Absolute maximum ratings Symbol Conditions Values Unit I OUT MAX Maximum permanent output current 800 A RMS I IN MAX Maximum permanent input current 845 A DC V OUT MAX Maximum output voltage 530 V AC V BUS MAX Maximum DC bus voltage 1 100 V DC fout Maximum inverter output frequency 500 Hz fsw Maximum switching frequency 15 khz Electrical characteristics / Typical PV solar application Symbol Conditions min typ max Unit Ratings I OUT RATED Rated output current 750 A RMS No overload, V OUT Rated output voltage 360 V AC IGBT Module stack PF Power factor Chip junction T < 150 C, 1 - P OUT Rated output power (Max junction temperature = 175 C) 460 kw f SW Inverter switching frequency 3 khz f OUT Output frequency with SEMIKRON axial fan 50 Hz SEMIKUBE SlimLine - Frame SL80 V BUS Rated DC voltage "AF" option 2) 800 V DC 3-phase IGBT inverter P LOSS INV Total power losses 6 340 W Ordering No. 08801378 Description SKS SL 80 GD 50/10 - E4 P1 AF Electrical characteristics / Typical AC-Drive application LΤΕ Inverter lifetime 100 1) khrs Ordering No. 08801377 Symbol Conditions min typ max Unit Description SKS SL 80 GD 50/10 - E4 P1 G Ratings I OUT RATED Rated output current 515 A RMS Overload 150% / 1min / 5min V OUT Rated output voltage 400 V AC Features PF Power factor Chip junction T < 150 C, 0,85 - Slim design for 300mm deep cabinet P OUT Rated output power (Max junction temperature = 175 C ) 300 kw IP54 heatsink side f SW Inverter switching frequency 3 khz Fast mounting and dismounting f OUT Output frequency with SEMIKRON axial fan 100 Hz Current measurement accuracy <2% of I OUT RATED at 25 C V BUS Rated DC voltage "AF" option 2) 650 V DC <1% of I OUT RATED at 25 C on request P LOSS INV Total power losses 4 100 W Overvoltage, short circuit, and overtemperature protection LΤΕ Inverter lifetime 100 1) khrs Air cooled power stack IEC 62109-1 Filtering characteristics UL 1741, UL 508 C version on request V BUS Rated DC voltage applied to the caps bank with switching 800 1 000 V DC D-Sub 25 pin driver interface V DC CAP Max DC voltage applied to the caps bank without switching 1 100 V DC CAN interface for error storage, diagnostic and setting τ d5% Discharge time of the capacitors (5%) 600 s Typical Applications C DC Capacitor bank capacity 2,85 3,15 mf LTE Calculated LTE of the caps with forced air cooling 100 khrs Solar PV Inverters AC Drives Stack Insulation Active Front End V ISOL Frame / Power stage AC/DC (insulation test voltage DC, 60s) 4 200 V Remarks For information regarding installation and conditions of use, please refer to SEMIKUBE SlimLine user manual T cooling air 1) = 40 C unless otherwise specified T cooling air 1) = 40 C unless otherwise specified Footnotes 1) Tcooling air =40 C, < 1000m, with fan option 088 01139 Tcabinet = 55 C with 2m/s air ventilation inside ca binet on stack to avoid hot spots 2) Performances with "AF" option on AC side according drawing page 4&6 B6CI 1
Environmental conditions Characteristics Conditions min typ max Unit Storage, Transport, Operation Storage: IEC 60721-3-1, class 1K4-40 70 C Temperature Transportation: IEC 60721-3-2, class 2K4-40 70 C Operation 1) : IEC 60721-3-3, class 3K3 extended -30 60 C Humidity Operation (3K3) extended (no condensation) 5 93 % Standard compliance, Mechanical features Installation altitude Altitude without voltage derating 2 000 m IGBT Module stack Between air cooling and electrical IP54 Protection index IEC 60529 connections - At electronic side IP00 SEMIKUBE SlimLine - Frame SL80 Pollution degree In compliance with IEC standards PD2-3-phase IGBT inverter Overvoltage category According to UL1741 standard OVC III - According to IEC 62109-1 (Basic Insulation) OVC II - Ordering No. 08801378 Protective Separation According to IEC 62109-1 standard Reinforced insulation - Description SKS SL 80 GD 50/10 - E4 P1 AF (Sichere Trennung) Ordering No. 08801377 3-phase IGBT inverter 47,5 Weight kg Description SKS SL 80 GD 50/10 - E4 P1 3-phase IGBT inverter including fan assembly 50,5 Axial fan data Features V SUPPLY Heatsink fan DC voltage supply 24 30 V DC Slim design for 300mm deep cabinet Heatsink fans P FAN Rated power at V SUPPLY per fan, PWM 100% 440 W IP54 heatsink side LTE Fan Life time expectancy L 10 