : ETLE Report issue date: May 26, Address : , Gongreung-dong, Nowon-gu, Seoul, Korea

D. Guarnone (verifier)

EMC Test Report. Report No.: AGC EE01 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera

FCC PART & IC RSS GHz FHSS TEST REPORT

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

ELECTRONICS TESTING CENTER, TAIWAN

Test Report No

EMC Test Report. Report Number: M030826

FCC EVALUATION REPORT FOR CERTIFICATION

C E R T I F I C A T I O N

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

RF test report AU01+W02

Test Report. Product Name : IPC Model No.

TEST REPORT. Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China. Shenzhen Innokin Technology Co.

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

HongAn TECHNOLOGY CO., LTD. Report Number: HA VI i

Electromagnetic Compatibility Test Report

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021

Electromagnetic Compatibility Test Report DIGITAL INDICATOR. MarCator 1086 R

FCC PART 95 MEASUREMENT AND TEST REPORT. Powerwerx, Inc.

TEST REPORT. 4F,-4, No.669 Jingping Rd., Zhonghe City, TaiPei county 235, Taiwan R.O.C.

ENGINEERING TEST REPORT

Neutron Engineering Inc.

2004/104/EC Measurement and Test Report

ELECTRONICS TESTING CENTER, TAIWAN

FCC RADIO TEST REPORT

TEST REPORT FROM RFI GLOBAL SERVICES LTD

APPROVED BY: DATE: 19-Aug-2011 Brian Boyea, EMC Engineer. TESTED BY: DATE: 12-Aug-2011 Arturo Ruvalcaba, EMC Engineer

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EMC test report AU01+E04

FCC Report for Parts ,

TEST REPORT. Table of Contents

RADIO TEST REPORT SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD. Prepared By : SHANGHAI EUCHIPS INDUSTRIAL CO.,LTD

QI HARDWARE INC. Ben NanoNote. Model: Ben NanoNote September Report No.: (This report supersedes NONE)

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

IC Test Report. SPORTON INTERNATIONAL INC. No. 52, Hwa Ya 1 st Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.

R. Grant, Wireless Group Manager

Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E

FCC Rules and Regulations / Intentional Radiators. Operational in the MHz, MHz, MHz, and

ELECTRONICS TESTING CENTER, TAIWAN Report No.:14-04-RBO EMC TESTING DEPARTMENT Page: 1/25

EMC Test Report. Client: Wistron NeWeb Corporation. Tested by: Jeremy Pickens, Senior EMC Engineer. Reviewed by: David Schramm, Operations Manager

TEST REPORT. : The submitted samples complied with the above EMC standards. TRF No.: AS NZS (2012)-b

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

TRANSMITTER MODEL: KAS-2030M

Transcription:

Report No.: 13-01-RBP-147 EMC TESTING DEPARTMENT Page: 2/11 CONTENTS EMC TEST REPORT... 1 CONTENTS... 2 1 TEST REPORT CERTIFICATION... 3 2 GENERAL INFORMATIONS... 4 2.1 Description of EUT... 4 2.2 Related Information of EUT... 4 2.3 Tested Configuration... 4 2.4 Deviation Record... 4 2.5 Modification Record... 4 3 LIMITS... 5 3.1 Application of limits... 5 4 GENERAL REQUIREMENTS... 6 4.1 Supply voltage... 6 4.2 Measurement frequency range... 6 4.3 Ambient temperature... 6 4.4 Measurement equipment requirements... 6 5 MEASUREMENT PROCEDURE... 7 5.1 Measurement set-up... 7 6 TEST INSTRUMENT... 8 7 SUMMARY OF TEST RESULTS...9 7.1 Emissions:... 9 8 TEST DATA & RELATED INFORMATIONS... 10 8.1 Emissions:... 10 8.1.1 Household and Similar Electrical Appliance Electromagnetic Fields Test Data:... 10 ANNEX A: Measurement distances... A1 ANNEX B: Location of Measurement test-head... A2 ANNEX C: PHOTOS... A3

Report No.: 13-01-RBP-147 EMC TESTING DEPARTMENT Page: 3/11 1 TEST REPORT CERTIFICATION Client : GlacialTech Inc. Address : 9FL., No. 352, Sec.2, Jung Shan Rd., Jung He City, Taipei (R.O.C.) Manufacturer : GlacialTech Inc. Address : 9FL., No. 352, Sec.2, Jung Shan Rd., Jung He City, Taipei (R.O.C.) EUT : LED Flood Light Trade Name : Model No. Test Standard : GL-FL60XYZ (XYZ maybe any character or number or blank for marketing purpose only) : Emissions IEC62493:2009/EN62493:2010 The testing described in this report has been carried out to the best of our knowledge and ability, and our responsibility is limited to the exercise of reasonable care. This certification is not intended to believe the sellers from their legal and/or contractual obligations.