at 40 C 115 000 h Fast mounting and dismounting Current measurement accuracy <2% of I OUT RATED at 25 C <1% of I OUT RATED at 25 C on request Driver Characteristcs Overvoltage, short circuit, and overtemperature protection Symbol Conditions min typ max Unit Air cooled power stack Driver board data UL 1741, UL 508 C and IEC 62109-1 Ready V S Supply voltage 19,2 24 28,8 VDC D-Sub 25 pin driver interface I VP, IDLE Supply primary current (no load) 100 ma CAN interface for error storage, diagnostic and setting I VP, LOAD Max. supply primary current 1 000 ma ViT+ input threshold voltage HIGH 10 Vs VDC ViT- input threshold voltage LOW GND 5 VDC Typical Applications R IN Input resistance 10 kω t powerup Power up time 200 300 ms Solar PV Inverters t D Dead Time 2 µs AC Drives Measurements & protections Active Front End Scaling 10 mv.v -1 Accuracy of analogue signal @ T a =25 C -2 +2 % DC link voltage Remarks Temperature coefficient tbc %.K -1 sensing For information regarding installation and conditions of use, U Max. output current 5 ma DC analogue OUT please refer to SEMIKUBE SlimLine user manual Max. voltage range -10 10 V DC Max measurable DC Link Voltage 1 000 V DC V DCTRIP Over voltage trip level O.V.P 1 000 2) V DC Footnotes Scaling 6,727 mv.a -1 1) Tcooling air =40 C, < 1000m, with fan option 088 01139 Tcabinet = 55 C with 2m/s air ventilation inside ca binet on stack to avoid hot spots Current sensing I analogue OUT per phase Accuracy of analogue signal at 25 C 2 % Temperature coefficient tbc %.K -1 Max. output current 5 ma Voltage range -10 10 V DC 2) Factory settings I TRIPSC Over current trip level O.C.P 1 500 2) A PEAK Scaling over 30 C 110 C temperature range VTana*8+30 C Temperature sensing T analogue OUT Linear temperature range 30 110 C Accuracy of analogue signal over 65 C 110 C range -2,5 2,5 % Max. output current 5 ma Max. voltage range 0 10 V DC T TRIP Over temperature trip level O.T.P 110 2) C Tth Threshold level for reset after failure event 70 C HALT signal Bidirectional signal with dominant (LOW) GND 5 VDC Bidirectional signal with recessive (HIGH) 10 Vs VDC B6CI 2
900 850 Output current [Arms] 800 700 600 500 400 300 V BUS = 800Vdc V OUT = 360Vac C os Ø = 1 F OUT = 50 Hz Altitude = 1 000 m 200 2 3 4 5 6 7 8 9 Switching frequency [khz] Air cooling temperature : (Tcooling=Tcabinet) 30 C 40 C 50 C Max. Output current vs. Switching frequency Output current [Arms] 800 750 700 650 600 550 500 450 400 V BUS = 650Vdc V OUT = 400Vac C os Ø = 0,85 F sw = 3 khz Altitude = 1 000 m No overload 350 1 10 100 1000 Output frequency [Hz] Air cooling temperature : (Tcooling=Tcabinet) 40 C 50 C Max. Output current vs. Ambient temperature 3
Electrical and mechanical connections with fan (fan option : ref 08801148) 1. 2. 3. 5. 6. 7. 13. 9. 8. 5. 7. 13. 1. Phase "U" AC Output terminal 2. Phase "V" AC Output terminal 9. 8. 3. Phase "W" AC Output terminal X10 - Fan system connector 5. Lifting lugs (TOP) 6. Lifting lugs (BOT) 7. Earth terminal (PE) 8. Positive Input terminal "DC+" (x3 screws) 10.1 10.2 10.3 9. 10.1 Negative Input terminal "DC -" (x3 screws) X1.1 - U leg - Driver connector 10.2 X1.2 - V leg - Driver connector 10.3 X1.3 - W leg - Driver connector LED driver status Mounting holes (x6 holes) 13. Heatsink fan assembly (option : 08801148) WARNING 1 : Stack shall be mounted using the dedicated mounting kit assembly delivered with the stack, please refer to the Installation Manual WARNING 2 : It is the customer's responsibility to ensure that the environment of the SlimLine is installed into conforms to the SlimLine specifications. 1. 2. 3. WARNING 3 : It is the customer's responsibility to ensure that the mechanical frame of the SEMIKUBE SL is installed into conforms to the Installation Manual 4
Driver X1 connector assignment X1.1/X1.2/X1.3 Connector assignment 10.1 10.2 10.3 X1.1/X1.2/X1.3 D- Sub connectors X1.1 - U leg - Driver connector X1.2 - V leg - Driver connector X1.3 - W leg - Driver connector X1 Connector dimensions X10 Connector assignment WAGO (261-333) 4-Conductor terminal block with fixing flange 5
Dimensions with fans (fan option : ref 08801148) (1/2) 6
Dimensions / Openings (2/2) * The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our staff 7