Report No.: 13-01-RBP-147 EMC TESTING DEPARTMENT Page: 4/11 2.1 Description of EUT 2 GENERAL INFORMATIONS LED Flood Light 2.2 Related Information of EUT Power Supply : 100~277 V, 50/60 Hz, 60 W, 0.75A Power Line : Nonshielded Shielded None, Length: 1.8 m * For more detailed features, please refer to User s Manual. 2.3 Tested Configuration No devices were required. Product Manufacturer Model No. Serial No. I/O Cable -- -- -- -- -- 2.4 Deviation Record (If any deviation from additions to or exclusions from test method must be stated) N/A 2.5 Modification Record No modifications were required. (That is the EUT complied with the requirement as tested.)

Report No.: 13-01-RBP-147 EMC TESTING DEPARTMENT Page: 5/11 3 LIMITS 3.1 Application of limits the measured (weighted and summarized) induced current density due to the electric field in the frequency range 20 khz to 10 MHz does not exceed the factor (F) 0,85 as

Report No.: 13-01-RBP-147 EMC TESTING DEPARTMENT Page: 6/11 4 GENERAL REQUIREMENTS 4.1 Supply voltage Measurements shall be carried out within ±2 % of the maximum rated supply voltage. Equipment which can be operated from an AC- and/or DC supply shall be measured from one AC supply at a single frequency 4.2 Measurement frequency range The measurement frequency range considered is from 20 khz to 10 MHz. 4.3 Ambient temperature Measurements shall be carried out in the ambient temperature range 15 C to 25 C. 4.4 Measurement equipment requirements An electromagnetic interference (EMI) test receiver or spectrum analyzer according to CISPR 16-1-1 is required, with the settings given in Table 2: Table 2 Receiver or spectrum analyzer settings

Report No.: 13-01-RBP-147 EMC TESTING DEPARTMENT Page: 7/11 5 MEASUREMENT PROCEDURE 5.1 Measurement set-up The measurement set-up is given in Figure 3. DUT = device under test. NOTE The EMI receiver or spectrum analyzer must be powered by mains including protective earth. Figure 3 Measurement set-up

Report No.: 13-01-RBP-147 EMC TESTING DEPARTMENT Page: 8/11 6 TEST INSTRUMENT Equipment Manufacturer Model No. Calibration Date Next Cal. Date EMI Test Receiver Rohde & Schwarz ESCI 2012/04/26 2013/04/26 Van der Hoofden Test-Head Protection Network/VDH30 AFJ VDH30 2011/03/28 2013/03/29

Report No.: 13-01-RBP-147 EMC TESTING DEPARTMENT Page: 9/11 7 SUMMARY OF TEST RESULTS 7.1 Emissions: APPLICATION OF LIMITS (Test summary) Specific absorption rate (SAR) a) CISPR 15 clause 4.3.1 13A012803E Disturbance voltage mains terminals 20 khz 30 MHz b) CISPR 15 clause 4.4 13A012803E Radiated electromagnetic disturbances 100 khz 30 MHz c) CISPR 15 clause 4.4.2 Radiated electromagnetic disturbances 30 MHz 300 MHz 13A012803E *) See separate Test Report for measurements of a), b) and c) above Test Report with Ref. No.:.. Only measurement of d) below. See measurement results below. In this case this test report does not show compliance with IEC62493:2009/EN62493:2010. Induced current density d) Induced current density See measurement results 20 khz 10 MHz below

Report No.: 13-01-RBP-147 EMC TESTING DEPARTMENT Page: 10/11 8.1 Emissions: 8 TEST DATA & RELATED INFORMATIONS 8.1.1 Household and Similar Electrical Appliance Electromagnetic Fields Test Data: A. Operating Conditions of the EUT: Operation Mode Test Date: Feb. 02, 2013 Test Specification IEC62493:2009/EN62493:2010 Climatic Condition Ambient Temperature: 25 Relative Humidity: 52 %RH Atmospheric Pressure: 990 mbar Power Supply System AC Power: 230 Vac 50 Hz Measuring Distance(cm): 200 Test Value Limit Test Results 0.027919 0.85 PASS

Report No.: 13-01-RBP-147 EMC TESTING DEPARTMENT Page: 11/11 B. Graph and data please see next page. Site :CHAMBER #2 Date :2013-02-02 Limit :CISPR CLASS-B Ant. Pol. : EUT : Temp. :25 Power Rating :230V/50Hz Humi. :52% Model :GL-FL60XYZ Engineer. : Test Mode : Light on

Report No.: 13-01-RBP-147 EMC TESTING DEPARTMENT Page: A1/A3

Report No.: 13-01-RBP-147 EMC TESTING DEPARTMENT Page: A2/A3

Report No.: 13-01-RBP-147 EMC TESTING DEPARTMENT Page: A3/A3 ANNEX C: PHOTOS 1. Household and Similar Electrical Appliance Electromagnetic Fields Test Setup Photos